Search NASA⌕ Search

SEARCH · Search NASA

Results for “Small”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Evidence for small-molecule-mediated loop stabilization in the structure of the isolated Pin1 WW domain

Two structures of a small protein with a defined tertiary fold, the isolated Pin1 WW domain, have been determined via racemic crystallization with small-molecule additives. These additives, which are either racemic or achiral, appear to stabilize a dynamic loop region of the structure. The human Pin1 WW domain is a small autonomously folding protein that has been useful as a model system for biophysical studies of β-sheet folding. This domain has resisted previous attempts at crystallization for X-ray diffraction studies, perhaps because of intrinsic conformational flexibility that interferes with the formation of a crystal lattice. Here, the crystal structure of the human Pin1 WW domain has been obtained via racemic crystallization in the presence of small-molecule additives. Both enantiomers of a 36-residue variant of the Pin1 WW domain were synthesized chemically, and the l- and d-polypeptides were combined to afford diffracting crystals. The structural data revealed packing interactions of small carboxylic acids, either achiral citrate or a d,l mixture of malic acid, with a mobile loop region of the WW-domain fold. These interactions with solution additives may explain our success in crystallization of this protein racemate. Molecular-dynamics simulations starting from the structure of the Pin1 WW domain suggest that the crystal structure closely resembles the conformation of this domain in solution. The structural data presented here should provide a basis for further studies of this important model system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for detectors used with an 800 MU/min CyberKnife{sup ®} system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method

Purpose: In a previous work, output ratio (OR{sub det}) measurements were performed for the 800 MU/min CyberKnife{sup ®} at the Oscar Lambret Center (COL, France) using several commercially available detectors as well as using two passive dosimeters (EBT2 radiochromic film and micro-LiF TLD-700). The primary aim of the present work was to determine by Monte Carlo calculations the output factor in water (OF{sub MC,w}) and the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors. The secondary aim was to study the detector response in small beams using Monte Carlo simulation. Methods: The LINAC head of the CyberKnife{sup ®} was modeled using the PENELOPE Monte Carlo code system. The primary electron beam was modeled using a monoenergetic source with a radial gaussian distribution. The model was adjusted by comparisons between calculated and measured lateral profiles and tissue-phantom ratios obtained with the largest field. In addition, the PTW 60016 and 60017 diodes, PTW 60003 diamond, and micro-LiF were modeled. Output ratios with modeled detectors (OR{sub MC,det}) and OF{sub MC,w} were calculated and compared to measurements, in order to validate the model for smallest fields and to calculate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors, respectively. For the study of the influence of detector characteristics on their response in small beams; first, the impact of the atomic composition and the mass density of silicon, LiF, and diamond materials were investigated; second, the material, the volume averaging, and the coating effects of detecting material on the detector responses were estimated. Finally, the influence of the size of silicon chip on diode response was investigated. Results: Looking at measurement ratios (uncorrected output factors) compared to the OF{sub MC,w}, the PTW 60016, 60017 and Sun Nuclear EDGE diodes systematically over-responded (about +6% for the 5 mm field), whereas the PTW 31014 Pinpoint chamber systematically under-responded (about −12% for the 5 mm field). OR{sub det} measured with the SFD diode and PTW 60003 diamond detectors were in good agreement with OF{sub MC,w} except for the 5 mm field size (about −7.5% for the diamond and +3% for the SFD). A good agreement with OF{sub MC,w} was obtained with the EBT2 film and micro-LiF dosimeters (deviation less than 1.4% for all fields investigated). k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for several detectors used in this work have been calculated. The impact of atomic composition on the dosimetric response of detectors was found to be insignificant, unlike the mass density and size of the detecting material. Conclusions: The results obtained with the passive dosimeters showed that they can be used for small beam OF measurements without correction factors. The study of detector response showed that OR{sub det} is depending on the mass density, the volume averaging, and the coating effects of the detecting material. Each effect was quantified for the PTW 60016 and 60017 diodes, the micro-LiF, and the PTW 60003 diamond detectors. None of the active detectors used in this work can be recommended as a reference for small field dosimetry, but an improved diode detector with a smaller silicon chip coated with tissue-equivalent material is anticipated (by simulation) to be a reliable small field dosimetric detector in a nonequilibrium field.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-423: TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors

