Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Modeling Partial Reflection Paths for Infrasound Analysis

Numerical methods enabling simulation of scattered and partially reflected infrasonic propagation paths produced by interaction with fine-scale structure in the middle atmosphere have been implemented in the infraGA ray tracing software. This capability enables simulation of ensonification in the classical stratospheric “shadow zone” that has been observed during the Humming Roadrunner and LSECE surface explosion campaigns as well as in other data sets. In the case of LSECE, a pair of stations roughly 140 kilometers east of the source location observed arrivals with celerities (horizontal group velocities) slightly slower than observed stratospheric paths at similar azimuths. The arrivals exhibited increasing trace velocity later in the wavetrain indicating a steepening of the arrival path for longer or slower propagation paths. Simulation of partially reflected paths using the updated infraGA software methods finds good agreement between observed and predicted infrasonic ensonification at these locations within the stratospheric shadow zone. Further development of the partial reflection physics and comparison with other data sets is needed to more robustly understand how such anomalous infrasonic signals can be predicted; however, the demonstration of this capability is a promising first step in such analyses.

97 MATHEMATICS AND COMPUTING↗

Materials for light-induced water splitting: In situ controlled surface preparation of GaPN epilayers grown lattice-matched on Si(100)

Energy storage is a key challenge in solar-driven renewable energy conversion. We promote a photochemical diode based on dilute nitride GaPN grown lattice-matched on Si(100), which could reach both high photovoltaic efficiencies and evolve hydrogen directly without external bias. Homoepitaxial GaP(100) surface preparation was shown to have a significant impact on the semiconductor-water interface formation. Here, we grow a thin, pseudomorphic GaP nucleation buffer on almost single-domain Si(100) prior to GaPN growth and compare the GaP{sub 0.98}N{sub 0.02}/Si(100) surface preparation to established P- and Ga-rich surfaces of GaP/Si(100). We apply reflection anisotropy spectroscopy to study the surface preparation of GaP{sub 0.98}N{sub 0.02} in situ in vapor phase epitaxy ambient and benchmark the signals to low energy electron diffraction, photoelectron spectroscopy, and x-ray diffraction. While the preparation of the Ga-rich surface is hardly influenced by the presence of the nitrogen precursor 1,1-dimethylhydrazine (UDMH), we find that stabilization with UDMH after growth hinders well-defined formation of the V-rich GaP{sub 0.98}N{sub 0.02}/Si(100) surface. Additional features in the reflection anisotropy spectra are suggested to be related to nitrogen incorporation in the GaP bulk.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pushing The Sample-Size Limit Of Infrared Vibrational Nano-Spectroscopy: From Monolayer Towards Single molecule sensitivity

While scattering-scanning near-field optical microscopy (s-SNOM) has demonstrated its potential to extend infrared (IR) spectroscopy into the nanometer scale, it has not yet reached its full potential in terms of spectroscopic sensitivity. We combine broadband femtosecond mid-IR excitation with an optimized spectral irradiance of 2 W/cm2/ cm–1 (power/area/bandwidth) and a combination of tip- and substrate enhancement to demonstrate single-monolayer sensitivity with exceptional signal-to-noise ratio. Using interferometric time domain detection, the near-field IR s-SNOM spectral phase directly reflects the molecular vibrational resonances and their intrinsic line shapes. We probe the stretching resonance of 1000 carbonyl groups at 1700 cm–1 in a self-assembled monolayer of 16-mercaptohexadecanoic acid (MHDA) on an evaporated gold substrate with spectroscopic contrast and sensitivity of 100 vibrational oscillators. From these results we provide a roadmap for achieving true single-molecule IR vibrational spectroscopy in s-SNOM by implementing optical antenna resonant enhancement, increased spectral pump power, and improved detection schemes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Syntheses, crystal structures, and NLO properties of the quaternary sulfides RE{sub 3}Sb{sub 0.33}SiS{sub 7} (RE=La, Pr)

