Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Space-qualified Chalcogenide Materials through ISS MISSE Exposure —From Property to Application

In March 2021, twenty-four samples of various phase change materials (PCMs - Ge2Sb2Te5, Ge2Sb2Se4Te1, and Sb2Se3) along with metasurface optical components comprised of these PCMs, were delivered to the International Space Station (ISS) as part of the Materials International Space Station Experiment (MISSE-14) test campaign [1]. Although PCMs have previously been noted for their resilience to various forms of radiation [2], they had not been tested in a realistic space environment until this exposure campaign with joint NASA and MIT collaboration. During the six-month total open exposure time in low earth orbit (LEO), high-resolution cameras scanned and captured photographs of the samples to detect changes as a function of time along with on-orbit measured temperature, UV radiation, total atomic oxygen fluence, and total ionizing radiation doses. The samples were returned to NASA Langley Research Center in March 2022 for post-flight characterization. This duplicated the preflight characterization (i.e., material composition and crystallinity that limits switching speed, index contrast, loss, etc.) conducted before launch. The space sector has witnessed tremendous growth within the past decade—not only from government agencies but also entrants from the private sector. Future growth in the capabilities of Earth observation, deep space, and planetary surface missions using miniaturized spacecraft platforms can only be sustained by innovations in the design of remote sensors and other sub-systems. Active metasurface optics with enhanced tunability and reconfigurability continues to redefine the boundaries of optical science [3]. The introduction of PCM technology and associated optical devices will help to accelerate the adoption of new architectures for reduced size, weight, power, and cost (SWaP-C) platforms in space.Here we introduce results obtained from the MISSE-14 mission related to space qualification of PCM-based optic devices and constituent materials. We then discuss our recent work developing active integrated photonic devices and metasurface optics based on PCMs for space applications. This includes tunable and reconfigurable optical metasurface devices to support NASA space communication and LIDAR applications. PCMs are quickly becoming interesting photonics materials but questions related to mission suitability remain, particularly in regard to key properties like figures-of-merit (FOM, Δn/Δk), glass forming temperatures, and phase transition speeds. This talk will describe efforts to afford researchers the ability to have access to cost-effective data on exposure-induced changes to PCM fundamental physical and optical properties to assess their utility for space applications. The MISSE-14 sample exposure campaign allows a complete understanding of the limitations of the PCMs for various space-based electronic and optoelectronic applications.

Chalcogenide Phase change material↗

Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts

This process is designed to estimate the thickness change of a material through data analysis of a digitized version of an x-ray (or a digital x-ray) containing the material (with the thickness in question) and various tooling. Using this process, it is possible to estimate a material's thickness change in a region of the material or part that is thinner than the rest of the reference thickness. However, that same principle process can be used to determine the thickness change of material using a thinner region to determine thickening, or it can be used to develop contour plots of an entire part. Proper tooling must be used. An x-ray film with an S-shaped characteristic curve or a digital x-ray device with a product resulting in like characteristics is necessary. If a film exists with linear characteristics, this type of film would be ideal; however, at the time of this reporting, no such film has been known. Machined components (with known fractional thicknesses) of a like material (similar density) to that of the material to be measured are necessary. The machined components should have machined through-holes. For ease of use and better accuracy, the throughholes should be a size larger than 0.125 in. (.3 mm). Standard components for this use are known as penetrameters or image quality indicators. Also needed is standard x-ray equipment, if film is used in place of digital equipment, or x-ray digitization equipment with proven conversion properties. Typical x-ray digitization equipment is commonly used in the medical industry, and creates digital images of x-rays in DICOM format. It is recommended to scan the image in a 16-bit format. However, 12-bit and 8-bit resolutions are acceptable. Finally, x-ray analysis software that allows accurate digital image density calculations, such as Image-J freeware, is needed. The actual procedure requires the test article to be placed on the raw x-ray, ensuring the region of interest is aligned for perpendicular x-ray exposure capture. One or multiple machined components of like material/ density with known thicknesses are placed atop the part (preferably in a region of nominal and non-varying thickness) such that exposure of the combined part and machined component lay-up is captured on the x-ray. Depending on the accuracy required, the machined component fs thickness must be carefully chosen. Similarly, depending on the accuracy required, the lay-up must be exposed such that the regions of the x-ray to be analyzed have a density range between 1 and 4.5. After the exposure, the image is digitized, and the digital image can then be analyzed using the image analysis software.

