Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Self-cleaning and de-pollution efficacies of photocatalytic architectural membranes

Photocatalytic self-cleaning “cool” roofs and walls can maintain high albedos, saving building cooling energy, reducing peak power demand, and mitigating the urban heat island effect. Other environmental benefits result from their de-polluting properties. Specimens from two different photocatalytic architectural membranes and a non-photocatalytic control were exposed alongside vertically, facing west, for two years at three California sites, and retrieved quarterly for testing. Photocatalytic materials showed excellent self-cleaning performance, retaining albedos of 0.74 – 0.75. By contrast, the control material exhibited an albedo loss of up to 0.10, with appreciable soiling observed by scanning electron microscopy. De-pollution capacity was assessed by quantifying NO removal and NOx deposition rates at 60 °C. Furthermore, efficacy varied with exposure location, weather conditions, and the nature of the photocatalytic material. Seasonal effects were observed, with partial inhibition during the dry season and reactivation during the rainy season.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The causal relationship between melt pool geometry and energy absorption measured in real time during laser-based manufacturing

During laser powder bed fusion additive manufacturing, laser power absorption is governed by a pro -tean pool of molten metal that can present as a highly reflective surface, a deeply absorbing cavity, or some amalgamation thereof. These melt pool dynamics have been linked to defect creation, porosity, and surface finish quality. Although these are therefore critical for determining final part quality, their in-stantaneous influence on laser absorption have only been explored through simulation. To date, direct real-time observations have been elusive due to the locally extreme environment. In this work, we fo-cus a laser on Ti-6Al-4V powder and bare plate while quantifying the time-dependent, absolute energy absorption by monitoring omnidirectional backscattered laser intensity. We also simultaneously record the projective melt pool geometries with high-speed synchrotron x-ray imaging. We find that laser ab-sorption strongly reflects the stability of the vapor depression over a wide range of applied laser powers, oxygen content in the processing atmosphere, and with the presence of powder. During laser scanning of a powder bed surface, we find a significant absorption reduction after 400 mu s due to a dramatic change in the vapor depression aspect ratio-an event known to create porosity. Furthermore, as several industrial scan strate-gies necessitate thousands of these events during a build, their identification and control is of significant practical importance. Lastly, a normalized enthalpy model is demonstrated to be effective in quantifying the relationship between the laser absorption and cavity depth, even under transient conditions. In addi-tion to providing vital quantitative data for simulation calibration, the correlation of melt pool geometry with laser absorption during realistic processing conditions suggests the use of a total backscattered light detection system for real-time process control.

36 MATERIALS SCIENCE↗

Hardware-Control: Instrument control and automation package

Conducting experimental research often relies on the control of laboratory instruments to, for example, control power supplies, move stages, and measure data. Tasks, such as data logging or parameter scans, often need to be automated. Being able to easily create a user interface to the hardware and to be able to reuse code is highly desirable.

97 MATHEMATICS AND COMPUTING↗

Slipstream Testing of Amine-Based Solvents at a Low-Rank Coal-Fired Power Plant

Conference presentation for 38th Annual International Pittsburgh Coal Conference, Virtual, September 20–23, 2021. To better assess mitigation strategies for aerosol reduction to extend solvent life, the University of North Dakota Energy & Environmental Research Center (EERC) installed a pilot-scale CO 2 absorption system at a lignite-fired plant in central North Dakota. The pilot-scale system was operated using both commercial KS-1™ solvent and advanced KS-21™ solvent provided by Mitsubishi Heavy Industries (MHI). MHI’s proprietary amine emission reduction unit (AERU™) technology was installed downstream of the absorber columns to reduce solvent losses by recovering amines at the system outlet. Fine particulate loading was measured throughout the capture system with and without a WESP operating and using both solvents. Captured particulate was brought back to the EERC to be analyzed for chemical composition and to be examined by scanning electron microscopy for particulate structure. These variables were then correlated to performance of particulate control devices in reducing aerosol formation and solvent losses.

01 COAL, LIGNITE, AND PEAT↗

Nanostructured ZnO-Based Electrochemical Sensor with Anionic Surfactant for the Electroanalysis of Trimethoprim

In this research, detection of trimethoprim (TMP) was carried out using a nanostructured zinc oxide nanoparticle-modified carbon paste electrode (ZnO/CPE) with an anionic surfactant and sodium dodecyl sulphate (SDS) with the help of voltametric techniques. The electrochemical nature of TMP was studied in 0.2 M pH 3.0 phosphate-buffer solution (PBS). The developed electrode displayed the highest peak current compared to nascent CPE. Effects of variation in different parameters, such as pH, immersion time, scan rate, and concentration, were investigated. The electrode process of TMP was irreversible and diffusion controlled with two electrons transferred. The effective concentration range (8.0 × 10 -7 M–1.0 × 10 -5 M) of TMP was obtained by varying the concentration with a lower limit of detection obtained to be 2.58 × 10 -8 M. In addition, this approach was effectively employed in the detection of TMP in pharmaceutical dosages and samples of urine with the excellent recovery data, suggesting the potency of the developed electrode in clinical and pharmaceutical sample analysis.