Two quaternary sulfides RE{sub 3}Sb{sub 0.33}SiS{sub 7} (RE=La, Pr) have been prepared from stoichiometric mixtures of elements at 1223 K in an evacuated silica tube. They are the first examples of chalcogenides in the quaternary RE/Si/Sb/Q (RE=rare earth metal; Q=S, Se, Te) system. These two isostructural materials crystallize in the Ce{sub 3}Al{sub 1.67}S{sub 7} structure type in the hexagonal space group P6{sub 3}. Their structure features one-dimensional chains of face-sharing SbS{sub 6} octahedra running parallel to the c direction surrounded by the discrete SiS{sub 4} tetrahedra and RE cations. The La{sub 3}Sb{sub 0.33}SiS{sub 7} exhibits a SHG signal about 0.5 times that of the commercially used IR NLO material AgGaS{sub 2} at 2.05 μm laser. The optical gap of 1.92 eV for La{sub 3}Sb{sub 0.33}SiS{sub 7} was deduced from UV/Vis reflectance spectroscopy. - Graphical abstract: The RE{sub 3}Sb{sub 0.33}SiS{sub 7} (RE=La, Pr), crystalling in the Ce{sub 3}Al{sub 1.67}S{sub 7} structure type, have been prepared. The La{sub 3}Sb{sub 0.33}SiS{sub 7} exhibits a SHG signal about 0.5 times that of the IR NLO material AgGaS{sub 2}. - Highlights: • The RE{sub 3}Sb{sub 0.33}SiS{sub 7} (RE=La, Pr), crystalling in the Ce{sub 3}Al{sub 1.67}S{sub 7} structure type, have been prepared. • The La{sub 3}Sb{sub 0.33}SiS{sub 7} exhibits a SHG signal about 0.5 times that of the IR NLO material AgGaS{sub 2}. • The optical gap of 1.92 eV for La{sub 3}Sb{sub 0.33}SiS{sub 7} was deduced from UV/Vis reflectance spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hard X-ray mirrors for Nuclear Security

Research performed under this LDRD aimed to demonstrate the ability to detect and measure hard X-ray emissions using multilayer X-ray reflective optics above 400 keV, to enable the development of inexpensive and high-accuracy mirror substrates, and to investigate applications of hard X-ray mirrors of interest to the nuclear security community. Experiments conducted at the European Synchrotron Radiation Facility demonstrated hard X-ray mirror reflectivity up to 650 keV for the first time. Hard X-ray optics substrates must have surface roughness under 3 to 4 Angstrom rms, and three materials were evaluated as potential substrates: polycarbonates, thin Schott glass and a new type of flexible glass called Willow Glass®. Chemical smoothing and thermal heating of the surface of polycarbonate samples, which are inexpensive but have poor intrinsic surface characteristics, did not yield acceptable surface roughness. D263 Schott glass was used for the focusing optics of the NASA NuSTAR telescope. The required specialized hardware and process were costly and motivated experiments with a modified non-contact slumping technique. The surface roughness of the glass was preserved and the process yielded cylindrical shells with good net shape pointing to the potential advantage of this technique. Finally, measured surface roughness of 200 and 130 μm thick Willow Glass sheets was between 2 and 2.5 A rms. Additional results of flexibility tests and multilayer deposition campaigns indicated it is a promising substrate for hard X-ray optics. The detection of U and Pu characteristics X-ray lines and gamma emission lines in a high background environment was identified as an area for which X-ray mirrors could have an impact and where focusing optics could help reduce signal to noise ratio by focusing signal onto a smaller detector. Hence the first one twelvetant of a Wolter I focusing optics for the 90 to 140 keV energy range based on aperiodic multilayer coating was designed. Finally, we conducted the first demonstration that reflective multilayer mirrors could be used as diagnostic for HED experiment with an order of magnitude improvement in signal-to-noise ratio for the multilayer optic compared a transmission crystal spectrometer.

