Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility and Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Novel Hourly-Resolved Global Cloud Property Composite from Operational Satellites Imagers

Numerous applications in satellite remote sensing of surface properties, atmospheric state, composition, and radiation require accurate knowledge of the location and characteristics of clouds. Operational satellite imager radiances are valuable for cloud detection and for deriving many different physical parameters that can be used for a variety of weather, aviation, and energy applications. The NASA Satellite ClOud and Radiation Property retrieval System (SatCORPS) applies a suite of algorithms to meteorological satellite data to provide cloud properties, radiative fluxes and other parameters on a global scale. This paper describes a new global high-resolution dataset of cloud properties made available for community use that is constructed from analyses of a constellation of meteorological satellite imagers. Data taken from Meteosat-8/9 and -11, Himawari-8/9, GOES-16, and -17/-18, Aqua, Terra, Suomi-NPP and NOAA-20 are processed and composited on a 3-km grid to provide hourly global coverage. A historical multi-year dataset is available to serve various needs including modeling challenges related to cloud evaluations and parameterizations. Near real-time data products are also currently available between 60N and 60S. Efforts are underway to operationalize polar orbiting satellite cloud detection methods for low-latency applications over polar regions. The cloud detection and retrieval algorithms have been developed over many years to support NASA weather and climate programs such as the Clouds and Earth’s Radiant Energy System (CERES). To improve the utility of the data products, machine learning and other innovative methods are applied in various ways to help minimize data product uncertainties under the most challenging conditions and to improve their consistency at all times of day. A brief description of the methods highlighting the unique aspects of the SatCORPS data products will be presented along with information on their status and availability.

SatCORPS↗

Coupling of the Electricity and Transportation Sectors - Part I: Sector Overviews

“Sector coupling” is a concept that addresses potential designs for the future power industry. Traditionally, the energy sectors, i.e., electricity supply, transport, and industry, have functioned largely independently from one another. Thus, the concept of sector coupling means that the electricity sector would become the central pillar of the energy system, supplying the other sectors – transportation and industry – with energy in various ways, a scheme described by the term “Power-to-X”. This report delves into the ambitious goal set by the United States to achieve net-zero emissions by 2050, with a pivotal milestone of making half of all passenger vehicles sold in America zero-emission by 2030. Central to achieving this objective is the electrification of the transportation sector, resulting in complex interactions between this sector and the electric industry. As electric vehicles become more prevalent, a shift in the dependency on electricity for vehicle charging emerges, alongside a reduction in the electricity demand associated with maintaining the fossil fuel supply chain. Both the electricity and fossil fuel have been identified as critical infrastructure sectors, the transportation sector's historical reliance on fossil fuels, and the mature supply chain supporting them are explored. This study emphasizes the existing sectoral coupling between the electric energy and transportation sectors, extending beyond vehicle charging to essential operations at refineries, pipeline facilities, storage, and fuel extraction. Recognizing the critical dependency of fossil fuel supply chain operations on the electric sector, this research underscores the need for a comprehensive view of the evolving dynamics between the transportation and electric sectors. This study has been split into two segments, Part-I provides an overview of the existing fossil fuel supply chain architecture and the electrical sector. We provide an in-depth analysis of the grid-transportation sectoral coupling, its interactions, the vulnerabilities and essential take-aways that would help us to address them and apply towards an electrified transportation sector in the future. We engaged with stakeholders to understand their expectations in enabling an electrified transportation. We accumulate the understandings from the current fossil fuel-based system in developing a risk matrix, by identifying all the threats and vulnerabilities and how would they apply to both the current and future transportation systems in Part-II of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Well‐to‐wheels analysis of greenhouse gas emissions for passenger vehicles in Middle East and North Africa

Battery electric vehicles (BEVs) are widely considered a pathway to achieve low carbon mobility. BEVs emit zero emissions from the tailpipe, but their life cycle carbon reduction compared to gasoline vehicles varies based on primary energy sources, electricity generation, and use efficiency. The Middle East and North Africa (MENA) region is an area rich in fossil fuels, meriting a detailed comparison between the emissions from BEV and other powertrains. We developed a MENA‐specific life cycle model that estimates well‐to‐wheel (WTW) greenhouse gas (GHG) emissions from passenger transport with internal combustion engine vehicles (ICEVs), hybrid electric vehicles (HEVs), plug‐in hybrid electric vehicles, and BEVs. MENA's average WTW GHG emissions for all supply chain steps including combustion emissions from vehicle operation are 767 g/kWh and 84 g CO 2 eq/MJ for electricity and gasoline, respectively, but are highly variable due to heterogeneity in upstream supply chains. The use of hybrid gasoline ICEVs provides the largest emission reduction opportunity for existing vehicle fleets in 9 of the 16 MENA countries. For these nine countries, replacing gasoline ICEVs with HEVs could, on average, reduce country‐level life cycle GHG emissions by 47%. There is a similar emission reduction opportunity for 14 of the 16 MENA countries when normalizing vehicle efficiencies irrespective of the powertrain shares and other trends in existing vehicle fleets. Future scenario analysis shows that BEVs would have the lowest WTW GHG emissions among all powertrains in most MENA countries only if significantly reduced electricity transmission losses and cleaner grid mix are realized, although a high cost of infrastructure developments is expected.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status of the NEXT Ion Thruster Long-Duration Test After 10,100 hr and 207 kg Demonstrated