Grau, David↗

Failure Analysis of Heavy-Ion-Irradiated Schottky Diodes

In this paper, we use high- and low-magnification optical microscope images, thermal infrared camera images, and scanning electron microscope images to identify failure locations in heavy-ion-irradiated Schottky diodes. After failures have been identified, the parts were cross-sectioned to describe the structure of the failures and energy dispersive x-ray spectroscopy was used to characterize the materials in the failure structures.

Radiation effects↗

Beam Steering Devices Reduce Payload Weight

Scientists have long been able to shift the direction of a laser beam, steering it toward a target, but often the strength and focus of the light is altered. For precision applications, where the quality of the beam cannot be compromised, scientists have typically turned to mechanical steering methods, redirecting the source of the beam by swinging the entire laser apparatus toward the target. Just as the mechanical methods used for turning cars has evolved into simpler, lighter, power steering methods, so has the means by which researchers can direct lasers. Some of the typical contraptions used to redirect lasers are large and bulky, relying on steering gimbals pivoted, rotating supports to shift the device toward its intended target. These devices, some as large and awkward as a piece of heavy luggage, are subject to the same issues confronted by mechanical parts: Components rub, wear out, and get stuck. The poor reliability and bulk not to mention the power requirements to run one of the machines have made mechanical beam steering components less than ideal for use in applications where weight, bulk, and maneuverability are prime concerns, such as on an unmanned aerial vehicle (UAV) or a microscope. The solution to developing reliable, lighter weight, nonmechanical steering methods to replace the hefty steering boxes was to think outside the box, and a NASA research partner did just that by developing a new beam steering method that bends and redirects the beam, as opposed to shifting the entire apparatus. The benefits include lower power requirements, a smaller footprint, reduced weight, and better control and flexibility in steering capabilities. Such benefits are realized without sacrificing aperture size, efficiency, or scanning range, and can be applied to myriad uses: propulsion systems, structures, radiation protection systems, and landing systems.

Source record↗

Carbon Nanotube Based Nano-Electro-Mechanical Systems (NEMS)

Carbon nanotubes (CNT) enable nanoelectromechanical systems (NEMS) because of their inherent nanostructure, intrinsic electric conductivity and mechanical resilience. The collaborative work between Stanford (experiment) and NASA Ames (theory and simulation) has made progress in two types of CNT based NEMS for nanoelectronics and sensor applications. The CNT tipped scanning probe microscopy (SPM) is a NEMS in which CNT tips are used for nanoscale probing, imaging and manipulating. It showed great improvement in probing surfaces and biological systems over conventional tips. We have recently applied it to write (lithography) and read (image) uniform SiO2 lines on large Si surface area at speed up to 0.5 mm per s. Preliminary work using approximately 10 nm multiwall nanotube tips produced approximately 10 nm structures and showed that the CNT tips didn't wear down when crashed as conventional tips often do. This presents a solution to the long standing tip-wear problem in SPM nanolithography. We have also explored potential of CNT tips in imaging DNA in water. Preliminary experiment using 10 nm CNT tips reached 5 nm resolution. The 1 nm nanolithography and 1 nm DNA imaging can be expected by using approximately 1 nm CNT tips. In contrast to CNT tipped SPM, we also fabricated CNT devices on silicon wafer in which CNTs connect patterned metallic lines on SiO2/Si by a simple chemical vapor deposition process. Using conventional lithography for silicon wafer, we have been able to obtain CNT based transistors and sensors. Investigations of the CNT NEMS as physical, biological and chemical sensors are in progress and will be discussed.

Han, Jie↗

Calibration of a tunable excimer laser using the optogalvanic effect

A device for the calibration of a tunable excimer laser is currently under development. The laser provides UV radiation at three principal wavelengths, 193, 248, and 308 nm and is tunable over a range of 1 nm at each of these wavelengths. The laser is used as a non-intrusive optical probe to excite electronic transitions, and thereby induce fluorescence, of the principle molecules or atoms of interest in supersonic flowfields, both reacting and nonreacting. The fluorescence resulting from the excitation is observed with an intensified camera. Over the range of tunability at the three wavelengths are a number of transitions that can be observed. The intensity of the fluorescence depends in part on the local temperature and density. The nature of this thermodynamic dependence is variable among transitions; thus, identification of the transition under observation is required. The specific transition excited corresponds directly to the wavelength of the radiation. The present technique used for transition identification consists of scanning the laser across the range of tunability and observing the fluorescence resulting from various molecular transitions.

