Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repair”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Purification, crystallization and preliminary X-ray diffraction analysis of the human mismatch repair protein MutS[beta]

MutS{beta} is a eukaryotic mismatch repair protein that preferentially targets extrahelical unpaired nucleotides and shares partial functional redundancy with MutS{alpha} (MSH2-MSH6). Although mismatch recognition by MutS{alpha} has been shown to involve a conserved Phe-X-Glu motif, little is known about the lesion-binding mechanism of MutS{beta}. Combined MSH3/MSH6 deficiency triggers a strong predisposition to cancer in mice and defects in msh2 and msh6 account for roughly half of hereditary nonpolyposis colorectal cancer mutations. These three MutS homologs are also believed to play a role in trinucleotide repeat instability, which is a hallmark of many neurodegenerative disorders. The baculovirus overexpression and purification of recombinant human MutS{beta} and three truncation mutants are presented here. Binding assays with heteroduplex DNA were carried out for biochemical characterization. Crystallization and preliminary X-ray diffraction analysis of the protein bound to a heteroduplex DNA substrate are also reported.

59 BASIC BIOLOGICAL SCIENCES↗

Base Excision Repair: Mechanisms and Impact in Biology, Disease, and Medicine

Base excision repair (BER) corrects forms of oxidative, deamination, alkylation, and abasic single-base damage that appear to have minimal effects on the helix. Since its discovery in 1974, the field has grown in several facets: mechanisms, biology and physiology, understanding deficiencies and human disease, and using BER genes as potential inhibitory targets to develop therapeutics. Within its segregation of short nucleotide (SN-) and long patch (LP-), there are currently six known global mechanisms, with emerging work in transcription- and replication-associated BER. Knockouts (KOs) of BER genes in mouse models showed that single glycosylase knockout had minimal phenotypic impact, but the effects were clearly seen in double knockouts. However, KOs of downstream enzymes showed critical impact on the health and survival of mice. BER gene deficiency contributes to cancer, inflammation, aging, and neurodegenerative disorders. Medicinal targets are being developed for single or combinatorial therapies, but only PARP and APE1 have yet to reach the clinical stage.

5′-Gap↗

The DNA repair endonuclease XPG interacts directly and functionally with the WRN helicase defective in Werner syndrome

XPG is a structure-specific endonuclease required for nucleotide excision repair (NER). XPG incision defects result in the cancer-prone syndrome xeroderma pigmentosum, whereas truncating mutations of XPG cause the severe postnatal progeroid developmental disorder Cockayne syndrome. We show that XPG interacts directly with WRN protein, which is defective in the premature aging disorder Werner syndrome, and that the two proteins undergo similar sub-nuclear redistribution in S-phase and co-localize in nuclear foci. The co-localization was observed in mid- to late-S-phase, when WRN moves from nucleoli to nuclear foci that have been shown to contain protein markers of both stalled replication forks and telomeric proteins. We mapped the interaction between XPG and WRN to the C-terminal domains of each and show that interaction with the C-terminal domain of XPG strongly stimulates WRN helicase activity. WRN also possesses a competing DNA single-strand annealing activity that, combined with unwinding, has been shown to coordinate regression of model replication forks to form Holliday junction/chicken foot intermediate structures. We tested whether XPG stimulated WRN annealing activity and found that XPG itself has intrinsic strand annealing activity that requires the unstructured R- and C-terminal domains, but not the conserved catalytic core or endonuclease activity. Annealing by XPG is cooperative, rather than additive, with WRN annealing. Taken together, our results suggest a novel function for XPG in S-phase that is at least in part carried out coordinately with WRN, and which may contribute to the severity of the phenotypes that occur upon loss of XPG.

59 BASIC BIOLOGICAL SCIENCES↗

Is Internal Iliac Artery Embolization Essential Prior to Endovascular Repair of Aortoiliac Aneurysms?

