Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The MAXEBIS at GSI as a test ion source for charge breeding and for HITRAP

The electron beam ion source MAXEBIS, developed and built at the University of Frankfurt, has been installed at GSI to serve as an offline test ion source for the HITRAP project and for use as a test setup for charge breeding explorations. The setup has been equipped with new diagnostics and beam optics devices. Two ion sources dedicated to the production of singly charged ions for external ion injection into the MAXEBIS have been included. First time of flight (TOF) spectra with external injected, charge-bred argon ions were taken. However, these spectra indicated beam losses in the beam transport from the multipassage spectrometer (MPS) to the MAXEBIS. In order to understand the losses, the beam transport has been simulated with the SIMION code and the beam line has been modified accordingly. Measurements of the MAXEBIS' beam emittance, using the ''nondestructive'' beam profile method, have been performed as well as measurements of the electron current density via charge state analysis of the TOF spectra. The injection and breeding efficiency of the MAXEBIS have been determined for the first time. The results of the measurements and the planned experiments will be discussed.

43 PARTICLE ACCELERATORS↗

Production of Secondary Radioactive Beams of He and Li Neutron-Rich Isotopes in the Fragmentation Reaction {sup 15}N(47 MeV/A)+{sup 9}Be

Yields of neutron-rich isotopes of He and Li produced in the reaction {sup 15}N(47 MeV/A)+{sup 9}Be have been measured. The experiment was carried out at the fragment separator COMBAS of the Flerov Laboratory of Nuclear Reactions, JINR (Dubna). Ion beams accelerated with the U-400M cyclotron and thick target were used. The products were identified according to their magnetic rigidities and time of flight (TOF) via the separator. The path length of TOF was 7,5 m. As a result of fragmentation, beams of four isotopes of Lithium and two isotopes of Helium were obtained. The inclusive velocities of reaction products were obtained and isotopes yields were calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LATERAL HEAT FLOW INFRARED THERMOGRAPHY FOR THICKNESS INDEPENDENT DETERMINATION OF THERMAL DIFFUSIVITY IN CFRP

In conventional infrared thermography, determination of thermal diffusivity requires thickness information. Recently GE has been experimenting with the use of lateral heat flow to determine thermal diffusivity without thickness information. This work builds on previous work at NASA Langley and Wayne State University but we incorporate thermal time of flight (tof) analysis rather than curve fitting to obtain quantitative information. We have developed appropriate theoretical models and a tof based data analysis framework to experimentally determine all components of thermal diffusivity from the time-temperature measurements. Initial validation was carried out using finite difference simulations. Experimental validation was done using anisotropic carbon fiber reinforced polymer (CFRP) composites. We found that in the CFRP samples used, the in-plane component of diffusivity is about eight times larger than the through-thickness component.

36 MATERIALS SCIENCE↗

Measurement of DT and DD components in neutron spectrum with a double-crystal time-of-flight spectrometer

To investigate the deuteron and triton density ratio in core plasmas, a new methodology with measurement of tritium (DT) and deuterium (DD) neutron count rate ratio using a double-crystal time-of-flight (TOF) spectrometer is proposed. Multi-discriminator electronic circuits for the first and second detectors are used in addition to the TOF technique. The optimum arrangement of the detectors and discrimination window were examined considering the relations between the geometrical arrangement and deposited energy using a Monte Carlo Code, PHITS (Particle and Heavy Ion Transport Code System). An experiment to verify the calculations was performed using DD neutrons from an accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Multichannel Time-of-Flight Technique for Plasma Potential Profile Measurements by Heavy Ion Beam Diagnostic on the Tokamak ISTTOK

This contribution summarizes the current implementation of the time-of-flight (TOF) energy analysis for plasma potential measurements by the heavy ion beam diagnostic (HIBD) on the tokamak ISTTOK. The technique is described in detail. The results of the measurements of the ISTTOK plasma potential radial profile are presented. It is proved that the TOF energy analysis is suitable for simultaneous multichannel detection using a multiple cell array detector. With the aim of improving the signal-to-noise ratio of the diagnostic, the channeltrons have recently been installed on the 'start' and 'stop' detectors and preliminary results are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A photoelectron-photoion coincidence imaging apparatus for femtosecond time-resolved molecular dynamics with electron time-of-flight resolution of {sigma}=18 ps and energy resolution {delta}E/E=3.5%

