Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Endocavitary in vivo Dosimetry for IMRT Treatments of Gynecologic Tumors

The accuracy and reproducibility of endometrial carcinoma treatment with intensity-modulated radiotherapy (IMRT) was assessed by means of in vivo dosimetry. Six patients who had previously undergone radical hysterectomy for endometrial carcinoma were treated with IMRT using a vaginal applicator with radio-opaque fiducial markers. An ion-chamber inserted into the applicator supplied an endocavitary in vivo dosimetry for quality assurance purposes. The ratio R = D/D{sub TPS} between the in vivo measured dose D and the predicted dose by the treatment planning system D{sub TPS} was determined for every fraction of the treatment. Results showed that 90% and 100% of the ratios resulted equal to 1 within 5% and 10%, respectively. The mean value of the ratios distribution for the 6 patients was R = 0.995 and the SD = 0.034. The ratio R* between the measured and predicted total doses for each patient was near to 1, within 2%. The dosimetric results suggest that the use of a vaginal applicator in an image-guided approach could make the interfractions target position stable and reproducible, allowing a safe use of the IMRT technique in the treatment of postoperative vaginal vault. In vivo dosimetry may supply useful information about the discrimination of random vs. systematic errors. The workload is minimum and this in vivo dosimetry can be applied also in the clinical routine.

61 RADIATION PROTECTION AND DOSIMETRY↗

Couch height–based patient setup for abdominal radiation therapy

There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiple-scattering Corrections to Measurements of the Prompt Fission Neutron Spectrum

The Chi-Nu project, conducted jointly by LANL and LLNL, aims to measure the shape of the prompt fission neutron spectrum (PFNS) for fission of {sup 239}Pu induced by neutrons from 50 keV to 15 MeV with accuracies of 3–5% in the outgoing energy from 50 keV to 9 MeV and 15% from 9 to 15 MeV. In order to meet this goal, detailed Monte Carlo simulations are being used to assess the importance and effect of every component in the experimental configuration. As part of this effort, we have also simulated some past PFNS measurements to identify possible sources of systematic error. We find that multiple scattering plays an important role in the target geometry, collimators, and detector response and that past experiments probably underestimated the extent of this effect.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Implementation of a Super Mirror Polarizer at the SNS Fundamental Neutron Physics Beamline

A new bender supermirror polarizer is used to polarize the cold neutron beam at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source. We present the design of a compensation magnet that was built around the polarizer to minimize the polarizer fringe fields that could compromise the magnetic field requirements of the NPDGamma experiment for the field uniformity in the spin rotator and the field direction in the liquid hydrogen target located downstream from the polarizer. The entire magnetic field environment of the experiment has been analyzed using a finite-element model. Measurements of the magnetic field gradients and field direction have been carried out and the results are less than the upper limits required in the experiment. According to the results the compensated fields meet the stringent magnetic field requirements of the experiment defined by the systematic errors that have to be well below the statistical uncertainty of 10 8 in our main observable, the gamma asymmetry in neutron capture on hydrogen. We describe the design of the magnetic field, the construction of the compensation magnet, and we compare results of the field measurements with the results from the model.

Balascuta, S.↗

Refining instrument response functions with 3-D Monte Carlo simulations of differential hard x-ray spectrometers

Three x-ray spectrometers – the hard x-ray detector (HXRD), the bremsstrahlung MeV x-ray spectrometer (BMXS), and the hard x-ray image plate (HXIP) – areused here to estimate hot-electron bremsstrahlung spectrum parameters for inertial confinement fusion experiments on OMEGA. Using 1-D deterministically calculated response functions, they show significantly different estimates of spectrum slope temperature. For all three detectors, 3-D Geant4 Monte Carlo simulations are developed and used to compute instrument response functions. Simulations explain features in raw image-plate data, but only significantly improve systematic errors in predicted detector channel signals for BMXS and do not entirely eliminate the discrepancy between estimates of slope temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asymmetric errors

We present a procedure for handling asymmetric errors. Many results in particle physics are presented as values with different positive and negative errors, and there is no consistent procedure for handling them. We consider the difference between errors quoted, using pdfs and using likelihoods, and the difference between the rms spread of a measurement and the 68% central confidence region. We provide a comprehensive analysis of the possibilities, and software tools to enable their use.