Abbitt, John D.↗

Automating analog design: Taming the shrew

The pace of progress in the design of integrated circuits continues to amaze observers inside and outside of the industry. Three decades ago, a 50 transistor chip was a technological wonder. Fifteen year later, a 5000 transistor device would 'wow' the crowds. Today, 50,000 transistor chips will earn a 'not too bad' assessment, but it takes 500,000 to really leave an impression. In 1975 a typical ASIC device had 1000 transistors, took one year to first samples (and two years to production) and sold for about 5 cents per transistor. Today's 50,000 transistor gate array takes about 4 months from spec to silicon, works the first time, and sells for about 0.02 cents per transistor. Fifteen years ago, the single most laborious and error prone step in IC design was the physical layout. Today, most IC's never see the hand of a layout designer: and automatic place and route tool converts the engineer's computer captured schematic to a complete physical design using a gate array or a library of standard cells also created by software rather than by designers. CAD has also been a generous benefactor to the digital design process. The architect of today's digital systems creates the design using an RTL or other high level simulator. Then the designer pushes a button to invoke the logic synthesizer-optimizer tool. A fault analyzer checks the result for testability and suggests where scan based cells will improve test coverage. One obstinate holdout amidst this parade of progress is the automation of analog design and its reduction to semi-custom techniques. This paper investigates the application of CAD techniques to analog design.

Barlow, A.↗

Chemical Characterization and Reactivity Testing of Fuel-Oxidizer Reaction Product (Test Report)

The product of incomplete reaction of monomethylhydrazine (MMH) and nitrogen tetroxide (NTO) propellants, or fuel-oxidizer reaction product (FORP), has been hypothesized as a contributory cause of an anomaly which occurred in the chamber pressure (PC) transducer tube on the Reaction Control Subsystem (RCS) aft thruster 467 on flight STS-51. A small hole was found in the titanium-alloy PC tube at the first bend below the pressure transducer. It was surmised that the hole may have been caused by heat and pressure resulting from ignition of FORP. The NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) was requested to define the chemical characteristics of FORP, characterize its reactivity, and simulate the events in a controlled environment which may have lead to the Pc-tube failure. Samples of FORP were obtained from the gas-phase reaction of MMH with NTO under laboratory conditions, the pulsed firings of RCS thrusters with modified PC tubes using varied oxidizer or fuel lead times, and the nominal RCS thruster firings at WSTF and Kaiser-Marquardt. Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), accelerating rate calorimetry (ARC), ion chromatography (IC), inductively coupled plasma (ICP) spectrometry, thermogravimetric analysis (TGA) coupled to FTIR (TGA/FTIR), and mechanical impact testing were used to qualitatively and quantitatively characterize the chemical, thermal, and ignition properties of FORP. These studies showed that the composition of FORP is variable but falls within a limited range of compositions that depends on the fuel loxidizer ratio at the time of formation, composition of the post-formation atmosphere (reducing or oxidizing), and reaction or postreaction temperature. A typical composition contains methylhydrazinium nitrate (MMHN), ammonium nitrate (AN), methylammonium nitrate (MAN), and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. The thermal decomposition reactions of FORP compositions used in this study were unremarkable, Neither the various compositions of FORP, the pure major components of FORP, nor mixtures of FORP with propellant-system corrosion products showed any unusual thermal activity when decomposed under laboratory conditions. Off-limit thruster operations were simulated by rapid mixing of liquid MMH and liquid NTO in a confined space. The test hardware was constructed with pressure- and temperature-measurement devices to determine if the expected fuel oxidizer reaction would result in increased energy release when FORP, FORP constituents, or propellant-system corrosion products were present. These tests demonstrated that FORP, MMHN, AN, or Inconel corrosion products can induce a mixture of MMH and NTO to produce component-damaging energies. The simulation-test program was not extensive enough to provide statistical probabilities for these events but did show that such events can occur. Damaging events required FORP or metal salts to be present at the initial mixing of MMH and NTO. Based on the results of these studies, it is suggested that removal or mitigation of a buildup of these materials may decrease the incidence of these high-energy, potentially damaging events.