Patients who undergo endovascular repair of aorto-iliac aneurysms (EVAR) require internal iliac artery (IIA) embolization (IIAE) to prevent type II endoleaks after extending the endografts into the external iliac artery. However, IIAE may not be possible in some patients due to technical factors or adverse anatomy. The aim of this study was to assess retrospectively whether patients with aorto-iliac aneurysms who fail IIAE have an increase in type II endoleak after EVAR compared with similar patients who undergo successful embolization. We retrospectively analyzed the records of 148 patients who underwent EVAR from December 1997 to June 2005. Sixty-one patients had aorto-iliac aneurysms which required IIAE before EVAR. Fifty patients had successful IIAE and 11 patients had unsuccessful IIAE prior to EVAR. The clinical and imaging follow-up was reviewed before and after EVAR. The endoleak rate of the embolized group was compared with that of the group in whom embolization failed. After a mean follow-up of 19.7 months in the study group and 25 months in the control group, there were no statistically significant differences in outcome measures between the two groups. Specifically, there were no type II endoleaks related to the IIA in patients where IIAE had failed. We conclude that failure to embolize the IIA prior to EVAR should not necessarily preclude patients from treatment. In patients where there is difficulty in achieving coil embolization, it is recommended that EVAR should proceed, as clinical sequelae are unlikely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Sac Rupture in Abdominal Aortic Aneurysms Previously Excluded with Endovascular Repair (EVAR)

The purpose of this study was to assess the feasibility and effectiveness of percutaneous endovascular repair of ruptured abdominal aortic aneurysms (AAAs) previously treated by EVAR. In the last year, two male patients with AAAs, treated 8 and 23 months ago with bifurcated stent-graft, were observed because of lumbar pain and hemorragic shock. Multidetector computed tomography (MDCT) showed a retroperitoneal hematoma; in both cases a type III endoleak was detected, in one case associated with a type II endoleak from the iliolumbar artery. The procedures were performed in the theater, in emergency. Type II endoleak was treated with transcatheter superselective glue injection; type III endoleaks were excluded by a stent-graft extension. The procedures were successful in both patients, with immediate hemodynamic stabilization. MDCT after the procedure showed complete exclusion of the aneurysms. In conclusion, endovascular treatment is a safe and feasible option for the treatment of ruptured AAAs previously treated by EVAR; this approach allows avoidance of surgical conversion, which is technical very challenging, with a high morbidity and mortality rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory Displacement of the Thoracic Aorta: Physiological Phenomenon With Potential Implications for Thoracic Endovascular Repair

The purpose of this study was to assess the magnitude and direction of respiratory displacement of the ascending and descending thoracic aorta during breathing maneuvers. In 11 healthy nonsmokers, dynamic magnetic resonance imaging was performed in transverse orientation at the tracheal bifurcation during maximum expiration and inspiration as well as tidal breathing. The magnitude and direction of aortic displacement was determined relatively to resting respiratory position for the ascending (AA) and descending (DA) aorta. To estimate a respiratory threshold for occurrence of distinct respiratory aortic motion, the latter was related to the underlying change in anterior-posterior thorax diameter. Compound displacement between maximum expiration and inspiration was 24.3 {+-} 6.0 mm for the AA in the left anterior direction and 18.2 {+-} 5.5 mm for the DA in the right anterior direction. The mean respiratory thorax excursion during tidal breathing was 8.9 {+-} 2.8 mm. The respiratory threshold, i.e., the increase in thorax diameter necessary to result in respiratory aortic displacement, was estimated to be 15.7 mm. The data suggest that after a threshold of respiratory thorax excursion is exceeded, respiration is accompanied by significant displacement of the thoracic aorta. Although this threshold may not be reached during tidal breathing in the majority of individuals, segmental differences during forced respiration impact on aortic geometry, may result in additional extrinsic forces on the aortic wall, and may be of significance for aortic prostheses designed for thoracic endovascular aortic repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Repair of Abdominal Aortic Aneurysm: Effectiveness of Embolization

The purpose of this study was to report our experience in treating type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. Two hundred eighteen patients underwent EVAR with a Zenith stent-graft from January 2000 to December 2005. During a follow-up period of 4.5 {+-} 2.3 years, solely type II endoleak was detected in 47 patients (22%), and 14 of them underwent secondary interventions to correct this condition. Ten patients had transarterial embolization, and four patients had translumbar/transabdominal embolization. The embolization materials used were coils, thrombin, gelatin, Onyx (ethylene-vinyl alcohol copolymer), and glue. Disappearance of the endoleak without enlargement of the aneurysm sac after the first secondary intervention was achieved in only five of these patients (5/13). One patient without surveillance imaging was excluded from analyses of clinical success. After additional interventions in four patients and the spontaneous disappearance of type II endoleak in two patients, overall clinical success was achieved in eight patients (8/12). One patient did not have surveillance imaging after the second secondary intervention. Clinical success after the first secondary intervention was achieved in two patients (2/9) in the transarterial embolization group and three patients (3/4) in the translumbar embolization group. The results of secondary interventions for type II endoleak are unsatisfactory. Although the small number of patients included in this study prevents reliable comparisons between groups, the results seem to favor direct translumbar embolization in comparison to transarterial embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Delayed Complete Graft Thrombosis After Endovascular Aneurysm Repair