Purpose: To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon beams. Methods: The Exradin W1 is a new small volume near-water equivalent and energy independent PSD manufactured by Standard Imaging, Inc. All measurements were performed in an IBA Blue Phantom water tank. Square MLC-shaped fields with sides ranging from 0.5 cm to 2 cm and jawshaped fields with sides ranging from 1 cm to 40 cm were measured using an SAD setup at 10 cm depth. Dose profile and percent depth dose (PDD) measurements were also taken under the same conditions for MLC fields 0.5×0.5 and 1×1 cm2 in size with jaws at 2×2cm2. The CC01 and W1 were vertically mounted. Results: OFs measured with the W1 for jaw only square fields were consistent with the ones measured with a Farmers PTW TN33013 ion chamber (1.8% maximum deviation). OF and penumbra measurement results are presented below. PDDs measured for all detectors are within 1.5% for the 0.5×0.5 cm2 and within 1% for the 1×1 cm2 MLC fields.Output factors:MLC size W1 CC01 EDGE0.5cm 0.555 0.541 0.5851.0cm 0.716 0.702 0.7331.5cm 0.779 0.761 0.7772.0cm 0.804 0.785 0.796Penumbras (mm):MLC size W1 CC01 EDGE0.5cm 2.7 2.9 2.51.0cm 3.0 3.4 2. Conclusion: OFs measured for small MLC fields were consistent with the ones measured with the other stereotactic detectors. Measured penumbras are consistent with detector size. The Exradin W1 PSD is an excellent choice for characterizing MLC-shaped small beam dosimetry used for stereotactic radiosurgery and body radiation therapy. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field Radiotherapy”.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-457: Design and Characterization of An Economical 192Ir Hemi-Brain Small Animal Irradiator

Purpose: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. Methods: A high dose rate 192Ir brachytherapy source from a commercially available afterloader was used with a 1.3 centimeter thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit is equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film. The penumbra from the small animal irradiator was compared under similar collimating conditions to the penumbra from 6 MV photons, 6 MeV electrons, and 20 MeV electrons from a linear accelerator as well as 300 kVp photons from an orthovoltage unit and Monte Carlo simulated 90 MeV protons. Results: The tungsten collimator provides a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator. Additionally, the penumbra was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. Conclusions: The small animal irradiator described here can be built for under $1,000 and used in conjunction with any commercial brachytherapy afterloader to provide a convenient and cost-effective option for small animal irradiation experiments. The unit offers high dose rate delivery and sharp penumbra, which is ideal for hemi-brain irradiation of mice. With slight modifications to the design, irradiation of sites other than the brain could be accomplished easily. Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring a sharp penumbra.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-19A-08: PDD Discrepancies at Opposite Biases From Very Small Volume Ion Chambers When Using Water Scanners

Purpose: As more so-called micro ion chambers become commercially available, medical physicists may be inclined to use them during the linear accelerator commissioning process, in an attempt to better characterize the beam in steep dose gradient areas. The purpose of this work is to inform the medical physics community of a non-trivial, anomalous behavior observed when very small chambers are used in certain beam scanning configurations. Methods: A total of six ion chambers (0.007cc to 0.6cc) were used to scan PDDs from a 10×10cm2 field at both +300V and −300V biases. PDDs were scanned using three different water tank scanning systems to determine whether different scanners exhibit the same abnormality. Finally, PDDs were sampled using an external electrometer to bypass the internal electrometer of the scanner to determine the potential contributions of the scanner electronics to the abnormality observed. Results: We observed a reproducible, significant difference (over-response with depth) in PDDs acquired when using very small ion chambers with certain bias and watertank combinations, on the order of 3–5% at a depth of 25 cm in water. This difference was not observed when the PDDs were sampled using the ion chambers in conjunction with an external electrometer. This suggests a contribution of interference produced by the controller box and scanning system, which becomes significant for the very small signals collected by very small ion chambers, especially at depth, as the signal level is reduced even further. Conclusion: Based on the results observed here, if currently available very small ion chambers are used with specific bias and scanning water-tank combinations, erroneous PDD data may be collected. If this data is used as input to the Treatment Planning System, systematic errors on the order of 3%–5% may be introduced into the treatment planning process.

