TERRA Battery Thermal Control Anomaly - Simulation and Corrective Actions

The TERRA spacecraft was launched in December 1999 from Vandenberg Air Force Base, becoming the flagship of NASA's Earth Observing System program to gather data on how the planet's processes create climate. Originally planned as a 5 year mission, it still provides valuable science data after nearly 10 years on orbit. On October 13th, 2009 at 16:23z following a routine inclination maneuver, TERRA experienced a battery cell failure and a simultaneous failure of several battery heater control circuits used to maintain cell temperatures and gradients within the battery. With several cells nearing the minimum survival temperature, preventing the electrolyte from freezing was the first priority. After several reset attempts and power cycling of the control electronics failed to reestablish control authority on the primary side of the controller, it was switched to the redundant side, but anomalous performance again prevented full heater control of the battery cells. As the investigation into the cause of the anomaly and corrective action continued, a battery thermal model was developed to be used in determining the control ability remaining and to simulate and assess corrective actions. Although no thermal model or detailed reference data of the battery was available, sufficient information was found to allow a simplified model to be constructed, correlated against pre-anomaly telemetry, and used to simulate the thermal behavior at several points after the anomaly. It was then used to simulate subsequent corrective actions to assess their impact on cell temperatures. This paper describes the rapid development of this thermal model, including correlation to flight data before and after the anomaly., along with a comparative assessment of the analysis results used to interpret the telemetry to determine the extent of damage to the thermal control hardware, with near-term corrective actions and long-term operations plan to overcome the anomaly.

Grob, Eric W.↗

COI Structural Analysis Presentation

This report discusses the structural analysis of the Next Generation Space Telescope Mirror System Demonstrator (NMSD) developed by Composite Optics Incorporated (COI) in support of the Next Generation Space Telescope (NGST) project. The mirror was submitted to Marshall Space Flight Center (MSFC) for cryogenic testing and evaluation. Once at MSFC, the mirror was lowered to approximately 40 K and the optical surface distortions were measured. Alongside this experiment, an analytical model was developed and used to compare to the test results. A NASTRAN finite element model was provided by COI and a thermal model was developed from it. Using the thermal model, steady state nodal temperatures were calculated based on the predicted environment of the large cryogenic test chamber at MSFC. This temperature distribution was applied in the structural analysis to solve for the deflections of the optical surface. Finally, these deflections were submitted for optical analysis and comparison to the interferometer test data.

Cline, Todd↗

Electrical Modeling and Thermal Analysis Toolbox (EMTAT) User’s Guide

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this User's Guide is to present an overview of the usage of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will describe the basic usage of the software toolbox, and also provide an example of EAP system modeling using EMTAT.

Mark E. Bell↗

Development of the METMAN Thermal Desktop Human Model for System Integration

Human thermal analysis and model development inform NASA’s space suit development, vehicle/habitat design, and survivability studies. Historically, human thermal models such as the 41-node metabolic man (METMAN) and the Wissler model have been standalone software tools developed with FORTRAN, a programming language known for its high performance in computationally intensive applications. Though efficient, these standalone programs pose challenges to coupled human-system analysis with detailed life support and thermal control subsystem models in other commercial software. This paper describes the conversion of the METMAN human thermal model from a standalone FORTRAN program to a model in Thermal Desktop (Ansys), a commonly used CAD-based simulation software for engineering that specializes in heat transfer, thermal radiation, and fluid flow analysis. This format was chosen to best facilitate model sharing and compatibility, enabling the direct integration of METMAN human thermal analysis with subsystem models across NASA programs and commercial partners.

