Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Equatorial long waves in geostationary satellite observations and in a multichannel sea surface temperature analysis

Geostationary satellite observations of a zonally oriented sea surface temperature front in the eastern equatorial Pacific were made between 1975 and 1981. Long waves appeared along the front mainly during the summer and fall, except during 1976, the year of an El Nino. The waves have averaged periods of 25 days and wavelengths of 1000 km. At the end of 1981, the long waves also were detected in a new sea surface temperature analysis based on multichannel infrared measurements from a polar-orbiting satellite. This quantitative analysis may improve the ability to resolve low-frequency equatorial wave motions from satellite observations.

Legeckis, R.↗

Planetary and satellite x ray spectroscopy: A new window on solid-body composition by remote sensing

The rings and most of the satellites of the outer planets orbit within the radiation belts of their parent bodies. This is an environment with intense fluxes of energetic electrons. As a result, these objects are strong emitters of X-rays. The characteristic X-ray lines from these bodies depend on atomic composition, but they are not sensitive to how the material is arranged in compounds or mixtures. X-ray fluorescence spectral analysis has demonstrated its unique value in the laboratory as a qualitative and quantitative analysis tool. This technique has yet to be fully exploited in a planetary instrument for remote sensing. The characteristic X-ray emissions provide atomic relative abundances. These results are complementary to the molecular composition information obtained from IR, visible, and UV emission spectra. The atomic relative abundances are crucial to understanding the formation and evolution of these bodies. They are also crucial to the proper interpretation of the molecular composition results from the other sensors. The intensities of the characteristic X-ray emissions are sufficiently strong to be measured with an instrument of modest size. Recent developments in X-ray detector technologies and electronic miniaturization have made possible space-flight X-ray imaging and nonimaging spectrometers of high sensitivity and excellent energy resolution that are rugged enough to survive long-duration space missions. Depending on the application, such instruments are capable of resolving elemental abundances of elements from carbon through iron. At the same time, by measuring the bremsstrahlung intensity and energy spectrum, the characteristics of the source electron flux can be determined. We will discuss these concepts, including estimated source strengths, and will describe a small instrument capable of providing this unique channel of information for future planetary missions. We propose to build this instrument using innovative electronics packaging methods to minimize size and weight.

Chenette, D. L.↗

Supply and Resource Management to Progressively Enable EIMO

BACKGROUND: Current medical operations in Low Earth Orbit (LEO) allow for real-time audio-video communication with a flight surgeon at mission control, resupply, and medical evacuation to earth on the order of hours. As mission profiles change from LEO to the Moon, Mars, and beyond, medical risk as a contribution to overall mission risk is anticipated to rise substantially. Concurrently, due to the distance, the medical systems on board vehicles proposed for these mission types are expected to have reduced mass and volume allocation. Together, astronaut crews will be at a higher risk of major medical events, be required to perform a broader set of tasks, and have substantially reduced resources and support to do so. Earth Independent Medical Operations (EIMO) aims to identify and fill the gaps present in this progressively changing paradigm. OVERVIEW: Medical supplies, resources, and skills are central to spaceflight medical systems. Vehicles used for non-LEO missions are anticipated to be smaller and thus the medical system will also need to have reduced mass, volume, and power. Medical resources are another form of consumable and may need resupply or pre-deployment to meet crew needs. One particular concern is the degradation of medications which become less efficacious and potentially toxic with time, particularly given environmental conditions such as temperature, humidity, oxygen, and radiation which have not yet been fully studied. Supply and resource management in LEO is dependent on resupply, however the supply chain of transporting equipment does not yet have a clear infrastructure for missions beyond LEO. DISCUSSION: EIMO is intended to systemically identify and fill these gaps with forward-looking solutions. In mission monitoring of resources with technology like RFID, improving medical resource longevity, targeted resupply and careful pre-mission planning will be central to facilitate crew health and performance. One approach to optimizing resources is the Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool, which uses probabilistic risk assessment (PRA) to quantitatively predict medical risk and identify resources and skills that mitigate this risk. This evidence based, quantitative analysis prediction tool and several other approaches to meeting the challenge of supply and resource management are discussed.

