Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Semiclassical nonlinear response functions for coupled anharmonic vibrations

Observables in linear and nonlinear infrared spectroscopy may be computed from vibrational response functions describing nuclear dynamics on a single electronic surface. We demonstrate that the Herman-Kluk (HK) semiclassical approximation to the quantum propagator yields an accurate representation of quantum coherence effects in linear and nonlinear response functions for coupled anharmonic oscillators. A considerable numerical price is paid for this accuracy; the calculation requires a multidimensional integral over a highly oscillatory integrand that also grows without bound as a function of evolution times. The interference among classical trajectories in the HK approximation produces quantization of good action variables. By treating this interference analytically, we develop a mean-trajectory (MT) approximation that requires only the propagation of classical trajectories linked by transitions in action. The MT approximation accurately reproduces coherence effects in response functions of coupled anharmonic oscillators in a regime in which the observables are strongly influenced by these interactions among vibrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulations of Material-Dependent Detector Responses for Airborne Gamma-Ray Spectroscopy

The aim of this work is to create a library of predicted detector responses used for real-time background estimation during airborne gamma-ray spectroscopy. The simulated spectra are a function of naturally occurring radioactive potassium, uranium, and thorium (KUT) and radioactive daughter products which are present in terrestrial-based materials. Self-attenuation within these materials varies, such that the gamma spectra emitted from the surfaces can differ, despite all having KUT origins. This study also compared various simulated detector responses among materials to determine if some could be accurately scaled from another across reasonable helicopter altitudes and orientations, relative to the ground. Results show that materials with comparable sample thicknesses can be scaled consistently across altitude. This work allows for efficient background estimation via aggregation of simulated detector responses in real time.

radioactive potassium, uranium, and thorium, KUT, ↗

Simulation of Energy Response of the ATIC Calorimeter

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. For reconstruction of primary spectra from spectra of energy deposits measured in the experiment, correlations between kinetic energy of a primary particle E(sub kin) and energy deposit in the calorimeter E(sub d) should be known. For this purpose, simulations of energy response of the calorimeter on energy spectra of different nuclei were done. The simulations were performed by GEANT-3.21 code with QGSM generator for nucleus - nucleus interactions. The incident flux was taken as isotropic in the ATIC aperture. Primary spectra power-law by momentum were used as inputs according to standard models of cosmic ray acceleration. These spectra become power-law by kinetic energy at E(sub kin) higher than approx.20Mc(sup 2), where M is primary nucleus mass. It should be noted that energy deposit spectra measured by ATIC illustrate similar behavior. Distributions of ratio E(sub kin)/E(sub d) are presented for different energy deposits and for a set of primaries. For power-law regions of energy spectra at E(sub d)> or equal to 20Mc(sup 2) the obtained mean value of E(sub kin)/E(sub d) increases from approx.2.4 for protons to approx.3.1 for iron, while rms/ decreases from 50% for protons to about 15% for iron. These values were obtained for the spectral index gamma=1.6

Batkov, K. E.↗

A generalized modal shock spectra method for spacecraft loads analysis

Unlike an earlier shock spectra approach, generalization permits an accurate elastic interaction between the spacecraft and launch vehicle to obtain accurate bounds on the spacecraft response and structural loads. In addition, the modal response from a previous launch vehicle transient analysis with or without a dummy spacecraft - is exploited to define a modal impulse as a simple idealization of the actual forcing function. The idealized modal forcing function is then used to derive explicit expressions for an estimate of the bound on the spacecraft structural response and forces. Greater accuracy is achieved with the present method over the earlier shock spectra, while saving much computational effort over the transient analysis.