Source record↗

Orientation Effects in ZnO Films Using Off-Axis Sputtering Deposition

ZnO is a wide-band-gap oxide material and has been used in numerous applications. It is also a good substrate for fabricating GaN-based (a blue laser candidate) devices. Off-axis sputtering technique is one of the best techniques in synthesizing oxide materials because negative ion bombardment and particle kinetic energy is greatly reduced when adatoms condense on substrates. Since the sputtered material from the target arrive on the substrate surface at a 90 deg. configuration, which differs from the normal sputtering geometry, it is expected that the film uniformity and composition distributions will be affected. However, the details of these properties and mechanisms have not been well studied. ZnO films are synthesized on (0001) sapphire and quartz substrates by off-axis sputtering deposition in various oxygen/argon mixture ratios and pressures at different temperatures. Substrates and sputtering sources are placed at three different orientations that are orthogonal to each other. The normal direction of a substrate is parallel to the gravity vector and the other is perpendicular to it. Film thickness profiles at different growth orientations are determined using a profimeter. All films grown at high temperatures have highly textured structures on quartz substrates and epitaxially grow on sapphire substrates. Because of this process, the film surface is very smooth. X-ray diffraction, scanning probe microscopy, and Fourier transfer infrared spectroscopy, and electrical measurements will be used to characterize these films. Detailed results will be discussed in the presentation.

Zhu, Shen↗

Carbon Nanotubes Growth by CVD on Graphite Fibers

Due to the superior electrical and mechanical properties of carbon nanotubes (CNT), synthesizing CNT on various substances for electronics devices and reinforced composites have been engaged in many efforts for applications. This presentation will illustrate CNT synthesized on graphite fibers by thermal CVD. On the fiber surface, iron nanoparticles as catalysts for CNT growth are coated. The growth temperature ranges from 600 to 1000 C and the pressure ranges from 100 Torr to one atmosphere. Methane and hydrogen gases with methane content of 10% to 100% are used for the CNT synthesis. At high growth temperatures (greater than or equal to 900 C), the rapid inter-diffusion of the transition metal iron on the graphite surface results in the rough fiber surface without any CNT grown on it. When the growth temperature is relative low (650-800 C), CNT with catalytic particles on the nanotube top ends are fabricated on the graphite surface. (Methane and hydrogen gases with methane content of 10% to 100% are used for the CNT synthesis.) (By measuring the samples) Using micro Raman spectroscopy in the breath mode region, single-walled or multi-walled CNT (MWCNT), depending on growth concentrations, are found. Morphology, length and diameter of these MWCNT are determined by scanning electron microscopy and Raman spectroscopy. The detailed results of syntheses and characterizations will be discussed in the presentation.

Zhu, Shen↗

Cross-Calibration of GNC and OLA LIDAR Systems Onboard OSIRIS-REx

The Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission carried two distinct light detection and ranging (LIDAR) systems: A scanning LIDAR called OSIRIS-REx Laser Altimeter (OLA) as part of the science payload, and a flash LIDAR system has part of the Guidance, Navigation, & Control (GNC) subsystem to serve as a navigation sensor during TAG. This presents a unique opportunity to compare the performance of the two LIDAR systems in close proximity to a small asteroid body. During the Orbital B mission phase, between June to August 2019, the OSIRIS-REx spacecraft orbited Bennu in a near-circular terminator orbit during which the altitude above the surface varied between 645 m to 740 m. Over five-week period observations were recorded with the OLA instrument that were subsequently used to construct a global digital terrain map (DTM) with a resolution of 5 cm and accuracy of ±20 cm. This model provides an excellent reference for assessing the performance of the GNC LIDAR system. Two different GNC LIDAR checkout activities were also conducted during the Orbital B phase: A limb-crossing check-out featured a series of slews to collect GNC LIDAR data across varying ranges and phase angles and operate the automatic gain control modes of the device; An OLA-GNC LIDAR cross calibration was designed to collect data from both the OLA and GNC LIDAR devices with overlapping footprints while the spacecraft was pointed nadir. This paper compares the on-orbit performance observed during the cross-calibration activity. The OLA-based global DTM and point clouds are used to evaluate the GNC LIDAR not available during previous analysis. The GNC LIDAR measurements were found to be well within accuracy and precision specified for the instrument, but much noisier than the measurements from OLA within this operating regime.

