Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability & Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Steam turbine: Alternative emergency drive for the secure removal of residual heat from the core of light water reactors in ultimate emergency situation

In 2011 the nuclear power generation has suffered an extreme probation. That could be the meaning of what happened in Fukushima Nuclear Power Plants. In those plants, an earthquake of 8.9 on the Richter scale was recorded. The quake intensity was above the trip point of shutting down the plants. Since heat still continued to be generated, the procedure to cooling the reactor was started. One hour after the earthquake, a tsunami rocked the Fukushima shore, degrading all cooling system of plants. Since the earthquake time, the plant had lost external electricity, impacting the pumping working, drive by electric engine. When operable, the BWR plants responded the management of steam. However, the lack of electricity had degraded the plant maneuvers. In this paper we have presented a scheme to use the steam as an alternative drive to maintain operable the cooling system of nuclear power plant. This scheme adds more reliability and robustness to the cooling systems. Additionally, we purposed a solution to the cooling in case of lacking water for the condenser system. In our approach, steam driven turbines substitute electric engines in the ultimate emergency cooling system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New Resource Adequacy Criteria for the Energy Transition: Modernizing Reliability Requirements

The transition toward a cleaner and more weather-dependent power system brings with it unprecedented challenges and opportunities for maintaining resource adequacy—namely, a future that includes rapid load growth, plant retirements, and a shift toward variable and energy-limited resources. Resource adequacy analyses, capacity accreditation, and the resource adequacy planning criteria are becoming increasingly important for power system planning and investment decisions. While previous ESIG reports evaluated the changing resource adequacy risks and planning practices created by the energy transition, none specifically examined potential changes to the resource adequacy criterion used for planning. The resource adequacy criterion sets the level of supply- and demand-side resources that are required for a given power system to meet reliability objectives. It is a pivotal standard that influences billions of dollars of investment decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DES science portal: Computing photometric redshifts

We present the Dark Energy Survey (DES) Science Portal, an integratedweb-based data interface designed to facilitate scientific analysis. Wedemonstrate how the Portal can provide a reliable environment to accesscomplete data sets, provide validation algorithms and metrics in the case ofmultiple methods and training configurations, and maintain the provenancebetween the different steps of a complex calculation, while ensuringreproducibility of the results. We use the estimation of DES photometricredshifts (photo-$z$s) as an example. A significant challenge facingphotometric surveys for cosmological purposes, such as DES, is the need toproduce reliable redshift estimates. The choice between competing algorithmsand configurations and the maintenance of an up-to-date spectroscopic databaseto build training sets, for example, are complex tasks when dealing with largeamounts of data that are regularly updated and constantly growing. We show howthe DES Science Portal can be used to train and validate several photo-$z$algorithms using the DES first year (Y1A1) data. The photo-$z$s estimated inthe Portal are used to feed the creation of catalogs for scientific workflows.While the DES collaboration is still developing techniques to obtain precisephoto-$z$s, having a structured framework like the one presented here iscritical for the systematic vetting of DES algorithmic improvements and theconsistent production of photo-$z$s in future DES releases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse contrast enhancement via non-collinear sum-frequency generation with the signal and idler of an optical parametric amplifier

We outline an approach for improving the temporal contrast of a high-intensity laser system by >8 orders of magnitude using non-collinear sum-frequency generation with the signal and idler of an optical parametric amplifier. We demonstrate the effectiveness of this technique by cleaning pulses from a millijoule-level chirped-pulse amplification system to provide >10 12 intensity contrast relative to all pre-pulses and amplified spontaneous emission >5 ps prior to the main pulse. The output maintains percent-level energy stability on the time scales of a typical user experiment at our facility, highlighting the method's reliability and operational efficiency. After temporal cleansing, the pulses are stretched in time before seeding two multi-pass, Ti:sapphire-based amplifiers. After re-compression, the 1 J, 40 fs (25 TW) laser pulses maintain a >10^10 intensity contrast >30 ps prior to the main pulse. This technique is both energy-scalable and appropriate for preparing seed pulses for a TW- or PW-level chirped-pulse amplification laser system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review and categorization of existing studies on the estimation of probabilistic failure metrics for Reactor Coolant Pressure Boundary piping and steam generator tubes in Nuclear Power Plants

