Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

Rodriguez, Branelle R.↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

Rodriquez, Branelle R.↗

Flight Testing of the Forward Osmosis Bag for Water Recovery on STS-135

The Forward Osmosis Bag (FOB) is a personal water purification device for recovery of potable liquid from almost any non-potable water source. The FOB experiment was flown as a sortie mission on STS-135/ULF7 using flight-certified materials and a design based on the X-Pack(TradeMark) from Hydration Technology Innovations (Albany, OR). The primary objective was to validate the technology for use under microgravity conditions. The FOB utilizes a difference in solute concentration across a selectively permeable membrane to draw water molecules from the non-potable water while rejecting most chemical and all microbial contaminants contained within. Six FOB devices were tested on STS-135 for their ability to produce a potable liquid permeate from a feed solution containing 500 mL potassium chloride (15 g/L) amended with 0.1% methyl blue dye (w:v) tracer against an osmotic gradient created by addition of 60 mL of concentrate containing the osmolytes fructose and glucose, and 0.01% sodium fluorescein (w:v) tracer. Three FOB devices were physically mixed by hand for 2 minutes by a crewmember after loading to augment membrane wetting for comparison with three unmixed FOB devices. Hydraulic flux rate and rejection of salt and dye in microgravity were determined from a 60-mL sample collected by the crew on orbit after 6 hours. Post-flight analysis of samples collected on orbit demonstrated that the Forward Osmosis Bag achieved expected design specifications in microgravity. The hydraulic flux rate of water across the membrane was reduced approximately 50% in microgravity relative to ground controls that generated an average of 50 mL per hour using the same water and osmolyte solutions. The membrane rejected both potassium and chloride at >92% and methyl blue dye at >99.9%. Physical mixing of the FOB during water recovery did not have any significant effect on either flux rate or rejection of solutes from the water solution. The absence of buoyancy-driven convection in microgravity suggests that mass transport was dominated by diffusion, slowing the rate of permeate production across the membrane. It is possible that a predicted reduction in concentration polarization at the membrane surface that may have acted to increase the rate of permeate production in microgravity was negligible under the described test conditions.

Roberts, Michael S.↗

Model-based prognostics for batteries which estimates useful life and uses a probability density function

This invention develops a mathematical model to describe battery behavior during individual discharge cycles as well as over its cycle life. The basis for the form of the model has been linked to the internal processes of the battery and validated using experimental data. Effects of temperature and load current have also been incorporated into the model. Subsequently, the model has been used in a Particle Filtering framework to make predictions of remaining useful life for individual discharge cycles as well as for cycle life. The prediction performance was found to be satisfactory as measured by performance metrics customized for prognostics for a sample case. The work presented here provides initial steps towards a comprehensive health management solution for energy storage devices.

Saha, Bhaskar↗

Dating Igneous Rocks Using the Potassium–Argon Laser Experiment (KArLE) Instrument: A Case Study for ~380 Ma Basaltic Rocks

We report new K–Ar isochron data for two ~380 Ma basaltic rocks, using an updated version of the Potassium–Argon Laser Experiment (KArLE), which is being developed for future in situ dating of planetary materials. These basalts have K contents comparable with those of lunar KREEP basalts or igneous lithologies found by Mars rovers, whereas previous proof‐of‐concept studies focused primarily on more K‐rich rocks. We aim to measure these analogous samples to show the advancing capability of in situ K–Ar geochronology. Combining laser‐induced breakdown spectroscopy (LIBS), mass spectrometry (MS), and microscopic analyses, we measured the abundance of K and 40Ar from 23 spots on the basalt samples. We then constructed K–Ar isochron plots from these rocks. The breadboard instrument consists of flight‐equivalent devices including a 30‐mJ Nd:YAG laser and a quadrupole mass spectrometer. Despite much lower K abundances than in previous studies, the isochron slopes yielded 380 ± 44 Ma and 398 ± 50 Ma for 380.7‐Ma and 373.5‐Ma rocks, respectively, indicating that accuracy better than 25 Ma (<7%) is achievable with our instrument. The isochron intercepts both yielded trapped 40Ar approximately 1 × 10−6 cm3 STP/g. Our experimental results demonstrate that accurate and precise measurements are possible using the KArLE approach on basaltic rocks, which are ubiquitous on planetary surfaces, and are useful in addressing a wide range of questions in planetary science.