Asymmetric↗

Measurement of the Top Quark Mass in the Lepton+Jets Channel Using the Lepton Transverse Momentum

This letter reports a measurement of the top quark mass, M{sub top}, in data from p{bar p} collisions at {radical}s = 1.96 TeV corresponding to 2.7 fb{sup -1} of integrated luminosity at the Fermilab Tevatron using the CDF II detector. Events with the lepton+jets topology are selected. An unbinned likelihood is constructed based on the dependence of the lepton transverse momentum, P{sub T}, on M{sub top}. A maximum likelihood fit to the data yields a measured mass M{sub top} = 176.9 {+-} 8.0{sub stat} {+-} 2.7{sub syst} GeV/c{sup 2}. In this measurement, the contribution by the jet energy scale uncertainty to the systematic error is negligible. The result provides an important consistency test for other M{sub top} measurements where explicit use of the jet energy is made for deriving the top quark mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Harmonizing solar induced fluorescence across spatial scales, instruments, and extraction methods using proximal and airborne remote sensing: A multi-scale study in a soybean field

Solar-induced chlorophyll fluorescence (SIF) has been widely used to track vegetation photosynthesis at different scales ranging from in-situ measurements to satellite products. Airborne platforms sample SIF data at a spatial scale intermediate between in-situ and satellite, matching that of ground measurement (e.g. flux tower footprints and other field sampling), enabling us to explore causes of SIF variation and validate satellite-based SIF products. However, harmonizing SIF across sensors and platforms (correcting for systematic errors to yield a consistent, comparable SIF product) is challenging because SIF can be retrieved in different absorption windows, with different instruments and methods complicating the comparison between different observational levels (i.e., ground, airborne, satellites) and between sites equipped with different instruments with varying optical properties (spectral resolution and sampling intervals, spatial resolution). Additionally, the spatial and temporal variability of atmospheric properties can influence the retrieval of the weak SIF signal. Because of these complications, direct comparisons of airborne and ground SIF across scales are rarely attempted. Here, in this study, we combined airborne SIF data with simultaneous ‘ground truth’ data collected by stationary and mobile platforms in a soybean field in Nebraska, USA. In this effort, we tested several SIF extraction methods, including Fraunhofer Line Discrimination (FLD), improved Fraunhofer Line Discrimination (iFLD), Spectral Fitting Method (SFM), SpecFit, and a Singular Vector Decomposition (SVD) method. The SpecFit method was sensitive to the 715–740 nm water bands and removing the water bands in the fitting process yielded better agreement between the airborne and ground SIF spectra. Accurate estimation of the ground level downwelling irradiance obtained by ground measurements over a calibration target improved agreement between airborne and ground SIF retrievals at the O 2 A band, and allowed us to derive a SIF dataset with improved agreement across platforms and sampling scales. This experimental approach provided a method for generating comparable SIF signals across instruments, methods and platforms, which is critical to understanding the SIF-GPP relationship at different scales and to cross-validate the diversity of platforms used for satellite products calibration and validation.

54 ENVIRONMENTAL SCIENCES↗

Preliminary survey on site-adaptation techniques for satellite-derived and reanalysis solar radiation datasets

At any site, the bankability of a projected solar power plant largely depends on the accuracy and general quality of the solar radiation data generated during the solar resource assessment phase. The term 'site adaptation' has recently started to be used in the framework of solar energy projects to refer to the improvement that can be achieved in satellite-derived solar irradiance and model data when short-term local ground measurements are used to correct systematic errors and bias in the original dataset. This contribution presents a preliminary survey of different possible techniques that can improve long-term satellite-derived and model-derived solar radiation data through the use of short-term on-site ground measurements. The possible approaches that are reported here may be applied in different ways, depending on the origin and characteristics of the uncertainties in the modeled data. This work, which is the first step of a forthcoming in-depth assessment of methodologies for site adaptation, has been done within the framework of the International Energy Agency Solar Heating and Cooling Programme Task 46 'Solar Resource Assessment and Forecasting.'