This article presents the first output of the International Atomic Energy Agency (IAEA) Coordinated Research Project (CRP), titled Methodology for Assessing Pipe Failure Rates in Advanced Water-Cooled Reactors (AWCRs), launched in 2018. This IAEA CRP is aimed at developing a good-practices document for estimating the probabilistic failure metrics of piping in AWCRs. The reliability of piping that comprise the Reactor Coolant Pressure Boundary (RCPB) is important for maintaining safe and stable operations of Nuclear Power Plants (NPPs) because failure of those piping components could lead to undesirable consequences, such as plant shutdown, costly repair, the occurrence of Loss-of-Coolant Accidents (LOCAs) and, possibly, subsequent core damage or large release events. Probabilistic failure metrics (e.g., failure rate, failure frequency, or failure probability) of RCPB components are the key inputs to the Probabilistic Safety/Risk Assessment (PSA/PRA) and risk management of NPPs. The estimation of probabilistic failure metrics, however, is challenging, especially for AWCRs, due to the lack of operating experience. Therefore, as the first step of the IAEA CRP activities, this paper is developed to provide a literature review of the existing studies (from 2000 to April 2019) on the estimation of probabilistic failure metrics for RCPB piping and Steam Generator (SG) tubes of NPPs and to categorize them based on four criteria: (1) explicitness of incorporation of physical failure mechanisms; (2) types of failure characterization; (3) types of physical models for degradation; and (4) explicitness of consideration of maintenance. The existing studies are also analyzed from the viewpoint of the following key aspects: (i) uncertainty analysis, (ii) sensitivity analysis, (iii) validation strategies, and (iv) the areas of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Remote Communications Link to Reduce Residential PV Solar Costs

Monitoring of PV/DER site production is expensive to install and unreliable. Among third party systems providers, lost communications links are a growing concern. Nearly 20% of links are failing, provisioning is complex, recovery is expensive, production data is lost, and access is fragmented. FleetLink is a new concept in DER system communications, purpose built for lowering the cost of maintaining active contact with residential end user sites and ensuring that production data is reliably available to third party systems providers. Systems providers require accurate, secure system monitoring and reporting of production data and system faults while driving down overall costs to compete effectively. This plug and play, independently operating communications solution lowers the cost of fleet contact from typically .08 dollars-$.12/W down to .02 dollars -.03/W including installation and maintenance expenses. FleetLink establishes a breakthrough in simplicity that facilitates rapid expansion of residential solar by reducing initial capital outlay and lowering installation labor time and skill levels. The solution also facilitates higher DER installation growth rates by driving down maintenance costs and eliminating communications trouble calls. This is accomplished by the FleetLink’s unique network technology that enables dynamic network configuration for fast changes, and active, self-healing DER site contact for uptime assurance. Using an open source network framework with proprietary, application specific enhancements, FleetLink independently manages connectivity, security, recovery, grid control communications, and fleet expansion while presenting a compliant SunSpec interface to the third party operations centers. The net system cost savings of at least .05 dollars/W supports the SunShot cost goals and the flexibility and scalability of the solution accelerates the velocity and ubiquitous adoption of solar.

