Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Code Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Performance Improvements for the Griffin Transport Solvers

Griffin is a Multiphysics Object-Oriented Simulation Environment based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. Griffin includes a variety of deterministic radiation transport solvers for fixed source, k-eigenvalue, adjoint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. A code assessment performed in FY-20 identified two significant issues with the transport solvers in Griffin: first, the primary heterogeneous SN (discrete ordinates) transport solver based on continuous finite element methods required significant mesh refinement and higher memory usage compared to solvers based on the method of characteristic for equivalent accuracy. Second, the homogeneous PN (spherical harmonics expansion) transport solver did not adequately support polynomial refinement, which is a feature usually required for problems with spatial homogenization and pronounced streaming, typical in fast or gas-cooled reactor systems. To address the first issue, the development effort focused on the more promising discontinuous finite element method (DFEM)-based SN transport solver in Griffin. The addition of an asynchronous parallel transport sweeper and coarse mesh finite difference (CMFD) acceleration have rendered a superior heterogeneous SN transport capability for multiphysics problems that requires far less computing resources in terms of both CPU time and memory usage. This is demonstrated with typical thermal- and fast-spectrum reactor benchmark problems, including 2D Transient Reactor Test, 3D Advanced Burner Test Reactor (ABTR), and 2D and 3D Empire microreactor. For the second issue, the development effort focused on a new transport solver based on the hybrid finite element PN method (HFEM-PN), equivalent to the variational nodal method, as well as a new diffusion solver based on HFEM-Diffusion. This solver is intended for homogenized domains with multiphysics coupling (i.e., supports mesh displacement, seamless temperature feedback, etc.). Initial calculations with the HFEM-Diffusion implementation show very good parallel efficiency for the residual evaluations with the 2D ABTR benchmark. A future development effort will be centered on further improvements to the CMFD, HFEM-PN, and DFEM diffusion solvers to ensure Griffin meets performance and software quality assurance requirements for advanced reactor design and analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of rapid increase in the plasma density during the ramp-up phase in a radio frequency negative ion source by large-scale particle simulation

Numerical simulations become useful for the developing RF-ICP (Radio Frequency Inductively Coupled Plasma) negative ion sources. We are developing and parallelizing a two-dimensional three velocity electromagnetic Particle-In-Cell code. The result shows rapid increase in the electron density during the density ramp-up phase. A radial electric field due to the space charge is produced with increase in the electron density and the electron transport in the radial direction is suppressed. As a result, electrons stay for a long period in the region where the inductive electric field is strong, and this leads efficient electron acceleration and a rapid increasing of the electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Code Coverage Status of the ARC Code PERSENT

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. PERSENT fulfills the role of generating reactivity coefficients for a given time point of a REBUS calculation usable in a point kinetics based safety analysis capability. PERSENT also provides a sensitivity coefficient capability on eigenvalue, reactivity worth, and several other key coefficients that are used in the follow-on safety analysis. Given a co-variance matrix, PERSENT can carry out the uncertainty quantification to indicate the amount of error in the reactivity coefficients derived from the errors in the cross section measurements. With continued improvement of computational resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. PERSENT is part of the ARC code system and is built around DIF3D-VARIANT and the flux solution it provides. The purpose of the present work is to identify a set of test problems for PERSENT and assess the code coverage of PERSENT for those test problems. PERSENT treats the DIF3D executable as an external executable and thus the code coverage considerations only need to focus on the PERSENT source code and only a fraction of the connected modules in the existing ARC software library. The goal is to document what parts of the existing PERSENT code are touched by the set of test problems and which are not. Because the verification work done on PERSENT was focused on the most common uses of PERSENT for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that users of PERSENT rely upon. The code coverage analysis of PERSENT was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of PERSENT. The detailed coverage tables are given for each submodule of PERSENT. Most of the uncovered parts/files could be easily ignored because they are either for error message and debugging output or not needed by PERSENT today. Only a few uncovered parts of PERSENT deserve extending the verification test suite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Physical models, cross sections, and numerical approximations used in MCNP and GEANT4 Monte Carlo codes for photon and electron absorbed fraction calculation