We report on the construction and performance of a novel photoelectron-photoion coincidence machine in our laboratory in Amsterdam to measure the full three-dimensional momentum distribution of correlated electrons and ions in femtosecond time-resolved molecular beam experiments. We implemented sets of open electron and ion lenses to time stretch and velocity map the charged particles. Time switched voltages are operated on the particle lenses to enable optimal electric field strengths for velocity map focusing conditions of electrons and ions separately. The position and time sensitive detectors employ microchannel plates (MCPs) in front of delay line detectors. A special effort was made to obtain the time-of-flight (TOF) of the electrons at high temporal resolution using small pore (5 {mu}m) MCPs and implementing fast timing electronics. We measured the TOF distribution of the electrons under our typical coincidence field strengths with a temporal resolution down to {sigma}=18 ps. We observed that our electron coincidence detector has a timing resolution better than {sigma}=16 ps, which is mainly determined by the residual transit time spread of the MCPs. The typical electron energy resolution appears to be nearly laser bandwidth limited with a relative resolution of {delta}E{sub FWHM}/E=3.5% for electrons with kinetic energy near 2 eV. The mass resolution of the ion detector for ions measured in coincidence with electrons is about {delta}m{sub FWHM}/m=1/4150. The velocity map focusing of our extended source volume of particles, due to the overlap of the molecular beam with the laser beams, results in a parent ion spot on our detector focused down to {sigma}=115 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Explosive Boiling In Carbon Target Irradiated By Third Harmonic Of Nd :YAG Laser

In order to identify the physical phenomena responsible to the formation of droplets onto thin films grown during laser ablation, and to correlate between the appearance of those droplets versus the laser flux, we have measured the amount of ejected matter for carbon target irradiated by a third harmonic of Nd:YAG laser by changing laser flux. The measurement was achieved by a quartz microbalance placed in front of the target. The obtained results show at first a linear increase of the ejected material followed by a saturation behavior, and then an abrupt increase of the ablated mass beyond a laser Intensity of 3,64x10{sup 10} W/cm{sup 2}. This increasing is assigned to the homogeneous nucleation of bubbles in a layer of the molten material, also called phase explosion, the surface temperature of the target will approaches the critical thermodynamic temperature (T{sub tc}). We have also measured time-of-flight (TOF) distributions of positives ions of carbons in the plasma using a charge collector. The TOF signals have been fitted with a shifted Maxwellian distribution function. This has allowed us to estimate the critical temperature T{sub tc} of the material.

36 MATERIALS SCIENCE↗

Laser-induced desorption of organic molecules from front- and back-irradiated metal foils

Laser-Induced Acoustic Desorption (LIAD) from thin metal foils is a promising technique for gentle and efficient volatilization of intact organic molecules from surfaces of solid substrates. Using the Single Photon Ionization (SPI) method combined with time-of-flight mass-spectrometry (TOF MS), desorbed flux in LIAD was examined and compared to that from direct laser desorption (LD). Molecules of various organic dyes were used in experiments. Translational velocities of the desorbed intact molecules did not depend on the desorbing laser intensity, which implies the presence of more sophisticated mechanism of energy transfer than the direct mechanical or thermal coupling between the laser pulse and the adsorbed molecules. The results of our experiments indicate that the LIAD phenomenon cannot be described in terms of a simple mechanical shake-off nor the direct laser desorption. Rather, they suggest that multi-step energy transfer processes are involved. Possible qualitative mechanism of LIAD that are based on formation of non-equilibrium energy states in the adsorbate-substrate system are proposed and discussed.

36 MATERIALS SCIENCE↗

Quantitative Determination of Deuterium Atom Concentration in Zinc Oxide Thin Films by Time-of-Flight Secondary Ion Mass Spectrometry

ZnO is a wide-gap semiconductor with very interesting electronic properties.[1,2] Therefore, it has been extensively studied for many years. It has been found that even low centrations of hydrogen in ZnO film can considerably change its electronic behavior.[3-5] Quite a few papers have discussed this issue but it has not been fully understood. Lack of experimental data, especially quantitative data on hydrogen concentration in ZnO samples is an important reason. Dynamic SIMS is the best technique to determine concentration of hydrogen atoms in materials.[6-9] However, it is a very specific technique and the entation is mostly available in semiconductor industry. ToF-SIMS is a more versatile instrument and it is more available in universities and research institutes. Background hydrogen interference has been known to be a serious problem in quantifying hydrogen atoms in solid samples. Although SIMS is an ultra-high vacuum (UHV) technique, there are still some residual gases existing in vacuum chambers during analysis. Most of them are H2, H2O or CH4, which lead to a background that greatly interferes quantitative detection of hydrogen. Therefore, deuterium atoms have been intentionally introduced into the system to avoid this problem. Standard samples are very important for SIMS quantitative analysis. A common method to prepare such kind of standard samples is ion-implanting. Therefore, a set of standard D-ZnO samples were prepared by ion-implanting in our work. In this paper, we report using ToF-SIMS to quantitatively determine the concentration of deuterium atoms in a number of high-quality epitaxial ZnO films, with a set of standard samples as references. We are especially interested in the detection limit of deuterium concentration in ZnO. In addition, hydrogen background interference was also investigated.