36 MATERIALS SCIENCE↗

Deep sea mega-geomorphology: Progress and problems

Historically, marine geologists have always worked with mega-scale morphology. This is a consequence both of the scale of the ocean basins and of the low resolution of the observational remote sensing tools available until very recently. In fact, studies of deep sea morphology have suffered from a serious gap in observational scale. Traditional wide-beam echo sounding gave images on a scale of miles, while deep sea photography has been limited to scales of a few tens of meters. Recent development of modern narrow-beam echo sounding coupled with computer-controlled swath mapping systems, and development of high-resolution deep-towed side-scan sonar, are rapidly filling in the scale gap. These technologies also can resolve morphologic detail on a scale of a few meters or less. As has also been true in planetary imaging projects, the ability to observe phenomena over a range of scales has proved very effective in both defining processes and in placing them in proper context.

Bryan, W. B.↗

Transonic turbine blade cascade testing facility

NASA LeRC has designed and constructed a new state-of-the-art test facility. This facility, the Transonic Turbine Blade Cascade, is used to evaluate the aerodynamics and heat transfer characteristics of blade geometries for future turbine applications. The facility's capabilities make it unique: no other facility of its kind can combine the high degree of airflow turning, infinitely adjustable incidence angle, and high transonic flow rates. The facility air supply and exhaust pressures are controllable to 16.5 psia and 2 psia, respectively. The inlet air temperatures are at ambient conditions. The facility is equipped with a programmable logic controller with a capacity of 128 input/output channels. The data acquisition system is capable of scanning up to 1750 channels per sec. This paper discusses in detail the capabilities of the facility, overall facility design, instrumentation used in the facility, and the data acquisition system. Actual research data is not discussed.

Verhoff, Vincent G.↗

Stable isotope analysis using tunable diode laser spectroscopy

Ratios of C-12/C-13 in CO2 have been measured using a tunable diode laser (TDL) spectrometer to an accuracy of better than 0.4 percent. These results were made possible by the use of state-of-the-art high-temperature TDLs, an etalon and wavenumber calibration technique, high-speed assembly language controlled data acquisition, and the ratioing of absorbances from simultaneously acquired sample and reference data scans. The dual beam spectrometer that is employed uses the sweep integration technique in a spectral region where adjacent spectral lines are of approximately equal absorbance at the expected isotopic abundances.

Becker, Joseph F.↗

Transonic turbine blade cascade testing facility

NASA LeRC has designed and constructed a new state-of-the-art test facility. This facility, the Transonic Turbine Blade Cascade, is used to evaluate the aerodynamics and heat transfer characteristics of blade geometries for future turbine applications. The facility's capabilities make it unique: no other facility of its kind can combine the high degree of airflow turning, infinitely adjustable incidence angle, and high transonic flow rates. The facility air supply and exhaust pressures are controllable to 16.5 psia and 2 psia, respectively. The inlet air temperatures are at ambient conditions. The facility is equipped with a programmable logic controller with a capacity of 128 input/output channels. The data acquisition system is capable of scanning up to 1750 channels per sec. This paper discusses in detail the capabilities of the facility, overall facility design, instrumentation used in the facility, and the data acquisition system. Actual research data is not discussed.

Verhoff, Vincent G.↗

Shear-Wave Ultrasonic Inspection With A Dry Couplant

Automated ultrasonic inspection system includes dry couplant pad attached to ultrasonic transducer. Designed to be mounted on robot arm in automated manufacturing (robotic welding) work cell. Between, during, or after manufacturing operations, robot scans ultrasonic transducer along workpiece. Workpiece reworked in place, if necessary. In principle, computer program controlling inspection overlaid on program controlling welding operations.

