Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two Phase Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Evaluation of thermodynamic closure models for partially reacted two-phase mixture of condensed phase explosives

One of the key fundamental issues that is crucial in the continuum modeling of reactive flow phenomena is the thermodynamically consistent description of reaction mixture properties. To define the mixture properties, thermodynamic closure rules that relate the properties of the individual reaction components to the mixture properties are required. In the context of reactive two-phase modeling approaches, various strategies to define the thermodynamic closures have been adopted such as pressure temperature (PT) equilibrium between the individual reaction components, pressure (specific) volume (PV) equilibrium, etc. The choice of closure rules determines the relative distribution of specific volume and energy across the reaction components that comprise the mixture. Therefore, depending on the choice of the closure, the mixture thermodynamic behavior can vary. The present work examines the effect of different closure approaches on the thermodynamic properties of the reaction mixture. The analysis is performed for a condensed phase HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) based plastic bonded explosive (PBX) 9501 explosive using four different thermodynamic closures, viz., PT equilibrium, PV equilibrium, volume temperature (VT) equilibrium, and pressure (P) equilibrium with reactants on an isentrope. Furthermore, the relative variations in the thermodynamic properties of the mixture are analyzed and compared under both compression and expansion loading regimes. It is shown that out of the four closure models, only PT equilibrium and P equilibrium closures lead to a thermodynamically accurate description of the mixture under both compression and expansion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Accretion flow properties of MAXI J1543-564 during 2011 outburst from the TCAF solution

We derive accretion flow properties of the transient black hole candidate (BHC) MAXI J1543–564 using the RXTE data. We use the two-component advective flow (TCAF) solution to fit the data of the initial rising phase of outburst (from 2011 May 10 to 15). The 2.5–25 keV spectra are fitted using the TCAF solution fits file as a local additive table model in XSPEC. We extract physical flow parameters such as the two-component (Keplerian disk and sub-Keplerian halo) accretion rates and size and the property of the Compton cloud (post-shock region close to a black hole). Similar to other classical transient BHCs, monotonic evolution of low-frequency quasi-periodic oscillations (QPOs) is observed during the rising phase of the outburst, which is fitted with the propagating oscillatory shock (POS) model, which describes how the Compton cloud properties change from day to day. From the nature of variations of TCAF model fitted physical flow parameters and QPOs, we only found hard-intermediate and soft-intermediate spectral states during this phase of the outburst under study. We also calculated the frequency of the dominating QPOs from the TCAF model fitted shock parameters and found that they roughly match with the observed and POS model fitted values. From our spectro-temporal study of the source with TCAF and POS models, the most probable mass of the BHC is found to be 12.6–14.0 M {sub ⊙}, or 13{sub −0.4}{sup +1.0} M{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Pressure, High-Temperature Thermal Hydraulic Test Facility for Nuclear-Renewable Hybrid Energy System Studies; Facility Design Description and Status Report

A high-pressure, high-temperature water flow loop has been designed at Idaho National Laboratory (INL) for deployment in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL) within the Energy Systems Laboratory (ESL) D100 northwest high bay. This loop is the first of three thermally coupled flow loops that will comprise the Advanced Reactor Technology Integral System Test (ARTIST) facility. The ARTIST facility will ultimately include a high temperature helium loop and a liquid salt loop, in addition to the PWR loop. The high-pressure water loop will operate at Pressurized Water Reactor (PWR) conditions. It will support experimental research on nuclear-renewable hybrid energy systems as well as advanced reactor technology topics. Within DETAIL, the water flow loop will also serve as a thermal energy source, emulating a reactor system. The loop will be thermally integrated with co-located energy systems including a thermal energy transport loop, thermal energy storage system, and a 25 kW high-temperature electrolysis system for hydrogen production. DETAIL will include additional energy systems such as an integrated microgrid and renewable energy systems including solar photovoltaics. The electrically heated flow loop will be dynamically controlled to simulate nuclear fuel behavior under normal and off-normal operating conditions. DETAIL will be designed for characterization of complex system dynamics. The various components will be interfaced with Digital Real-Time Simulators for supervisory control and dynamic simulation of complete systems. The design and assembly of the high-pressure water flow loop and supporting systems has been subdivided into two Phases. Phase 1, which will be completed by the end of FY17, includes installation of cable trays and supports, electrical conduit, DI water system, drain lift station and the concrete pad for the chiller located outside of the laboratory. Phase 2 includes the detailed design and final assembly of the flow loop, supporting structures and personnel platforms, the chiller and associated piping. As of September, 2017, the final detailed design of the flow loop is complete. Funding for Phase 2 procurement, assembly, system operability checkout, shakedown testing and initial operation of the flow loop is requested for FY18.

