Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit↗

Thermal death of a hydrocarbon bacterium in a nonaqueous fluid

A hydrocarbon-utilizing Brevibacterium which grew into the oil phase of an oil-water system was tested for survival at elevated temperature. Cells suspended in oil and cells that had been resuspended in aqueous solution were tested by placing 1-ml samples of the cell suspension in small test tubes immersed in a controlled-temperature water bath. The resultant survival curves in oil consisted of two parts, a flat shoulder obtained in the first half of the heating period, followed by a break indicating rapid die-off. The break in the curves occurred after 50% of the cells were killed. This occurred at exposures of 25, 15, and 8 min for 78, 88.6, and 96.2 C, respectively. The survival curve for 63.5 C in the aqueous solution was a rapid, exponential die-off. The actual increase in survival of the organism in oil is reflected by the length of the shoulder portion. The shoulder occurs only in an oil medium and is increased by decreasing temperature and increasing age of the culture.

Severance, M. M.↗

ATS-6 - Flight performance of the Advanced Thermal Control Flight Experiment

The Advanced Thermal Control Flight Experiment on ATS-6 was designed to demonstrate the thermal control capability of a thermal diode (one-way) heat pipe, a phase-change material for thermal storage, and a feedback-controlled heat pipe. Flight data for the different operational modes are compared to ground test data, and the performance of the components is evaluated on an individual basis and as an integrated temperature-control system.

Kirkpatrick, J. P.↗

Alternatives to ozone depleting refrigerants in test equipment

This paper describes the initial results of a refrigerant retrofit project at the Aerospace Guidance and Metrology Center (AGMC) at Newark Air Force Base, Ohio. The objective is to convert selected types of test equipment to properly operate on hydrofluorocarbon (HFC) alternative refrigerants, having no ozone depleting potential, without compromising system reliability or durability. This paper discusses the primary technical issues and summarizes the test results for 17 different types of test equipment: ten environmental chambers, two ultralow temperature freezers, two coolant recirculators, one temperature control unit, one vapor degreaser, and one refrigerant recovery system. The postconversion performance test results have been very encouraging: system capacity and input power remained virtually unchanged. In some cases, the minimum operating temperature increased by a few degrees as a result of the conversion, but never beyond AGMC's functional requirements.

Hall, Richard L.↗

Pump and Flow Control Subassembly of Thermal Control Subsystem for Photovoltaic Power Module

The pump and flow control subassembly (PFCS) is an orbital replacement unit (ORU) on the Space Station Freedom photovoltaic power module (PVM). The PFCS pumps liquid ammonia at a constant rate of approximately 1170 kg/hr while providing temperature control by flow regulation between the radiator and the bypass loop. Also, housed within the ORU is an accumulator to compensate for fluid volumetric changes as well as the electronics and firmware for monitoring and control of the photovoltaic thermal control system (PVTCS). Major electronic functions include signal conditioning, data interfacing and motor control. This paper will provide a description of each major component within the PFCS along with performance test data. In addition, this paper will discuss the flow control algorithm and describe how the nickel hydrogen batteries and associated power electronics will be thermally controlled through regulation of coolant flow to the radiator.

Motil, Brian↗

Test and Analysis Capabilities of the Space Environment Effects Team at Marshall Space Flight Center

Marshall Space Flight Center has developed world-class space environmental effects testing facilities to simulate the space environment. The combined environmental effects test system exposes temperature-controlled samples to simultaneous protons, high- and low-energy electrons, vacuum ultraviolet (VUV) radiation, and near-ultraviolet (NUV) radiation. Separate chambers for studying the effects of NUV and VUV at elevated temperatures are also available. The Atomic Oxygen Beam Facility exposes samples to atomic oxygen of 5 eV energy to simulate low-Earth orbit (LEO). The LEO space plasma simulators are used to study current collection to biased spacecraft surfaces, arcing from insulators and electrical conductivity of materials. Plasma propulsion techniques are analyzed using the Marshall magnetic mirror system. The micro light gas gun simulates micrometeoroid and space debris impacts. Candidate materials and hardware for spacecraft can be evaluated for durability in the space environment with a variety of analytical techniques. Mass, solar absorptance, infrared emittance, transmission, reflectance, bidirectional reflectance distribution function, and surface morphology characterization can be performed. The data from the space environmental effects testing facilities, combined with analytical results from flight experiments, enable the Environmental Effects Group to determine optimum materials for use on spacecraft.