14 SOLAR ENERGY↗

Weather-Driven Resilience for Distribution Systems

With increasing billion dollar disasters due to weather events, it is of utmost priority for utility and grid operators to maintain and enhance the resilience of distribution grid. Traditionally, such analysis were conducted with reliability metrics alone. However, with increasing complexity of distribution grid and advancements in grid edge resources, evaluating grid resilience is challenging and involves multi-faceted analysis of the impact of weather events on the distribution grid. This presentation provides background, details, and future works in the field of weather-driven resilience for power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cold Climates Heat Pump Design Optimization

Heat pumps provide an efficient heating method; however they suffer from sever capacity and performance degradation at low ambient conditions. This has deterred market penetration in cold climates. There is a continuing effort to find an efficient air source cold climate heat pump that maintains acceptable capacity and performance at low ambient conditions. Systematic optimization techniques provide a reliable approach for the design of such systems. This paper presents a step-by-step approach for the design optimization of cold climate heat pumps. We first start by describing the optimization problem: objective function, constraints, and design space. Then we illustrate how to perform this design optimization using an open source publically available optimization toolbox. The response of the heat pump design was evaluated using a validated component based vapor compression model. This model was treated as a black box model within the optimization framework. Optimum designs for different system configurations are presented. These optimum results were further analyzed to understand the performance tradeoff and selection criteria. The paper ends with a discussion on the use of systematic optimization for the cold climate heat pump design.

Abdelaziz, Omar↗

Measuring Sustainability of Solar Modules for Energy Transition: Mass, Energy, and Circularity

Transition to a carbon-free energy system is crucial for global decarbonization and underpins Circular Economy (CE) goals. Photovoltaic (PV) technology is required for Energy Transition, but manufacturing and circular pathways can be material, energy, and carbon-intensive. Therefore, we need a prioritization of sustainability strategies for PV evolution and lifecycle management in the context of Energy Transition. This study employs a suite of quantitative metrics to compare different proposed sustainability strategies for PV modules on their ability to achieve Energy Transition. Proposals for sustainable PV range from high-yield, high-efficiency paradigms, to short-lived and fully recyclable, to long-lasting, indestructible modules. We leverage a global decarbonization deployment schedule through 2100 with the open-source PV in Circular Economy (PV ICE) tool to quantify the impacts of different evolving module design scenarios covering the range of proposed sustainability strategies. First, modules are compared on effective capacity and required replacements to meet and maintain decarbonization capacity targets through 2100. We demonstrate the effects of lifetime, degradation, and reliability on effective capacity. Next, we quantify and compare virgin material demands and lifecycle wastes, examining the impacts of lifetime and recycling rates. Finally, and critically for renewable energy technologies, we quantify the energy demands required to achieve the decarbonization capacity targets and calculate energy balance metrics (net energy, energy return on investment). These results are then summarized into a metric matrix, demonstrating tradeoffs and the importance of longevity. Our suite of mass and energy metrics provides stakeholders and decision-makers with quantitative data on circular economy choices for PV in the energy transition, enabling informed evaluation of tradeoffs of different PV module designs and CE pathways.

circular economy↗

Temperature and vital effect controls on Bamboo coral (Isididae) isotopegeochemistry: A test of the "lines method"

Deep-sea bamboo corals hold promise as long-term climatic archives, yet little information exists linking bamboo coral geochemistry to measured environmental parameters. This study focuses on a suite of 10 bamboo corals collected from the Pacific and Atlantic basins (250-2136 m water depth) to investigate coral longevity, growth rates, and isotopic signatures. Calcite samples for stable isotopes and radiocarbon were collected from the base the corals, where the entire history of growth is recorded. In three of the coral specimens, samples were also taken from an upper branch for comparison. Radiocarbon and growth band width analyses indicate that the skeletal calcite precipitates from ambient dissolved inorganic carbon and that the corals live for 150-300 years, with extension rates of 9-128 {micro}m/yr. A linear relationship between coral calcite {delta}{sup 18}O and {delta}{sup 13}C indicates that the isotopic composition is influenced by vital effects ({delta}{sup 18}O:{delta}{sup 13}C slope of 0.17-0.47). As with scleractinian deep-sea corals, the intercept from a linear regression of {delta}{sup 18}O versus {delta}{sup 13}C is a function of temperature, such that a reliable paleotemperature proxy can be obtained, using the 'lines method.' Although the coral calcite {delta}{sup 18}O:{delta}{sup 13}C slope is maintained throughout the coral base ontogeny, the branches and central cores of the bases exhibit {delta}{sup 18}O:{delta}{sup 13}C values that are shifted far from equilibrium. We find that a reliable intercept value can be derived from the {delta}{sup 18}O:{delta}{sup 13}C regression of multiple samples distributed throughout one specimen or from multiple samples within individual growth bands.