Yuichiro Cho↗

Volatile Organic Compounds Emitted from Air Fresheners: Plug-Ins at Home and Little Trees in Cars

Air fresheners contain volatile organic compounds (VOCs), some of which are possible hazardous air pollutants, carcinogens, or chemicals associated with adverse health effects such as asthma. This screening study identifies VOCs emitted from two types of air fresheners. Plug-in air fresheners are household products that release scents from a heated liquid. Little Tree air fresheners are commonly used solid devices designed to hang in from the rear view mirror in cars. VOCs that were released from heated samples of air fresheners were identified by gas chromatography mass spectroscopy (GCMS). Amongst VOCs commonly known to have scent properties, this screening also revealed the presence of compounds that are not associated with fragrances and that may have adverse health effects. In a pilot study to characterize how air fresheners affect air quality in real settings, air samples were collected on solid-phase microextraction (SPME) field samplers in a home setting and inside a vehicle, before and during air-freshener use. This pilot demonstrated some limited potential for SPME field samplers to track changes in VOC levels in real-life settings.

Adriana Pino-Delgado↗

In-Situ XRD/XRF to Support Life Detection on Mars

X-ray diffraction / X-ray fluorescence (XRD/XRF) analysis provides the most comprehensive mineralogical / compositional characterization of rocks and soils of any flight-capable technique. XRD data provide quantitative mineralogy (including abundance of X-ray amorphous materials) and crystal chemistry (structure, elemental composition and valence state), and XRF data provide complimentary major, minor, and some trace element abundances. Both types of data are important in evaluating habitability (environment of formation) and biosignature preservation/degradation (post-depositional diagenetic change). Whether or not a relict biosignature is detected, the mineral assemblage and its geochemistry can be used to determine the habitability of an ancient environment (e.g., salinity, pH, temperature), and to identify potential sources of energy for life (e.g., elements in different redox states). In this respect, a null result (a habitable environment lacking evidence of life) can play an important role in constraining the parameters of the search. Conversely, diagenetic alteration (taphonomic change) resulting from post-depositional variations in temperature, pressure or fluid chemistry can preserve evidence of biogenicity, erase such evidence completely or indeed can provide for post-depositional habitable conditions in the subsurface. XRD / XRF data are critical to these determinations. The CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover is the first XRD instrument flown in space. CheMin operates in transmission geometry with a Co X-ray source to minimize fluorescence from iron. Diffracted photons are collected with an energy-sensitive charge-coupled device (CCD). The position of the diffracted photons provides structural information for minerals, whereas the energy of sample-generated X-ray fluorescence photons provides elemental information, though these XRF data are qualitative. Mineralogical data from the CheMin XRD identified the three circumstances above: habitable depositional environments (e.g., Yellowknife Bay), habitable subsurface/diagenetic environments (e.g., throughout the Murray formation), and diagenetic conditions that may destroy evidence of habitability (e.g., oxidative and acidic environments at Vera Rubin ridge). Technological advances in X-ray technology and lessons learned from the operation of CheMin on Mars have resulted in a next-generation XRD/XRF, called CheMinX. Replacement of CheMin’s CCD with an array of hybrid pixel detectors and improvements in focusing optics dramatically decrease analysis time (15 minutes vs. 22 hours for MSL-CheMin) and result in a better angular resolution (0.18 vs. 0.30 °2θ for MSL-CheMin). This increased resolution improves mineral detection, including discrimination between types of pyroxenes, which is not possible with MSL-CheMin data. The hybrid pixel detectors do not require cooling like the MSL-CheMin CCD, therefore reducing the power needed to operate CheMinX. CheMinX has a silicon-drift detector (SDD) to measure fluoresced photons, enabling the quantification of major, minor, and some trace elements via XRF. XRD/XRF data are collected simultaneously in CheMinX, obviating the need for multiple compositional instruments. The CheMinX design also improves upon MSL-CheMin’s sample handling. Instead of sample cells on wheel, which are often not reusable and add complexity in commanding the instrument, CheMinX has single-use cells in a cartridge/dispenser configuration. Because of these improvements, CheMinX is an ideal instrument for Discovery-class life-detection missions, including Mars Life Explorer that was recommended for development in the Planetary Science and Astrobiology Decadal Survey 2023-2032.