Jason M Leonard↗

Calibration and Characterization of the NASA EOS Terra and Aqua MODIS Instruments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is operating on both of the Terra and Aqua missions within the NASA Earth Observing System (EOS). The Terra MODIS instrument began taking observations in February 2000 and the Aqua MODIS instrument began taking observations in June of 2002 and both continue to operate successfully up to the present time. The MODIS instrument scans the entire Earth every 24 hours at nominal spatial resolutions between 250 and 1000 meters. It has 36 spectral bands spanning the electromagnetic spectrum from the visible wavelengths mar 400 micrometers to the emissive thermal infrared wavelengths at 15 micrometers. The MODIS instruments produce approximately 40 geophysical products devoted to observing land, ocean, and atmospheric processes and trends. To meet the scientific objectives associated with the NASA Earth sciences efforts the MODIS instruments must be and have been carefully calibrated and the performance characterized to meet specifications and goals such as five percent radiance and two percent relative to the sun accuracy in the twenty bands providing reflected solar radiation observations and one percent radiance accuracy in the sixteen bands observing in the thermal infrared. Over the time spanning instrument development and the pre-launch calibration and characterization of the instrument through the years of operation in space, the performance of the MODIS instruments have changed in multiple ways and appropriate adjustments made in relevant algorithms and look-up tables necessary to produce observations that meet the scientific objectives and requirements. The changes have been quantified and accounted for through careful use of on-board calibration devices such as the Spectro-Radiometric Calibration Assembly (SRCA), the Solar Diffuser (SD) and its companion Solar Diffuser Stability Monitor (SDSM), deep-space and lunar observations, and calibration targets on the Earth's surface. The strictest and most difficult challenges have come in trying to meet the requirements for observing Ocean color and related ocean biology processes over time and space. Overall the MODIS observations have been very successful in providing valuable scientific and applications results. The essential capabilities of MODIS are to be provided in the future by the Visible and Infrared Imaging Radiometer Suite (VIIRS) on the National Polar Orbiting Environmental Satellite Series (NPOESS).

Salomonson, Vincent V.↗

Abiotic Versus Biotic Weathering Of Olivine As Possible Biosignatures

We are investigating the weathering of silicate minerals by both purely inorganic, and biologically mediated processes using field-emission scanning electron microscopy (FESEM) and energy dispersive x-ray spectroscopy (EDS). By resolving surface textures and chemical compositions of weathered surfaces at the sub-micron scale we hope to be able to distinguish abiotic from biotic weathering processes and so establish a new biosignature applicable to the study of astromaterials including but not limited to the Martian meteorites. Sterilized olivine grains (San Carlos, Arizona) no more than 1-2 mm in their longest dimension were optically assayed to be uniform in color and free of inclusions were selected as weathering subjects. Prior to all experiments surface morphologies and Fe/Mg ratios were determined for each grain using FE-SEM and EDS. Experiments were divided into two categories abiotic and biotic and were compared with "naturally" weathered samples. For the preliminary experiments, two trials (open and closed to the ambient laboratory environment) were performed under abiotic conditions, and three trials under biotic conditions (control, day 1 and day 2). The open system abiotic trials used sterile grains heated at 98 C and 200 C for both 24 and 48 hours in 1L double distilled de-ionized water. The closed system abiotic trials were conducted under the same conditions but in a sealed two layer steel/Teflon "bomb" apparatus. The biotic trials used sterile grains mounted in a flow-through device attached to a wellhead on the Columbia River aquifer. Several discolored, altered, grains were selected to document "natural" weathering surface textures for comparison with the experimental samples. Preliminary results indicate there are qualitative differences in weathered surface textures among all the designed experiments. The olivine grains in abiotic trials displayed etching, pitting, denticulate margins, dissolution and clay formation. The scale of the features ranged from tens to a few microns with textures that remained relatively sharp and were crystallographically controlled. These results were comparable to that observed in the "naturally" weathered comparison/reference grains. Chemical analysis by EDS indicates these textures correlated with the relative loss of Mg and Fe cations by diffusional processes. In contrast the biotic results indicated changes in the etching patterns on the scale of hundreds of nm, which are neither sharp nor crystallographically controlled (nanoetching). Organisms, organic debris and/or extracellular polymeric substances (biofilm) were often in close proximity or direct contact with the nanoetching. While there are many poorly constrained variables in natural weathering experiments to contend with, such as the time scale, the chemistry of the fluids and degree of biologic participation, some preliminary observations can be made: (1) certain distinct surface textures appear correlated with the specific processes giving rise to these textures; (2) the process of diffusing cations can produce many similar styles of surface textural changes; and (3) the main difference between abiotic and biotically produced weathering is the scale (microns versus nanometers) and the style (crystallographically versus noncrystallographically controlled) of the textural features. Further investigation into nanosize scale surface textures should attempt to quantify both textures and chemical changes of the role of microorganisms in the weathering of silicates. Additional experiments addressing nanoscale textures of shock features for comparison with the current data set.

