Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reactor Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Scaling Analysis for the Direct Reactor Auxillary Cooling System For AHTRS

The Direct Reactor Auxiliary Cooling System (DRACS) is a passive heat removal system proposed for the Advanced High-Temperature Reactor (AHTR) that combines the coated particle fuel and graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops relying completely on buoyancy as the driving force. In the DRACS, two heat exchangers, namely, the DRACS Heat Exchanger (DHX) and the Natural Draft Heat Exchanger (NDHX) are used to couple these loops. In addition, a fluidic diode is employed to minimize the parasitic flow during normal operation of the reactor and to activate the DRACS in accidents. While the DRACS concept has been proposed, there are no actual prototypic DRACS systems for AHTRs built and tested in the literature. In this paper, a detailed scaling analysis for the DRACS is performed, which will provide guidance for the design of the scaled-down DRACS test facilities. Based on the Boussinesq assumption and one-dimensional flow formulation, the governing equations are non-dimensionalized by introducing appropriate dimensionless parameters. The key dimensionless numbers that characterize the DRACS system are obtained straightforwardly from the non-dimensional governing equations. Based on the dimensionless numbers and non-dimensional governing equations, similarity laws are proposed. In addition, a scaling methodology has also been developed, which consists of the core scaling and loop scaling. The consistence between the core and loop scaling is examined through the reference volume ratio, which can be obtained from the core and loop scaling processes. The scaling methodology and similarity laws have been applied to obtain a design of the scaled-down high-temperature DRACS test facility (HTDF).

Scaling auxiliary AHTRS DRACS liquid salt molten r↗

Vibration Analysis of Advanced Test Reactor Mini-Plate Hydraulic Test in the OSU HMFTF

Currently, flow testing is being performed at Oregon State University (OSU) on the Hydro-Mechanical Fuel Test Facility (HMFTF) to aid in the qualification of low enriched plate-type Uranium fuels for use in high performance research reactors (HPRR) in the US, under the Global Threat Reduction Initiative (GTRI). Under this project, varying fuel geometries proposed for irradiation testing in the Advanced Test Reactor (ATR) are being hydraulically tested in the HMFTF prior to being placed in the ATR; these tests included the use of high-resolution tri-axis accelerometers affixed to the experiment in multiple locations. The premise of this study was to conduct a vibration analysis on the test designated as miniplate1 (MP-1) Large B experiment which is planned for irradiation testing in the ATR's Large B experiment location. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physical Security Timeline Analysis in Support of Advanced Reactor Demonstration and Deployment

This report presents the regulatory requirements and directions on the physical security of advanced nuclear reactors in USA. Presently, a rule is being proposed that allows for a performance-based analysis. In determining the physical security requirements for an advanced reactor, new tools may be desired to conduct a performance-based analysis. These tools should incorporate dynamic analysis methods to provide as much realism as possible. In comparison, the security requirements for existing light water reactors (LWRs) are much more prescriptive and the analysis conducted to establish the required physical security strategies were more easily performed with static analysis. In order to achieve the cost goals that advanced reactors require for adoption; the nuclear security force required should not be excessive. Dynamic physical security analysis methods and tools have been developed by the US Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program. This report details how the dynamic risk analysis tools developed in the LWRS program using the dynamic risk modelling tool, EMRALD, may be adapted for use in analyzing the physical security designs for advanced reactors accounting for variable performance-based requirements. This report provides an example analysis of a hypothetical SFR using publicly available information and generic assumptions to demonstrate the methods and potential presentation and analysis of the results. No actual plant information is used in this example analysis. Future work in this area will create additional models that can be adapted for any advanced reactor concept and use various security features to create a physical security system that provides adequate protection from radiological theft and sabotage.