Finckenor, M. M.↗

Investigating Radiation-Induced Actinide Species in Solution

Our fundamental understanding of actinide radiation-induced redox chemistry is crucial to nuclear fuel cycle development, due to the unavoidable exposure of these elements to ionizing radiation fields, both inherent and from in-process applications. Plutonium (Pu) and americium (Am) both possess multiple oxidation states, the careful manipulation of which are essential in the study and utilization of their rich chemistry, developing new nuclear technologies, and securing the long-term sustainability of nuclear power. However, knowledge in this area is far from complete. Consequently, we have studied the radiation-induced chemistry of both Pu and Am through a variety of techniques. Temperature-controlled electron pulse radiolysis has been used to study Am for the first time, determining the feasibility of Am redox reactions under used nuclear fuel reprocessing conditions, (e.g. nitric acid, non-ambient temperature). Additionally, we have developed an experimentally evaluated multi-scale computer model for the prediction of gamma radiation-induced Pu redox chemistry due to radiolysis and disproportionation reactions in concentrated nitric acid solutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating Radiation-Induced Actinide Species in Solution

Our fundamental understanding of actinide radiation-induced redox chemistry is crucial due to their unavoidable exposure to ionizing radiation fields, both inherent and from in-process applications. Plutonium (Pu) and americium (Am) both possess multiple oxidation states, the careful manipulation of which are essential in the study and utilization of their rich chemistry, developing new nuclear technologies, and securing the long-term sustainability of nuclear power. However, knowledge in this area is far from complete. Consequently, we have studied the radiation-induced chemistry of both Pu and Am through a variety of techniques. Temperature-controlled electron pulse radiolysis has been used to study Am for the first time, determining the feasibility of Am redox reactions under used nuclear fuel reprocessing conditions, (e.g. nitric acid, non-ambient temperature). Additionally, we developed an experimentally evaluated multi-scale computer model for the prediction of gamma radiation-induced Pu redox chemistry due to radiolysis and disproportionation reactions in concentrated nitric acid solutions.

actinide↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Disassembly and Initial Post-Irradiation Examination of the Mini99 Experiment

The Miniature Fuel Molybdenum-99 (Mini99) experiment is a first-of-a-kind experiment in the High Flux Isotope Reactor. Mini99 is the first MiniFuel irradiation experiment to use liquid metal inside the MiniFuel subcapsule for additional temperature control. In this work, the initial post-irradiation examination is reported. As-built simulations were conducted and compared with designs, and physical post-irradiation examinations were conducted to determine actual test temperatures via SiC thermometry samples, to evaluate the extent of fission gas release from the samples, and to remove the fuel from the subcapsules. As-built simulations compared well with experiment designs and were in reasonable agreement with the measured temperatures inferred from the passive SiC thermometers. Additionally, fission gas release values were relatively small (on the order of 3%); one sample reached approximately 8%. Although some of this behavior is attributable to recoil, most of the gas release was likely caused by the physics of the fuel behavior during the test. Finally, disassembly showed that at least four of the fuel samples degraded into small components and granules at some point during the test, with the state of the other two samples unproven. Additional work is planned for further examination of these samples via various microscopy techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Viking Mars Orbiter 1975 solar energy controller

The Jet Propulsion Laboratory is responsible for the Viking Orbiter System, which is part of the overall Viking Project managed by the Viking Project Office at Langley Research Center for NASA. The spacecraft will be launched on a Titan IIIE/-Centaur Launch Vehicle in August 1975. Solar energy for temperature control purposes is introduced into the propulsion module of the Orbiter. The energy enters by way of four individually commandable solar energy controllers (SECs). This paper summarizes the SEC thermal development, design and test results. Test results are presented for the prototype unit and for the flight units.

