Search NASA⌕ Search

SEARCH · Search NASA

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Stellar Neutrino Emission across the Mass–Metallicity Plane

We explore neutrino emission from nonrotating, single-star models across six initial metallicities and 70 initial masses from the zero-age main sequence to the final fate. Overall, across the mass spectrum, we find metal-poor stellar models tend to have denser, hotter, and more massive cores with lower envelope opacities, larger surface luminosities, and larger effective temperatures than their metal-rich counterparts. Across the mass–metallicity plane we identify the sequence (initial CNO → 14 N → 22 Ne → 25 Mg → 26 Al → 26 Mg → 30 P → 30 Si) as making primary contributions to the neutrino luminosity at different phases of evolution. For the low-mass models we find neutrino emission from the nitrogen flash and thermal pulse phases of evolution depend strongly on the initial metallicity. For the high-mass models, neutrino emission at He-core ignition and He-shell burning depends strongly on the initial metallicity. Antineutrino emission during C, Ne, and O burning shows a strong metallicity dependence with 22 Ne(α, n) 25 Mg providing much of the neutron excess available for inverse-β decays. We integrate the stellar tracks over an initial mass function and time to investigate the neutrino emission from a simple stellar population. We find average neutrino emission from simple stellar populations to be 0.5–1.2 MeV electron neutrinos. Lower metallicity stellar populations produce slightly larger neutrino luminosities and average β decay energies. This study can provide targets for neutrino detectors from individual stars and stellar populations. We provide convenient fitting formulae and open access to the photon and neutrino tracks for more sophisticated population synthesis models.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Microdosimetry of proton and carbon ions

Purpose: To investigate microdosimetry properties of 160 MeV/u protons and 290 MeV/u{sup 12}C ion beams in small volumes of diameters 10–100 nm. Methods: Energy distributions of primary particles and nuclear fragments in the beams were calculated from simulations with the general purpose code SHIELD-HIT, while energy depositions by monoenergetic ions in nanometer volumes were obtained from the event-by-event Monte Carlo track structure ion code PITS99 coupled with the electron track structure code KURBUC. Results: The results are presented for frequencies of energy depositions in cylindrical targets of diameters 10–100 nm, dose distributionsyd(y) in lineal energy y, and dose-mean lineal energies y{sup ¯}{sub D}. For monoenergetic ions, the y{sup ¯}{sub D} was found to increase with an increasing target size for high-linear energy transfer (LET) ions, but decrease with an increasing target size for low-LET ions. Compared to the depth dose profile of the ion beams, the maximum of the y{sup ¯}{sub D} depth profile for the 160 MeV proton beam was located at ∼0.5 cm behind the Bragg peak maximum, while the y{sup ¯}{sub D} peak of the 290 MeV/u {sup 12}C beam coincided well with the peak of the absorbed dose profile. Differences between the y{sup ¯}{sub D} and dose-averaged linear energy transfer (LET{sub D}) were large in the proton beam for both target volumes studied, and in the {sup 12}C beam for the 10 nm diameter cylindrical volumes. The y{sup ¯}{sub D} determined for 100 nm diameter cylindrical volumes in the {sup 12}C beam was approximately equal to the LET{sub D}. The contributions from secondary particles to the y{sup ¯}{sub D} of the beams are presented, including the contributions from secondary protons in the proton beam and from fragments with atomic number Z = 1–6 in the {sup 12}C beam. Conclusions: The present investigation provides an insight into differences in energy depositions in subcellular-size volumes when irradiated by proton and carbon ion beams. The results are useful for characterizing ion beams of practical importance for biophysical modeling of radiation-induced DNA damage response and repair in the depth profiles of protons and carbon ions used in radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-track reconstruction algorithm in the Mu2e experiment

