Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

An automated mapping satellite system

Topographic maps are compiled by manually operated stereoplotters that recreate the geometry of two wide-angle overlapping stereo frame photographs. Continuous imaging systems such as strip cameras, electro-optical scanners, or linear arrays of detectors (push brooms) can also create stereo coverage from which topography can be compiled; however, the instability of an aircraft in the atmosphere makes this approach impractical. The benign environment of space permits a satellite to orbit the Earth with very high stability as long as no local perturbing forces are involved. Solid-state linear-array sensors have no moving parts and create no perturbing force on the satellite. Digital data from highly stabilized stereo linear arrays are amenable to simplified processing to produce both planimetric imagery and elevation data. A proposed satellite, called MAPSAT, could accomplish automated mapping in near real time. Image maps as large as 1:50,000 scale with contours as close as 20-m interval may be produced from MAPSAT data.

Colvocoreses, A. P.↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental determination of cosmic ray charged particle intensity profiles in the atmosphere

Absolute cosmic-ray free air ionization and charged particle fluxes and dose rates throughout the atmosphere were measured on a series of balloon flights that commenced in 1968. Argon-filled ionization chambers equipped with solid-state electrometers, with different gas pressures and steel wall thicknesses, and a pair of aluminum-wall Gm counters have provided the basic data. These data are supplemented by measurements with air-filled and tissue equivalent ionization chambers and a scintillation spectrometer. Laboratory experiments together with analyses of the theoretical aspects of the detector responses to cosmic radiation indicate that these profiles can be determined to an overall accuracy of + or - 5 percent.

Lowder, W. M.↗

X-ray spectroscopy of supernova remnants

The information which can be obtained from X-ray spectroscopy of supernova remnants is considerd. The fitting of X-ray detector counts to models of the incident spectrum is discussed, and the types of thermal emission models generally employed are presented, including the power law, black body, and thermal bremsstrahlung models of the continua and models of the emission of a hot, optically thin plasma in collisional equilibrium. Observations of 12 supernova remnants made with the Solid State Spectrometer on board the Einstein Observatory are reported, and metal abundances inferred from the lines of the eight remnants showing thermal spectra are summarized. Questions raised by the failure to observe the overabundance of Fe predicted by stellar evolution and hydrodynamic modeling are discussed, and the need to develop more detailed models of the conditions in a supernova remnant in order to interpret the X-ray spectra is noted.

Szymkowiak, A. E.↗

Temperature Control of Avalanche Photodiode Using Thermoelectric Cooler

Avalanche photodiodes (APDS) are quantum optical detectors that are used for visible and near infrared optical detection applications. Although APDs are compact, rugged, and have an internal gain mechanism that is suitable for low light intensity; their responsivity, and therefore their output, is strongly dependent on the device temperature. Thermoelectric coolers (TEC) offers a suitable solution to this problem. A TEC is a solid state cooling device, which can be controlled by changing its current. TECs are compact and rugged, and they can precisely control the temperature to within 0.1 C with more than a 150 C temperature gradient between its surfaces. In this Memorandum, a proportional integral (PI) temperature controller for APDs using a TEC is discussed. The controller is compact and can successfully cool the APD to almost 0 C in an ambient temperature environment of up to 27 C.

Refaat, Tamer F.↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

Continuous Magnetic Refrigerators for Cooling in the 0.05 to 10 K Range

Low temperature refrigeration is an increasingly vital technology for NASA's Space Science program since most detectors being developed for x-ray, IR and sub-millimeter missions must be cooled to below 100 mK in order to meet the requirements for energy and spatial resolution. For space applications, magnetic refrigeration has an inherent advantage over alternative techniques because it does not depend on gravity. Adiabatic demagnetization refrigerators, or ADRs, are relatively simple, solid state devices. The basic elements are a magnetocaloric refrigerant (usually an encapsulated paramagnetic salt) located in the bore of a superconducting magnet, and a heat switch linking the salt to a heat sink. The alignment of magnetic spins with the magnetic field causes the refrigerant to warm as the magnetic field increases and cool as the field decreases. Thus the simple process of magnetizing the refrigerant to high field with the heat switch closed, then demagnetizing it with the heat switch open allows one to obtain temperatures well below 100 mK using a heat sink as warm as 4.2 K. The refrigerant can maintain a low temperature for a length of time depending on the applied and parasitic heat loads, its mass, and the initial magnetic field strength. Typically ADRs are designed for 12-24 hours of hold time, after which they must be warmed up and recycled.