Purpose: Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most of them used Monte Carlo radiation transport codes. Despite the widespread use of these codes due to the variety of resources and potentials they offered to carry out dose calculations, several aspects like physical models, cross sections, and numerical approximations used in the simulations still remain an object of study. Accurate dose estimate depends on the correct selection of a set of simulation options that should be carefully chosen. This article presents an analysis of several simulation options provided by two of the most used codes worldwide: MCNP and GEANT4. Methods: For this purpose, comparisons of absorbed fraction estimates obtained with different physical models, cross sections, and numerical approximations are presented for spheres of several sizes and composed as five different biological tissues. Results: Considerable discrepancies have been found in some cases not only between the different codes but also between different cross sections and algorithms in the same code. Maximum differences found between the two codes are 5.0% and 10%, respectively, for photons and electrons.Conclusion: Even for simple problems as spheres and uniform radiation sources, the set of parameters chosen by any Monte Carlo code significantly affects the final results of a simulation, demonstrating the importance of the correct choice of parameters in the simulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the VERA Core Physics Benchmark Problems using cosRMC Code

In reactor physics, two kinds of numerical methods are generally employed to solve the neutron transport equations, one of which is the deterministic method and the other one is the Monte Carlo method. Monte Carlo is widely used to provide reference solution because of its ability to deal with continuous energy cross sections and complex geometry. Just like any statistical process, the Monte Carlo method requires repetition to achieve a small relative uncertainty, and therefore may inevitably have larger simulation times than deterministic method. Fortunately, the great advancements of computer technology make it possible to apply Monte Carlo method in reactor core analysis. To promote nuclear power plant system design and simulation software self-reliance development, a Monte Carlo neutron/photon transport code cosRMC has been developed jointly by State Nuclear Power Software Development Center (SNPSDC) and Tsinghua University. The cosRMC is aimed at achieving full core calculations and analysis with high fidelity and efficiency by means of advanced methodologies and algorithms as well as high performance computing techniques. The cosRMC has many functions as criticality calculation, fixed-source calculation, burnup calculation, etc. In order to ensure its reliability, several types of verification and validation (V and V) work have been and are being carried out for cosRMC. The simulation results of cosRMC based on Problem 1 to 3 of VERA Core Physics Benchmark showed its good capability of 2D lattice and 3D assembly modeling. In this paper, some progressive verification results of multi-assembly and full core problems are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Truchas Overview

Truchas and Truchas-PBF are two sister codes for part-scale multi-physics modeling of manufacturing processes. Both programs are open source and made publicly available. They’re designed for efficient use of HPC resources and can be programmatically driven from Python packages. This enables automatic execution and analysis of ensembles of simulations, in some cases allowing 1000s of simulations to be evaluated in a day on HPC. Beyond just giving engineers a window into the concealed internal state of a system, the goal of Truchas is to provide a framework for developing novel manufacturing processes by understanding how the entire space of engineering inputs affects thermal state. It often is used to explore combinations of capabilities uncommon in commercial software, or to scale up analyses beyond the capabilities of commercial software.

97 MATHEMATICS AND COMPUTING↗

RMC - A Monte Carlo code for reactor physics analysis

A new Monte Carlo neutron transport code RMC has been being developed by Department of Engineering Physics, Tsinghua University, Beijing as a tool for reactor physics analysis on high-performance computing platforms. To meet the requirements of reactor analysis, RMC now has such functions as criticality calculation, fixed-source calculation, burnup calculation and kinetics simulations. Some techniques for geometry treatment, new burnup algorithm, source convergence acceleration, massive tally and parallel calculation, and temperature dependent cross sections processing are researched and implemented in RMC to improve the efficiency. Validation results of criticality calculation, burnup calculation, source convergence acceleration, tallies performance and parallel performance shown in this paper prove the capabilities of RMC in dealing with reactor analysis problems with good performances. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Particle transport and heat loads in NIO1

NIO1 is a compact radio frequency ion source designed to generate a 60 kV-135 mA hydrogen negative ion beam and it aims at continuous operation, which implies a detailed thermo-mechanical analysis of the beam-facing components, in particular, the accelerator grids. A 3D analysis of the entire NIO1 beam has been performed for the first time with a fully 3D version of EAMCC, a relativistic particle tracking code for the calculation of the grid power deposition induced by particle impacts. According to the results presented in this paper, secondary and co-extracted electrons cause a non-negligible heat load on the grids, where different high-power density regions, within reasonable sustainable standard limits, are calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ENHANCING SEISMIC CALIBRATION RESEARCH THROUGH SOFTWARE AUTOMATION AND SCIENTIFIC INFORMATION MANAGEMENT