58 GEOSCIENCES↗

A Short-Term Solar Forecasting Platform Using a Physics-Based Smart Persistence Model and Data Imputation Method

Electrical energy plays vital role in our socio-economic activity and therefore ensuring the reliability of the electric grid, from the generation, transmission and distribution level is critical. In order to maintain the power system parameter viz., frequency, voltage, etc., optimally, balancing of generation and consumption is very much essential. However, solar energy is infirm power by nature this is due to cloud cover / other local phenomena. Hence, Photovoltaic (PV) power generation brings a significant challenge to the grid operator due to the variability of the solar energy. The complexity of this challenge in terms of planning and dispatch ability of PV resources, aggravates with the high penetration of solar energy into the electric grid. In this setting, reliable solar radiation forecasting models based on accurate and quality input data become essential. In order to develop a suitable model for predicting solar radiation, quality historical / real time measurement is also needed. Under this study NIWE and NREL jointly developed / tested short-term solar forecasting frameworks using a smart persistence and physics-based smart persistence models for intra-hour forecasting of solar radiation (PSPI) and benchmarked 9 different data imputation techniques in 15 Solar Radiation Resource Assessment (SRRA) stations, located at different parts of India. During any measurement campaign, due to various technical reasons, we may miss few observations. However, the missing observation often reduce the performance of any forecasting model. Therefore, suitable data imputation method would assist us to obtain continuous observation of solar radiation. A station-by-station and method-by-method analysis was carried out to understand the performance of each model. Based on our analysis, among all the data imputation methods, the Kalman data imputation method is better for Indian Weather condition. In addition, Kalman StructTS, Linear, Stine and Arima methods yield slightly inferior accuracy compared to Kalman, but outperform the other methods. The extended solar radiation data are used by solar forecasting models to provide the prediction of solar radiation at 15 SRRA stations. As far as short term forecasting model is concerned, the PSPI model outperforms the Smart Persistence model. However, the forecast error is increases with the forecasting horizon.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Imputation of urban environmental sensor data using gated attention bidirectional long short-term memory (GA-BiLSTM): methods, performance, and implications

Urban environmental monitoring networks frequently encounter significant data gaps due to sensor malfunctions, environmental disturbances, and communication failures. Reliable approaches to address these gaps are essential for ensuring the continuity and quality of environmental data streams. In this study, we developed a gated attention bidirectional long short-term memory (GA-BiLSTM) model to impute missing data in a dense urban monitoring network. Using observations from the CROCUS network in Chicago, we evaluated GA-BiLSTM against widely used approaches (XGBoost and K-nearest neighbors) under scenarios of both short-term intermittent gaps and prolonged outages. GA-BiLSTM consistently outperformed comparative methods, particularly during extended outages of up to ten days, demonstrating its ability to capture spatiotemporal dependencies across sensor nodes. Beyond performance metrics, feature importance and spatial network analyses highlighted the unexpected but critical predictive role of peripheral rural nodes, underlining their strategic value for maintaining robust urban monitoring systems. These results emphasize that advanced imputation methods can substantially improve the reliability of environmental monitoring networks and support more resilient data infrastructures for urban sustainability.

Data imputation↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

A portable cryostat for the cold transfer of polarized solid HD targets: HDice-I

We developed a device with moveable liquid nitrogen and liquid helium volumes that is capable of reaching over 2 m into the coldest regions of a cryostat or dilution refrigerator and reliably extracting or installing a target of solid, polarized hydrogen deuteride (HD). This Transfer Cryostat incorporates a cylindrical neodymium rare-earth magnet that is configured as a Halbach dipole, which is maintained at 77 K and produces a 0.1 T field around the HD target. Multiple layers provide a hermetic 77 K-shield as the device is used to maintain a target at 2 K during a transfer between cryostats. Our tests with frozen-spin HD show very little polarization loss for either H (-1±2%, relative) or D (0±3%, relative) over typical transfer periods. Multiple target transfers with this apparatus have shown an overall reliability of about 95% per transfer, which is a significant improvement over earlier versions of the device.