36 MATERIALS SCIENCE↗

Design and Construction of a Gamma Reaction History Diagnostic for the National Ignition Facility

Gas Cherenkov detectors have been used to convert fusion gammas into photons to record gamma reaction history measurements. These gas detectors include a converter, pressurized gas volume, relay collection optics, and a photon detector. A novel design for the National Ignition Facility (NIF) using 90° off-axis parabolic mirrors efficiently collects signal from fusion gammas with 8-ps time dispersion. Fusion gammas are converted to Compton electrons, which generate broadband Cherenkov light (response is from 250 to 700 nm) in a pressurized gas cell. This light is relayed into a high-speed detector using three parabolic mirrors. The relay optics collect light from a 125-mm-diameter by 600-mm-long interchangeable gas (CO2 or SF6) volume. The parabolic mirrors were electroformed instead of diamond turned to reduce scattering of the UV light. All mirrors are bare aluminum coated for maximum reflectivity. This design incorporates a 4.2-ns time delay that allows the detector to recover from prompt radiation before it records the gamma signal. At NIF, a cluster of four channels will allow for increased dynamic range, as well as different gamma energy thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarimetric Radar Characteristics of Simulated and Observed Intense Convective Cores for a Midlatitude Continental and Tropical Maritime Environment

This study contrasts midlatitude continental and tropical maritime deep convective cores using polarimetric radar observables and retrievals from selected deep convection episodes during the MC3E and TWPICE field campaigns. The continental convective cores produce stronger radar reflectivities throughout the profiles, while maritime convective cores produce more positive differential reflectivity Z dr and larger specific differential phase K dp above the melting level. Hydrometeor identification retrievals revealed the presence of large fractions of rimed ice particles (snow aggregates) in the continental (maritime) convective cores, consistent with the Z dr and K dp observations. The regional cloud-resolving model simulations with bulk and size-resolved bin microphysics are conducted for the selected cases, and the simulation outputs are converted into polarimetric radar signals and retrievals identical to the observational composites. Both the bulk and the bin microphysics reproduce realistic land and ocean (L-O) contrasts in reflectivity, polarimetric variables of rain drops, and hydrometeor profiles, but there are still large uncertainties in describing Z dr and K dp of ice crystals associated with the ice particle shapes/orientation assumptions. Sensitivity experiments are conducted by swapping background aerosols between the continental and maritime environments, revealing that background aerosols play a role in shaping the distinct L-O contrasts in radar reflectivity associated with raindrop sizes, in addition to the dominant role of background thermodynamics.

54 ENVIRONMENTAL SCIENCES↗

In Liquid Infrared Scattering Scanning Near-Field Optical Microscopy for Chemical and Biological Nanoimaging

Imaging biological systems with simultaneous intrinsic chemical specificity and nanometer spatial resolution in their typical native liquid environment has remained a long-standing challenge. In this paper we demonstrate a general approach of chemical nanoimaging in liquid based on infrared scattering scanning near-field optical microscopy (IR $s$-SNOM). It is enabled by combining AFM operation in a fluid cell with evanescent IR illumination via total internal reflection, which provides spatially confined excitation for minimized IR water absorption, reduced far-field background, and enhanced directional signal emission and sensitivity. We demonstrate in-liquid IR $s$-SNOM vibrational nanoimaging and conformational identification of catalase nano-crystals and spatio-spectral analysis of biomimetic peptoid sheets with monolayer sensitivity and chemical specificity at the few zeptomole level. This work establishes the principles of in-liquid and in-situ IR $s$-SNOM spectroscopic chemical nano-imaging and its general applicability to biomolecular, cellular, catalytic, electrochemical, or other interfaces and nano-systems in liquids or solutions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗

Detection of electric current pulses by a fibre-optic sensor using spun fibre

We have studied distinctive features of the response of a fibre-optic current sensor with a spun-fibre sensing loop to short current pulses. It has been shown theoretically that, in a reflective interferometer, the polarisation mode dispersion (PMD) in the sensing spun fibre has no effect on the pulsed output signal of the sensor, in contrast to the PMD in a connecting fibre line. The response of the current sensor to a rectangular pulse has linear edges and its duration is determined by the relationship between the current pulse duration and the light propagation time in the spun fibre. The transition from a linear edge to the maximum sensor response is not accompanied by any transient process. The maximum response amplitude corresponds to the response to an equivalent direct current at a current pulse duration exceeding the light propagation time in the spun fibre. The present calculation results and experimental data agree well for current pulses longer than 300 ns at a light propagation time in the spun fibre of ∼1 μs. (fibre-optic sensors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Are there echoes of gravitational waves?