Shirron, Peter↗

Continuous Magnetic Refrigerators for Cooling in the 0.05 to 10 K Range: Progress and Future Development

Low temperature refrigeration is an increasingly vital technology for NASA s Space Science program since most detectors being developed for x-ray, IR and sub-millimeter missions must be cooled to below 100 mK in order to meet the requirements for energy and spatial resolution. For space applications, magnetic refrigeration has an inherent advantage over alternative techniques because it does not depend on gravity. Adiabatic demagnetization refrigerators, or ADRs, are relatively simple, solid state devices. The basic elements are a magnetocaloric refrigerant (usually an encapsulated paramagnetic salt) located in the bore of a superconducting magne$, and a heat switch linking the salt to a heat sink. The alignment of magnetic spins with the magnetic field causes the refrigerant to warm as the magnetic field increases and cool as the field decreases. Thus the simple process of magnetizing the refrigerant to high field with the heat switch closed, then demagnetizing it with the heat switch open allows one to obtain temperatures well below 100 mK using a heat sink as warm as 4.2 K. The refrigerant can maintain a low temperature for a length of time depending on the applied and parasitic heat loads, its mass, and the initial magnetic field strength. Typically ADRs are designed for 12-24 hours of hold time, after which they must be warmed up and recycled. The drawback to single-shot ADRs is that the cooling power per unit mass is relatively low. Refrigerants that are suitable for low temperature operation necessarily have low magnetic ion density, and therefore low entropy density. Since ADRs store entropy, systems with even modest cooling powers (a few microwatts) at temperatures below 100 mK tend to be massive, averaging 10-15 kg.

Shirron, Peter↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Radionuclide measurements by accelerator mass spectrometry at Arizona

Over the past years, Tandem Accelerator Mass Spectrometry (TAMS) has become established as an important method for radionuclide analysis. In the Arizona system the accelerator is operated at a thermal voltage of 1.8MV for C-14 analysis, and 1.6 to 2MV for Be-10. Samples are inserted into a cesium sputter ion source in solid form. Negative ions sputtered from the target are accelerated to about 25kV, and the injection magnet selects ions of a particular mass. Ions of the 3+ charge state, having an energy of about 9MeV are selected by an electrostatic deflector, surviving ions pass through two magnets, where only ions of the desired mass-energy product are selected. The final detector is a combination ionization chamber to measure energy loss (and hence, Z), and a silicon surface-barrier detector which measures residual energy. After counting the trace iosotope for a fixed time, the injected ions are switched to the major isotope used for normalization. These ions are deflected into a Faraday cup after the first high-energy magnet. Repeated measurements of the isotope ratio of both sample and standards results in a measurement of the concentration of the radionuclide. Recent improvements in sample preparation for C-14 make preparation of high-beam current graphite targets directly from CO2 feasible. Except for some measurements of standards and backgrounds for Be-10 measurements to date have been on C-14. Although most results have been in archaeology and quaternary geology, studies have been expanded to include cosmogenic C-14 in meteorites. The data obtained so far tend to confirm the antiquity of Antarctic meteorites from the Allan Hills site. Data on three samples of Yamato meteorites gave terrestrial ages of between about 3 and 22 thousand years.