The National Nuclear Security Administration (NNSA) Ground-Based Nuclear Explosion Monitoring Research and Development (GNEMRD) Program at LLNL continues to make significant progress enhancing the process of deriving seismic calibrations and performing scientific integration, analysis, and information management with software automation tools. Our tool efforts address the problematic issues of very large datasets and varied formats encountered during seismic calibration research. New information management and analysis tools have resulted in demonstrated gains in efficiency of producing scientific data products and improved accuracy of derived seismic calibrations. The foundation of a robust, efficient data development and processing environment is comprised of many components built upon engineered versatile libraries. We incorporate proven industry 'best practices' throughout our code and apply source code and bug tracking management as well as automatic generation and execution of unit tests for our experimental, development and production lines. Significant software engineering and development efforts have produced an object-oriented framework that provides database centric coordination between scientific tools, users, and data. Over a half billion parameters, signals, measurements, and metadata entries are all stored in a relational database accessed by an extensive object-oriented multi-technology software framework that includes stored procedures, real-time transactional database triggers and constraints, as well as coupled Java and C++ software libraries to handle the information interchange and validation requirements. Significant resources were applied to schema design to enable management of processing methods and station parameters, responses and metadata. This allowed for the development of merged ground-truth (GT) data sets compiled by the NNSA labs and AFTAC that include hundreds of thousands of events and tens of millions of arrivals. The schema design groundwork facilitated extensive quality-control and revalidation steps. In support of the GT merge effort, a comprehensive site merge process was also accomplished this year that included station site information for tens of thousands of entries from NNSA labs, AFTAC, NEIC, ISC, and IRIS. A core capability is the ability to rapidly select and present subsets of related signals and measurements to the researchers for analysis and distillation both visually (JAVA GUI client applications) and in batch mode (instantiation of multi-threaded applications on clusters of processors). RBAP Version 2 is one such example. Over the past year RBAP was significantly improved in capability and performance. A new role-based security model now allows fine-grain access control over all aspects of the tool's functions enabling researchers to share their work with others without fear of unintended parameter alterations. A new, faster and more reliable GIS mapping framework was added, as well as expanded powerful interactive plotting graphics. In addition, we implemented parent-child type projects to enhance calibration data management. Our specific automation methodology and tools improve the researchers ability to assemble quality-controlled research products for delivery into the NNSA Knowledge Base (KB). The software and scientific automation tasks provide the robust foundation upon which synergistic and efficient development of GNEMRD Program seismic calibration research may be built.

58 GEOSCIENCES↗

Genome-Scale 13 C Fluxomics Modeling for Metabolic Engineering of Saccharomyces cerevisiae .

Synthetic biology is a rapidly developing field that pursues the application of engineering principles and development approaches to biological engineering. Synthetic biology is poised to change the way biology is practiced, and has important practical applications: for example, building genetically engineered organisms to produce biofuels, medicines, and other chemicals. Traditionally, synthetic biology has focused on manipulating a few genes (e.g., in a single pathway or genetic circuit), but its combination with systems biology holds the promise of creating new cellular architectures and constructing complex biological systems from the ground up. Enabling this merge of synthetic and systems biology will require greater predictive capability for modeling the behavior of cellular systems, and more comprehensive data sets for building and calibrating these models. The so-called "-omics" data sets can now be generated via high throughput techniques in the form of genomic, proteomic, transcriptomic, and metabolomic information on the engineered biological system. Of particular interest with respect to the engineering of microbes capable of producing biofuels and other chemicals economically and at scale are metabolomic datasets, and their insights into intracellular metabolic fluxes. Metabolic fluxes provide a rapid and easy to understand picture of how carbon and energy flow throughout the cell. Furthermore, we present a detailed guide to performing metabolic flux analysis and modeling using the open source JBEI Quantitative Metabolic Modeling (jQMM) library. This library allows the user to transform metabolomics data in the form of isotope labeling data from a 13 C labeling experiment into a determination of cellular fluxes that can be used to develop genetic engineering strategies for metabolic engineering.The jQMM library presents a complete toolbox for performing a range of different tasks of interest in metabolic engineering. Various different types of flux analysis and modeling can be performed such as flux balance analysis, 13 C metabolic flux analysis, and two-scale 13 C metabolic flux analysis (2S- 13 C MFA). 2S- 13 C MFA is a novel method that determines genome-scale fluxes without the need of every single carbon transition in the metabolic network. In addition to several other capabilities, the jQMM library can make model based predictions for how various genetic engineering strategies can be incorporated toward bioengineering goals: it can predict the effects of reaction knockouts on metabolism using both the MoMA and ROOM methodologies. In this chapter, we will illustrate the use of the jQMM library through a step-by-step demonstration of flux determination and knockout prediction in a complex eukaryotic model organism: Saccharomyces cerevisiae ( S. cerevisiae ). Included with this chapter is a digital Jupyter Notebook file that provides a computable appendix showing a self-contained example of jQMM usage, which can be changed to fit the user's specific needs. As an open source software project, users can modify and extend the code base to make improvements at will, allowing them to share their development work and contribute back to the jQMM modeling community.