42 ENGINEERING↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Is Radiotherapy a Good Adjuvant Strategy for Men With a History of Cryptorchism and Stage I Seminoma?

Purpose: Men with cryptorchism can have aberrant abdominopelvic lymph node (LN) drainage or a different natural history if they develop Stage I seminoma. If so, the nodal echelons for metastases will not be reliable, and adjuvant radiotherapy (RT) would not be an ideal strategy. Methodsand Materials: Two prospectively maintained oncology databases were reviewed for men with a history of testicular seminoma and cryptorchidism. The primary endpoint was the 5-year relapse-free rate. Results: A total of 23 men were identified, most (n = 13) had had a tumor in a scrotal location after orchiopexy. After orchiectomy, 5 men were managed with surveillance, and 18 underwent RT to a median dose of 25 Gy (range, 20-30 Gy). All the radiation fields included the para-aortic LNs, and 13 included the ipsilateral pelvic LNs. After a median follow-up of 64 months (range, 2-148), 2 patients developed a relapse. One did so 4 months into a surveillance program in the para-aortic and ipsilateral pelvic LNs, sites that would have been treated had he undergone RT. The other patient developed a relapse in the contralateral testis 46 months after having undergone RT. It is likely that the latter patient had a metachronous primary rather than a relapse; hence, the 5-year relapse-free rate was 80% for surveillance and 100% for RT. Both patients underwent successful salvage treatment, and all patients were disease free and alive at the last follow-up visit. Conclusion: A history of cryptorchism does not appear to confer a greater risk of relapse for men with Stage I seminoma managed with radiotherapy. RT, surveillance, and adjuvant carboplatin chemotherapy are treatment options for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unraveling the advances of trace doping engineering for potassium ion battery anodes via tomography

Doping have been considered as a prominent strategy to stabilize crystal structure of battery materials during the insertion and removal of alkali ions. The instructive knowledge and experience acquired from doping strategies predominate in cathode materials, but doping principle in anodes remains unclear. Here, we demonstrate that trace element doping enables stable conversion-reaction and ensures structural integrity for potassium ion battery (PIB) anodes. With a synergistic combination of X-ray tomography, structural probes, and charge reconfiguration, we encode the physical origins and structural evolution of electro-chemo-mechanical degradation in PIB anodes. By the multiple ion transport pathways created by the orderly hierarchical pores from “surface to bulk” and the homogeneous charge distribution governed in doped nanodomains, the anisotropic expansion can be significantly relieved with trace isoelectronic element doping into the host lattice, maintaining particle mechanical integrity. Our work presents a close relationship between doping chemistry and mechanical reliability, projecting a new pathway to reengineering electrode materials for next-generation energy storage.

25 ENERGY STORAGE↗

Frequency Response Tool

According to the North American Electric Reliability Corporation (NERC) definition: "Frequency response is a measure of an Interconnection's ability to stabilize frequency immediately following the sudden loss of generation or load, and is a critical component of the reliable operation of the Bulk-Power System, particularly during disturbances and recoveries. Failure to maintain frequency can disrupt the operation of equipment and initiate disconnection of power plant equipment to prevent it from being damaged, which could lead to wide-spread blackouts." Frequency Response Tool automates the power system frequency response analysis process. The tool performs initial estimation of the system frequency parameters (initial frequency, minimum frequency, settling point). User can visually inspect and adjust these parameters. The tool also calculates the frequency response performance metrics of the system, archives the historic events and baselines the system performance. Frequency response performance characteristics of the system are calculated using phasor measurement unit (PMU) information. Methodology of the frequency response performance assessment implemented in the tool complies with the NERC Frequency response standard.

Etingov, Pavel↗