The Mu2e experiment, under construction at Fermilab, will search for the neutrino-less coherent $\mu^-N\rightarrow e^-N$ conversion in the field of a $^{27}$Al nucleus. Such a process violates lepton flavor conservation. About $60\%$ of muons stopped by an $^{27}$Al nucleus will undergo nuclear capture, while about $40\%$ will decay in orbit. To quantify the conversion probability, we define $R_{\mu e}$, which is given by the ratio between the $\mu^-\rightarrow e^-$ conversion rate and the nuclear capture rate [1]: \begin{equation} R_{\mu e}= \frac{\Gamma\left(\mu^- + N\left(Z,A\right)\rightarrow e^- + N\left(Z,A\right)\right)}{\Gamma\left(\mu^- + N\left(Z,A\right)\rightarrow \nu^-_\mu + N\left(Z-1,A\right)\right)}\,. \end{equation} The upper limit on $R_{\mu e}$ is $7\cdot 10^{-13}$ at $90\%$ CL, set by the SINDRUM II experiment~\cite{SINDRUM II:limit}. The goal of the Mu2e experiment is to reach a sensitivity on $R_{\mu e}$ of $8\cdot 10^{-17}$ at $90\%$ CL. This represents a four-order of magnitude improvement over the current experimental limit. Mu2e will take its first data in 2027. The signature for the muon conversion is a monochromatic electron of $104.97$~\si{\mega\eV}/c, an energy slightly below the muon rest mass. While the main experiment goal is to reconstruct the conversion electron, i.e., an event with a single track, there are motivations to develop an efficient tracking algorithm for reconstructing more simultaneous tracks. This could better constrain the background generated by $p\bar{p}$-annihilation in the Al target and to search for other Beyond the Standard Model processes. In this paper, we present an algorithm designed to reconstruct multi-particle events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the construction of the Gluex Forward Drift Chambers

Currently under construction at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, the full GlueX detector is designed to study gluonic degrees of freedom through the production of ``hybrid'' mesons with exotic quantum numbers. To accomplish this task the detector requires high acceptance and reasonably good resolution for both charged and neutral particles. The core of the detector is housed within the bore of a 2.0 Tesla solenoidal magnet. Charged particles emanating from the target for angles greater than about 20 degrees with respect to the beam line will be tracked with a straw-tube detector (the Central Drift Chamber). Forward-going charged particles will be detected using the Forward Drift Chambers (FDC). I will describe the design and construction of the FDC and present preliminary resolution measurements.

Taylor, Simon↗

Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method

Purpose: Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for both rigid and nonrigid respiration-induced target motion based on 4D computed tomography (4DCT) data sets. Methods: A set of MLC apertures and weights was first optimized on a reference phase of a 4DCT data set. At each beam angle, the apertures were morphed from the reference phase to each of the remaining phases according to the relative shape changes in the beam's eye view of the target. Three different planning schemes were evaluated for two lung cases and one pancreas patient: (1) Individually optimizing each breathing phase; (2) optimizing the reference phase and shifting the optimized apertures to other breathing phases based on a rigid-body image registration; and (3) optimizing the reference phase and deforming the optimized apertures to the other phases based on the deformation and translation of target contours. Planning results using scheme 1 serves as the ''gold standard'' for plan quality assessment; scheme 2 is the method previously proposed in the literature; and scheme 3 is the method the authors proposed in this article. The optimization results were compared between the three schemes for all three cases. Results: The proposed scheme 3 is comparable to scheme 1 in plan quality, and provides improved target coverage and conformity with similar normal tissue dose compared with scheme 2. Conclusions: Direct aperture deformation method for 4D IMRT planning improves upon methods that only consider rigid-body motion and achieves a plan quality close to that optimized for each of the phases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluctuations of the number of neutral pions at high multiplicity in pp interactions at 50 GeV

Results obtained by measuring fluctuations of the number of neutral pions in the SERP-E-190 Experiment (Thermalization Project) upon irradiating a liquid-hydrogen target of the SVD-2 setup with a beam of 50-GeV protons are presented. A simulation of the detection of photons from the decay of neutral pions with the aid of an electromagnetic calorimeter revealed a linear relation between the number of detected photons and the mean number of neutral pions in an event. After the introduction of corrections for the loss of charged tracks because of a limited acceptance of the setup, trigger operation, and the efficiency of the data-treatment system, distributions of the number of neutral pions, N{sub 0}, were obtained for each value of the total number of particles in an event, N{sub tot} = N{sub ch} + N{sub 0}. The fluctuation parameter {omega} = D/ Left-Pointing-Angle-Bracket N{sub 0} Right-Pointing-Angle-Bracket was measured. In the region N{sub tot} > 22, fluctuations of the number of neutral pions increase, which, within statistical models (GCE, CE, MCE), indicates that the system involving a large number of pions approaches the pion-condensate state. This effect was observed for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating the Effectiveness of a Detection and Deterrent System in Reducing Golden Eagle Fatalities at Operational Wind Facilities