97 MATHEMATICS AND COMPUTING↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of the MULCH-II code for thermal-hydraulic safety analysis of the MIT research reactor conversion to LEU

An in-house thermal hydraulics code was developed for the steady-state and loss of primary flow analysis of the MIT Research Reactor (MITR). This code is designated as MULti-CHannel-II or MULCH-II. The MULCH-II code is being used for the MITR LEU conversion design study. Features of the MULCH-II code include a multi-channel analysis, the capability to model the transition from forced to natural convection during a loss of primary flow transient, and the ability to calculate safety limits and limiting safety system settings for licensing applications. This paper describes the validation of the code against PLTEMP/ANL 3.0 for steady-state analysis, and against RELAP5-3D for loss of primary coolant transient analysis. Coolant temperature measurements obtained from loss of primary flow transients as part of the MITR-II startup testing were also used for validating this code. The agreement between MULCH-II and the other computer codes is satisfactory. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRACE Analysis of Loss of Flow for the APR1400

The APR1400 is a pressurized water reactor (PWR). The APR1400 nuclear steam supply system consists of a reactor pressure vessel (RPV), which contains the reactor core, and two primary reactor coolant system loops connected in parallel to the RPV. Each coolant loop consists of a hot leg (HL), a u-tube steam generator (SG), two reactor coolant pumps (RCPs) and two cold legs (CLs). A pressurizer is connected to the hot leg on one of the coolant loops. During normal operation, the RCPs circulate high pressure water through the reactor core to remove the heat. The heated water exits the RPV and passes through the hot legs into the steam generator tubes. Heat is transferred through the walls of the steam generator tubes into a lower pressure secondary coolant system. Cooled primary system water from the steam generators is returned through the RCPs and cold legs to the RPV. The RCPs operate at constant speed; the primary coolant system is designed to provide a prescribed rate of coolant flow through the reactor core. The APR1400 SG secondary coolant system pressure is controlled through modulation of valves in the steam lines to maintain a prescribed turbine inlet pressure. The SG secondary coolant inventory is controlled by using a feedwater control system to maintain a prescribed liquid level in the steam generator downcomer. This water inventory level is sufficient to cover the outer surfaces of the steam generator tubes while preventing overfill that would cause liquid to pass from the steam generators through the steam lines into the turbine system. In the current work, the Nuclear Regulatory Commission's reactor systems analysis code, TRACE?2 was used to perform an analysis of a loss of flow anticipated operational occurrence (AOO). The loss of flow is initiated by a loss of off-site power (LOOP), resulting in a trip of the RCPs. The regulatory purpose of the current work is to confirm safety analyses documented in the APR1400 Design Control Document (DCD)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A fully-implicit high-order system thermal-hydraulics model for advanced non-LWR safety analyses

An advanced system analysis tool is being developed for advanced reactor safety analysis. This paper describes the underlying physics and numerical models used in the code, including the governing equations, the stabilization schemes, the high-order spatial and temporal discretization schemes, and the Jacobian Free Newton Krylov solution method. The effects of the spatial and temporal discretization schemes are investigated. Additionally, a series of verification test problems are presented to confirm the high-order schemes. Furthermore, it is demonstrated that the developed system thermal-hydraulics model can be strictly verified with the theoretical convergence rates, and that it performs very well for a wide range of flow problems with high accuracy, efficiency, and minimal numerical diffusions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical Uncertainties vs. Model Uncertainties in Two-phase Flow Simulations