In several approaches to evading the information paradox, the semiclassical black hole is replaced by an Exotic Compact Object (ECO). It has been conjectured that gravitational waves emitted by the merger of ECOs can reflect off the ECOs and produce a detectable ‘echo’. We argue that while a part of the wave can indeed reflect off the surface of an ECO, this reflected wave will get trapped by a new closed trapped surface produced by its own backreaction. Thus, no detectable signal of the echo will emerge to infinity. The only assumption in this analysis is that causality is maintained to leading order in gently curved spacetime. Thus, if echoes are actually detected, then we would face a profound change in our understanding of physics.

Astronomy & Astrophysics↗

Using Imaging Methods to Interrogate Radiation-Induced Cell Signaling

There is increasing emphasis on the use of systems biology approaches to define radiation induced responses in cells and tissues. Such approaches frequently rely on global screening using various high throughput 'omics' platforms. Although these methods are ideal for obtaining an unbiased overview of cellular responses, they often cannot reflect the inherent heterogeneity of the system or provide detailed spatial information. Additionally, performing such studies with multiple sampling time points can be prohibitively expensive. Imaging provides a complementary method with high spatial and temporal resolution capable of following the dynamics of signaling processes. In this review, we utilize specific examples to illustrate how imaging approaches have furthered our understanding of radiation induced cellular signaling. Particular emphasis is placed on protein co-localization, and oscillatory and transient signaling dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization of the imaging response of scanning microwave microscopy measurements

In this work, we present the analytical modeling and preliminary experimental results for the choice of the optimal frequencies when performing amplitude and phase measurements with a scanning microwave microscope. In particular, the analysis is related to the reflection mode operation of the instrument, i.e., the acquisition of the complex reflection coefficient data, usually referred as S{sub 11}. The studied configuration is composed of an atomic force microscope with a microwave matched nanometric cantilever probe tip, connected by a λ/2 coaxial cable resonator to a vector network analyzer. The set-up is provided by Keysight Technologies. As a peculiar result, the optimal frequencies, where the maximum sensitivity is achieved, are different for the amplitude and for the phase signals. The analysis is focused on measurements of dielectric samples, like semiconductor devices, textile pieces, and biological specimens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monitoring changes in human activity during the COVID-19 shutdown in Las Vegas using infrasound microbarometers

While studies of urban acoustics are typically restricted to the audio range, anthropogenic activity also generates infrasound (<20 Hz, roughly at the lower end of the range of human hearing). Shutdowns related to the COVID-19 pandemic unintentionally created ideal conditions for the study of urban infrasound and low frequency audio (20–500 Hz), as closures reduced human-generated ambient noise, while natural signals remained relatively unaffected. An array of infrasound sensors deployed in Las Vegas, NV, provides data for a case study in monitoring human activity during the pandemic through urban acoustics. The array records a sharp decline in acoustic power following the temporary shutdown of businesses deemed nonessential by the state of Nevada. This decline varies spatially across the array, with stations close to McCarran International Airport generally recording the greatest declines in acoustic power. Further, declines in acoustic power fluctuate with the time of day. As only signals associated with anthropogenic activity are expected to decline, this gives a rough indication of periodicities in urban acoustics throughout Las Vegas. This study's results reflect the city's response to the pandemic and suggest spatiotemporal trends in acoustics outside of shutdowns.

58 GEOSCIENCES↗

Experimental determination of axion signal power of dish antennas and dielectric haloscopes using the reciprocity approach

The reciprocity approach is a powerful method to determine the expected signal power of axion haloscopes in a model-independent way. Especially for open and broadband setups like the MADMAX dielectric haloscope the sensitivity to the axion field is difficult to calibrate since they do not allow discrete eigenmode analysis and are optically too large to fully simulate. The central idea of the reciprocity approach is to measure a reflection-induced test field in the setup instead of trying to simulate the axion-induced field. In this article, the reciprocity approach is used to determine the expected signal power of a dish antenna and a minimal dielectric haloscope directly from measurements. The results match expectations from simulation but also include important systematic effects that are too difficult to simulate. In particular, the effect of antenna standing waves and higher order mode perturbations can be quantified for the first time in a dielectric haloscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Signal of a Dynamic Glass Transition