The Renewable Energy Wildlife Institute (REWI) was appointed as the prime awardee of DOE award number DE-EE0007883 to lead a team of scientists, wind developers, and technology manufacturers toward the overarching goal of evaluating the effectiveness of the current DTBird system in minimizing the risk of golden eagles (Aquila chrysaetos) and other large soaring raptors from approaching the rotor-swept zone (RSZ) of operating wind turbines. As part of this goal, the team set out to 1) quantify the expected reduction in collision risk for golden eagles from operation of the detection and deterrence modules in a manner that supports the approach used by the U.S. Fish and Wildlife Service (USFWS) to assess and credit facility operators for their efforts to minimize predicted collision fatalities and 2) provide information to help improve the technology to maximize its effectiveness. DTBird is an automated detection and audio deterrent system created by the Spanish company Liquen, designed to discourage birds from entering the RSZ of spinning wind turbines. The system uses cameras to automatically detect airborne targets of interest, records each such event in an online database, and triggers a warning signal (loud sound) if the tracked object has moved close to the turbine. If the object moves even closer to the RSZ, a more aggressive dissuasion signal is broadcast. To meet our objectives, the team conducted a two-year experiment at the Goodnoe Hills wind facility in Washington state, in which 14 turbines were outfitted with DTBird units. Daily, each DTBird-equipped turbine was randomly assigned to a control or treatment group. Treatment turbines operated with DTBird running as intended—broadcasting warning or deterrent signals when DTBird detected a target within range. On control turbines, no sound signals were broadcast if a moving target triggered the DTBird system. The team also flew unmanned aerial vehicles (UAVs) designed to coarsely mimic the general size, weight, and coloration of golden eagles in programmed flight transects across DTBird detection ranges to quantify DTBird’s ability to detect intended targets and to evaluate factors that influence the probability of detection and DTBird’s response distances. Additionally, the team evaluated the behavioral responses of in situ eagles exposed to spinning turbines alone (visual and sound influences) versus spinning turbines plus broadcasted DTBird audio deterrents, to estimate the effectiveness of deterrence by the DTBird system. The data and results from these investigations were combined with those from a pilot study conducted at the Manzana Wind Power Project in California to better evaluate DTBird’s effectiveness across different landscapes.

17 WIND ENERGY↗

M-dwarf rapid rotators and the detection of relatively young multiple M-star systems

We have searched the Kepler light curves of ∼3900 M-star targets for evidence of periodicities that indicate, by means of the effects of starspots, rapid stellar rotation. Several analysis techniques, including Fourier transforms, inspection of folded light curves, 'sonograms', and phase tracking of individual modulation cycles, were applied in order to distinguish the periodicities due to rapid rotation from those due to stellar pulsations, eclipsing binaries, or transiting planets. We find 178 Kepler M-star targets with rotation periods, P {sub rot}, of <2 days, and 110 with P {sub rot} < 1 day. Some 30 of the 178 systems exhibit two or more independent short periods within the same Kepler photometric aperture, while several have 3 or more short periods. Adaptive optics imaging and modeling of the Kepler pixel response function for a subset of our sample support the conclusion that the targets with multiple periods are highly likely to be relatively young physical binary, triple, and even quadruple M star systems. We explore in detail the one object with four incommensurate periods all less than 1.2 days, and show that two of the periods arise from one of a close pair of stars, while the other two arise from the second star, which itself is probably a visual binary. If most of these M-star systems with multiple periods turn out to be bound M stars, this could prove a valuable way discovering young hierarchical M-star systems; the same approach may also be applicable to G and K stars. The ∼5% occurrence rate of rapid rotation among the ∼3900 M star targets is consistent with spin evolution models that include an initial contraction phase followed by magnetic braking, wherein a typical M star can spend several hundred Myr before spinning down to periods longer than 2 days.