In recent years, verification, validation and uncertainty quantification (VVUQ) have become a common practice in thermal-hydraulics analysis. In general, these activities deal with propagations of uncertainties in computer code simulations, e.g., through system analysis codes. However, most existing such activities in thermal-hydraulics analysis have been primarily focused on model uncertainties, while numerical uncertainties were largely overlooked. Numerical uncertainties (or numerical errors) can appear in many different forms, e.g., round-off error, statistical sampling error, and discretization error. As pointed out by Oberkampf and Roy, discretization error is usually the largest however the most difficult type of error to estimate reliably. In thermal-hydraulics analysis, especially two-phase flow simulations commonly encountered in reactor safety analysis, the lack of consideration on discretization error is mainly due to the difficulty in estimating them. Accurate estimations on discretization error require continuous mesh refinement and/or implementation of high-order numerical schemes in system analysis code, both of which are unfortunately difficult to achieve for existing codes. At first, it should be emphasized that mesh refinement (or mesh sensitivity study) is a well-understood concept in the thermal-hydraulics field. However, it is not commonly practiced for many reasons, e.g., lack of understanding on numerical errors by code users, consideration on computational cost, deteriorated numerical stability performance with refined meshes, and etc. Secondly, high-order (e.g., second-order) numerical schemes are simply unavailable in almost any existing system analysis code. Implementation of high-order numerical schemes in these codes is difficult, if not impossible, given the complexity of these codes. On the other hand, people tend to argue that numerical uncertainties (or discretization error as we have emphasized) are not as important as the commonly large uncertainties in two-phase flow models, e.g., closure correlations. As a result, nodalization is sometimes played unintentionally, or maybe intentionally, to match experimental data, which is referred as 'user effects' or 'compensating errors' in thermal-hydraulics community. Such a practice is highly criticized by Levy. In this work, we will at first build a computer code that incorporates both first-order and second-order numerical methods to solve the two-phase flow problems. The first-order method resembles the one used in many existing system analysis codes; and the second-order method works as the reference to estimate numerical errors. Numerical verifications on spatial discretization schemes will be presented in the form of mesh convergence study. It will also be demonstrated that, in practical scenarios, discretization errors can be as large as, or even larger than, model uncertainties via case studies.

42 ENGINEERING↗

Technical and Licensing Considerations for Micro-Reactors

The U.S. Nuclear Regulatory Commission (NRC) has interacted with vendors pursuing the commercialization of micro-reactors (i.e., reactors capable of producing about 1 MW(th) to 20 MW(th) of energy from nuclear fission). It is envisioned that micro-reactors could be assembled and fueled in a factory and shipped to a site. Many of the sites are expected to be remote locations requiring off-grid power or in some cases military bases. The objective of this effort is to explore the technical issues and the approach required to reach a finding of "reasonable assurance of public health and safety" for this new and different class of reactors. The analysis performed here leverages available micro-reactor design and testing data available from national laboratory experience as well as commercial design information to explore technical issues. Some factors considered include source term, accidents that would need to be analyzed, and the extent of the probabilistic risk assessment (PRA). The technical evaluation was performed within the framework of the Licensing Modernization Project (LMP) to identify licensing basis events, classification of structures, systems and components, and defense-in-depth needed to provide regulatory certainty. With this framework and technical evaluation in mind, the scope and content of a micro-reactor licensing application is discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling and Analysis of a Lunar Space Reactor with the Computer Code RELAP5-3D/ATHENA

The transient analysis 3-dimensional (3-D) computer code RELAP5-3D/ATHENA has been employed to model and analyze a space reactor of 180 kW(thermal), 40 kW (net, electrical) with eight Stirling engines (SEs). Each SE will generate over 6 kWe; the excess power will be needed for the pumps and other power management devices. The reactor will be cooled by NaK (a eutectic mixture of sodium and potassium which is liquid at ambient temperature). This space reactor is intended to be deployed over the surface of the Moon or Mars. The reactor operating life will be 8 to 10 years. The RELAP5-3D/ATHENA code is being developed and maintained by Idaho National Laboratory. The code can employ a variety of coolants in addition to water, the original coolant employed with early versions of the code. The code can also use 3-D volumes and 3-D junctions, thus allowing for more realistic representation of complex geometries. A combination of 3-D and 1-D volumes is employed in this study. The space reactor model consists of a primary loop and two secondary loops connected by two heat exchangers (HXs). Each secondary loop provides heat to four SEs. The primary loop includes the nuclear reactor with the lower and upper plena, the core with 85 fuel pins, and two vertical heat exchangers (HX). The maximum coolant temperature of the primary loop is 900 K. The secondary loops also employ NaK as a coolant at a maximum temperature of 877 K. The SEs heads are at a temperature of 800 K and the cold sinks are at a temperature of ~400 K. Two radiators will be employed to remove heat from the SEs. The SE HXs surrounding the SE heads are of annular design and have been modeled using 3-D volumes. These 3-D models have been used to improve the HX design by optimizing the flows of coolant and maximizing the heat transferred to the SE heads. The transients analyzed include failure of one or more Stirling engines, trip of the reactor pump, and trips of the secondary loop pumps feeding the HXs of the Stirling engines. Loss of one radiator sink has also been simulated. The effects of reduced gravity on the transients have also been investigated. The transients studied have been used to demonstrate the safety and the operability of the system. The results of the transients will be used to evaluate which transients the system can survive without damage and can continue operating at nominal or reduced power levels for the intended life time of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Studies for Global Nuclear Assurance and Security (GNAS): 3S Risk Analysis for Portable Nuclear Reactors (Volume II) -- Conclusions and Implications