42 ENGINEERING↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

An extended JBN method of determining unsteady-state two-phase relative permeability

Relative permeability is the reduction of permeability of porous media when subjected to multiphase flow and a key parameter in subsurface hydrology. The JBN method is a well-known method of obtaining relative permeability, which measures the overall pressure drop and the effluent phase ratio versus time during two-phase displacements. By assuming no capillary pressure or gravity, the JBN method obtains the relative permeabilities to both phases at the core outlet. Since data across a range of saturations are acquired in a relatively short time, this method is widely used. This work extends the JBN method by having (1) section-wise pressure drop measurements between the core inlet, four pressure taps on the core and the outlet, (2) local saturation measurements, and (3) local phase fluxes. With these data, the extended JBN method can determine relative permeabilities to both phases at each pressure tap of the core (not just at the core outlet). The JBN extension is shown using a data set where CO 2 invades a brine-filled core. From this it is found that the advantages of the extended JBN method over the regular JBN method are: (1) four times more data are obtained, and (2) data are more accurate because the capillary end effect is experimentally avoided. Avoiding the end effect results in tripling the saturation range, and obtaining relative permeabilities that are consistent with steady-state measurements and roughly 40% higher than those from the regular JBN method.

54 ENVIRONMENTAL SCIENCES↗

Combustion of 10–100 μm aluminum droplets in detonation products gases

Here we describe a two-phase model of combustion effects in aluminized high explosive (HE) charges. It is based on: (i) a Gas Dynamic Model of the expansion of the detonation product gases and their turbulent combustion with air; and (ii) a Heterogeneous Continuum Model of aluminum (Al) droplets and their combustion with the detonation product gases. Initial conditions are based on an analytical similarity solution for a cylindrical Chapman-Jouguet (CJ) detonation propagating at the CJ detonation velocity. The CJ jump conditions are computed at the thermodynamic equilibrium state by the Cheetah code, assuming the Al droplets are inert. We assume that the Al is 10 % of the charge mass and occurs as droplets at the CJ state. Different initial droplet diameters, ranging from 10 to 100 microns, are studied. A hydrodynamic combustion model based on large Damköhler numbers is employed in this study, -3σ(1 + 0.276 $\sqrt{Re}$)/($Kd^2_w$). It has a square-root dependence on the Reynolds number (Re) and inversed-squared dependence on the droplet diameter (d w ). The burnout time (t B ) of the Al droplets has a three-halves dependence on the droplet diameter, t B ~ ($d^0_w$) 3/2 . After burnout, the detonation products act as detonation products of the HE charge with active Al. They turbulently mix with air and form a combustion layer on the outer edge of the fireball. Details of the two-phase model, initial conditions and evolution of the flow field will be described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Converting polyisoprene rubbers into bio-jet fuels via a cascade hydropyrolysis and vapor-phase hydrogenation process

Producing alternative drop-in bio-jet fuels from biomass provides a promising approach to achieve carbon neutrality. Here, to upcycle biomass-based polyisoprene rubbers into jet-fuel range C 10 cycloalkane, we proposed a cascade hydropyrolysis and vapor-phase hydrogenation process in a flow-through two-stage pressurized fixed-bed reactor. The hydropyrolysis temperature in the first stage is of vital importance for the formation of primary limonene intermediate in the non-catalytic degradation of polyisoprene rubbers, and a reaction temperature of 460 °C maximized limonene yield to 588.6 mg/g for natural rubber and 546.2 mg/g for Eucommia rubber. Over a Pt/C catalyst loaded in the second stage, the limonene intermediate produced from the first-stage reactor can be completely hydrogenated, giving a 642.7 mg/g yield of jet-fuel range C 10 cycloalkane with 83.6% selectivity. The depolymerization mechanism of polyisoprene rubbers was thoroughly studied, and a competitive reaction between limonene hydrogenation and limonene dehydrogenation was observed. This is the first report on producing C 10 cycloalkane from natural rubbers via a cascade hydropyrolysis and hydrogenation process, providing a promising strategy to upcycle polyisoprene rubbers into bio-jet fuels.

30 DIRECT ENERGY CONVERSION↗

An Incompressible, Depth-Averaged Lattice Boltzmann Method for Liquid Flow in Microfluidic Devices with Variable Aperture

Two-dimensional (2D) pore-scale models have successfully simulated microfluidic experiments of aqueous-phase flow with mixing-controlled reactions in devices with small aperture. A standard 2D model is not generally appropriate when the presence of mineral precipitate or biomass creates complex and irregular three-dimensional (3D) pore geometries. We modify the 2D lattice Boltzmann method (LBM) to incorporate viscous drag from the top and bottom microfluidic device (micromodel) surfaces, typically excluded in a 2D model. Viscous drag from these surfaces can be approximated by uniformly scaling a steady-state 2D velocity field at low Reynolds number. We demonstrate increased accuracy by approximating the viscous drag with an analytically-derived body force which assumes a local parabolic velocity profile across the micromodel depth. Accuracy of the generated 2D velocity field and simulation permeability have not been evaluated in geometries with variable aperture. We obtain permeabilities within approximately 10% error and accurate streamlines from the proposed 2D method relative to results obtained from 3D simulations. Additionally, the proposed method requires a CPU run time approximately 40 times less than a standard 3D method, representing a significant computational benefit for permeability calculations.

