Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

200 h of discharge cycling with an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) offer an approach to energy storage and electricity generation by harnessing low-grade heat (T < 150 °C). A TRAB discharge resembles that of a flow battery, where electrochemical reactions produce electrical power from energy stored within aqueous electrolytes. While there are many types of TRABs, the all-aqueous copper TRAB (Cu aq -TRAB) has produced the largest power and energy storage densities. Despite many improvements to TRAB performance, most tests have only lasted a few hours, which are not representative of operation times expected of these devices. Herein, we operated a Cu aq -TRAB for 200 h of constant current discharging to assess battery performance and component stability. After 200 h of testing, the average power density increased slightly to 7.2 mW cm -2 , which was within 0.01 % of starting conditions. Likewise, the average energy density for the final cycle was only 0.03 % lower than the initial cycle. The overall insensitivity of the power cell to cycling represents a major milestone in the advancement of TRAB systems. In conclusion, energy dispersive X-ray spectroscopy provides evidence to suggest that these small changes in power and energy density are likely to the membrane acclimating to TRAB electrolytes.

25 ENERGY STORAGE↗

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An RF dosimeter for independent SAR measurement in MRI scanners

Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging subject, albeit with fluctuations. Conclusions: Our 3T RF dosimeter and transducers accurately measure RF exposure in body-equivalent loads and provide scanner-independent assessments of whole-body RF power deposition for establishing safety compliance useful for MRI sequence and device testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

Power Converter Control Algorithm Design and Simulation for the NREL Next-Generation Drivetrain: July 8, 2013 - January 7, 2016

The National Renewable Energy Laboratory (NREL) and NREL Next-Generation Drivetrain Partners are developing a next-generation drivetrain (NGD) design as part of a Funding Opportunity Announcement award from the U.S. Department of Energy. The proposed NGD includes comprehensive innovations to the gearbox, generator, and power converter that increase the gearbox reliability and drivetrain capacity, while lowering deployment and operation and maintenance costs. A key task within this development effort is the power converter fault control algorithm design and associated computer simulations using an integrated electromechanical model of the drivetrain. The results of this task will be used in generating the embedded control software to be utilized in the power converter during testing of the NGD in the National Wind Technology Center 2.5-MW dynamometer. A list of issues to be addressed with these algorithms was developed by review of the grid interconnection requirements of various North American transmission system operators, and those requirements that presented the greatest impact to the wind turbine drivetrain design were then selected for mitigation via power converter control algorithms.

17 WIND ENERGY↗

Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)

The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distribution feeder simulation.

25 ENERGY STORAGE↗

Testing and Processing of Pre-production 325 MHz Single Spoke Resonator Power Couplers for PIP-II Project

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

43 PARTICLE ACCELERATORS↗

TESTING AND PROCESSING OF PRE-PRODUCTION 325 MHZ SINGLE SPOKE RESONATOR POWER COUPLERS FOR PIP-II PROJECT

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project [1]. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of 1-D crustal velocity structure beneath Izmir Gulf and surroundings by using local earthquakes

In this study; we examined one dimensional crustal velocity structure of Izmir gulf and surroundings. We used nearly one thousand high quality (A and B class) earthquake data which recorded by Disaster and Emergency Management Presidency (AFAD) [1], Bogazici University (BU-KOERI) [2] and National Observatory of Athens (NOA) [3,4]. We tried several synthetic tests to understand power of new velocity structure, and examined phase residuals, RMS values and shifting tests. After evaluating these tests; we decided one dimensional velocity structure and minimum 1-D P wave velocities, hypocentral parameter and earthquake locations from VELEST algorithm. Distribution of earthquakes was visibly improved by using new minimum velocity structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wave Energy Converter Power Take-Off Modeling and Validation From Experimental Bench Tests

This article describes the implementation of a new numerical model of the power take-off system installed in the Monterey Bay Aquarium Research Institute wave energy converter, a device developed to provide power to various oceanic research missions. The simultaneous presence of hydraulic, pneumatic, and electrical subsystems in the power take-off system represents a significant challenge in forging an accurate model able to replicate the main dynamic characteristics of the system. The validation of the new numerical model is addressed by comparing simulations with the measurements obtained during a series of bench tests. Data from the bench tests show good agreement with the numerical model. The validated model provides deeper insights into the complex nonlinear dynamics of the power take-off system and will support further performance improvements in the future.