Longazo, Teresa G.↗

Monitoring Temperatures of Tires Using Luminescent Materials

A method of noncontact, optical monitoring of the surface temperature of a tire has been devised to enable the use of local temperature rise as an indication of potential or impending failures. The method involves the use of temperature-sensitive paint (or filler): Temperature-sensitive luminescent dye molecules or other luminescent particles are incorporated into a thin, flexible material coating the tire surface of interest. (Alternatively, in principle, the luminescent material could be incorporated directly into the tire rubber, though this approach has not yet been tested.) The coated surface is illuminated with shorter-wavelength light to excite longer-wavelength luminescence, which is observed by use of a charge-coupled-device camera or a photodetector (see Figure 1). If temporally constant illumination is used, then the temperature can be deduced from the known temperature dependence of the intensity response of the luminescence. If pulsed illumination is used, then the temperature can be deduced from the known temperature dependence of the time or frequency response of the luminescence. If sinusoidally varying illumination is used, then the temperature can be deduced from the known temperature dependence of the phase response of the luminescence. Unlike a prior method of monitoring the temperature at a fixed spot on a tire by use of a thermocouple, this method is not restricted to one spot and can, therefore, yield information on the spatial distribution of temperature: in particular, it enables the discovery of newly forming hot spots where damage may be starting. Also unlike in the thermocouple method, the measurements in this method are not vulnerable to breakage of wires in repeated flexing of the tire. Moreover, unlike in another method in which infrared radiation is monitored as an indication of surface temperature, the luminescence measurements in this method are not significantly affected by changes in infrared emissivity. This method has been demonstrated in application to the outside surface of a tire (see Figure 2), using both constant and pulsed light sources for illumination and cooled, slow-scan, gated CCD cameras for detection. For observing the temperature of the inside surface of a tire (this has not yet been done), it would probably be necessary to use fiber optics and/or windows for coupling excitation light into, and coupling luminescence out of, the interior volume.

Bencic, Timothy J↗

New Effective Material Couple--Oxide Ceramic and Carbon Nanotube-- Developed for Aerospace Microsystem and Micromachine Technologies

The prime driving force for using microsystem and micromachine technologies in transport vehicles, such as spacecraft, aircraft, and automobiles, is to reduce the weight, power consumption, and volume of components and systems to lower costs and increase affordability and reliability. However, a number of specific issues need to be addressed with respect to using microsystems and micromachines in aerospace applications--such as the lack of understanding of material characteristics; methods for producing and testing the materials in small batches; the limited proven durability and lifetime of current microcomponents, packaging, and interconnections; a cultural change with respect to system designs; and the use of embedded software, which will require new product assurance guidelines. In regards to material characteristics, there are significant adhesion, friction, and wear issues in using microdevices. Because these issues are directly related to surface phenomena, they cannot be scaled down linearly and they become increasingly important as the devices become smaller. When microsystems have contacting surfaces in relative motion, the adhesion and friction affect performance, energy consumption, wear damage, maintenance, lifetime and catastrophic failure, and reliability. Ceramics, for the most part, do not have inherently good friction and wear properties. For example, coefficients of friction in excess of 0.7 have been reported for ceramics and ceramic composite materials. Under Alternate Fuels Foundation Technologies funding, two-phase oxide ceramics developed for superior high-temperature wear resistance in NASA's High Operating Temperature Propulsion Components (HOTPC) project and new two-layered carbon nanotube (CNT) coatings (CNT topcoat/iron bondcoat/quartz substrate) developed in NASA's Revolutionary Aeropropulsion Concepts (RAC) project have been chosen as a materials couple for aerospace applications, including micromachines, in the nanotechnology lubrication task because of their potential for superior friction and wearf properties in air and in an ultrahigh vacuum, spacelike environment. At the NASA Glenn Research Center, two-phase oxide ceramic eutectics, Al2O3/ZrO2(Y2O3), were directionally solidified using the laser-float-zone process, and carbon nanotubes were synthesized within a high-temperature tube furnace at 800 C. Physical vapor deposition was used to coat all quartz substrates with 5-nm-thick iron as catalyst and bondcoat, which formed iron islands resembling droplets and serving as catalyst particles on the quartz. A series of scanning electron micrographs showing multiwalled carbon nanotubes directionally grown as aligned "nanograss" on quartz is presented. Unidirectional sliding friction eperiments were conducted at Glenn with the two-layered CNT coatings in contact with the two-phase Al2O3/ZrO2(Y2O3) eutectics in air and in ultrachigh vacuum. The main criteria for judging the performance of the materials couple for solid lubrication and antistick applications in a space environment were the coefficient of friction and the wear resistance (reciprocal of wear rate), which had to be less than 0.2 and greater than 10(exp 5) N(raised dot)/cubic millimetes, respectively, in ultrahigh vacuum. In air, the coefficient of friction for the CNT coatings in contact with Al2O3/ZrO2 (Y2O3) eutectics was 0.04, one-fourth of that for quartz. In an ultrahigh vacuum, the coefficient of friction for CNT coatings in contact with Al2O3/ZrO2 (Y2O3) was one-third of that for quartz. The two-phase Al2O3/ZrO2 (Y2O3) eutectic coupled with the two-layered CNT coating met the coefficient of friction and wear resistance criteria both in air and in an ultrahigh vacuum, spacelike environment. This material's couple can dramatically improve the stiction (or adhesion), friction, and wear resistance of the contacting surfaces, which are major issues for microdevices and micromachines.

