Global characterization of a laser-generated neutron source

Laser-driven neutron sources are routinely produced by the interaction of laser-accelerated protons with a converter. They present complementary characteristics to those of conventional accelerator-based neutron sources (e.g. short pulse durations, enabling novel applications like radiography). We present here results from an experiment aimed at performing a global characterization of the neutrons produced using the Titan laser at the Jupiter Laser Facility (Livermore, USA), where protons were accelerated from 23 $\mathrm {\mu }$ m thick plastic targets and directed onto a LiF converter to produce neutrons. For this purpose, several diagnostics were used to measure these neutron emissions, such as CR-39, activation foils, time-of-flight detectors and direct measurement of $^7{\rm Be}$ residual activity in the LiF converters. The use of these different, independently operating diagnostics enables comparison of the various measurements performed to provide a robust characterization. These measurements led to a neutron yield of $2.0\times 10^{9}$ neutrons per shot with a modest angular dependence, close to that simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Generation Method of 24-keV Monoenergetic Neutrons Using Accelerators

This paper describes a novel 24-keV monoenergetic neutron source that consists of an iron filter and a thick lithium target. The 24 keV neutrons are obtained with iron filtering of a neutron beam from the {sup 7}Li(p,n){sup 7}Be reaction near threshold energy using the 4 MV Pelletron accelerator. Neutron spectra were calculated using the NRESP-ANT simulation code. This neutron source was investigated using a {sup 3}He cylindrical proportional counter to measure the spatial distribution and neutron flux.

43 PARTICLE ACCELERATORS↗

Application of Doppler-shift attenuation method to the de-excitation {gamma} rays from the in-flight {sup 12}Be beam

The B(E2; {down_arrow}) value of the neutron-rich nucleus {sup 12}Be has been determined through the measurement of the lifetime of the first 2{sup +} state using a modified Doppler-shift attenuation method (DSAM). The first excited state was produced by the inelastic scattering of the intermediate energy {sup 12}Be beam off a thick gold target, which played two roles, to excite the beam and to decrease the velocity. The lifetime has been determined to be 2.5{+-}0.7(stat){+-}0.3(syst) ps, which gives a B(E2) value of 5.0{+-}1.3{+-}0.5 in Weisskopf units. The result shows a large quadrupole strength in the ground state transition. The B(E2) value together with the deformation length measured by proton inelastic scattering yields a neutron quadrupole matrix element two times larger than those for {sup 14}C and {sup 16}O.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental and Simulated Characterization of a Beam Shaping Assembly for Accelerator- Based Boron Neutron Capture Therapy (AB-BNCT)

In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the {sup 7}Li(p, n){sup 7}Be reaction by irradiating a thick LiF target with a 2.3 MeV proton beam delivered by the TANDAR accelerator at CNEA. The emerging neutron flux was measured by means of activation foils while the beam quality and directionality was evaluated by means of Monte Carlo simulations. The parameters show compliance with those suggested by IAEA. Finally, an improvement adding a beam collimator has been evaluated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Consideration of the mechanism of microwave emission due to material destruction

Microwave emission due to material destruction by hypervelocity impact with several kilometers per second was found at 2 and 22 GHz, and its power was calibrated in the laboratory for the first time ever. In this paper, we first summarize the experimental results in relation to the mechanism of microwave emission. We then propose three kinds of hypotheses on the mechanism, which are based on the dynamic relative motion of an atom’s nucleus and the outermost electron and lead to dipole radiation. The deduced equation represents the power dependence on the target’s thickness, which agrees well with the experimental result. The models were then numerically analyzed in consideration of the experimental data. In the most promising model, a projectile molecule flicks the nucleus out and the outermost electron is left out of the orbit of the atom. Accordingly, the material is polarized or ionized to form an impulsive dipole, which leads to microwave emission. This model is compatible with material ionization by mechanical excitation, such as rubbing and peeling, or triboelectricity. The calculated energy shows good agreement with the experimental value. On the other hand, if the outermost electron remains within the gravity field of the nucleus, the calculated and experimental results do not agree with each other.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Narrow Energy Spread Protons and Ions from High-Intensity, High-Contrast Laser Solid Target Interactions

Recent simulations show that an idealized, high intensity, short pulse laser can generate quasi-monoenergetic proton beams with energies over 100 MeV in an interaction with a thin film. However, most short pulse laser facilities with sufficient intensity have difficulty controlling the nanosecond and picosecond contrast necessary to realize such a regime. Experiments were performed to investigate proton and ion acceleration from a high contrast, short pulse laser by employing dual plasma mirrors along with a deformable mirror at the HERCULES laser facility at the Center for Ultrafast Optical Sciences, University of Michigan. Plasma mirrors were characterized, allowing a 50% throughput with an intensity contrast increase of 105. The focal spot quality was also exceptional, showing a 1.1 micron full width at half maximum (FWHM) focal diameter. Experiments were done using temporally cleaned 30 TW, 32 fs pulses to achieve an intensity of up to 10{sup 21} Wcm{sup -2} on Si{sub 3}N{sub 4} and Mylar targets with thicknesses ranging 50 nm to 13 microns. Proton beams with energy spreads below 2 MeV were observed from all thicknesses, peaking with energies up to 10.3 MeV and an energy spread of 0.8 MeV. Similar narrow energy spreads were observed for oxygen, nitrogen, and carbon at the silicon nitride thickness of 50 nm with energies up to 24 MeV with an energy spread of 3 MeV, whereas the energy spread is greatly increased at a larger thickness. Maximum energies were confirmed with CR39 track detectors, while a Thomson ion spectrometer was used to gauge the monoenergetic nature of the beam.