Trubert, M.↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

THE NON-UNIVERSALITY OF THE LOW-MASS END OF THE IMF IS ROBUST AGAINST THE CHOICE OF SSP MODEL

We perform a direct comparison of two state-of-the art single stellar population (SSP) models that have been used to demonstrate the non-universality of the low-mass end of the initial mass function (IMF) slope. The two public versions of the SSP models are restricted to either solar abundance patterns or solar metallicity, too restrictive if one aims to disentangle elemental enhancements, metallicity changes, and IMF variations in massive early-type galaxies (ETGs) with star formation histories different from those in the solar neighborhood. We define response functions (to metallicity and α-abundance) to extend the parameter space for each set of models. We compare these extended models with a sample of Sloan Digital Sky Survey (SDSS) ETG spectra with varying velocity dispersions. We measure equivalent widths of optical IMF-sensitive stellar features to examine the effect of the underlying model assumptions and ingredients, such as stellar libraries or isochrones, on the inference of the IMF slope down to ∼0.1 M{sub ⊙}. We demonstrate that the steepening of the low-mass end of the IMF based on a non-degenerate set of spectroscopic optical indicators is robust against the choice of the stellar population model. Although the models agree in a relative sense (i.e., both imply more bottom-heavy IMFs for more massive systems), we find non-negligible differences in the absolute values of the IMF slope inferred at each velocity dispersion by using the two different models. In particular, we find large inconsistencies in the quantitative predictions of the IMF slope variations and abundance patterns when sodium lines are used. We investigate the possible reasons for these inconsistencies.

79 ASTRONOMY AND ASTROPHYSICS↗

FRAM Isotopic Analysis of High-Resolution CZT Data

H3D Inc. has introduced a new type of CZT detectors that has resolution several times better than that of a typical, single crystal CZT detector. The better resolution has made it easier for software codes to analyze its spectra for isotopic composition of nuclear materials. The Fixed-energy Response-function Analysis with multiple efficiency (FRAM) is one of such software codes. The good peak resolution of the H3D CZT detectors allows the current FRAM v.6.1 and earlier to successfully analyze uranium spectra with minimal modification of the parameter sets and get reasonable results. (A parameter set governs how an analysis is performed.) The exceptionally large high-energy tail of the peaks makes it difficult to achieve good uranium results and impossible to successfully analyze plutonium spectra. The FRAM code needed to be modified to better fit the high-energy tail of the peaks in order to analyze plutonium data and to get better uranium analysis results. Results of this modification, encoded in beta version FRAM v.7.0i, are reported herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-329: Tissue-Equivalent Phantom Materials for Neutron Dosimetry in Proton Therapy

Purpose: To characterize tissue equivalence of phantom materials in terms of secondary neutron production and dose deposition from neutrons produced in radiation therapy phantom materials in the context of proton therapy using Monte Carlo simulations and measurements. Methods: In order to study the influence of material choice on neutron production in therapeutic proton beams, Monte Carlo simulations using the Geant4 and MCNPX-PoliMi transport codes were performed to generate the neutron fields produced by protons of 155 and 200 MeV. A simple irradiation geometry was used to investigate the effect of different materials. The proton beams were stopped in slab phantoms to study the production of secondary neutrons. The investigated materials were water, Lucite, and tissue-equivalent phantom materials (CIRS Inc., Norfolk, VA). Neutron energy spectra and absorbed dose by neutrons and their secondary particles were scored. In addition, simulations were performed for reference tissues (ICRP/ICRU) to assess tissue equivalence with respect to neutron generation and transport. In order to benchmark the simulation results, measurements were performed with a system developed at the University of Michigan; organic liquid scintillators were used to detect the neutron emissions from the irradiation of tissue-equivalent materials. Additionally, the MPPost code was used to calculate the scintillator response from the MCNPX-PoliMi output. Results: The simulated energy spectra and depth dose curves of the neutrons produced in different phantom materials showed similar shape. The differences of spectra and fluences between all studied materials and reference tissues were well within the achievable precision of neutron dosimetry. The shape of the simulated detector response of the liquid scintillators agreed well with measurements on the proton beamline. Conclusion: Based on Geant4 and MCNPX-PoliMi simulations, the investigated materials appear to be suitable to study the production of neutrons in proton therapy. MC simulations were verified with neutron measurements in therapeutic proton beams. This work was funded in part by the ANDANTE grant of the European Commission in the 7th Framework Program.