Arian Anderson↗

Amino Acids Profiles in Biological Media

An accurate analytical method was developed to determine amino acids in some biological specimens by GC/MS technique. Stable isotopes provide useful tools for a variety of studies, offering ideal internal standards in quantitative information. Isotopic dilution gas chromatography--mass spectrometry (ID-GC/MS) is the techniques used for quantitative analysis of compounds labeled with stable isotopes. A Trace DSQ Thermo Finnigan quadrupole mass spectrometer coupled with a Trace GC was used. Amino acids were separated on a Rtx-5 MS capillary column, 30 mx0.25 mm, 0.25 {mu}m film thickness, using a temperature program from 50 deg. C, 1 min, 6 deg. C/min at 100 deg. C, 4 deg. C/min at 200 deg. C, 20 deg. C/min at 300 deg. C, (3 min). The transfer line temperature was 250 deg. C, the injector temperature 200 deg. C and ion source temperature 250 deg. C; splitter: 10:1. Electron energy was 70 eV and emission current, 100 {mu}A. The amino acids were purified on a Dowex 50W-W8 exchange resin and were derivatized in a procedure following two steps to obtain trifluoroacetyl butyl esters. The identification of amino acids was obtained by using NIST library but also by using amino acid standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of a Liquid Extraction Based Sealing Surface Sampling Probe for Mass Spectrometric Analysis of Dried Blood Spots and Mouse Whole-Body Thin Tissue Sections

The utility of a liquid extraction based sealing surface sampling probe (SSSP) for the direct mass spectrometric analysis of targeted drugs and metabolites in dried blood spots (DBSs) and whole mouse thin tissue sections was demonstrated. The accuracy and precision for the quantitative analysis of a minimum of 50 ng/mL sitamaquine or acetaminophen in DBSs on paper were well within the required 15% dictated by internationally recognized acceptance criteria for assay validations. Analysis of whole-body mouse thin tissue sections from animals dosed with propranolol, adhered to an adhesive tape substrate, provided semi-quantitative information for propranolol and its hydroxyproranolol glucuronide metabolite within specific organs of the tissue. The relative abundances recorded for the two compounds in the brain, lung, kidney and liver were in nominal agreement with previously reported amounts based on analysis using a liquid microjunction surface sampling probe (LMJ-SSP), and whole-body autoradiography (WBA) and HPLC-MS analysis. The ability to sample and analyze from tape-adhered tissue samples, which are generally employed in WBA analysis, presents the possibility of consecutive WBA and SSSP-MS analysis of the same tissue section. This would facilitate assignment, and possibly quantitation, of the different molecular forms of total drug related material detected in the WBA analysis. The flexibility to sample larger or smaller spot sizes, alternative probe sealing mechanisms, and a reduction in internal volumes and associated sample carryover issues will be among the first simple improvements necessary to make the SSSP-MS method a practical DBS and/or thin tissue section analysis tool or to expand its use to other surface sampling applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phylogenetic Patterns in the Microbial Response to Resource Availability: Amino Acid Incorporation in San Francisco Bay

Aquatic microorganisms are typically identified as either oligotrophic or copiotrophic, representing trophic strategies adapted to low or high nutrient concentrations, respectively. Here, we sought to take steps towards identifying these and additional adaptations to nutrient availability with a quantitative analysis of microbial resource use in mixed communities. We incubated an estuarine microbial community with stable isotope labeled amino acids (AAs) at concentrations spanning three orders of magnitude, followed by taxon-specific quantitation of isotopic incorporation using NanoSIMS analysis of high-density microarrays. The resulting data revealed that trophic response to AA availability falls along a continuum between copiotrophy and oligotrophy, and high and low activity. To illustrate strategies along this continuum more simply, we statistically categorized microbial taxa among three trophic types, based on their incorporation responses to increasing resource concentration. The data indicated that taxa with copiotrophic-like resource use were not necessarily the most active, and taxa with oligotrophic-like resource use were not always the least active. Two of the trophic strategies were not randomly distributed throughout a 16S rDNA phylogeny, suggesting they are under selective pressure in this ecosystem and that a link exists between evolutionary relatedness and substrate affinity. The diversity of strategies to adapt to differences in resource availability highlights the need to expand our understanding of microbial interactions with organic matter in order to better predict microbial responses to a changing environment.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated laser ablation-dropletProbe-mass spectrometry for absolute drug quantitation, metabolite detection, and distribution in tissue