E B Rampe↗

Advanced Measurement Devices for the Microgravity Electromagnetic Levitation Facility EML

This paper reports on two advanced measurement devices for the microgravity electromagnetic levitation facility (EML), which is currently under construction for the use onboard the "International Space Station (ISS)": the "Sample Coupling Electronics (SCE)" and the "Oxygen Sensing and Control Unit (OSC)". The SCE measures by a contactless, inductive method the electrical resistivity and the diameter of a spherical levitated metallic droplet by evaluating the voltage and electrical current applied to the levitation coil. The necessity of the OSC comes from the insight that properties like surface tension or, eventually, viscosity cannot seriously be determined by the oscillating drop method in the EML facility without knowing the conditions of the surrounding atmosphere. In the following both measurement devices are explained and laboratory test results are presented.

Brillo, Jurgen↗

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

GeoLab: A Geological Workstation for Future Missions

The GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance theThe GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance the early scientific returns from future missions and ensure that the best samples are selected for Earth return. The facility was also designed to foster the development of instrument technology. Since 2009, when GeoLab design and construction began, the GeoLab team [a group of scientists from the Astromaterials Acquisition and Curation Office within the Astromaterials Research and Exploration Science (ARES) Directorate at JSC] has progressively developed and reconfigured the GeoLab hardware and software interfaces and developed test objectives, which were to 1) determine requirements and strategies for sample handling and prioritization for geological operations on other planetary surfaces, 2) assess the scientific contribution of selective in-situ sample characterization for mission planning, operations, and sample prioritization, 3) evaluate analytical instruments and tools for providing efficient and meaningful data in advance of sample return and 4) identify science operations that leverage human presence with robotic tools. In the first year of tests (2010), GeoLab examined basic glovebox operations performed by one and two crewmembers and science operations performed by a remote science team. The 2010 tests also examined the efficacy of basic sample characterization [descriptions, microscopic imagery, X-ray fluorescence (XRF) analyses] and feedback to the science team. In year 2 (2011), the GeoLab team tested enhanced software and interfaces for the crew and science team (including Web-based and mobile device displays) and demonstrated laboratory configurability with a new diagnostic instrument (the Multispectral Microscopic Imager from the JPL and Arizona State University). In year 3 (2012), the GeoLab team installed and tested a robotic sample manipulator and evaluated robotic-human interfaces for science operations.

Evans, Cynthia↗

Miniature Low-Mass Drill Actuated by Flextensional Piezo Stack

Recent experiments with a flextensional piezoelectric actuator have led to the development of a sampler with a bit that is designed to produce and capture a full set of sample forms including volatiles, powdered cuttings, and core fragments. The flextensional piezoelectric actuator is a part of a series of devices used to amplify the generated strain from piezoelectric actuators. Other examples include stacks, bimorphs, benders, and cantilevers. These devices combine geometric and resonance amplifications to produce large stroke at high power density. The operation of this sampler/drill was demonstrated using a 3x2x1-cm actuator weighing 12 g using power of about 10-W and a preload of about 10 N. A limestone block was drilled to a depth of about 1 cm in five minutes to produce powdered cuttings. It is generally hard to collect volatiles from random surface profiles found in rocks and sediment, powdered cuttings, and core fragments. Toward the end of collecting volatiles, the actuator and the bit are covered with bellows-shaped shrouds to prevent fines and other debris from reaching the analyzer. A tube with a miniature bellows (to provide flexibility) is connected to the bit and directs the flow of the volatiles to the analyzer. Another modality was conceived where the hose is connected to the bellows wall directly to allow the capture of volatiles generated both inside and outside the bit. A wide variety of commercial bellows used in the vacuum and microwave industries can be used to design the volatiles capture mechanism. The piezoelectric drilling mechanism can potentially be operated in a broad temperature range from about-200 to less than 450 C. The actuators used here are similar to the actuators that are currently baselined to fly as part of the inlet funnel shaking mechanism design of MSL (Mars Science Laboratory). The space qualification of these parts gives this drill a higher potential for inclusion in a future mission, especially when considering its characteristics of low mass, small size, low power, and low axial loads for sampling.