58 GEOSCIENCES↗

Comparison of electrical and optical characteristics in gas-phase and gas-liquid phase discharges

This paper presents an AC-excited argon discharge generated using a gas-liquid (two-phase) hybrid plasma reactor, which mainly consists of a powered needle electrode enclosed in a conical quartz tube and grounded deionized water electrode. The discharges in the gas-phase, as well as in the two-phase, exhibit two discharge modes, i.e., the low current glow-like diffuse mode and the high current streamer-like constrict mode, with a mode transition, which exhibits a negative resistance of the discharges. The optical emission spectral analysis shows that the stronger diffusion of the water vapor into the discharge region in the two-phase discharges boosts up the generation of OH (A–X) radicals, and consequently, leads to a higher rotational temperature in the water-phase plasma plume than that of the gas-phase discharges. Both the increase of the power input and the decrease of the argon flow rate result in the increase of the rotational temperature in the plasma plume of the water-phase discharge. The stable two-phase discharges with a long plasma plume in the water-phase under a low power input and gas flow rate may show a promising prospect for the degradation of organic pollutants, e.g., printing and dyeing wastewater, in the field of environmental protection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of rotating mode behavior in BWR out-of-phase limit cycle oscillations – Part 2: TRACE/PARCS model and physical explanation

Previous neutronic/thermal-hydraulic (TH) coupled numerical simulations using full-core TRACE/PARCS and SIMULATE-3K boiling water reactor (BWR) models have shown evidence of a specific “rotating mode” behavior (steady rotation of the symmetry line, i.e. constant phase shift of approximately 90° between the first two azimuthal modes) in BWR out-of-phase limit cycle oscillations, regardless of initial conditions and even if the first two azimuthal modes have different natural frequencies. This suggests a nonlinear coupling between these modes; otherwise, the phase shift between these modes would change at a constant rate during the limit cycle. The previous paper (“Part 1”) presented a series of results to examine this rotating behavior with a reduced-order model. The goal of the present study is to provide additional analyses of the predicted rotating mode behavior using higher-fidelity numerical modeling, as well as a physical explanation for why this mode is favored over side-to-side or other oscillatory behaviors from a TH perspective. Results are presented using TRACE and TRACE/PARCS for a small number of parallel channels, which confirmed that the conclusions developed from the reduced-order model remain applicable when applying a full two-fluid, six-equation, finite-volume modeling approach. From these results, a physical explanation has been put forth to explain why the rotating symmetry line behavior is preferred from a TH standpoint, demonstrating that predominantly out-of-phase unstable systems are most unstable when the variation in the total inlet flow rate is minimized (which minimizes the effective single-phase to two-phase pressure drop ratio) and that the rotating mode is the most successful in minimizing this total flow rate variation as compared with the side-to-side case or any other oscillation pattern. The conclusion is that the rotating mode will be favored for any out-of-phase unstable system of parallel channels with no neutronic feedback or relatively weak neutronic feedback. Here, previous analyses have indicated that systems with sufficiently strong neutronic coupling may favor the side-to-side oscillation mode over the rotating mode; this topic is left as a subject of future investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Transfer and Pressure Drop Characteristics of Water Flow Boiling in Internally Enhanced Tubes

Flow boiling is a critical process for many thermal conversion processes such as HVAC&R, water heating, power generation and desalination applications. The major goal of this paper is to enhance the in-tube heat transfer for flow boiling of water and further improve the efficiency of the boiler. This paper presents an experimental investigation of the heat transfer and pressure drop characteristics for water under forced convection and boiling conditions inside both smooth and enhanced tubes. The results in the smooth copper tube are compared with several correlations and used as a baseline. The two-phase heat transfer and pressure drop performance of the water flow boiling in the internally enhanced tube is investigated, and the influence of internal surface pattern on the thermal characteristics is discussed. The relations of the heat transfer coefficient with mass flux, heat flux and vapor quality are analyzed according to the results.