Pentaphenyl trimethyl trisiloxane is an isotropic liquid at room temperature with a dynamic glass transition at 224 K. Using x-ray reflectivity, we see surface density oscillations (layers) develop below 285 K, similar to those seen in other metallic and dielectric liquids and in computer simulations. The layering threshold is {approx}0.23 times the liquid-gas critical temperature. Upon cooling further, there is a sharp increase at 224 K in the persistence of the surface layers into the bulk material, i.e., an apparently discontinuous change in static structure at the glass transition.

36 MATERIALS SCIENCE↗

WE-DE-207B-08: Towards Standardization of X-Ray Filters in Digital Mammography-Enabled Breast Tomosynthesis Systems

Purpose: In digital breast tomosynthesis (DBT) systems capable of digital mammography (DM), Al filters are used during DBT and K-edge filters during DM. The potential for standardizing the x-ray filters with Al, instead of K-edge filters, was investigated with intent to reduce exposure duration and to promote a simpler system design. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for K-edge filters (50µm Rh; 50µm Ag) were compared with Al filters of varying thickness. Two strategies for matching the HVT from K-edge and Al filtered spectra were investigated: varying the kVp for fixed Al thickness, or varying the Al thickness at matched kVp. For both strategies, Al filters were an order of magnitude thicker than K-edge filters. Hence, Monte Carlo simulations were conducted with the GEANT4 toolkit to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Al and K-edge filters. Results: Results show the potential for replacing currently used Kedge filters with Al. For fixed Al thickness (700µm), ±1 kVp and +(1–3) kVp change, matched HVT of Rh and Ag filtered spectra. At matched kVp, Al thickness range (650,750)µm and (750,860)µm matched the HVT from Rh and Ag filtered spectra. Photon fluence/mAs with Al filters were 1.5–2.5 times higher, depending on kVp and Al thickness, compared to K-edge filters. Although Al thickness was an order higher than K-edge filters, neither the SPR nor the scatter PSF differed from K-edge filters. Conclusion: The use of Al filters for digital mammography is potentially feasible. The increased fluence/mAs with Al could decrease exposure duration for the combined DBT+DM exam and simplify system design. Effect of x-ray spectrum change due to Al filtration on radiation dose, signal, noise, contrast and related metrics are being investigated. Funding support: Supported in part by NIH R21CA176470 and R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Inhibition of tissue factor signaling in breast tumour xenografts induces widespread changes in the microRNA expression profile

Highlights: • Clotting protein, tissue factor (TF) mediates intracellular signalling in cancer. • Selective inhibition of TF signalling exerts potent anticancer effect in mice. • Inhibition of TF signalling changes the tumour miR expression profile in vivo. • MiRs altered by blockade of TF signalling share common biological pathways. Tissue factor (TF) is a transmembrane receptor for coagulation factor VII/VIIa and is frequently overexpressed by cancer cells. The TF/VIIa complex acts as the main initiator of the clotting cascade in blood and a trigger of intracellular signaling that changes gene expression and the cellular phenotype. However, pathways mediating these changes are still poorly characterized and especially the impact of TF signals on regulatory microRNA (miR) networks in cancer remains unknown. We show that the monoclonal antibody that selectively neutralises the signaling (but not coagulant) function of human TF (CNTO 2559) inhibits progression of MDA-MB-231 breast cancer xenografts in mice and prolongs animal survival. CNTO 2559 blocks FVIIa-induced expression of interleukin 8 (IL-8) by cancer cells without impacting factor Xa (FXa) generation. Notably, acute exposure of MDA-MB-231 tumour xenografts to CNTO 2559 systemic injections triggers wide spread changes in the tumour miR profile including alterations in 75 miRs (55 downregulated) and impacting several miR-regulated and cancer-related pathways. These results suggest that TF signaling in the tumour microenvironment may provoke vast changes in the miR profile of cancer cells, affect disease biology, and reflect tumour interaction with the coagulation system, thereby presenting itself as a possible biomarker.

60 APPLIED LIFE SCIENCES↗