07 ISOTOPE AND RADIATION SOURCES↗

Sci—Fri AM: Mountain — 01: Validation of a new formulism and the related correction factors on output factor determination for small photon fields

Small field dosimetry measurements including output factors are difficult due to lack of charged-particle equilibrium, occlusion of the radiation source, the finite size of detectors, and non-water equivalence of detector components. With available detectors significant variations could be measured that will lead to incorrect delivered dose to patients. IAEA/AAPM have provided a framework and formulation to correct the detector response in small photon fields. Monte Carlo derived correction factors for some commonly used small field detectors are now available, however validation has not been performed prior to this study. An Exradin A16 chamber, EDGE detector and SFD detector were used to perform the output factor measurement for a series of conical fields (5–30mm) on a Varian iX linear accelerator. Discrepancies up to 20%, 10% and 6% were observed for 5, 7.5 and 10 mm cones between the initial output factors measured by the EDGE detector and the A16 ion chamber, while the discrepancies for the conical fields larger than 10 mm were less than 4%. After the application of the correction, the output factors agree well with each other to within 1%. Caution is needed when determining the output factors for small photon fields, especially for fields 10 mm in diameter or smaller. More than one type of detector should be used, each with proper corrections applied to the measurement results. It is concluded that with the application of correction factors to appropriately chosen detectors, output can be measured accurately for small fields.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Investigation of a Small Photomultiplier-Based Probe for Use in Beam Diagnostics and Medical Dosimetry

Purpose: Investigate the use of a small photomultiplier-based probe as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams was detected by a small photomultiplier tube (PMT). Measurements of Clinac beams were made both in air and by inserting the PMT directly into a water phantom. A conical collimator placed in front of the PMT reduced the angular acceptance and the detection of scattered light. With this arrangement, we obtained response curves as a function of depth along the central axis similar in shape and magnitude to those obtained with ionization chambers. Subsequent measurements were made with the PMT covered in aluminum foil, obtaining a signal arising primarily from direct Cerenkov light produced in the glass entrance window. With an oscilloscope and amplifier/MCA system, we were able to monitor the response to individual beam pulses and observe variations in the beam pulse shape and magnitude as a function of dose rate. Results: Using Cerenkov signals detected by a PMT, we were able to obtain reasonable beam quality metrics, and the response was found to be linear over a range of dose rates. The fast response of the PMT allowed for the observation of small changes in the shape and magnitude of the beam pulse. With this system we were able to detect small changes in the dose per pulse delivered by the accelerator. Conclusion: A small PMT probe has shown promise as a beam diagnostic and medical dosimetry tool. Its fast response allows for real time beam pulse monitoring, and the integrated response can yield relative and perhaps even absolute dose information with a properly calibrated system. For accelerator diagnostics, monitoring of the beam pulse shape can aid in beam tuning, particularly in electron mode, where no target current pulse is available.

60 APPLIED LIFE SCIENCES↗

Detector dose response in megavoltage small photon beams. I. Theoretical concepts