79 ASTRONOMY AND ASTROPHYSICS↗

Lifetime measurements of states of S 35 , S 36 , S 37 , and S 38 using the AGATA γ -ray tracking spectrometer

Lifetimes or lifetime limits of a small number of excited states of the sulfur isotopes with mass numbers A = 35 , 36, 37, and 38 have been measured using the differential recoil-distance method. The isotopes of sulfur were populated in binary grazing reactions initiated by a beam of 36 S ions of energy 225 MeV incident on a thin 208 Pb target which was mounted in the Cologne plunger apparatus. The combination of the PRISMA magnetic spectrometer and an early implementation of the AGATA γ-ray tracking array was used to detect γ rays in coincidence with projectile-like nuclear species. Lifetime measurements of populated states were measured within the range from about 1 to 100 ps. The number of states for which lifetime measurements or lifetime limits were possible was limited by statistics. For 35 S, the lifetime was determined for the first 1/2 + state at 1572 keV; the result is compared with a previous published lifetime value. The lifetime of the 3 - state of 36 S at 4193 keV was determined and compared with earlier measurements. No previous lifetime information exists for the (6 + ) state at 6690 keV; a lifetime measurement with large associated error was made in the present work. For 37 S, the states for which lifetime limits were established were those at 646 keV with J π = 3/2 - and at 2776 keV with J π = 11/2 - ; there are no previously published lifetime values for excited states of 37 S. Finally, a lifetime limit was established for the J π =(6 + ) state of 38 S at 3675 keV; no lifetime information exists for this state in the literature. Measured lifetime values were compared with the results of state-of-the-art shell-model calculations based on the PSDPF, SDPF-U, and FSU effective interactions. In addition, nuclear magnetic-dipole and electric-quadrupole moments, branching ratios, mixing ratios, and electromagnetic transition rates, where available, have been compared with shell-model values. The current work suffers from poor statistics; nevertheless, lifetime values and limits have been possible, allowing a useful discussion of the ability of state-of-the-art shell-model calculations to reproduce the experimental results.

electromagnetic transitions↗

SU-D-BRB-04: Plan Quality Comparison of Intracranial Stereotactic Radiosurgery (SRS) for Gamma Knife and VMAT Treatments

Purpose: To compare treatment plan quality of intracranial stereotactic radiosurgery (SRS) for VMAT (RapidArc) and Gamma Knife (GK) systems. Methods: Ten patients with 24 tumors (seven with 1–2 and three with 4–6 lesions), previously treated with GK 4C (prescription doses ranging from 14–23 Gy) were re-planned for RapidArc. Identical contour sets were kept on MRI images for both plans with tissues assigned a CT number of zero. RapidArc plans were performed using 6 MV flattening-filter-free (FFF) beams with dose rate of 1400 MU/minute using two to eight arcs with the following combinations: 2 full coplanar arcs and the rest non-coplanar half arcs. Beam selection was based on target depth. Areas that penetrated more than 10 cm of tissue were avoided by creating smaller arcs or using avoidance sectors in optimization. Plans were optimized with jaw tracking and a high weighting to the normal-brain-tissue and Normal-Tissue-Objective without compromising PTV coverage. Plans were calculated on a 1 mm grid size using AAA algorithm and then normalized so that 99% of each target volume received the prescription dose. Plan quality was assessed by target coverage using Paddick Conformity Index (PCI), sparing of normal-brain-tissue through analysis of V4, V8, and V12 Gy, and integral dose. Results: In all cases critical structure dose criteria were met. RapidArc had a higher PCI than GK plans for 23 out of 24 lesions. The average PCI was 0.76±0.21 for RapidArc and 0.46±0.20 for GK plans (p≤0.001), respectively. Integral dose and normal-brain-tissue doses for all criteria were lower for RapidArc in nearly all patients. The average ratio of GK to RapidArc plans was 1.28±0.27 (p=0.018), 1.31±0.25 (p=0.017), 1.81±0.43 (p=0.005), and 1.50±0.61 (p=0.006) for V4, V8, and V12 Gy, and integral dose, respectively. Conclusion: VMAT was capable of producing higher quality treatment plans than GK when using optimal beam geometries and proper optimization techniques.