14 SOLAR ENERGY↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Integrated Post-Experiment Monoisotopic Mass Refinement: An Integrated Approach to Accurately Assign Monoisotopic Precursor Masses to Tandem Mass Spectrometric Data

Accurate assignment of monoisotopic precursor masses to tandem mass spectrometric (MS/MS) data is a fundamental and critically important step for successful peptide identifications in mass spectrometry based proteomics. Here we describe an integrated approach that combines three previously reported methods of treating MS/MS data for precursor mass refinement. This combined method, “integrated Post-Experiment Monoisotopic Mass Refinement” (iPE MMR), integrates steps: 1) generation of refined MS/MS data by DeconMSn, 2) additional refinement of the resultant MS/MS data by a modified version of PE-MMR, and 3) elimination of systematic errors of precursor masses using DtaRefinery. iPE-MMR is the first method that utilizes all MS information from multiple MS scans of a precursor ion and multiple charge states of it in an MS scan to determine precursor mass. By combining the synergistic features of each of method, iPE MMR increases sensitivity in peptide identification and provides increased accuracy when applied to complex high-throughput proteomics data. iPE MMR also allows incorporating additional data processing step(s) or skipping step(s), if necessary, to enable new developments or applications of the tools, as each step of iPE MMR produces output data in a common and conventional format used in proteomics data processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

malbacR: A Package for Standardized Implementation of Batch Correction Methods for Omics Data

Mass spectrometry is a powerful tool for identifying and analyzing small molecules, such as metabolites and lipids, in com-plex biological samples. Liquid chromatography and gas chromatography mass spectrometry studies quite commonly in-volve large numbers of samples, which can require significant time for sample preparation and analyses. To accommodate such studies, the samples are commonly split into batches. Inevitably, variations in sample handling, temperature fluctua-tion, imprecise timing, column degradation and other factors result in systematic errors or biases of the measured abundances between the batches. Numerous methods are available via R packages to assist with batch correction for small molecule om-ics data; however, since these methods were developed by different research teams, the algorithms are available in separate R packages, each with different data input and output formats. We introduce the malbacR package which consolidates eleven common batch effect correction methods for small molecule omics data into one place so users can easily implement and compare: pareto scaling, power scaling, range scaling, ComBat, EigenMS, NOMIS, RUV-random, QC-RLSC, WaveI-CA2.0, TIGER, and SERRF. The malbacR package standardizes data input and output formats across these batch correction methods. The package works in conjunction with the pmartR package, allowing users to seamlessly include batch effect cor-rection in a pmartR workflow without needing any additional data manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Free Energies of Proton-Coupled Electron Transfer Reagents and Their Applications

Here, we present an update and revision to our 2010 review on the topic of proton- coupled electron transfer (PCET) reagent thermochemistry. Over the past decade, the data and thermochemical formalisms presented in that review have been of value to multiple fields. Concurrently, there have been advances in the thermochemical cycles and experimental methods used to measure these values. This Review (i) summarizes those advancements, (ii) corrects systematic errors in our prior review that shifted many of the absolute values in the tabulated data, (iii) provides updated tables of thermochemical values, and (iv) discusses new conclusions and opportunities from the assembled data and associated techniques. We advocate for updated thermochemical cycles that provide greater clarity and reduce experimental barriers to the calculation and measurement of Gibbs free energies for the conversion of X to XHn in PCET reactions. In particular, we demonstrate the utility and generality of reporting potentials of hydrogenation, E°(V vs H 2 ), in almost any solvent and how these values are connected to more widely reported bond dissociation free energies (BDFEs). The tabulated data demonstrate that E°(V vs H 2 ) and BDFEs are generally insensitive to the nature of the solvent and, in some cases, even to the phase (gas versus solution). This Review also presents introductions to several emerging fields in PCET thermochemistry to give readers windows into the diversity of research being performed. Some of the next frontiers in this rapidly growing field are coordination-induced bond weakening, PCET in novel solvent environments, and reactions at material interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Charge Equilibration Methods To Generate Electrostatic Fields in Nanoporous Materials