Purpose: To explain the reasons for significant quality correction factors in megavoltage small photon fields and clarify the underlying concepts relevant to dosimetry under such conditions. Methods: The validity of cavity theory and the requirement of charged particle equilibrium (CPE) are addressed from a theoretical point of view in the context of nonstandard beams. Perturbation effects are described into four main subeffects, explaining their nature and pointing out their relative importance in small photon fields. Results: It is demonstrated that the failure to meet classical cavity theory requirements, such as CPE, is not the reason for significant quality correction factors. On the contrary, it is shown that the lack of CPE alone cannot explain these corrections and that what matters most, apart from volume averaging effects, is the relationship between the lack of CPE in the small field itself and the density of the detector cavity. The density perturbation effect is explained based on Fano’s theorem, describing the compensating effect of two main contributions to cavity absorbed dose. Using the same approach, perturbation effects arising from the difference in atomic properties of the cavity medium and the presence of extracameral components are explained. Volume averaging effects are also discussed in detail. Conclusions: Quality correction factors of small megavoltage photon fields are mainly due to differences in electron density between water and the detector medium and to volume averaging over the detector cavity. Other effects, such as the presence of extracameral components and differences in atomic properties of the detection medium with respect to water, can also play an accentuated role in small photon fields compared to standard beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-E-06: Dosimetric Characterization of Small Photons Beams of a Novel Linear Accelerator

Purpose: The aim of the present contribution was to measure the main dosimetric quantities of small fields produced by UNIQUE and evaluate its matching with the corresponding dosimetric data of one 21EX conventional linear accelerator (Varian) in operation at the same center. The second step was to evaluate comparative performance of the EDGE diode detector and the PinPoint micro-ionization chamber for dosimetry of small fields. Methods: UNIQUE is configured with MLC (120 leaves with 0.5 cm leaf width) and a single low photon energy of 6 MV. Beam data were measured with scanning EDGE diode detector (volume of 0.019 mm{sup 3}), a PinPoint micro-ionization chamber (PTW) and for larger fields (≥ 4×4cm{sup 2}) a PTW Semi flex chamber (0.125 cm{sup 3}) was used. The scanning system used was the 3D cylindrical tank manufactured by Sun Nuclear, Inc. The measurement of PDD and profiles were done at 100 cm SSD and 1.5 depth; the relative output factors were measured at 10 cm depth. Results: PDD and the profile data showed less than 1% variation between the two linear accelerators for fields size between 2×2 cm{sup 2} and 5×5cm{sup 2}. Output factor differences was less than 1% for field sizes between 3×3 cm{sup 2} and 10×10 cm{sup 2} and less of 1.5 % for fields of 1.5×1.5 cm{sup 2} and 2×2 cm{sup 2} respectively. The dmax value of the EDGE diode detector, measured from the PDD, was 8.347 mm for 0.5×0,5cm{sup 2} for UNIQUE. The performance of EDGE diode detector was comparable for all measurements in small fields. Conclusion: UNIQUE linear accelerator show similar dosimetrics characteristics as conventional 21EX Varian linear accelerator for small, medium and large field sizes.EDGE detector show good performance by measuring dosimetrics quantities in small fields typically used in IMRT and radiosurgery treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-F-T-557: Evaluation of Detector Response in Rectangular Small Field Dosimetry

Purpose: As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accelerator. Methods: Two Dosimeters, the Exradin A26 Microionization Chamber (Standard Imaging) and Edge Diode Detector (Sun Nuclear) were used to measure output factors taken on the Varian Edge Stereotactic Linear accelerator. Measurements were taken at 6MV and 6FFF at 10cm depth, 100cm SSD in a 48×48×40cm3 Welhoffer BluePhantom2 (IBA) with X and Y jaws set from 0.6 to 2.0cm. Output factors were normalized to a 5×5cm2 machine-specific reference field. Measurements were made in the vertical orientation for the A26 and horizontal orientation for both the A26 and Edge. Output factors were measured as: OF{sub FS} = M{sub FS}/M{sub ref} where M{sub FS} and M{sub ref} are the measured signals for the clinical field and the reference field, respectively. Measured output factors were then analyzed to establish relative responses of the detectors in small fields. Results: At 6MV the Edge detector exhibited a variation in output factors dependent on jaw positioning (X-by-Y vs Y-by-X) of 5.7% of the 5×5cm reference output and a variation of 3.33% at 6FFF. The A26 exhibited variation of output factor dependent on jaw positioning of upto 7.7% of the 5×5cm reference field at 6MV and upto 5.33% at 6FFF. Conclusion: Both the Edge detector and A26 responded as expected at small fields however a dependence on the jaw positioning was noted. At 6MV and 6FFF the detector response showed an increased dependence on the positioning of the X jaws as compared to the positioning of the Y jaws.