Rationale: Spatially resolved and accurate quantitation of drug-related compounds in tissue is a much-needed capability in drug discovery research. In this work, application of an integrated laser ablation-dropletProbe-mass spectrometry surface sampling system (LADP-MS) is reported, which achieved absolute quantitation of propranolol measured from <500 × 500 μm thin tissue samples. Methods: Mouse liver and kidney thin tissue sections were coated with parylene C and analyzed for propranolol by a laser ablation/liquid extraction workflow. Non-coated adjacent sections were microdissected for validation and processed using standard bulk tissue extraction protocols. High-performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry was applied to detect the drug and its metabolites. Results: Absolute propranolol concentration in ~500 × 500 μm tissue regions measured by the two methods agreed within ±8% and had a relative standard deviation within ±17%. Quantitation down to ~400 × 400 μm tissue regions was shown, and this resolution was also used for automated mapping of propranolol and phase II hydroxypropranolol glucuronide metabolites in kidney tissue. Conclusions: This study exemplifies the capabilities of integrated laser ablation-dropletProbe-mass spectrometry (LADP-MS) for high resolution absolute drug quantitation analysis of thin tissue sections. This capability will be valuable for applications needing to quantitatively understand the spatial distribution of small molecules in tissue.

47 OTHER INSTRUMENTATION↗

A database system to support image algorithm evaluation

The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.

Lien, Y. E.↗

Thermal Analyzer for Planetary Soil (TAPS): an in Situ Instrument for Mineral and Volatile-element Measurements

Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm(sup 3), occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.

Gooding, J. L.↗

Rapid Evaluation of Particle Properties using Inverse SEM Simulations

This report is the final deliverable of a 3 year project whose purpose was to investigate the possibility of using simulations of X-ray spectra generated inside a scanning electron microscope (SEM) as a means to perform quantitative analysis of the sample imaged in the SEM via an inverse analysis methodology. Using the nine point Technology Readiness Levels (TRL) typically used by the US Department of Defense (DOD) and the National Aeronautics and Space Administration (NASA), this concept is now at a TRL of 3. In other words, this work has proven the feasibility of this concept and is ready to be further investigated to address some of the issues highlighted by this initial proof of concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of porous transport electrodes: Development of quantitative approach for quality control

This work focuses on porous transport electrodes (PTEs), which integrate the anodic catalyst with the adjacent Ti porous transport layer (PTL). Challenges in catalyst deposition on PTLs, particularly at low loadings, motivated this study to evaluate various fabrication methods and characterization approaches. This work investigated Pt-treated PTLs coated with Ir-based catalysts using several common methods, including airbrush coating, rod coating, ultrasonic spray coating, electrodeposition, and sputter deposition, with catalyst loadings ranging from 2.9 to 0.1 mg/cm 2 , providing the opportunity for comparisons across a large set of samples produced by different methods. Two widely accessible characterization techniques: X-ray computed tomography (XCT) and scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDS) were explored. Initial evaluation of selected samples with XCT provided qualitative insights into catalyst distribution, however comprehensive quantitative analysis was limited. SEM-EDS enabled detailed information on the catalyst distribution both qualitatively and quantitatively using two metrics. Atomic and surface area % ratios of Pt:Ir and Ti:Ir revealed trends in catalyst loading and losses into the PTL pores, as well as evaluating the homogeneity of catalyst coatings. The analysis demonstrated that ultrasonic spray coating, electrodeposition, and sputter coating produced the most homogeneous coatings, with minimal catalyst losses observed for electrodeposition and sputter coating. By adapting common techniques with novel, standardized methodologies, this work establishes a universally applicable framework for cross-study comparison of PTEs. The SEM-EDS approach provides a practical, accessible tool for PTE characterization and contributes a reference dataset supporting both research development and rapid quality control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote sensing and spectral analysis of plumes from ocean dumping in the New York Bight Apex