08 HYDROGEN↗

High-resolution reflecting time-of-flight momentum and energy mapping system

A new system to map electron momentum and energy is proposed. A reflecting electrode is introduced into a time-of-flight (TOF) system whose decelerating electric field sends all the electrons back to a position-sensitive detector close to but behind the source of the electrons. The longer flying distance that results makes it possible to significantly improve the energy-resolved performance, especially in the higher energy region. The dependence of the new TOF system on its characteristic parameters is analyzed, along with its application to attosecond streak cameras. Experimental results verified a relative energy resolution better than 0.2 eV for 22 eV electrons and also revealed the availability of the improved relative energy resolution smaller than 1.0% for electron energy ranging from 30 to 40 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DSP Algorithms for Fission Fragment and Prompt Fission Neutron Spectroscopy

Digital signal processing (DSP) algorithms are in high demand for modern nuclear fission investigation due to importance of increase the accuracy of fissile nuclear data for new generation of nuclear power stations. DSP algorithms for fission fragment (FF) and prompt fission neutron (PFN) spectroscopy are described in the present work. The twin Frisch-grid ionization chamber (GTIC) is used to measure the kinetic energy-, mass- and angular distributions of the FF in the {sup 252}Cf(SF) reaction. Along with the neutron time-of-flight (TOF) measurement the correlation between neutron emission and FF mass and energy is investigated. The TOF is measured between common cathode of the GTIC and the neutron detector (ND) pulses. Waveform digitizers (WFD) having 12 bit amplitude resolution and 100 MHz sampling frequency are used for the detector pulse sampling. DSP algorithms are developed as recursive procedures to perform the signal processing, similar to those available in various nuclear electronics modules, such as constant fraction discriminator (CFD), pulse shape discriminator (PSD), peak-sensitive analogue-to-digital converter (pADC) and pulse shaping amplifier (PSA). To measure the angle between FF and the cathode plane normal to the GTIC a new algorithm is developed having advantage over the traditional analogue pulse processing schemes. Algorithms are tested by comparing the numerical simulation of the data analysis of the {sup 252}Cf(SF) reaction with data available from literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The photodissociation of oxetane at 193 nm as the reverse of the Paterno-Buchi reaction

We investigated the photodissociation of oxetane (1,3-trimethylene oxide) at 193.3 nm in a molecular-beam apparatus using photofragment-translational spectroscopy and selective photoionization. We measured time-of-flight (TOF) spectra and angular anisotropy parameters {beta}(t) as a function of flight time of products at m/z=26-30 u utilizing photoionization energies from 9.8 to 14.8 eV. The TOF distributions of the products alter greatly with the employed photon energy, whereas their {beta}(t) distributions are insensitive to the photon energy. Dissociation to H{sub 2}CO+C{sub 2}H{sub 4} is the major channel in the title reaction. Three distinct dissociation paths with branching ratios 0.923:0.058:0.019 are responsible for the three features observed in the distribution of kinetic energy released in the channel H{sub 2}CO+C{sub 2}H{sub 4}. The observation of H{sub 2} and H atoms, {approx}1% in branching, indicates that products H{sub 2}CO and C{sub 2}H{sub 4} spontaneously decompose to only a small extent. Most HCO, C{sub 2}H{sub 3}, and C{sub 2}H{sub 2} ions originate from dissociative photoionization of products H{sub 2}CO and C{sub 2}H{sub 4}. Except atomic H and H{sub 2}, the photoproducts have large angular anisotropies, {beta}{>=}-0.8, which reflects rapid dissociation of oxetane following optical excitation at 193.3 nm. The mechanisms of dissociation of oxetane are addressed. Our results confirm the quantum-chemical calculations of Palmer et al. and provide profound insight into the Paterno-Buchi reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 {mu}s. Accordingly, the sample is under excitation in 10{sup -4} part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 10{sup 10} V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and optical properties of dilute InAsN grown by molecular beam epitaxy