Growing interest in compact, easily transportable sources of baseload electricity has manifested in the proposal and early deployment of portable nuclear reactors (PNRs). PNRs are sought because they are scalable, efficient, and cost-effective for meeting energy demands in unique, remote, or contested areas. For example, Russia's KLT-40S Akademik Lomonosov is a floating nuclear power plant (FNPP) that successfully reached the Arctic coastal city of Pevek. It began providing power to the local grid in December 2019. While providing such key advantages as having a highly flexible power generation mechanism, FNPPs appear to directly challenge international norms and conventions for nuclear safety, safeguards, and security. FNPPs are neither a purely fixed nuclear fuel cycle activity nor a purely transportation-based nuclear fuel cycle activity. In response, Sandia's Mitigating International Nuclear Enogy Risks (MINER) research perspective frames this discussion in terms of risk complexity and the interdependencies between safety, safeguards, and security in FNPPs, and PNRs more generally. This systems study is a technically rigorous analysis of the safety, safeguards, and security risks of FNPP technologies. This research's aims are three-fold. The first aim is to provide analytical evidence to support safety, safeguards, and security claims related to PNRs and FNPPs (Study Report Volume I). Second, this study aims to introduce a systems- theoretic approach for exploring interdependencies between the technical evaluations (Study Report Volume II). The third aim is to show Sandia's ability for prompt, rigorous, and technical analysis to support emerging complex MINER mission objectives.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

25 ENERGY STORAGE↗

System Evaluation and Economic Analysis of a Nuclear Reactor Powered High-Temperature Electrolysis Hydrogen-Production Plant

A reference design for a commercial-scale high-temperature electrolysis (HTE) plant for hydrogen production was developed to provide a basis for comparing the HTE concept with other hydrogen production concepts. The reference plant design is driven by a high-temperature helium-cooled nuclear reactor coupled to a direct Brayton power cycle. The reference design reactor power is 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 540°C and 900°C, respectively. The electrolysis unit used to produce hydrogen includes 4,009,177 cells with a per-cell active area of 225 cm2. The optimized design for the reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes an air-sweep system to remove the excess oxygen that is evolved on the anode (oxygen) side of the electrolyzer. The inlet air for the air-sweep system is compressed to the system operating pressure of 5.0 MPa in a four-stage compressor with intercooling. The alternating current (AC) to direct current (DC) conversion efficiency is 96%. The overall system thermal-to-hydrogen production efficiency (based on the lower heating value of the produced hydrogen) is 47.1% at a hydrogen production rate of 2.356 kg/s. An economic analysis of this plant was performed using the standardized H2A Analysis Methodology developed by the Department of Energy (DOE) Hydrogen Program, and using realistic financial and cost estimating assumptions. The results of the economic analysis demonstrated that the HTE hydrogen production plant driven by a high-temperature helium-cooled nuclear power plant can deliver hydrogen at a competitive cost. A cost of $3.23/kg of hydrogen was calculated assuming an internal rate of return of 10%.