Sherrit, Stewart↗

Development and testing of tip devices for horizontal axis wind turbines

A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. The objective was to improve performance by the reduction of tip losses. While power output can always be increased by a simple radial tip extension, such a modification also results in an increased gale load both because of the extra projected area and longer moment arm. Tip devices have the potential to increase power output without such a structural penalty. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbine. The types were a change in tip planform, and a single-element and double-element nonplanar tip extension (winglets). A complete data acquisition system was developed which recorded three wind speed components, ambient pressure, temperature, and turbine output. The system operated unattended and could perform real-time processing of the data, displaying the measured power curve as data accumulated in either a bin sort mode or polynomial curve fit. Approximately 270 hr of perormance data were collected over a three-month period. The sampling interval was 2.4 sec; thrus over 400,000 raw data points were logged. Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. Changes in orientation and angle-of-attack of the winglets were not made. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted.

Gyatt, G. W.↗

Holography and spacecraft attitude

Holographic device for satellite attitude determination, providing three axis reference information in analog or digital form from single star field sampling

Hallock, J. N.↗

Quantitative measurement of the "feel" of fabric

Device handle of fabric is a property related to flexibility, pliability, or compressibility. Technique requires extraction of flat circular sample of fabric through convergent nozzle.

Alley, V. L., Jr.↗

Optical Integrating Sphere for Vacuum Ultraviolet

Optical integrating sphere with integral sliding sample holder saves time by allowing radiometric measurements made on each of four samples without breaking vacuum. Designed to operate with interior evacuated so dye samples illuminated with short-wavelength ultraviolet strongly absorbed by air; need not be evacuated when using longer wavelengths. Device mounts on monochromator and evacuated through port that admits light from monochromator.

Butner, C. L.↗

Satellite laser ranging - Current status and future prospects

The characteristics and capabilities of instruments and operational techniques in the field of satellite laser ranging (SLR) are discussed. Following a brief introduction to the basic concept of SLR, a developmental history of each of the major components of an SLR hardware is given, including the laser transmitter, photomultiplier, discriminator, and time interval unit. The sources of range error in each of the devices are examined, and techniques for reducing error are described. A description of current SLR hardware is summarized using samples of actual satellite data obtained in 1981, which show that orbital fits with a 1.5 single shot rms and normal point rms error of less than 3 mm with 1-6 percent data entering. The development of even more precise measurement techniques in the future with the advent of the Starlette and LAGEOS II SLR system is also discussed.

Degnan, J. J.↗

Computerized in vitro test for chemical toxicity based on tetrahymena swimming patterns

An apparatus and method for rapidly determining chemical toxicity was evaluated. The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The device, called the Motility Assay Apparatus (MAA) is tested for 30 second determination of chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy, in addition to agreeing for all chemicals with previous manual evaluations of single cell motility.

Noever, David A.↗

1KW Power Transmission Using Wireless Acoustic-Electric Feed-Through (WAEF)

A variety of space applications require the delivery of power into sealed structures. Since the structural integrity can be degraded by holes for cabling we present an alternative method of delivering power and information using stress waves to the internal space of a sealed structure. One particular application of this technology is in sample return missions where it is critical to preserve the sample integrity and to prevent earth contamination. Therefore, the container has to be hermetically sealed and the integrity of the seal must be monitored in order to insure to a high degree of reliability the integrity of the sample return vessel. In this study we investigated the use of piezoelectric acoustic-electric power feed-through devices to transfer electric power wirelessly through a solid wall by using elastic or acoustic waves. The technology is applicable to a range of space and terrestrial applications where power is required by electronic equipment inside sealed containers, vacuum or pressure vessels, etc., where holes in the wall are prohibitive or may result in significant structural performance degradation or unnecessarily complex designs. To meet requirements of higher power applications, the feasibility to transfer kilowatts level power was investigated. Pre-stressed longitudinal piezoelectric feed-through devices were analyzed by finite element models and an equivalent circuit model was developed to predict the power transfer characteristics to different electric loads. Based on the results of the analysis a prototype device was designed, fabricated and a demonstration of the transmission of electric power up to 1.068-kW was successfully conducted. Efficiencies in the 80-90% range were also demonstrated and methods to increase the efficiency further are currently being considered.

pressure vessels↗