We perform a structural and optical characterization of InAs{sub 1-x}N{sub x} epilayers grown by molecular beam epitaxy on InAs substrates (x < or approx. 2.2%). High-resolution x-ray diffraction (HRXRD) is used to obtain information about the crystal quality and the strain state of the samples and to determine the N content of the films. The composition of two of the samples investigated is also obtained with time-of-flight secondary ion mass spectroscopy (ToF-SIMS) measurements. The combined analysis of the HRXRD and ToF-SIMS data suggests that the lattice parameter of InAsN might significantly deviate from Vegard's law. Raman scattering and far-infrared reflectivity measurements have been carried out to investigate the incorporation of N into the InAsN alloy. N-related local vibrational modes are detected in the samples with higher N content. The origin of the observed features is discussed. We study the compositional dependence of the room-temperature band gap energy of the InAsN alloy. For this purpose, photoluminescence and optical absorption measurements are presented. The results are analyzed in terms of the band-anticrossing (BAC) model. We find that the room-temperature coupling parameter for InAsN within the BAC model is C{sub NM}=2.0{+-}0.1 eV.

36 MATERIALS SCIENCE↗

Synthesis of Endohedral Fullerene Using ECR Ion Source

We are developing an ECRIS apparatus which is designed for the production of endohedral fullerenes. Our promising approaches to produce the endohedral fullerenes using the ECRIS are the ion-ion collision reaction of fullerenes and the other atom in their mixture plasma and simple ion implantation of atom into fullerene layer. In this study, we tried to synthesize the endohedral nitrogen-fullerenes by ion implantation. N{sup +} beam was irradiated to a fullerene target with a specific energy and dose. As a result, we could observe the peak of N+C{sub 60} from targets after N{sup +} beam irradiation with TOF-SIMS and LDI-TOF-MS.

36 MATERIALS SCIENCE↗

Full characterization of laser-accelerated ion beams using Faraday cup, silicon carbide, and single-crystal diamond detectors

Multi-MeV beams of light ions have been produced using the 300 picosecond, kJ-class iodine laser, operating at the Prague Asterix Laser System facility in Prague. Real-time ion diagnostics have been performed by the use of various time-of-flight (TOF) detectors: ion collectors (ICs) with and without absorber thin films, new prototypes of single-crystal diamond and silicon carbide detectors, and an electrostatic ion mass spectrometer (IEA). In order to suppress the long photopeak induced by soft X-rays and to avoid the overlap with the signal from ultrafast particles, the ICs have been shielded with Al foil filters. The application of large-bandgap semiconductor detectors (>3 eV) ensured cutting of the plasma-emitted visible and soft-UV radiation and enhancing the sensitivity to the very fast proton/ion beams. Employing the IEA spectrometer, various ion species and charge states in the expanding laser-plasma have been determined. Processing of the experimental data based on the TOF technique, including estimation of the plasma fast proton maximum and peak energy, ion beam currents and total charge, total number of fast protons, as well as deconvolution processes, ion stopping power, and ion/photon transmission calculations for the different metallic filters used, are reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Work Functions, Metallicity, Band Bending, Interfacial Dipoles by EUPS for Characterizing High-k/Metal Interfaces

EUPS (EUV excited photoelectron spectroscopy) is a novel photoelectron spectroscopy technique, in which a sample is excited with 4.86 nm (255 eV), 3-ns pulse EUV light emitted from a laser-produced plasma and the resulting electron spectrum is analyzed with a time-of-flight (TOF) analyzer. EUPS gives information of the topmost atoms because the escape depth of photo-electrons excited by 4.86 nm light is only 0.5 nm. EUPS can evaluate band-bending because the peak density of the excitation light on the sample is extremely high, so that bent electronic bands in semiconductors can be flattened. Secondary electron spectra, from which the vacuum level of the material surface can be determined, are obtained very quickly owing to the use of a TOF analyzer, The metal gate related issues are one of the most challenging topics facing CMOS technology. This paper demonstrates EUPS as a powerful method for characterizing high-k/metal interfaces by showing data from direct observations of interfacial dipoles.

36 MATERIALS SCIENCE↗

Monoenergetic proton emission from nuclear reaction induced by high intensity laser-generated plasma

A 10{sup 16} W/cm{sup 2} Asterix laser pulse intensity, 1315 nm at the fundamental frequency, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD{sub 2} targets placed inside a high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deutons and carbon ions emission with energy of up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deutons may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD{sub 2} targets can be employed to be irradiated by the plasma-accelerated deutons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