-Omics data↗

Planck 2013 results. I. Overview of products and scientific results

The European Space Agency's Planck satellite, dedicated to studying the early Universe and its subsequent evolution, was launched 14 May 2009 and has been scanning the microwave and submillimetre sky continuously since 12 August 2009. In March 2013, ESA and the Planck Collaboration released the initial cosmology products based on the first 15.5 months of Planck data, along with a set of scientific and technical papers and a web-based explanatory supplement. This report gives an overview of the mission and its performance, the processing, analysis, and characteristics of the data, the scientific results, and the science data products and papers in the release. The science products include maps of the cosmic microwave background (CMB) and diffuse extragalactic foregrounds, a catalogue of compact Galactic and extragalactic sources, and a list of sources detected through the Sunyaev-Zeldovich effect. The likelihood code given to assess cosmological models against the Planck data and a lensing likelihood are described. Scientific results include robust support for the standard six-parameter ΛCDM model of cosmology and improved measurements of its parameters, including a highly significant deviation from scale invariance of the primordial power spectrum. The Planck values for these parameters and others derived from them are significantly different from those previously determined. Several large-scale anomalies in the temperature distribution of the CMB, first detected by WMAP, are confirmed with higher confidence. Planck sets new limits on the number and mass of neutrinos, and has measured gravitational lensing of CMB anisotropies at greater than 25σ. Planck finds no evidence for non-Gaussianity in the CMB. Planck's results agree well with results from the measurements of baryon acoustic oscillations. Planck finds a lower Hubble constant than found in some more local measures. Some tension is also present between the amplitude of matter fluctuations (σ8) derived from CMB data and that derived from Sunyaev-Zeldovich data. The Planck and WMAP power spectra are offset from each other by an average level of about 2% around the first acoustic peak. Analysis of Planck polarization data is not yet mature, therefore polarization results are not released, while the robust detection of E -mode polarization around CMB hot and cold spots is shown graphically.

79 ASTRONOMY AND ASTROPHYSICS↗

Scoping Analyses on Tritium Permeation to VHTR Integarted Industrial Application Systems

Tritium permeation is a very important current issue in the very high temperature reactor (VHTR) because tritium is easily permeated through high temperature metallic surfaces. Tritium permeations in the VHTR-integrated systems were investigated in this study using the tritium permeation analysis code (TPAC) that was developed by Idaho National Laboratory (INL). The INL TPAC is a numerical tool that is based on the mass balance equations of tritium containing species and hydrogen (i.e. HT, H2, HTO, HTSO4, TI) coupled with a variety of tritium sources, sink, and permeation models. In the TPAC, ternary fission and thermal neutron caption reactions with 6Li, 7Li 10B, 3He were taken into considerations as tritium sources. Purification and leakage models were implemented as main tritium sinks. Permeation of tritium and H2 through pipes, vessels, and heat exchangers were considered as main tritium transport paths. In addition, electroyzer and isotope exchange models were developed for analyzing hydrogen production systems including high temperature electrolysis (HTSE) and sulfur-iodine processes.