07 ISOTOPE AND RADIATION SOURCES↗

Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV)

Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For use in brachytherapy, beam quality correction factors are needed, which include corrections for differences in mass energy absorption properties between water and detector as well as variations in detector response (intrinsic efficiency) with radiation quality, caused by variations in the density of ionization (linear energy transfer (LET) -distributions) along the secondary electron tracks. The aim of this work was to investigate experimentally the detector response of LiF:Mg,Ti thermoluminescent dosimeters (TLD) for photon energies below 1 MeV relative to {sup 60}Co and to address discrepancies between the results found in recent publications of detector response. Methods: LiF:Mg,Ti dosimeters of formulation MTS-N Poland were irradiated to known values of air kerma free-in-air in x-ray beams at tube voltages 25-250 kV, in {sup 137}Cs- and {sup 60}Co-beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free-in-air into values of mean absorbed dose in the dosimeters in the actual irradiation geometries were made using EGSnrc Monte Carlo simulations. X-ray energy spectra were measured or calculated for the actual beams. Detector response relative to that for {sup 60}Co was determined at each beam quality. Results: An increase in relative response was seen for all beam qualities ranging from 8% at tube voltage 25 kV (effective energy 13 keV) to 3%-4% at 250 kV (122 keV effective energy) and {sup 137}Cs with a minimum at 80 keV effective energy (tube voltage 180 kV). The variation with effective energy was similar to that reported by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with our values being systematically lower by 2%-4%. Compared to the results by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], the relative detector response as a function of effective energy differed in both shape and magnitude. This could be explained by the higher maximum read-out temperature (350 deg. C) used by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], allowing light emitted from high-temperature peaks with a strong LET dependence to be registered. Use of TLD-100 by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with a stronger super-linear dose response compared to MTS-N was identified as causing the lower relative detector response in this work. Conclusions: Both careful dosimetry and strict protocols for handling the TLDs are required to reach solid experimental data on relative detector response. This work confirms older findings that an over-response relative to {sup 60}Co exists for photon energies below 200-300 keV. Comparison with the results from the literature indicates that using similar protocols for annealing and read-out, dosimeters of different makes (TLD-100, MTS-N) differ in relative detector response. Though universality of the results has not been proven and further investigation is needed, it is anticipated that with the use of strict protocols for annealing and read-out, it will be possible to determine correction factors that can be used to reduce uncertainties in dose measurements around brachytherapy sources at photon energies where primary standards for absorbed dose to water are not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orientation of Ferroelectric Domains and Disappearance upon Heating Methylammonium Lead Triiodide Perovskite from Tetragonal to Cubic Phase

We study the spontaneous polarization of the archetypal semiconducting halide perovskite methylammonium lead triiodide (CH 3 NH 3 PbI 3 ) that is currently being investigated for use in thin film solar cells and light-emitting diodes. Using both lateral and vertical piezoresponse force microscopy (PFM) to image polycrystalline thin films, we observed domains in the piezoresponse that reversibly appear and disappear below and above the tetragonal-to-cubic phase transition temperature. Importantly, we observe these domains to exhibit a piezoresponse that is predominantly in-plane for films with the (110) plane oriented parallel to the substrate, providing a measure of the polarization associated with specific crystal planes. We characterize the polarization and its temporal response using both local switching spectroscopy and time-dependent PFM spectra. These data show hysteresis loops with the polarization switching with bias but relaxing back on time scales of several minutes. Furthermore, our results suggest the existence of ferroelectric behavior due to off-center displacement of the Pb 2+ cation, although the local polarization response is complicated by the presence of local ionic and electronic conductivity. Understanding the nature of these domains paves the way for further optimization of optoelectronic devices using CH 3 NH 3 PbI 3 perovskite material.