Elizabeth Thurston↗

Real-Time Modeling of Thermal Interactions in Cryogenic Ball Bearings

Based on the integration of classical differential equations of motion of bearing elements, a real-time dynamic simulation of ball bearing performance is coupled with simultaneous modeling of thermal interactions between the bearing elements. The transient heat generations are time averaged over a significantly larger time step before they are used to compute the changes in bearing temperature fields. Such an averaging algorithm eliminates the numerical difficulties associated with simultaneous integration of mechanical thermal differential equations with vastly different time scales. Under stable operation, the step change in temperatures at each thermal time step converges to a steady-state solution. Following is a list of accomplishments in the present investigation: (1) A real-time dynamic performance of both 440C and hybrid ball bearings in a LOX environment is modeled in both transient and steady-state time domains, as the inner race accelerates to a prescribed operating speed. (2) The frictional interactions at the ball to race contacts are modeled by experimentally measured traction coefficients as a function of slide-to-roll ratios. (3) Bearing heat generation, as defined by the heat transferred to circulating LOX, is validated against experimental values determined by measured LOX temperatures under prescribed pressures and flow rates. The predicted heat generation is in good agreement with the experimental values. (4) The steady-state solutions are shown to be independent of initial conditions. This establishes convergence of the numerical integration of a differential equation of motion of the bearing elements. (5) Churning and drag losses in the circulating LOX constitutes the majority of bearing heat generation under the experimental test conditions. (6) The heat dissipated in frictional interactions in hybrid bearings is significantly lower in hybrid bearings in comparison to that simulated in all-steel bearings, while the churning and drag losses are relatively unchanged.

Gupta, P. K.↗

An Overview of Thermal Distortion Modeling, Analysis, and Model Validation for the JWST ISIM Structure

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope consisting of the following elements: (1) Optical telescope element (OTE) (2) Integrated science instrument module (ISIM) (3) Spacecraft (4) Sunshield The Integrated Science Instrument Module (ISIM) consists of the JWST science instruments (NIRCam, MIRI, NIRSpec), a fine guidance sensor (FGS), the ISIM Structure, and thermal and electrical subsystems. JWST's instruments are designed to work primarily in the infrared range of the electromagnetic spectrum, and the instruments and telescope operate at cryogenic temperatures (approximately 35 K for the instruments). The development and validation of a thermal distortion modeling and analysis capability for the JWST ISIM Structure was successfully completed. The modeling and analysis approach was grounded in initial constituent materials testing and benchmarked to test results at the composite bonded joint, subassembly, and fullscale flight hardware levels. Comparison of analysis predictions and test results from this series of incremental cryogenic thermal distortion tests demonstrates that the model validation goals are achieved.

Johnston, John↗

An Electrical Modeling and Thermal Analysis Toolbox for Electrified Aircraft Propulsion Simulation

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this paper is to present an overview of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will also provide some examples of EAP system modeling using EMTAT.

Mark E Bell↗

An Electrical Modeling and Thermal Analysis Toolbox for Electrified Aircraft Propulsion Simulation

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this paper is to present an overview of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will also provide some examples of EAP system modeling using EMTAT.

Mark E Bell↗

Thermal Vacuum Testing Strategy and Thermal Desktop Model Correlation for the Moon to Mars Planetary Autonomous Construction Technologies (MMPACT) Robotic Terrestrial Arm

This paper discusses the initial thermal vacuum testing of the MMPACT robotic terrestrial arm. The robotic arm is part of a construction system designed for the lunar south pole surface. The first thermal vacuum test was a risk mitigation test to ensure the arm could operate in vacuum, with all other data collection as secondary priorities. 44 thermocouples (TCs) were attached to the arm. Installation was done with additional care to account for both the extra wiring harness weight on the arm with the TC wires and increased focus on stabilizing the TC attachments to the moving components. Thermal steady state of <= 0.01°C/hour was reached for the hot set of testing conditions. This data was used to correlate the Thermal Desktop (TD) model to the test results within +/- 5°C.

Thermal analysis↗

Thermal Vacuum Testing Strategy and Thermal Desktop Model Correlation for the Moon to Mars Planetary Autonomous Construction Technologies (MMPACT) Robotic Terrestrial Arm

This paper discusses the initial thermal vacuum testing of the MMPACT robotic terrestrial arm. The robotic arm is part of a construction system designed for the lunar south pole surface. The first thermal vacuum test was a risk mitigation test to ensure the arm could operate in vacuum, with all other data collection as secondary priorities. 44 thermocouples (TCs) were attached to the arm. Installation was done with additional care to account for both the extra wiring harness weight on the arm with the TC wires and increased focus on stabilizing the TC attachments to the moving components. Thermal steady state of <= 0.01°C/hour was reached for the hot set of testing conditions. This data was used to correlate the Thermal Desktop (TD) model to the test results within +/- 5°C.