Graft thrombosis rates after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms vary widely in published series. When thrombosis does occur, it usually involves a single limb and occurs within 3 months of stent-graft insertion. If the entire endoprosthesis is thrombosed, treatment may be challenging because femoro-femoral crossover graft insertion is not an option and a greater volume of thrombus is present, thus making thrombolysis more difficult. We present two cases of delayed thrombosis after EVAR involving the entire stent-graft. These were successfully treated by a combined surgical and endovascular technique, and patency has been maintained in both cases to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lethal Hemorrhage Caused by Aortoesophageal Fistula Secondary to Stent-Graft Repair of the Thoracic Aorta

Aortoesophageal fistula (AEF) is a rare but life-threatening complication after endovascular or surgical aortic repair. Here we report a patient with AEF secondary to aortic stent-placement 2 years earlier who presented with hematemesis and died from hemorrhagic shock. By means of this case and the literature, we highlight potential bleeding sources in such a scenario because this is of crucial importance for the management strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Type II Endoleak After Endovascular Aortic Repair: Comparison Between Magnetic Resonance Angiography and Blood-Pool Contrast Agent and Dual-Phase Computed Tomography Angiography

PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type II was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size ({>=}20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolisation of a Proximal Type I Endoleak Post-Nellix Aortic Aneurysm Repair Complicated by Reflux of Onyx into the Nellix Endograft Limb

We report the first case of intervention for a proximal type 1 endoleak following Nellix endovascular aneurysm sealing repair of an aortic aneurysm. This was complicated by migration of Onyx into one of the Nellix graft limbs causing significant stenosis. Subsequent placement of a covered stent to affix the Onyx between the stent and the wall of the Nellix endograft successfully restored stent patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Compliance with Surveillance Following Elective Endovascular Aneurysm Repair

PurposeIntegral to maintaining good outcomes post-endovascular aneurysm repair (EVAR) is a robust surveillance protocol. A significant proportion of patients fail to comply with surveillance, exposing themselves to complications. We examine EVAR surveillance in Wessex (UK), exploring factors that may predict poor compliance.MethodsRetrospective analysis of 179 consecutive elective EVAR cases [2008–2013] was performed. 167 patients were male, with the age range of 50–95. Surveillance was conducted centrally (tertiary referral trauma centre) and at four spoke units. Surveillance compliance and predictors of non-compliance including age, gender, co-morbid status, residential location and socioeconomic status were analysed for univariate significance.ResultsFifty patients (27.9 %) were non-compliant with surveillance; 14 (8.1 %) had no imaging post-EVAR. At 1 year, 56.1 % (of 123 patients) were compliant. At years 2 and 3, 41.5 and 41.2 % (of 65 and 34 patients, respectively) were compliant. Four years post-EVAR, only one of eight attended surveillance (12.5 %). There were no statistically significant differences in age (p = 0.77), co-morbid status or gender (p = 0.64). Distance to central unit (p = 0.67) and surveillance site (p = 0.56) was non-significant. While there was a trend towards compliance in upper-middle-class socioeconomic groups (ABC1 vs. C1C2D), correlating with >50 % of non-compliant patients living within <10 mile radius of the central unit, overall predictive value was not significant (p = 0.82).ConclusionsCompliance with surveillance post-EVAR is poor. No independent predictor of non-compliance has been confirmed, but socioeconomic status appears to be relevant. There is a worrying drop-off in attendance beyond the first year. This study highlights a problem that needs to be addressed urgently, if we are to maintain good outcomes post-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair

PurposeTo assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR).Materials and MethodsWe performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks.ResultsData were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of <0.638 or ≥0.638, respectively (P = .002).ConclusionPatients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