36 MATERIALS SCIENCE↗

Magnetic structures of FeTiO{sub 3}-Fe{sub 2}O{sub 3} solid solution thin films studied by soft X-ray magnetic circular dichroism and ab initio multiplet calculations

The solid solutions between ilmenite (FeTiO{sub 3}) and hematite (α-Fe{sub 2}O{sub 3}) have recently attracted considerable attention as a spintronic material due to their interesting magnetic and electrical properties. In this study, the electronic and magnetic structures of epitaxially grown 0.6FeTiO{sub 3}·0.4Fe{sub 2}O{sub 3} solid solution thin films were investigated by combining x-ray absorption near-edge structure (XANES), x-ray magnetic circular dichroism (XMCD) for two different crystallographic projections, and first-principles theoretical calculations. The Fe L-edge XANES and XMCD spectra reveal that Fe is in the mixed-valent Fe{sup 2+}–Fe{sup 3+} states while Fe{sup 2+} ions are mainly responsible for the magnetization. Moreover, the experimental Fe L-edge XANES and XMCD spectra change depending on the incident x-ray directions, and the theoretical spectra explain such spectral features. We also find a large orbital magnetic moment, which can originate the magnetic anisotropy of this system. On the other hand, although the valence state of Ti was interpreted to be 4+ from the Ti L-edge XANES, XMCD signals indicate that some electrons are present in the Ti-3d orbital, which are coupled antiparallel to the magnetic moment of Fe{sup 2+} ions.

36 MATERIALS SCIENCE↗

The Study On The Physical Properties Of CdS Quantum Dots Synthesized By Ligand Exchange in Cd{sup 2+}-thiol Aqueous Solutions

We synthesized CdS quantum dots in aqueous medium using three thiolate-ligands, 2-mercaptoethanol (2ME), 3-mercaptopropanoic acid (MPA) and dimercaprol (BAL) by ligand exchange method. With a fixed concentration of thiols, the absorption edge of the quantum dots formed shifted towards shorter wavelength, as to the decreasing of a concentration of CdCl{sub 2}. When a concentration of CdCl{sub 2} and thiol was same, band gap energies and average sizes of the quantum dots were shown to be 2.65 eV, 3.26 nm for MPA, 2.84 eV, 3.16 nm for 2 ME and 3.16 eV, 1.81 nm for BAL, respectively. PL spectra analysis shows that as the decrease in molar concentration of CdCl{sub 2}, emission peak shifted towards shorter wavelength.

36 MATERIALS SCIENCE↗

Imaging graphite in air by scanning tunneling microscopy - Role of the tip

Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.

Colton, R. J.↗

Broad spectral response photodetector based on individual tin-doped CdS nanowire

High purity and tin-doped 1D CdS micro/nano-structures were synthesized by a convenient thermal evaporation method. SEM, EDS, XRD and TEM were used to examine the morphology, composition, phase structure and crystallinity of as-prepared samples. Raman spectrum was used to confirm tin doped into CdS effectively. The effect of impurity on the photoresponse properties of photodetectors made from these as-prepared pure and tin-doped CdS micro/nano-structures under excitation of light with different wavelength was investigated. Various photoconductive parameters such as responsivity, external quantum efficiency, response time and stability were analyzed to evaluate the advantage of doped nanowires and the feasibility for photodetector application. Comparison with pure CdS nanobelt, the tin-doped CdS nanowires response to broader spectral range while keep the excellect photoconductive parameters. Both trapped state induced by tin impurity and optical whispering gallery mode microcavity effect in the doped CdS nanowires contribute to the broader spectral response. The micro-photoluminescence was used to confirm the whispering gallery mode effect and deep trapped state in the doped CdS nanowires.