16 TIDAL AND WAVE POWER↗

Partial Shade Endurance Testing for Monolithic Photovoltaic Modules

In monolithically integrated photovoltaic (PV) modules, including CdTe, CIGS, and a-Si modules, some shadows can cause permanent damage under some operating conditions. This damage reduces efficiency and causes shunts that are visible to the eye and in luminescence imaging. Although these shadows are sometimes forbidden by product documentation, we have observed this type of damage in utility-scale PV systems. Existing standards ensure that qualified modules are safe to use after they are damaged by shadows. But no standard test exists to quantify the loss of efficiency that can result from this damage. In this work we describe new, accelerated tests to quantify the power loss that occurs due to shadows from human bodies and narrow objects, such as tools, placed nearby or directly touching modules. The tests are designed to be easy to conduct uniformly across products and laboratories. The tests can be performed outdoors and last only a few minutes. In our trials on commercial products, these tests resulted in 2%-27% permanent loss in power at standard test conditions (STC). The relative loss was several times larger when measured at lower irradiance. The tests we describe can be used to differentiate products, to direct the development of technological solutions to shadow sensitivity at the cell and module levels, and to establish the need for system-level and administrative solutions to the occurrence of shadows. Similar tests will be the basis of a new International Electrotechnical Commission (IEC) technical specification (TS) 63140.

14 SOLAR ENERGY↗

Design of a horizontal test cryostat for superconducting RF cavities for the FREIA facility at Uppsala University

Uppsala University is constructing a large scale facility, called FREIA (Facility for Research Instrumentation and Accelerator Development). FREIA includes a helium liquefier and an accelerator test facility and has the capacity to test superconducting radio-frequency (RF) cavities with the same RF system and RF power level as in an accelerator. A central element of FREIA is a horizontal test cryostat connected in closed loop to a helium liquefier. This cryostat can house two fully equipped (tuners, piezo, power coupler, helium tank) superconducting cavities to perform full RF high power tests and operate at temperatures between 1.8 K and 4.2 K. The cryostat is designed to accommodate a large array of superconducting cavities and magnets, among which the European Spallation Source (ESS) type spoke and high-β elliptical cavities as well as TESLA/ILC type elliptical cavities. The present status of the project and the design of the cryostat are reported.

43 PARTICLE ACCELERATORS↗

An Accelerated Creep Testing Program For Nickel Based Superalloys

In order to improve the energy production within the United States, new materials are developed with the goal of increased functionality. These materials are required to perform at extreme pressures and temperatures (up to and beyond 200MPa and 650â??) as well as be sustainable beyond 105 hours. Before developing these materials into components for power generation, mechanical testing is required to better understand the behavior of these materials at various loads and temperatures. The longest of these tests is the conventional creep test which is a real time test that can beyond 105 hours depending on service conditions. Hundreds of specimens must be tested before being approved for use in power generation, but it is extremely difficult to rapidly qualify when each material is required to exceed 105 hours making testing through conventional means unfeasible. While others have designed accelerated testing methods to help qualify materials, many of these experiments use an empirical approach that requires test data to fit already existing creep data. In this study, an accelerated creep test called the stepped isostress method (SSM) is then applied to wrought Inconel 718 (IN 718) specimens. A test matrix is designed using deformation mechanism maps, time-temperature-transformation diagrams, and time-temperature-precipitation diagrams, in order to ensure that microstructurally, the accelerated creep tests fail similarly to the conventional creep tests. The data from the stepped isostress method is then applied to the McVetty and Sin-hyperbolic (Sinh) constitutive models in order to generate a creep master curve. The results from the model fits are then compared to the conventional creep data done from experiments as well as from the NIMS database for Inconel 718. Optical microscopy and scanning electron microscopy are used to compare the evolution of the microstructure from the conventional creep and accelerated creep tests. It is found that using the Sinh model on the accelerated creep data provides reasonable creep rupture predictions when compared to the scatter band of creep tests. It was also observed that the microstructural evolution between the SSM experiments and creep tests were very similar in terms of the volume fraction of precipitates and phases.

Mach, Robert↗