60 APPLIED LIFE SCIENCES↗

TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with the source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.

60 APPLIED LIFE SCIENCES↗

Subcritical Small-Scale Dynamo in a Helical Random Flow

The possibility of the growth of a small-scale dynamo in a random flow with a weak mirror asymmetry under subcritical generation conditions is investigated. We show that the appearance of an asymmetry in a flow with nonzero helicity leads to the generation of small-scale periodic perturbations. These perturbations, in turn, support active field generation on small scales. We describe the properties of this support, the generation rate, and the characteristic scales dependent on the velocity of the random flow and the degree of its helicity. Transferring the problem to the spectral domain, we demonstrate the formation of a two-component small- and large-scale spectrum that consists of a peak localized on large scales and power laws at large and small k. The possibility of directly checking the spectral properties being described in subcritical laboratory MHD conditions is specially noted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small-scale clumps in the Galactic halo

A mass function of small-scale dark matter clumps is calculated. We take into account the tidal destruction of clumps at early stages of structure formation starting from a time of clump detachment from the Universe expansion. Only a small fraction of these clumps, {approx}0.1%, in each logarithmic mass interval {Delta} log M {approx} 1 survives the stage of hierarchical clustering. We calculate the probability of surviving of the remnants of dark matter clumps in the Galaxy by modelling the tidal destruction of the small-scale clumps by disk and stars. It is demonstrated that a substantial fraction of clump remnants may survive through the tidal destruction during the lifetime of the Galaxy if a radius of core is rather small. The resulting mass spectrum of survived clumps is extended down to the mass of the core of the cosmologically produced clumps with a minimal mass. The survived dense remnants of tidally destructed clumps provides a large contribution to the annihilation signal in the Galaxy. We describe the anisotropy of dark matter clump distribution caused by tidal destruction of clumps in the Galactic disk. A corresponding annihilation of dark matter particles in small-scale clumps produces the anisotropic gamma-ray signal with respect to the Galactic disk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural and Kinetic Studies of Novel Cytochrome P450 Small-Alkane Hydroxylases

The goals of this project are to investigate (1) the kinetics and stabilities of engineered cytochrome P450 (P450) small alkane hydroxylases and their evolutionary intermediates, (2) the structural basis for catalytic proficiency on small alkanes of these engineered P450s, and (3) the changes in redox control resulting from protein engineering. To reach these goals, we have established new methods for determining the kinetics and stabilities of multicomponent P450s such as CYP153A6. Using these, we were able to determine that CYP153A6 is proficient for hydroxylation of alkanes as small as ethane, an activity that has never been observed previously in any natural P450. To elucidate the structures of the engineered P450s, we obtained x-ray diffraction data for two variants in the P450 PMO (propane monooxygenase) lineage and a preliminary structure for the most evolved variant. This structure shows changes in the substrate binding regions of the enzyme and a reduction in active site volume that are consistent with the observed changes in substrate specificity from fatty acids in the native enzyme to small alkanes in P450 PMO . We also constructed semi-rational designed libraries mutating only residues in the enzyme active site that in one round of mutagenesis and screening produced variants that achieved nearly half of the activity of the most evolved enzymes of the P450 PMO lineage. Finally, we found that changes in redox properties of the laboratory-evolved P450 alkane hydroxylases did not reflect the improvement in their electron transfer efficiency. The heme redox potential remained constant throughout evolution, while activity increased and coupling efficiency improved from 10% to 90%. The lack of correlation between heme redox potential and enzyme activity and coupling efficiency led us to search for other enzyme properties that could be better predictors for activity towards small alkanes, specifically methane. We investigated the oxidation potential of the radical oxidants of various P450s directly using a chemical approach to generate the radical in situ . This resulted in the first report of direct methane to methanol conversion by a heme porphyrin catalyst using the soluble P450 from Mycobacterium sp , CYP153A6.