Miyoshi, Kazuhisa↗

Radiation Dosimetry via Automated Fluorescence Microscopy

A developmental instrument for assessment of radiation-induced damage in human lymphocytes includes an automated fluorescence microscope equipped with a one or more chargecoupled- device (CCD) video camera(s) and circuitry to digitize the video output. The microscope is also equipped with a three-axis translation stage that includes a rotation stage, and a rotary tray that holds as many as thirty specimen slides. The figure depicts one version of the instrument. Once the slides have been prepared and loaded into the tray, the instrument can operate unattended. A computer controls the operation of the stage, tray, and microscope, and processes the digital fluorescence-image data to recognize and count chromosomes that have been broken, presumably by radiation. The design and method of operation of the instrument exploit fluorescence in situ hybridization (FISH) of metaphase chromosome spreads, which is a technique that has been found to be valuable for monitoring the radiation dose to circulating lymphocytes. In the specific FISH protocol used to prepare specimens for this instrument, metaphase lymphocyte cultures are chosen for high mitotic index and highly condensed chromosomes, then several of the largest chromosomes are labeled with three of four differently colored whole-chromosome-staining dyes. The three dyes, which are used both individually and in various combinations, are fluorescein isothiocyanate (FITC), Texas Red (or equivalent), and Cy5 (or equivalent); The fourth dye 4',6-diamidino- 2-phenylindole (DAPI) is used as a counterstain. Under control by the computer, the microscope is automatically focused on the cells and each slide is scanned while the computer analyzes the DAPI-fluorescence images to find the metaphases. Each metaphase field is recentered in the field of view and refocused. Then a four-color image (more precisely, a set of images of the same view in the fluorescent colors of the four dyes) is acquired. By use of pattern-recognition software developed specifically for this instrument, the images in the various colors are processed to recognize the metaphases and count the chromosome fragments of each color within the metaphases. The intermediate results are then further processed to estimate the proportion of cells that have suffered genetic damage. The prototype instrument scans at an average areal rate of 4.7 mm2/h in unattended operation, finding about 14 metaphases per hour. The false-alarm rate is typically less than 3 percent, and the metaphase-miss rate has been estimated to be less than 5 percent. The counts of chromosomes and fragments thereof are 50 to 70 percent accurate.