36 MATERIALS SCIENCE↗

DFT Studies of the Structure And Vibrational Spectra of Isolated Molybdena Species Supported on Silica

Different cluster models of isolated MO{sup VI} molybdate species anchored on silica surface were investigated using density functional theory (DFT). Isolated molybdate centers were modeled as either a penta-coordinated mono-oxo species or a tetra-coordinated di-oxo species. Standard free energy changes for interconversion between mono-oxo and di-oxo species indicate that these two species can coexist in equilibrium on the surface of amorphous silica with di-oxo species being the favored species at high temperature and low partial pressures of water. Comparison of Raman-spectra from experiment and DFT suggests that di-oxo species might be the prominent species responsible for the peak at 988 cm{sup -1}. This conclusion is strongly supported by the similarity in the EXAFS spectra obtained from experiment and theory. The thermodynamics for H2 reduction of isolated molybdate species were determined and found to be in reasonable agreement with experimental observation. DFT calculations of the structure and properties of the reduced MO{sup IV} centers and comparison of these with experimental results suggest that the reduced centers are present as mono-oxo species.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark matter directional detection in non-relativistic effective theories

We extend the formalism of dark matter directional detection to arbitrary one-body dark matter-nucleon interactions. The new theoretical framework generalizes the one currently used, which is based on 2 types of dark matter-nucleon interaction only. It includes 14 dark matter-nucleon interaction operators, 8 isotope-dependent nuclear response functions, and the Radon transform of the first 2 moments of the dark matter velocity distribution. We calculate the recoil energy spectra at dark matter directional detectors made of CF{sub 4}, CS{sub 2} and {sup 3}He for the 14 dark matter-nucleon interactions, using nuclear response functions recently obtained through numerical nuclear structure calculations. We highlight the new features of the proposed theoretical framework, and present our results for a spherical dark matter halo and for a stream of dark matter particles. This study lays the foundations for model independent analyses of dark matter directional detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling L 2,3 -edge X-ray absorption spectroscopy with linear response exact two-component relativistic time-dependent density functional theory

X-ray absorption spectroscopy (XAS) is a powerful tool that can provide physical insights into element-specific chemical processes and reactivities. Although relativistic time-dependent density functional theory (TDDFT) has been previously applied to model the L-edge region in XAS, there has not been a more comprehensive study of the choices of basis sets and density functional kernels available for variational relativistic excited state methods. In this work, we introduce the implementation of the generalized preconditioned locally harmonic residual algorithm to solve the complex-valued relativistic TDDFT for modeling the L-edge X-ray absorption spectra. Further, we investigate the L 2,3 -edge spectra of a series of molecular complexes using relativistic linear response TDDFT with a hybrid iterative diagonalization algorithm. A systematic error analysis was carried out with a focus on the energetics, intensities, and magnitude of L 2 –L 3 splitting compared to experiments. Additionally, the results from relativistic TDDFT calculations are compared to those computed using other theoretical methods, and the multideterminantal effects on the L-edge XAS were investigated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Spectra of Gamma-Irradiated LiF Crystals with Anisotropic Lithium Nanoparticles

The optical response of Li anisotropic defects and nanoparticles from three faces of cubic LiF crystals with 10-mm edges to γ radiation from a {sup 60}Со source with doses of 10{sup 5}–10{sup 9} R at 320 K in air is studied. After a maximum dose of 10{sup 9} R, scanning electron microscopy revealed submicron metal lithium flakes ordered into long parallel nanofilaments. The resonance absorption band, which shifts from 272 to 295 nm with increasing dose, is assigned to lithium nanocolloids in the (110) plane. The band at 202–225 nm observed only from the (100) face narrows at doses below 10{sup 5} R and is assigned to diatomic fluorine molecules in interstitial sites. The appearance of the 209–212–215-nm triplets at 2.7 × 10{sup 5} R from the (100) plane and the 211–213–215-nm triplets at 0.9 × 10{sup 5} R from the (010) plane is related to radiation-induced axially symmetric bipolarons with a high oscillator strength. The splitting of the 445-nm band into a 438–445–450-nm triplet is observed only for the (010) plane after a dose of 10{sup 6} R and is related to surface plasmon polaritons (longitudinal and transverse) of elongated Li nanoparticles. The (F{sub 2}–F{sub 3}) complexes are oriented in the most imperfect (111) plane and are seen along three cubic axes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