Jull, A. J. T.↗

Splitting phonons: Building a platform for linear mechanical quantum computing

Linear optical quantum computing provides a desirable approach to quantum computing, with only a short list of required computational elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing using phonons in place of photons. Although single-phonon sources and detectors have been demonstrated, a phononic beam splitter element remains an outstanding requirement. Here we demonstrate such an element, using two superconducting qubits to fully characterize a beam splitter with single phonons. We further use the beam splitter to demonstrate two-phonon interference, a requirement for two-qubit gates in linear computing. In conclusion, this advances a new solid-state system for implementing linear quantum computing, further providing straightforward conversion between itinerant phonons and superconducting qubits.

97 MATHEMATICS AND COMPUTING↗

X-Ray Spectroscopy Using Low Temperature Detectors

After several decades of development, a significant amount of the effort in low temperature detectors (LTDs) is concentrated on deploying real-world experiments. This has resulted from a great deal of basic detector physics performed by several generations of students, post-docs, and researchers. One of the most fruitful applications of LTDs is in non-dispersive x-ray spectroscopy. LTD x-ray spectrometers are broadband, efficient, moderately high-resolution, and can handle moderately high count rates. However, they require significantly more power, mass, and infrastructure compared to traditional solid state x-ray spectrometers, and cannot achieve, at least at low energies, the resolving powers achieved with dispersive spectrometers. In several fields, however, LTDs have or will make a significant contribution. In this review, we will discuss x-ray spectroscopy in general, the fields of science where LTDs are making a significant impact, and some of the current and near-term LTD spectrometers.

Porter, Frederick↗

Thermal Processing Conditions for the Synthesis of Near Theoretical Density Li 5 La 3 Ta 2 O 12 Ceramics for Ceramic Dual-Mode Detectors

A family of Li-containing garnet compounds, extensively investigated for Li-ion solid electrolyte applications, show great potential to be developed into transparent ceramic dual-mode scintillators. In particular, Li 5 La 3 Ta 2 O 12 (LLTaO) shows promise as an efficient dual-mode scintillator due to its high Li content, high density, non-hygroscopicity, and high effective-Z. Often the synthesis of LLTaO ceramics involves solid state processing techniques starting with oxide and carbonate powders, calcining, sintering for the removal of residual porosity, and post-processing. This study focuses on two objectives: (1) establishing thermal processing boundary conditions for a flexible alkoxide-based sol-gel method for synthesizing fine-grained powders; and (2), consolidating powders via hot-pressing to form high-density ceramics. In this study, near single-phase ceramics were achieved by hot-pressing sol-gel powders with varying amounts of excess Li. Rietveld refinements were used to analyze X-ray diffraction data and provide a quantitative evaluation of the phases present in the hot pressed ceramics. Some of the diffraction data showed large low angle peak asymmetry, suggesting the presence of two cubic Li 5 La 3 Ta 2 O 12 garnet phases with different lattice parameters. Depending on the synthesis and processing conditions, the refinement revealed ~ 90 wt% concentration of a phase with a ≈ 12.8 Å and ~ 10 wt% concentration of a phase with a ≈ 12.9 Å, indicating a remaining excess of Li in the hot pressed ceramics in the large lattice parameter phase. These synthesis experiments allowed for the determination of a baseline for Li loss during hot-pressing. X-ray excited radioluminescence and photoluminescence excitation and emission spectra were obtained from the hot pressed ceramics. In conclusion, the measured emission spectra featured broad tantalate emission and line emissions likely from a rare-earth impurity.

36 MATERIALS SCIENCE↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

High-Performance Thermoelectric Semiconductors

Figures of merit almost double current state-of-art thermoelectric materials. IrSb3 is semiconductor found to exhibit exceptional thermoelectric properties. CoSb3 and RhSb3 have same skutterudite crystallographic structure as IrSb3, and exhibit exceptional transport properties expected to contribute to high thermoelectric performance. These three compounds form solid solutions. Combination of properties offers potential for development of new high-performance thermoelectric materials for more efficient thermoelectric power generators, coolers, and detectors.

Fleurial, Jean-Pierre↗