Willenberg, James D↗

Low Magnitude Mechanical Signals Reduce Risk-Factors for Fracture during 90-Day Bed Rest

Long duration spaceflight leads to multiple deleterious changes to the musculoskeletal system, where loss of bone density, an order of magnitude more severe than that which follows the menopause, combined with increased instability, conspire to elevate the risk of bone fracture due to falls on return to gravitational fields. Here, a ground-based analog for spaceflight is used to evaluate the efficacy of a low-magnitude mechanical intervention, VIBE (Vibrational Inhibition of Bone Erosion), as a potential countermeasure to preserve musculoskeletal integrity in the face of disuse. Twenty-six subjects consented to ninety days of six-degree head-down tilt bed-rest. 18 completed the 90d protocol, 8 of which received daily 10-minute exposure to 30 Hz, 0.3g VIBE, applied in the supine position using a vest elastically coupled to the vibrating platform. The shoulder harness induced a load of 60% of the subjects body weight. At baseline and 90d, Qualitative Ultrasound Scans (QUS) of the calcaneus and CT-scans of the hip and spine were performed to measure changes in bone density. Postural control (PC) was assessed through center of pressure (COP) recordings while subjects stood on a force platform for 4 minutes of quiet stance with eyes closed, and again with eyes opened. As compared to control bedrest subjects,

Muir, J. W.↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗

Study of Fabry-Perot Etalon Stability and Tuning for Spectroscopic Rayleigh Scattering

The Fabry-Perot interferometer is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating flow properties such as gas velocity and temperature. Rayleigh scattered light from a focused laser beam can be directly imaged through a solid Fabry-Perot etalon onto a CCD detector to provide the spectral content of the scattered light. The spatial resolution of the measurements is governed by the locations of interference fringes. The location of the fringes can be changed by altering the etalon?s physical characteristics, such as thickness and index of refraction. For a fused silica solid etalon the physical properties can be adjusted by changing the etalon temperature; hence changing the order of the interference pattern and the physical fringe locations. Controlling the temperature of the etalon can provide for a slow time-response spatial scanning method for this type of etalon system. A custom designed liquid crystal Fabry-Perot (LCFP) can provide for a fast time-response method of scanning the etalon system. Voltage applied to the liquid crystal interface sets the etalon?s properties allowing Rayleigh measurements to be acquired at varying spatial locations across the image of the laser beam over a very short time period. A standard fused silica etalon and a tunable LCFP etalon are characterized to select the system that is best suited for Rayleigh scattering measurements in subsonic and supersonic flow regimes. A frequency-stabilized laser is used to investigate the apparent frequency stability and temperature sensitivity of the etalon systems. Frequency stability and temperature sensitivity data of the fused silica and LCFP etalon systems are presented in this paper, along with measurements of the LCFP etalon?s tuning capabilities. Rayleigh scattering velocity measurements with both etalon systems are presented, in an effort to determine which etalon is better suited to provide optical flow measurements of velocity, temperature, and density.

Clem, Michelle M.↗

Particulate impacts on the UHCRE cosmic ray experiment teflon covers: The ESA programme

The optical scanning equipment at the University of Kent Unit for Space Science consists of a 102.5 by 42.5 cm computer controlled motorized stage which has a reproduction accuracy of 30 microns over the entire area. This is used with an optical microscope connected to two charge coupled device video cameras which can be used to obtain stereo color images of any features found. A coordinate system can be defined on each cover by means of two or more reference marks which allow a feature to be located using different equipment such as a scanning electron microscope, providing two known marks can be found. By using back illumination, penetrating features can be found automatically, and their sizes, circularity, and positions logged for later revisiting either on the optical system or using a scanning electron microscope.

Mcdonnell, J. A. M.↗

Control of the Soft X-ray Polychromator on the Solar Maximum Mission Satellite

The Soft X-ray Polychromator on the Solar Maximum Mission Satellite consists of two largely independent instruments: the Flat Crystal Spectrometer, a highly collimated scanning spectrometer mounted on a raster platform, and the Bent Crystal Spectrometer, a broadly collimated spectrometer providing high time-resolution (128 ms) spectra for the study of rapidly evolving phenomena. Each instrument is controlled by a microcomputer system built around an RCA 1802 microprocessor. This paper presents a discussion of the motivation for using a microprocessor in this application, and the design concepts that were implemented. The effectiveness of the approach as seen after several months of operation will also be discussed.

Springer, L. A.↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

Sintering Mechanism of Pt/Al 2 O 3 in Complex Emission Gases Elucidated via In Situ Environmental STEM

Emission control catalysts are crucial for protecting human health by preventing the release of harmful gases and unburnt fuel into the atmosphere. These catalysts often face deactivation through sintering processes in high-temperature, chemically reactive environments containing multiple gas species. Here, we use in situ environmental scanning transmission electron microscopy to monitor the sintering behavior and transient morphologies of Pt/Al 2 O 3 in various relevant gas environments through controlled experiments. Our results reveal the particle migration and atomic ripening behavior of Pt/Al 2 O 3 at the atomic scale in the presence of water vapor and oxygen, which differs from behaviors observed in single gas environments. We identify an atomic ripening mechanism involving the dissociation and migration of Pt adatom chains from Pt nanoparticles, observed only in combinational gases. Finally, these findings provide valuable insights into catalyst degradation behavior in complex gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