42 ENGINEERING↗

Updated OpenStudio (OS) Small Office Prototype Model

The U.S. Department of Energy (DOE) supports the development of commercial building energy codes and standards by participating in industry review, update processes, and providing technical analyses to support both published model codes and potential changes. DOE publishes its findings to ensure transparency in its support, and to make its analysis available for both public review and use. In conjunction with this effort, DOE’s flagship building energy model (BEM) tools consist of the open-source EnergyPlus simulation engine and OpenStudio. These tools allow a user to modify a building, estimate energy use, and new releases are typically downloaded by over 20,000 users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Manual and User's Guide for MILDOS, Version 4.1

The MILDOS computer code is used to estimate the radiological impacts of airborne emissions from uranium mining and milling facilities. The code allows users to consider both conventional uranium ore operations and operations associated with in situ recovery (ISR) facilities. The code is used by license applicants and U.S. Nuclear Regulatory Commission staff to perform routine radiological impact and compliance evaluations for various uranium recovery operations. As part of a major code update, the following improvements and additions were made to the code: (a) revised ISR models, (b) support for ores containing thorium-232 (Th-232) and its daughter radionuclides in addition to the currently supported uranium-238 (U-238) and its daughter radionuclides, (c) a revised area source model, (d) the capability to perform sensitivity analysis on specific input parameters, (e) the capability to use current meteorological data provided by the National Climatic Data Center, and (f) an interactive results module.

54 ENVIRONMENTAL SCIENCES↗

Upgrade of the PNNL TEPC and Multisphere Spectrometer

The Pacific Northwest National Laboratory (PNNL) has used two types of instruments, the tissue equivalent proportional counter (TEPC) and the multisphere spectrometer for characterizing neutron radiation fields in support of neutron dosimetry at the Hanford site. The US Department of Energy recently issued new requirements for radiation protection standards in 10 CFR 835 which affect the way that neutron dose equivalent rates are evaluated. In response to the new requirements, PNNL has upgraded the analyses used in conjunction with the TEPC and multisphere. The analysis software for the TEPC was modified for this effort, and a new analysis code was selected for the multisphere. These new analysis techniques were implemented and tested with measurement data that had been collected in previous measurements. In order to test the effectiveness of the changes, measurements were taken in PNNL’s Low Scatter Room using 252Cf sources in both unmoderated and D2O-moderated configurations that generate well-characterized neutron fields. The instruments were also used at Los Alamos National Laboratory (LANL), in their Neutron Free-in-Air calibration room, also using neutron sources that generate well-characterized neutron fields. The results of the software modifications and the measurements are documented in this report. The TEPC measurements performed at PNNL agreed well with accepted dose equivalent rates using the traditional analysis, agreeing with the accepted value to within 13% for both unmoderated and moderated 252Cf sources. When the new analysis was applied to the TEPC measurement data, the results were high compared to the new accepted value. A similar pattern was seen for TEPC measurements at LANL. Using the traditional analysis method, results for all neutron sources showed good agreement with accepted values, nearly always less than 10%. For the new method of analysis, however, the TEPC responded with higher dose equivalent rates than accepted, by as much as 25%. The reason for the overresponse is that there is very little attenuation of the neutrons by tissue, so it cannot match the effect of attenuation by 1 cm of tissue called for in the new standards. This could be corrected with a modified instrument with a thicker wall, or by analytical means that would need to be developed. The multisphere spectrometer performed reasonably well both at PNNL and at LANL. It could produce a neutron spectrum that was similar to the accepted spectrum, and total flux values were usually within 15% of the accepted values. Dose equivalent rates were usually within 18% of the accepted values. The average energies, however, were usually lower than the accepted values. The performance of this instrument could be much better than seen in this study. If PNNL were to add some moderating spheres to its measurement set and calculate a new set of instrument response functions, performance could be improved. The multisphere could then be a more useful instrument for assessing the dose equivalent rate in the workplace.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HTTR Fuel Block Simulations with SCALE

The SCALE code system is currently being updated to improve the methods and data to support High Temperature Gas Cooled reactor analysis. This paper presents the results of a High Temperature Engineering Test Reactor (HTTR) fuel block analysis with SCALE6.0, which is included as one of the sources of validation data. Good agreement is reported between continuous energy and multigroup SCALE/KENO models of the HTTR block for eigenvalue and fission density distribution. The agreement of the SCALE/KENO results with the MCNP5 results is also very good. The boundary condition is shown to have a large effect on both the calculated eigenvalue and the fission density distribution within the fuel block. In addition to the reported results, a method is proposed to alleviate the fuel mass non-conservation due to the clipping of the lattice of grains within the fuel element in the Monte Carlo continuous energy models. One of the high-temperature gas-cooled (HTGR) reactor technology options under consideration by the Next Generation Nuclear Plant (NGNP) project is based on the prismatic, graphite-moderated reactor design. Within this context, the capability to generate accurate three-dimensional (3-D) core power distributions is one of the main challenges for the NGNP methods development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