Stultz, J. W.↗

Digital Control of Durability-Testing Burner Rigs

Report describes hardware and software that implement hybrid digital control of two Jet A-1 fueled, mach-0.3 burners from startup to completion of preset number of hot-corrosion/flame-durability cycle tests of materials at 1,652 degree F (900 degree C). Surface temperatures controlled more precisely than before.

Deadmore, D. L.↗

The Initial Blood Storage Experiment - The spaceflight hardware program

The Initial Blood Storage Experiment (IBSE) was conceived to investigate the effects of microgravity on the formed elements of human blood. The experiment flew on the January 1986, 61-C mission of the Space Shuttle Columbia. The experiment hardware was designed to provide a closely controlled temperature and air flow environment for all blood samples. During the mission, two IBSE modules were on board the orbiter and an identical set of hardware and blood samples were maintained on earth as a control. This paper describes the development and performance of the IBSE hardware which was converted from a conceptual design to an on-orbit, man-rated, mid-deck locker experiment in 17 months.

Almgren, David W.↗

Space shuttle heat pipe thermal control systems

Heat pipe (HP) thermal control systems designed for possible space shuttle applications were built and tested under this program. They are: (1) a HP augmented cold rail, (2) a HP/phase change material (PCM) modular heat sink and (3) a HP radiating panel for compartment temperature control. The HP augmented cold rail is similar to a standard two-passage fluid cold rail except that it contains an integral, centrally located HP throughout its length. The central HP core helps to increase the local power density capability by spreading concentrated heat inputs over the entire rail. The HP/PCM modular heat sink system consists of a diode HP connected in series to a standard HP that has a PCM canister attached to its mid-section. It is designed to connect a heat source to a structural heat sink during normal operation, and to automatically decouple from it and sink to the PCM whenever structural temperatures are too high. The HP radiating panel is designed to conductively couple the panel feeder HPs directly to a fluid line that serves as a source of waste heat. It is a simple strap-on type of system that requires no internal or external line modifications to distribute the heat to a large radiating area.

Alario, J.↗

Thermal Vacuum Testing of a Multi-Evaporator Miniature Loop Heat Pipe

Under NASA's New Millennium Program Space Technology 8 Project, four experiments are being developed for future small system applications requiring low mass, low power, and compactness. GSFC is responsible for developing the Thermal Loop experiment, which is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and condensers. The objective is to validate the operation of an MLHP, including reliable start-ups, steady operation, heat load sharing, and tight temperature control over the range of 273K to 308K. An MLHP Breadboard has been built and tested for 1200 hours under the laboratory environment and 500 hours in a thermal vacuum chamber. Results of the TV tests are presented here.

Ku, Jentung↗

Thermal design of the sample handling assembly in the sampling and caching subsystem on the Mars 2020 rover

The Mars 2020 Rover is scheduled to land on Mars on February 18, 2021. One of the primary mission objectives for the Mars 2020 Rover is to collect a set of Martian regolith samples for potential future return to Earth. Regolith and rock samples will be collected and placed into sample tubes using a coring drill, located at the end of a large Robotic Arm, on the outside of the rover. Filled sample tubes will be transferred from the outside of the Rover into the Adaptive Caching Assembly (ACA), located inside the Rover chassis, via the Bit Carousel. Once the filled sample tube is brought into the ACA, the Sample Handling Assembly (SHA) will transfer it to all of the internal processing stations of the ACA for volume assessment, sealing and finally drop-off on the Martian surface. The ACA is a volume within the rover chassis that is not temperature-controlled. Actuators inside the SHA and its End Effector (EE) must be warmed to above -55°C and -25°C, respectively, prior to use. This paper discusses the thermal design of the SHA that uses heaters and temperature sensors to warm up and maintain the temperature-sensitive arm components within temperature limits during operation. Thermal performance predictions for Mars surface operations are also presented.

Lee, Chern-Jiin↗