The application of the remote sensing techniques of aerial photography and multispectral scanning in the qualitative and quantitative analysis of plumes from ocean dumping of waste materials is investigated in the New York Bight Apex. Plumes resulting from the dumping of acid waste and sewage sludge were observed by Ocean Color Scanner at an altitude of 19.7 km and by Modular Multispectral Scanner and mapping camera at an altitude of 3.0 km. Results of the qualitative analysis of multispectral and photographic data for the mapping, location, and identification of pollution features without concurrent sea truth measurements are presented which demonstrate the usefulness of in-scene calibration. Quantitative distributions of the suspended solids in sewage sludge released in spot and line dumps are also determined by a multiple regression analysis of multispectral and sea truth data.

Johnson, R. W.↗

A deep learning model for automatic analysis of cavities in irradiated materials

Transmission electron microscopy (TEM) is a commonly used technique in materials science for defect investigation. Quantitative analysis of defects is important for understanding the properties of a material, but manual analysis of TEM micrographs can be time-consuming and prone to error, especially when the defects have irregular shapes rather than spherical shapes. Many existing methods or deep learning models do not handle a wide range of sizes for the same object type within a single image. In this work, we present a framework that enables users to train an instance segmentation model called Mask R- CNN on any microstructure dataset, perform multi-detection on the same image at different scales, and obtain properties (e.g., size, area) of the objects based on the desired shape (e.g., circle, ellipse, rectangle). Additionally, we have developed a parallel detection module that uses multiple GPUs to increase the efficiency of the object detection process. We demonstrate the capabilities of our framework using a set of TEM images of cavities with different shapes, size distributions, and background contrasts. Finally, we show that the performance of our model in terms of density, size, and swelling of the cavities is comparable to the human average and that our model achieves the highest recall value compared to existing methods due to the use of image multi-rescaling.

36 MATERIALS SCIENCE↗

Determination of the Absolute Number of Cytokine mRNA Molecules within Individual Activated Human T Cells

A primary function of activated T cells is the expression and subsequent secretion of cytokines, which orchestrate the differentiation of other lymphocytes, modulate antigen presenting cell activity, and alter vascular endothelium to mediate an immune response. Since many features of immune regulation probably result from modest alterations of endogenous rates of multiple interacting processes, quantitative analysis of the frequency and specific activity of individual T cells is critically important. Using a coordinated set of quantitative methods, the absolute number of molecules of several key cytokine mRNA species in individual T cells has been determined. The frequency of human blood T cells activated in vitro by mitogens and recall protein antigens was determined by intracellular cytokine protein staining, in situ hybridization for cytokine mRNA, and by limiting dilution analysis for cytokine mRNA+ cells. The absolute number of mRNA molecules was simultaneously determined in both homogenates of the entire population of cells and in individual cells obtained by limiting dilution, using a quantitative, competitive RT-PCR assay. The absolute numbers of mRNA molecules in a population of cells divided by the frequency of individual positive cells, yielded essentially the same number of mRNA molecules per cell as direct analysis of individual cells by limiting dilution analysis. Mean numbers of mRNA per positive cell from both mitogen and antigen activated T cells, using these stimulation conditions, were 6000 for IL-2, 6300 for IFN-gamma, and 1600 for IL-4.

Karr, Laurel J.↗

3D RoboMET Characterization

The goal of this project is to generate 3D microstructural data by destructive and non-destructive means and provide accompanying characterization and quantitative analysis of such data. This work is a continuing part of a larger effort to relate material performance variability to microstructural variability. That larger effort is called “Predicting Performance Margins” or PPM. In conjunction with that overarching initiative, the RoboMET.3D™ is a specific asset of Center 1800 and is an automated serialsectioning system for destructive analysis of microstructure, which is called upon to provide direct customer support to 1800 and non-1800 customers. To that end, data collection, 3d reconstruction and analysis of typical and atypical microstructures have been pursued for the purposes of qualitative and quantitative characterization with a goal toward linking microstructural defects and/or microstructural features with mechanical response. Material systems examined in FY15 include precipitation hardened 17-4 steel, laser-welds of 304L stainless steel, thermal spray coatings of 304L and geological samples of sandstone.