Castleman, Kenneth R.↗

XMOS XC-2 Development Board for Mechanical Control and Data Collection

The scanning microwave limb sounder (SMLS) will use technological improvements in low-noise mixers to provide precise data on the Earth s atmospheric composition with high spatial resolution. This project focuses on the design and implementation of a realtime control system needed for airborne engineering tests of the SMLS. The system must coordinate the actuation of optical components using four motors with encoder readback, while collecting synchronized telemetric data from a GPS receiver and 3-axis gyrometric system. A graphical user interface for testing the control system was also designed using Python. Although the system could have been implemented with an FPGA(fieldprogrammable gate array)-based setup, a processor development kit manufactured by XMOS was chosen. The XMOS architecture allows parallel execution of multiple tasks on separate threads, making it ideal for this application. It is easily programmed using XC (a subset of C). The necessary communication interfaces were implemented in software, including Ethernet, with significant cost and time reduction compared to an FPGA-based approach. A simple approach to control the chopper, calibration mirror, and gimbal for the airborne SMLS was needed. The XMOS board allows for multiple threads and real-time data acquisition. The XC-2 development kit is an attractive choice for synchronized, real-time, event-driven applications. The XMOS is based on the transputer microprocessor architecture developed for parallel computing, which is being revamped in this new platform. The XMOS device has multiple cores capable of running parallel applications on separate threads. The threads communicate with each other via user-defined channels capable of transmitting data within the device. XMOS provides a C-based development environment using XC, which eliminates the need for custom tool kits associated with FPGA programming. The XC-2 has four cores and necessary hardware for Ethernet I/O.

Jarnot, Robert F.↗

Quantification of In-flight Physical Changes: Anthropometry and Neutral Body Posture

Currently, NASA does not have sufficient in-flight anthropometric data gathered to assess the impact of physical body shape and size changes on suit sizing. For developing future planetary and reduced gravity suits, NASA needs to quantify the impacts of microgravity on anthropometry, body posture, and neutral body postures (NBP) to ensure optimal crew performance, fit, and comfort. To obtain these impacts, anthropometric data, circumference, length, height, breadth, and depth for body segments (i.e. chest, waist, bicep, thigh, calf) from astronauts for pre, in-, and postflight conditions needs to be collected. Once this data has been collected, a comparison between pre, in-, and postflight anthropometric values will be analyzed, yielding microgravity factors. The NBP will be used to determined body posture (joint angle) changes between subjects throughout the duration of a mission. Data collection, starting with Increments 37/38, is still in progress with the completion of 3 out of 12 subjects. NASA suit engineers and NASA's Extravehicular Activity (EVA) Project Office have identified that suit fit in microgravity could become an issue. It has been noted that crewmembers often need to adjust their suit sizing once they are in orbit. This adjustment could be due to microgravity effects on anthropometry and postural changes, and is necessary to ensure optimal crew performance, fit, and comfort in space. To date, the only data collected to determine the effects of microgravity on physical human changes have been during Skylab, STS-57, and a recent HRP study on seated height changes due to spinal elongation (Spinal Elongation, Master Task List [MTL] #221). The Skylab and the STS-57 studies found that there is a distinct neutral body posture (NBP) based on photographs. The still photographs showed that there is a distinguishable posture with the arms raised and the shoulder abducted; and, in addition, the knees were flexed with noticeable hip flexion and the foot plantar flexed [1,2]. This is the one standard set of body joint angles for a NBP in microgravity. A recent simulated microgravity NBP study [3] has shown an individual variability and inconsistencies in defining NBP. This variation may be influenced by spinal growth, the type of suit fit, and other potential anthropometry factors such as spinal curvature, age, and gender. The variation aspect of this essential data is required for all kinds of space device designs (e.g. suits, habitat, mobility aids, etc.). The method proposed considers the dynamic nature of body movement and will use a measurement technique to continually monitor posture and develop a probability likelihood of the natural posture and how the NBP postures are affected by anthropometry. Additionally, Skylab studies found that crewmembers experienced a stature growth of up to 3%. The data included 3 crewmembers that showed that there is a bi-phasic stature growth once the crew enters into weightlessness. However, the Spinal Elongation study identified that the crewmembers could experience about a 6% growth in seated height and a 3% stature growth, when exposed to microgravity. The results prove that not all anthropometric measurements have the same microgravity percent growth factor. For EVA and suit engineers to properly update the sizing protocol for microgravity, they need additional anthropometric data from space missions. Hence, this study is aimed to gather additional in-flight anthropometric measurements, such as length, depth, breadth, and circumference, to determine the changes to body shape and size due to microgravity effects. It is anticipated that by recording the potential changes to body shape and size, a better suit sizing protocol will be developed for ISS and other space missions. In essence, this study will help NASA quantify the impacts of microgravity on anthropometry to ensure optimal crew performance, fit, and comfort. This study will use simplistic data collection techniques, 3D laser scanning, digital still, and video data, and perform photogrammetric analyses to determine the changes that occur to the body shape, size, and NBP when exposed to a microgravity environment.

Young, K. S.↗