08 HYDROGEN↗

Scaling Analysis for the Direct Reactor Auxiliary Cooling System for AHTRs

The Direct Reactor Auxiliary Cooling System (DRACS), shown in Fig. 1 [1], is a passive heat removal system proposed for the Advanced High-Temperature Reactor (AHTR). It features three coupled natural circulation/convection loops completely relying on the buoyancy as the driving force. A prototypic design of the DRACS employed in a 20-MWth AHTR has been discussed in our previous work [2]. The total height of the DRACS is usually more than 10 m, and the required heating power will be large (on the order of 200 kW), both of which make a full-scale experiment not feasible in our laboratory. This therefore motivates us to perform a scaling analysis for the DRACS to obtain a scaled-down model. In this paper, theory and methodology for such a scaling analysis are presented.

99 GENERAL AND MISCELLANEOUS↗

RELAP-7 Development Updates

RELAP-7 is a nuclear systems safety analysis code being developed at the Idaho National Laboratory, and is the next generation tool in the RELAP reactor safety/systems analysis application series. RELAP-7 development began in 2011 to support the Risk Informed Safety Margins Characterization (RISMC) Pathway of the Light Water Reactor Sustainability (LWRS) program. The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical methods, and physical models in order to provide capabilities needed for the RISMC methodology and to support nuclear power safety analysis. The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). The initial development goal of the RELAP-7 approach focused primarily on the development of an implicit algorithm capable of strong (nonlinear) coupling of the dependent hydrodynamic variables contained in the 1-D/2-D flow models with the various 0-D system reactor components that compose various boiling water reactor (BWR) and pressurized water reactor nuclear power plants (NPPs). During Fiscal Year (FY) 2015, the RELAP-7 code has been further improved with expanded capability to support boiling water reactor (BWR) and pressurized water reactor NPPs analysis. The accumulator model has been developed. The code has also been coupled with other MOOSE-based applications such as neutronics code RattleSnake and fuel performance code BISON to perform multiphysics analysis. A major design requirement for the implicit algorithm in RELAP-7 is that it is capable of second-order discretization accuracy in both space and time, which eliminates the traditional first-order approximation errors. The second-order temporal is achieved by a second-order backward temporal difference, and the one-dimensional second-order accurate spatial discretization is achieved with the Galerkin approximation of Lagrange finite elements. During FY-2015, we have done numerical verification work to verify that the RELAP-7 code indeed achieves 2nd-order accuracy in both time and space for single phase models at the system level.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Analysis of the Transient Reactor Test Facility (TREAT) with PROTEUS

The neutron transport code PROTEUS has been used to perform preliminary simulations of the Transient Reactor Test Facility (TREAT). TREAT is an experimental reactor designed for the testing of nuclear fuels and other materials under transient conditions. It operated from 1959 to 1994, when it was placed on non-operational standby. The restart of TREAT to support the U.S. Department of Energy’s resumption of transient testing is currently underway. Both single assembly and assembly-homogenized full core models have been evaluated. Simulations were performed using a historic set of WIMS-ANL-generated cross-sections as well as a new set of Serpent-generated cross-sections. To support this work, further analyses were also performed using additional codes in order to investigate particular aspects of TREAT modeling. DIF3D and the Monte-Carlo codes MCNP and Serpent were utilized in these studies. MCNP and Serpent were used to evaluate the effect of geometry homogenization on the simulation results and to support code-to-code comparisons. New meshes for the PROTEUS simulations were created using the CUBIT toolkit, with additional meshes generated via conversion of selected DIF3D models to support code-to-code verifications. All current analyses have focused on code-to-code verifications, with additional verification and validation studies planned. The analysis of TREAT with PROTEUS-SN is an ongoing project. This report documents the studies that have been performed thus far, and highlights key challenges to address in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Residence Time Distribution Measurement and Analysis of Pilot-Scale Pretreatment Reactors for Biofuels Production: Preprint

Measurement and analysis of residence time distribution (RTD) data is the focus of this study where data collection methods were developed specifically for the pretreatment reactor environment. Augmented physical sampling and automated online detection methods were developed and applied. Both the measurement techniques themselves and the produced RTD data are presented and discussed.

09 BIOMASS FUELS↗