60 APPLIED LIFE SCIENCES↗

Early stage of the electron kinetics in swift heavy ion tracks in dielectrics

A Monte Carlo approach was applied for simulations of the early stage (first tens of femtosecond) of kinetics of the electronic subsystem of silica (SiO{sub 2}) in tracks of swift heavy ions (SHIs) decelerated in the electronic stopping regime. At the first step multiple ionizations of target atoms by a projectile (Ca{sup +19}, E=11.4 MeV/amu) were described that gave the initial spatial distributions of free electrons having different momenta as well as distributions of holes in different atomic shells. Spatial propagation of fast electrons results in secondary ionizations of target atoms as well as in energy transfer to the lattice at times much shorter than the times of atomic oscillations (phonons). The well detected front of excitation in the electronic and ionic subsystems is formed due to this propagation which cannot be described by models based on diffusion mechanisms (e.g., parabolic equations of heat diffusion). At times {approx}10 fs after the projectile passage, about {approx}0.1% of the energy is already transferred to the lattice. About 63% of the energy deposited by the ion is accumulated in holes at these times. Calculated distributions of these holes through the atomic shells are in excellent agreement with the spectroscopy experiments. Comparison with these experiments demonstrated also that relaxation of the electronic subsystem in SHI tracks in solids cannot be described adequately without taking into account intra-atomic and interatomic Auger (Knotek-Feibelman) processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of ion-induced sputtering to the radial distribution of energy transfers: A molecular dynamics study

Using different models for the deposition of energy on the lattice and a classical molecular dynamics approach to the subsequent transport, we evaluate how the details of the energy deposition model influence sputtering yield from a Lennard-Jones target irradiated with a MeV/u ion beam. Two energy deposition models are considered: a uniform, instantaneous deposition into a cylinder of fixed radius around the projectile ion track, used in earlier molecular dynamics and fluid dynamics simulations of sputtering yields; and an energy deposition distributed in time and space based on the formalism developed in the thermal spike model. The dependence of the sputtering yield on the total energy deposited on the target atoms is very sensitive to the energy deposition model. To clarify the origin of this strong dependence, we explore the role of the radial expansion of the electronic system prior to the transfer of its energy to the lattice. The results imply that observables such as the sputtering yield may be used as signatures of the fast electron-lattice energy transfer in the electronic energy-loss regime, and indicate the need for more experimental and theoretical investigations of these processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Organ Deformation and Dose Coverage in Robotic Respiratory-Tracking Radiotherapy

Purpose: Respiratory motion presents a significant challenge in stereotactic body radiosurgery. Respiratory tracking that follows the translational movement of the internal fiducials minimizes the uncertainties in dose delivery. However, the effect of deformation, defined as any changes in the body and organs relative to the center of fiducials, remains unanswered. This study investigated this problem and a possible solution. Methods and Materials: Dose delivery using a robotic respiratory-tracking system was studied with clinical data. Each treatment plan was designed with the computed tomography scan in the end-expiration phase. The planned beams were applied to the computed tomography scan in end-inspiration following the shift of the fiducials. The dose coverage was compared with the initial plan, and the uncertainty due to the deformation was estimated. A necessary margin from the clinical target volume to the planning target volume was determined to account for this and other sources of uncertainty. Results: We studied 12 lung and 5 upper abdomen lesions. Our results demonstrated that for lung patients with properly implanted fiducials a 3-mm margin is required to compensate for the deformation and a 5-mm margin is required to compensate for all uncertainties. Our results for the upper abdomen tumors were still preliminary but indicated a similar result, although a larger margin might be required. Conclusion: The effect of body deformation was studied. We found that adequate dose coverage for lung tumors can be ensured with proper fiducial placement and a 5-mm planning target volume margin. This approach is more practical and effective than a recent proposal to combine four-dimensional planning with respiratory tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vibronic-structure tracking: A shortcut for vibrationally resolved UV/Vis-spectra calculations

The vibrational coarse structure and the band shapes of electronic absorption spectra are often dominated by just a few molecular vibrations. By contrast, the simulation of the vibronic structure even in the simplest theoretical models usually requires the calculation of the entire set of normal modes of vibration. Here, we exploit the idea of the mode-tracking protocol [M. Reiher and J. Neugebauer, J. Chem. Phys. 118, 1634 (2003)] in order to directly target and selectively calculate those normal modes which have the largest effect on the vibronic band shape for a certain electronic excitation. This is achieved by defining a criterion for the importance of a normal mode to the vibrational progressions in the absorption band within the so-called “independent mode, displaced harmonic oscillator” (IMDHO) model. We use this approach for a vibronic-structure investigation for several small test molecules as well as for a comparison of the vibronic absorption spectra of a truncated chlorophyll a model and the full chlorophyll a molecule. We show that the method allows to go beyond the often-used strategy to simulate absorption spectra based on broadened vertical excitation peaks with just a minimum of computational effort, which in case of chlorophyll a corresponds to about 10% of the cost for a full simulation within the IMDHO approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Heavy Photon Search experiment at Jefferson Laboratory