Yang, Cheng-Min↗

Microstructural, Oxidation, and Mechanical Behavior of NbTi-Based Refractory Alloys with 5 to 10 Pct Co, Cr, and Ni Additions

NbTi-based refractory alloys with additions of Co, Cr, and Ni represent an interesting medium-entropy alloy system with potential for protective oxide film formation, high strength, and ductility. This study investigates the microstructural evolution, oxidation behavior, and mechanical properties of NbTi-based alloys containing 5 to 10 at. pct Co, Cr, and Ni. CALPHAD predictions suggest that this composition range can be heat treated to obtain a predominantly body-centered cubic matrix phase. Mechanical properties, including microhardness, yield strength, maximum strength, and specific strength are evaluated through isothermal compression tests conducted between room temperature and 800 °C. The oxidation kinetics of these alloys are assessed through discontinuous oxidation tests. Parabolic oxidation kinetics were observed for NbTi–10Ni and NbTi–5Co, while linear oxidation kinetics were found for NbTi–10Cr and NbTi–10(CoCrNi). Microstructures and oxide layers are characterized using X-ray diffraction, electron backscatter diffraction, energy-dispersive X-ray spectroscopy, and scanning electron microscopy. All alloys exhibit significant mechanical softening between room temperature and 800 °C, with elastic-perfectly plastic flow observed at 800 °C. The addition of 10 pct Cr to NbTi resulted in two BCC phases up to 1050 °C, conflicting with CALPHAD predictions of a single-phase solid solution at this temperature, and resulting in higher flow stress at 800 °C. NbTi–10(CoCrNi) exhibited the lowest flow stress at 800 °C despite having more ‘cocktail effect’ potential and insufficient molar fractions of Co, Cr, or Ni to form a desirable protective oxide film.

36 MATERIALS SCIENCE↗

A Two-length Scale Turbulence Model for Single-phase Multi-fluid Mixing

A two-length scale, second moment turbulence model (Reynolds averaged Navier-Stokes, RANS) is proposed to capture a wide variety of single-phase flows, spanning from incompressible flows with single fluids and mixtures of different density fluids (variable density flows) to flows over shock waves. The two-length scale model was developed to address an inconsistency present in the single-length scale models, e.g. the inability to match both variable density homogeneous Rayleigh-Taylor turbulence and Rayleigh-Taylor induced turbulence, as well as the inability to match both homogeneous shear and free shear flows. The two-length scale model focuses on separating the decay and transport length scales, as the two physical processes are generally different in inhomogeneous turbulence. This allows reasonable comparisons with statistics and spreading rates over such a wide range of turbulent flows using a common set of model coefficients. The specific canonical flows considered for calibrating the model include homogeneous shear, single-phase incompressible shear driven turbulence, variable density homogeneous Rayleigh-Taylor turbulence, Rayleigh-Taylor induced turbulence, and shocked isotropic turbulence. The second moment model shows to compare reasonably well with direct numerical simulations (DNS), experiments, and theory in most cases. The model was then applied to variable density shear layer and shock tube data and shows to be in reasonable agreement with DNS and experiments. Additionally, the importance of using DNS to calibrate and assess RANS type turbulence models is highlighted.

04 OIL SHALES AND TAR SANDS↗

Impact of Three-Phase Relative Permeability and Hysteresis Models on Forecasts of Storage Associated With CO 2 -EOR

Geological CO 2 sequestration in conjunction with enhanced oil recovery (CO 2 -EOR) includes complex multiphase flow processes compared to CO 2 storage in deep saline aquifers. Two of the most critical factors affecting multiphase flow in CO 2 -EOR are three-phase relative permeability and associated hysteresis, both of which are difficult to measure and are usually represented by numerical interpolation models. The purpose of this research is to improve understanding of (1) the relative impacts of different three-phase relative permeability models and hysteresis models on CO 2 trapping mechanisms, and (2) uncertainty associated with these two factors. Four different three-phase relative permeability models and three hysteresis models were applied to simulations of an active CO 2 -EOR site, the SACROC unit located in western Texas. To eliminate potential bias of deterministic parameters, we utilized a sequential Gaussian simulation technique to generate 50 realizations to describe heterogeneity of porosity and permeability, based on data obtained from well logs and seismic survey. Simulation results of forecasted CO 2 storage suggested that (1) the choice of three-phase relative permeability model and hysteresis model led to noticeable impacts on forecasted CO 2 sequestration capacity; (2) impacts of three-phase relative permeability models and hysteresis models on CO 2 trapping are small during the CO 2 -EOR injection period, and increase during the post-EOR CO 2 injection period; (3) the specific choice of hysteresis model is more important relative to the choice of three-phase relative permeability model; and (4) using the recommended three-phase WAG (Water-Alternating-Gas) hysteresis model may increase the impact of three-phase relative permeability models and uncertainty due to heterogeneity.

42 ENGINEERING↗