03 NATURAL GAS↗

Dislocation dynamics simulations of plasticity at small scales

As metallic structures and devices are being created on a dimension comparable to the length scales of the underlying dislocation microstructures, the mechanical properties of them change drastically. Since such small structures are increasingly common in modern technologies, there is an emergent need to understand the critical roles of elasticity, plasticity, and fracture in small structures. Dislocation dynamics (DD) simulations, in which the dislocations are the simulated entities, offer a way to extend length scales beyond those of atomistic simulations and the results from DD simulations can be directly compared with the micromechanical tests. The primary objective of this research is to use 3-D DD simulations to study the plastic deformation of nano- and micro-scale materials and understand the correlation between dislocation motion, interactions and the mechanical response. Specifically, to identify what critical events (i.e., dislocation multiplication, cross-slip, storage, nucleation, junction and dipole formation, pinning etc.) determine the deformation response and how these change from bulk behavior as the system decreases in size and correlate and improve our current knowledge of bulk plasticity with the knowledge gained from the direct observations of small-scale plasticity. Our simulation results on single crystal micropillars and polycrystalline thin films can march the experiment results well and capture the essential features in small-scale plasticity. Furthermore, several simple and accurate models have been developed following our simulation results and can reasonably predict the plastic behavior of small scale materials.

36 MATERIALS SCIENCE↗

Small Hydro Reference Model Project (Final Project Report)

Small hydropower has long been developed in the United States, but still thousands of small hydro sites remain untapped. Most of them are technically and environmentally feasible but may not be cost-effective to develop at the current level of technology and carbon and fuel markets. This report aims to identify the cost drivers for small hydro generation through cost analyses, and to improve understanding of the pathways for cost reduction and the strategies for accelerating small hydro development in the United States. Reference to the empirical cost equations in literature, an initial capital cost (ICC) equation for nonpowered dam (NPD) and conduit projects has been preliminarily developed using limited project cost data collected from the Federal Energy Regulatory Commission (FERC) e-library and directly from industrial contacts. The regression analysis shows a correlation between the project ICC and plant capacity and head. The electro-mechanical equipment costs for Francis, axial flow, Kaplan, and propeller turbines are derived from the historical budget prices of a small hydro turbine manufacturer. These cost curves show the turbine-generator cost is also associated with the plant capacity and net head. In addition, the initial cost breakdowns are analyzed based on project cost data from literature and industry. It was found that the turbine-generator and the powerhouse are often the major cost components for low-head projects, whereas water conveyance is likely to be the key cost driver for high-head projects. The ICC variations for different site features, such as new greenfield sites vs. non-powered dams, are also discussed.

Zhang, Qin Fen (Katherine)↗

Small File Aggregation with PLFS [Slides]

Today’s computational science demands have resulted in ever larger parallel computers, and storage systems have grown to match these demands. Parallel file systems used in this environment are increasingly specialized to extract the highest possible performance for large I/O operations, at the expense of other potential workloads. While some applications have adapted to I/O best practices and can obtain good performance on these systems, the natural I/O patterns of many applications result in the generation of a huge number of small files, the creation of which is poorly served by current parallel file systems at very large scale. This paper describes a new technique for optimizing small file access in parallel file systems for these very large scale systems. The idea is to use a virtual parallel log-structure file system on the compute nodes in order to aggregate large numbers of small files in compute node memory and then stream their data sequentially to a much smaller number of physical files on an underlying parallel file system. The technique is implemented and evaluated using PLFS as the aggregating middleware. We evaluate our system with micro-benchmarks on a local OSX filesystem and with an MPI extension of the standard Postmark to provide results at scale on both Lustre and PanFS parallel filesystems. We observe as much as a 33x improvement in small file create rates on a single host, and 30x improvement in small file write rates, compared to a baseline Lustre configuration on a leadership computing platform using 16,384 cores and achieve an unprecedented create rate of 200 million files per second.

97 MATHEMATICS AND COMPUTING↗