The Heavy Photon Search experiment (HPS) at Jefferson Laboratory will search for a new U(1) massive gauge boson, or "heavy-photon", mediator of a new fundamental interaction, called "dark-force", that couples to ordinary photons through kinetic mixing. HPS has sensitivity in the mass range 20 MeV – 1 GeV and coupling epsilon2 between 10 -5 and 10 -10 . The HPS experiment will look for the e+e- decay of the heavy photon, by resonance search and detached vertexing, in an electron beam fixed target experiment. HPS will use a compact forward spectrometer, which employs silicon microstrip detectors for vertexing and tracking, and a PbWO4 electromagnetic calorimeter for energy measurement and fast triggering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complete set of bound negative-parity states in the neutron-rich nucleus 18 N

High-resolution γ -ray spectroscopy of N 18 is performed with the Advanced GAmma Tracking Array, following deep-inelastic processes induced by an O 18 beam on a Ta 181 target. Six states are newly identified, which together with the three known excitations exhaust all negative-parity excited states expected in N 18 below the neutron threshold. Spin and parities are proposed for all located states on the basis of decay branchings and comparison with large-scale shell-model calculations performed in the p-sd space, with the YSOX interaction. Of particular interest is the location of the 0 1 - and 1 2 - excitations, which provide strong constrains for cross-shell p-sd matrix elements based on realistic interactions and help to simultaneously reproduce the ground and first-excited states in N 16 and N 18 , for the first time. Overall, understanding the N 18 structure may also have significant impact on neutron-capture cross-section calculations in r-process modeling including light neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TU-AB-202-07: A Novel Method for Registration of Mid-Treatment PET/CT Images Under Conditions of Tumor Regression for Patients with Locally Advanced Lung Cancers

Purpose: In PET-guided adaptive radiotherapy (RT), changes in the metabolic activity at individual voxels cannot be derived until the duringtreatment CT images are appropriately registered to pre-treatment CT images. However, deformable image registration (DIR) usually does not preserve tumor volume. This may induce errors when comparing to the target. The aim of this study was to develop a DIR-integrated mechanical modeling technique to track radiation-induced metabolic changes on PET images. Methods: Three patients with non-small cell lung cancer (NSCLC) were treated with adaptive radiotherapy under RTOG 1106. Two PET/CT image sets were acquired 2 weeks before RT and 18 fractions after the start of treatment. DIR was performed to register the during-RT CT to the pre-RT CT using a B-spline algorithm and the resultant displacements in the region of tumor were remodeled using a hybrid finite element method (FEM). Gross tumor volume (GTV) was delineated on the during-RT PET/CT image sets and deformed using the 3D deformation vector fields generated by the CT-based registrations. Metabolic tumor volume (MTV) was calculated using the pre- and during–RT image set. The quality of the PET mapping was evaluated based on the constancy of the mapped MTV and landmark comparison. Results: The B-spline-based registrations changed MTVs by 7.3%, 4.6% and −5.9% for the 3 patients and the correspondent changes for the hybrid FEM method −2.9%, 1% and 6.3%, respectively. Landmark comparisons were used to evaluate the Rigid, B-Spline, and hybrid FEM registrations with the mean errors of 10.1 ± 1.6 mm, 4.4 ± 0.4 mm, and 3.6 ± 0.4 mm for three patients. The hybrid FEM method outperforms the B-Spline-only registration for patients with tumor regression Conclusion: The hybrid FEM modeling technique improves the B-Spline registrations in tumor regions. This technique may help compare metabolic activities between two PET/CT images with regressing tumors. The author gratefully acknowledges the financial support from the National Institutes of Health Grant.

60 APPLIED LIFE SCIENCES↗