Thermal analysis↗

ADVANCED THERMAL-HYDRAULIC MODEL OF HEAT RECOVERY STEAM GENERATORS

Steam-side oxidation at elevated temperatures in heat recovery steam generators (HRSGs) can lead to overheating of local tubes, potential oxide scale exfoliation, and damage to critical equipment. Predicting the oxide growth distribution requires detailed knowledge of the distribution of tube metal temperatures. To address these challenges, a computational fluid dynamics (CFD) model of a high-pressure superheater (HPSH) was developed within the Siemens’ STAR-CCM+ CFD commercial software. The HPSH section of the steam generator was selected for modeling because of its high oxidation rates.The model development included several steps. In the first step, an oxidation model based on a parabolic oxidation relationship was implemented. The oxidation growth predicted by the model was then verified for a full-load boiler operation case. In the second step, a three-dimensional CFD model was developed to account for the thermal and flow physics involved in HRSGs. The CFD model was then verified and validated on a simplified geometry that contained six row-tubes which mimicked the tube arrangements of an HPSH section. Numerical results compared well with published experimental results. In the third step, the oxidation model was coupled to the HRSG’s CFD model, and a comparison study was performed for two cases: (a) regular finless tubes and (b) finned tubes. Preliminary results showed that the oxide thickness predicted by the case with tube fins was higher compared to that of the finless tube case, thus demonstrating the need to model the effects of the tube fins on oxide thickness.

Panicker, Nithin↗

GridLAB-D Technical Support Document: Residential Equivalent Thermal Parameter Model

GridLAB-D is a power distribution systems simulation and analysis tool developed by Pacific Northwest National Laboratory. Although GridLAB-D and its underlying residential load model has been used in a variety of power systems analyses, comprehensive documentation of the derivation of the residential house model has not been formally published. The purpose of this technical support document is to serve as a comprehensive resource for the thermal dynamics modeling and house definition implemented in GridLAB-D. It covers model derivation, parameter definitions, and implementation steps in the codebase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient thermal response of ablating bodies

A numerical study of transient thermal response of a blunt-nosed axisymmetric body made of Teflon is presented using a two-layer thermal model. It is shown that phase change and transverse heat conduction have a considerable effect on the internal temperature field. Comparison of the numerical results with experimental data shows that the single-layer thermal model does not predict the real feature of the thermal field, whereas the results of the two-layer thermal model agree reasonably well with the experiment.

Arai, N.↗

Characterization of the High-Albedo NEA 3691 Bede

Characterization of NEAs provides important inputs to models for atmospheric entry, risk assessment and mitigation. Diameter is a key parameter because diameter translates to kinetic energy in atmospheric entry. Diameters can be derived from the absolute magnitude, H(PA=0deg), and from thermal modeling of observed IR fluxes. For both methods, the albedo (pv) is important - high pv surfaces have cooler temperatures, larger diameters for a given Hmag, and shallower phase curves (larger slope parameter G). Thermal model parameters are coupled, however, so that a higher thermal inertia also results in a cooler surface temperature. Multiple parameters contribute to constraining the diameter. Observations made at multiple observing geometries can contribute to understanding the relationships between and potentially breaking some of the degeneracies between parameters. We present data and analyses on NEA 3691 Bede with the aim of best constraining the diameter and pv from a combination of thermal modeling and light curve analyses. We employ our UKIRT+Michelle mid-IR photometric observations of 3691 Bede's thermal emission at 2 phase angles (27&43 deg 2015-03-19 & 04-13), in addition to WISE data (33deg 2010-05-27, Mainzer+2011). Observing geometries differ by solar phase angles and by moderate changes in heliocentric distance (e.g., further distances produce somewhat cooler surface temperatures). With the NEATM model and for a constant IR beaming parameter (eta=constant), there is a family of solutions for (diameter, pv, G, eta) where G is the slope parameter from the H-G Relation. NEATM models employing Pravec+2012's choice of G=0.43, produce D=1.8 km and pv≈0.4, given that G=0.43 is assumed from studies of main belt asteroids (Warner+2009). We present an analysis of the light curve of 3691 Bede to constrain G from observations. We also investigate fitting thermophysical models (TPM, Rozitis+11) to constrain the coupled parameters of thermal inertia (Gamma) and surface roughness, which in turn affect diameter and pv. Surface composition can be related to pv. This study focuses on understanding and characterizing the dependency of parameters with the aim of constraining diameter, pv and thermal inertia for 3691 Bede.