Madison, Jonathan D.↗

Visual scanning behavior

This report summarizes the results and knowledge of scan behavior gained in various simulation and laboratory studies. Results were obtained through various analysis techniques such as real-time viewing of the pilot's scanning behavior and quantitative analysis of scan behavior performance parameters (average dwell time, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures). Pilot scan behavior is discussed in the following areas; scanning is a subconscious conditioned activity, scanning is situation dependent, pilots' scanning pattern is centered around a home base. Scanning behavior data have been shown to be useful in determining pilot's workload, evaluating pilot's strategy and role, determining the rate of information transfer of various displays, and aiding in pilot training.

Harris, R. L., Sr.↗

Visual scanning behavior

This report summarizes the results and knowledge of scan behavior gained in various simulation and laboratory studies. Results were obtained through various analysis techniques such as real-time viewing of the pilot's scanning behavior and quantitative analysis of scan behavior performance parameters (average dwell time, dwell percentages, instrument transition paths, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures). Pilot scan behavior is discussed in the following areas; scanning is a subconscious conditioned activity, scanning is situation dependent, pilots' scanning pattern is centered around a home base. Scanning behavior data nave been shown to be useful in determining pilot's workload, evaluating pilot's strategy and role, determining the rate of information transfer of various displays, and aiding in pilot training.

Harris, R. L., Sr.↗

Generational Analysis Reveals that TGF-Beta1 Inhibits the Rate of Angiogenesis in Vivo by Selective Decrease in the Number of New Vessels

Quantitative analysis of vascular generational branching demonstrated that transforming growth factor-beta1 (TGF-beta1), a multifunctional cytokine and angiogenic regulator, strongly inhibited angiogenesis in the arterial tree of the developing quail chorioallantoic membrane (CAM) by inhibition of the normal increase in the number of new, small vessels. The cytokine was applied uniformly in solution at embryonic day 7 (E7) to the CAMs of quail embryos cultured in petri dishes. After 24 h the rate of arterial growth was inhibited by as much as 105% as a function of increasing TGF-beta1 concentration. Inhibition of the rate of angiogenesis in the arterial tree by TGF-beta1 relative to controls was measured in digital images by three well-correlated, computerized methods. The first computerized method, direct measurement by the computer code VESGEN of vascular morphological parameters according to branching generations G(sub 1) through G(sub greater than or equal to 5), revealed that TGF-beta1 selectively inhibited the increase in the number density of small vessels, N(sub v greater than or equal to 5), (382 plus or minus 85 per square centimeter) for specimens treated with 1 microgram TGF-beta1/CAM for 24 h, compared to 583 plus or minus 99 per square centimeter for controls), but did not significantly affect other parameters such as average vessel length or vessel diameter. The second and third methods, the fractal dimension (D(sub f)) and grid intersection (rho (sub v)), are statistical descriptors of spatial pattern and density. According to D(sub f) and rho(sub v), arterial density increased in control specimens from 1.382 plus or minus 0.007 and 662 plus or minus 52 per square centimeters at E7 (0 h) to 1.439 plus or minus 0.013 and 884 plus or minus 55 per square centimeters at E8 (24 h), compared to 1.379 plus or minus 0.039 and 650 plus or minus 111 per square centimeter for specimens treated with 1 microgram TGF-beta1/CAM for 24 h. TGF-beta1 therefore regulates vascular pattern and the rate of angiogenesis in a unique fingerprint manner, as do other major angiogenic regulators that include VEGF, FGF-2 (bFGF), and angiostatin. TGF-beta1 did not stimulate angiogenesis significantly at low cytokine concentrations, which suggests that this quail CAM model of angiogenesis is not associated with an inflammatory response.

Parsons-Wingerter, Patricia↗