Charge equilibration (Qeq) methods can estimate the electrostatic potential of molecules and periodic frameworks by assigning point charges to each atom, using only a small fraction of the resources needed to compute density functional (DFT)-derived charges. This makes possible, for example, the computational screening of thousands of microporous structures to assess their performance for the adsorption of polar molecules. Recently, different variants of the original Qeq scheme were proposed to improve the quality of the computed point charges. One focus of this research was to improve the gas adsorption predictions in metal-organic frameworks (MOFs), for which many different structures are available. In this work, we review the evolution of the method from the original Qeq scheme, understanding the role of the different modifications on the final output. We evaluated the result of combining different protocols and set of parameters, by comparing the Qeq charges with high quality DFT-derived DDEC charges for 2338 MOF structures. We focused on the systematic errors that are attributable to specific atom types to quantify the final precision that one can expect from Qeq methods in the context of gas adsorption where the electrostatic potential plays a significant role, namely, CO 2 and H 2 S adsorption. In conclusion, both the type of algorithm and the input parameters have a large impact on the resulting charges, and we draw some guidelines to help the user to choose the proper combination of the two for obtaining a meaningful set of charges. We show that, considering this set of MOFs, the accuracy of the original Qeq scheme is often still comparable with the most recent variants, even if it clearly fails in the presence of certain atom types, such as alkali metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polyethylene in Dead-End Silica Nanopores: Forces and Mobility from Non-Equilibrium Statistical Mechanics and Exchange Spectroscopy Nuclear Magnetic Resonance

Billions of tons of plastic have been produced, and only a small fraction of this has been recycled. Tennakoon et al. [Nature Catalysis 3, 893 (2020)] developed a catalyst that repeatedly cleaves C 10 –C 30 hydrocarbons from the end of a polyethylene chain. The reaction occurs at a Pt nanoparticle at the base of a cylindrical silica mesopore with a diameter of 2 nm and a length of 110 nm. Portions of the polymer situated inside the pore can be differentiated from those outside using 13 C nuclear magnetic resonance (NMR), allowing the dynamics and extent of polymer threading to be monitored using two-dimensional (2D) exchange spectroscopy NMR. Here we construct a Fokker–Planck equation for the polymer dynamics by assuming a reptation diffusivity and a graduated adsorption free energy that depends linearly on the depth of polymer penetration in the pore. The solutions allow us to predict the intensities of the 2D NMR resonances as a function of time. We use the solutions to extract a polymer diffusivity at each temperature and estimate the per-segment desorption free energy, enthalpy, and entropy. Random and systematic errors are examined to test key assumptions in the theory and interpretation of the experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

“Super-parameterization”: A better way to simulate regional extreme precipitation?

Extreme precipitation is generally underestimated by current climate models relative to observations of present-day rainfall distributions. Possible causes of this systematic error include the convective parameterization in these models that have been designed to reproduce measurements of climatological mean precipitation. One possible approach to improve the interaction of subgrid-scale physical processes and large-scale climate is to replace the conventional convective parameterizations with a high-resolution cloud-system resolving model. A "super-parameterized" Community Atmosphere Model (SP-CAM) utilizing this approach is used in this study to investigate the distribution of extreme precipitation in the United States. Results show that SP-CAM better simulates the distributions of both light and intense precipitation compared to the standard version of CAM based upon conventional parameterizations. The improvements are mostly seen in regions dominated by convective precipitation, suggesting that super-parameterization provides a better representation of subgrid convective processes.

54 ENVIRONMENTAL SCIENCES↗