Wooden, Diane H.↗

Characterization of Highly Thermally Conductive Organic Substrates for a Double-Sided Cooled Power Module

Abstract Silicon-Carbide (SiC) power devices have become a promising option for traditional Silicon (Si) due to the superior material properties. To fully take advantage of the SiC devices, a high-performance power device packaging solution is necessary. This study proposes a cost-effective double-sided cooled (DSC) 1.2 kV SiC half-bridge power module using organic epoxy-resin composite dielectric (ERCD) substrates. The high mechanical and thermal performance of the power module is achieved by the low-modulus, moderate thermal conductivity, and relatively thin (120 μm) layer of ERCD material compared with traditional metal-clad ceramic approaches. This novel organic dielectric can withstand high voltage (5 kV @ 120 μm) and operate up to 250°C continuously, which is indispensable for high power applications. The thermal modeling results show that the equivalent thermal resistance junction-to-case (Rjc_eq) of the DSC power module using dual direct bonded copper (DBC) is 17% higher than the dual ERCD configuration. Furthermore, a non-insulated DSC power module concept is proposed for maximizing thermal performance by considering thermal vias in the ERCD substrate and direct-soldered heat sink. A thought process for optimization of thermal via design is demonstrated and it shows up to 24% of improvement on thermal performance compared with the insulated DSC power module.

Double-sided cooling, epoxy-resin composite dielec↗

Application of the CINGEN program a thermal network data generator

The application of the CINGEN computer program and two of its supporting programs for the evaluation of structural and thermal performance of physical systems was described. The CINGEN program was written and implemented to avoid the duplication effort of performing a finite element approach for structural analysis and a finite differencing technique for thermal analysis, as well as the desire for a geometrical representation of the thermal model to reduce modeling errors. The program simplifies the thermal modeling process by performing all of the capacitance and conductance calculations normally done by the analyst. Each solid element is divided into five tetrahedrons, allowing the total volume to be calculated precisely. A sample problem was illustrated.

Shultz, W. E.↗

Optimal Substrate Preheating Model for Thermal Spray Deposition of Thermosets onto Polymer Matrix Composites

High velocity oxy-fuel (HVOF) sprayed, functionally graded polyimide/WC-Co composite coatings on polymer matrix composites (PMC's) are being investigated for applications in turbine engine technologies. This requires that the polyimide, used as the matrix material, be fully crosslinked during deposition in order to maximize its engineering properties. The rapid heating and cooling nature of the HVOF spray process and the high heat flux through the coating into the substrate typically do not allow sufficient time at temperature for curing of the thermoset. It was hypothesized that external substrate preheating might enhance the deposition behavior and curing reaction during the thermal spraying of polyimide thermosets. A simple analytical process model for the deposition of thermosetting polyimide onto polymer matrix composites by HVOF thermal spray technology has been developed. The model incorporates various heat transfer mechanisms and enables surface temperature profiles of the coating to be simulated, primarily as a function of substrate preheating temperature. Four cases were modeled: (i) no substrate preheating; (ii) substrates electrically preheated from the rear; (iii) substrates preheated by hot air from the front face; and (iv) substrates electrically preheated from the rear and by hot air from the front.

Ivosevic, M.↗