43 PARTICLE ACCELERATORS↗

M Sub-Shell Cross Sections For 75-300 keV Proton Impact On W, Pt And Pb

M sub-shell x-ray production cross sections from 75-300 keV proton bombardment of thick elemental targets of W, Pt, and Pb were measured and compared with ECPSSR and relativistic RPWBA-BC cross sections using different data bases of fluorescence yields, Coster-Kronig factors, and x-ray transition rates. With a few exceptions, the differences between the various data base comparisons were not significant. For different sub-shells, either ECPSSR or RPWBA-BC compared better with the measurements. In all cases, agreement with theory improved as the collision energy increased.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear Physics Experiments Below The Coulomb Barrier

In 1932, Cockcroft and Walton showed that (p,{alpha}) reactions with lithium were possible at energies near 100 keV. We report an undergraduate laboratory experiment with 90 keV protons colliding with a thick lithium target. The experiment allows students to observe the products of two reactions, to determine the product masses, and to learn techniques for deconvolving experimental spectra profiles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of a short weak prepulse on laser-triggered front-surface heavy-ion acceleration

A suppression of light-ion acceleration (from surface water contaminants) was observed when a moderate-intensity subpicosecond laser pulse was focused on a thick metal target. Simultaneously, an effective generation of high-energy multicharge ions of the target material (Fe) was experimentally observed. A numerical simulation based on the Boltzmann-Vlasov-Poisson model revealed that this is due to the very specific regime of cleaning contaminants from the target surface by the short weak prepulse preceding the main pulse by more than 10 ns and having an intensity below the surface breakdown threshold. Because this prepulse causes the contaminant layer to boil explosively, a low-density gap forms above the target surface. These conditions are consequently favorable for boosting the energy of heavy ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spot size dependence of laser accelerated protons in thin multi-ion foils

We present a numerical study of the effect of the laser spot size of a circularly polarized laser beam on the energy of quasi-monoenergetic protons in laser proton acceleration using a thin carbon-hydrogen foil. The used proton acceleration scheme is a combination of laser radiation pressure and shielded Coulomb repulsion due to the carbon ions. We observe that the spot size plays a crucial role in determining the net charge of the electron-shielded carbon ion foil and consequently the efficiency of proton acceleration. Using a laser pulse with fixed input energy and pulse length impinging on a carbon-hydrogen foil, a laser beam with smaller spot sizes can generate higher energy but fewer quasi-monoenergetic protons. We studied the scaling of the proton energy with respect to the laser spot size and obtained an optimal spot size for maximum proton energy flux. Using the optimal spot size, we can generate an 80 MeV quasi-monoenergetic proton beam containing more than 10{sup 8} protons using a laser beam with power 250 TW and energy 10 J and a target of thickness 0.15 wavelength and 49 critical density made of 90% carbon and 10% hydrogen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarimeter Development for an Electric Dipole Moment Search in a Storage Ring

The search for a charged particle EDM in a storage ring with the goal of a statistical sensitivity of 10 -29 ecenterdotcm/year requires a very sensitive polarimeter. Studies described here have shown that systematic error effects can be handled and corrected to a sensitivity better than the required 10 -6 level. The required statistical precision was shown to be attainable using a thick scattering target onto which the stored beam is slowly extracted. Models for geometric and rate systematic error effects describe the results well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

43 PARTICLE ACCELERATORS↗

Novel neutron sources at the Radiological Research Accelerator Facility

Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons. We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target. A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a proton microbeam, impinging on a thin lithium target near the threshold of the Li-7(p,n)Be-7 reaction. Lastly, this novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Skyshine from an Accelerator Facility: Dependence on Distance and Angle

Neutron skyshine from Linac Coherent Light Source II 4 GeV electron beam operation at SLAC National Accelerator Laboratory can contribute to prompt radiation exposure to the public at distances far beyond the accelerator tunnel housing. One of the shielding design requirements at SLAC is that the annual dose to a member of the public is no more than 0.05 mSv y -1 . Our work uses Monte Carlo code FLUKA to simulate the generation of neutrons from 4 GeVelectron beam losses on a thick copper target inside a generalized geometry of the Linac Coherent Light Source II Beam Transport Hall accelerator tunnel section. The effective dose from neutron skyshine was characterized as a function of both distance from the tunnel wall (up to 1 km away) and angle relative to the beam direction (between 0° and 180°). Furthermore, this new methodology for evaluating neutron skyshine dose is applicable to high-energy GeV-range electron accelerator facilities both at SLAC and elsewhere.

43 PARTICLE ACCELERATORS↗

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New measurements of the lifetimes of excited states of {sup 55}Mn below 2.7 MeV

The lifetimes of the excited states of {sup 55}Mn between 1.5 and 2.7 MeV were measured using nuclear resonance fluorescence. The absolute lifetimes of the excited levels were determined from simultaneous measurements of manganese and aluminum. In this approach, the precisely known aluminum state serves as a means to normalize the results. Our findings differ from the evaluated level lifetimes in the Evaluated Nuclear Structure Data File (ENSDF), but agree with earlier nuclear resonance fluorescence measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