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art in ion propulsion to provide future NASA science missions with enhanced mission capabilities at a low total development cost. As part of a comprehensive thruster service life assessment utilizing both testing and analyses, a Long-Duration Test (LDT) was initiated to validate and qualify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the mission-derived throughput requirement of 300 kg. This wear test is being conducted with a modified, flight-representative NEXT engineering model ion thruster, designated EM3. As of June 21, 2007, the thruster has accumulated 10,100 hr of operation at the thruster full-input-power of 6.9 kW with 3.52 A beam current and 1800 V beam power supply voltage. The thruster has processed 207 kg of xenon and demonstrated a total impulse of 8.5 106 N-s; the highest total impulse ever demonstrated by an ion thruster in the history of space propulsion. Thruster performance tests are conducted periodically over the entire NEXT throttle table with input power ranging 0.5 to 6.9 kW. Overall ion thruster performance parameters including thrust, input power, specific impulse, and thruster efficiency have been nominal with little variation to date. Lifetime-limiting component erosion rates have been consistent with the NEXT service life assessment, which predicts the earliest failure sometime after 750 kg of xenon propellant throughput; well beyond the mission-derived lifetime requirement. The NEXT wear test data confirm that the erosion of the discharge keeper orifice, enlarging of nominal-current-density accelerator grid aperture cusps, and the decrease in cold grid-gap observed during the NSTAR Extended Life Test have been mitigated. This paper presents the status of the NEXT LDT to date.

Herman, Daniel A.↗

Terrain Portrayal for Head-Down Displays Flight Test

The Synthetic Vision Systems General Aviation (SVS-GA) element of NASA's Aviation Safety Program is developing technology to eliminate low visibility induced General Aviation (GA) accidents through the application of synthetic vision techniques. SVS displays present computer generated 3-dimensional imagery of the surrounding terrain to greatly enhance pilot's situation awareness (SA), reducing or eliminating Controlled Flight into Terrain (CFIT), as well as Low-Visibility Loss of Control (LVLOC) accidents. In addition to substantial safety benefits, SVS displays have many potential operational benefits that can lead to flight in instrument meteorological conditions (IMC) resembling those conducted in visual meteorological conditions (VMC). Potential benefits could include lower landing minimums, more approach options, reduced training time, etc. SVS conducted research will develop display concepts providing the pilot with an unobstructed view of the outside terrain, regardless of weather conditions and time of day. A critical component of SVS displays is the appropriate presentation of terrain to the pilot. The relationship between the realism of the terrain presentation and resulting enhancements of pilot SA and pilot performance has been largely undefined. Comprised of coordinated simulation and flight test efforts, the terrain portrayal for head-down displays (TP-HDD) test series examined the effects of two primary elements of terrain portrayal: variations of digital elevation model (DEM) resolution and terrain texturing. Variations in DEM resolution ranged from sparsely spaced (30 arc-sec/2,953ft) to very closely spaced data (1 arc-sec/98 ft). Variations in texture involved three primary methods: constant color, elevation-based generic, and photo-realistic, along with a secondary depth cue enhancer in the form of a fishnet grid overlay. The TP-HDD test series was designed to provide comprehensive data to enable design trades to optimize all SVS applications, as well as develop requirements and recommendations to facilitate the implementation and certification of SVS displays. The TP-HDD flight experiment utilized the NASA LaRC Cessna 206 Stationaire and evaluated eight terrain portrayal concepts in an effort to confirm and extend results from the previously conducted TP-HDD simulation experiment. A total of 15 evaluation pilots, of various qualifications, accumulated over 75 hours of dedicated research flight time at Newport News (PHF) and Roanoke (ROA), VA, airports from August through October, 2002. This report will present results from the portion of testing conducted at Roanoke, VA.

Hughes, Monica F.↗

Transforming the Process Industries through Electrification: Challenges and Opportunities

For the more than 70 years, the process industries have provided essential fuels and materials for global growth. Increased manufacturing production comes with substantial environmental impact. Reducing environmental impact through process electrification, carbon capture, and other emerging technologies would require large changes throughout the process industries. We review opportunities and challenges related to electrification, focusing on technical, operational, and economic considerations. Here, we conclude that electrification could completely eliminate scope 1 CO 2 emissions, increase product quality, and reduce the equipment size and cost. On the other hand, it calls for a significant expansion of power generation capacity, as well as new paradigms for process design and operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status of the NEXT Long-Duration Test After 23,300 Hours of Operation

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art in ion propulsion to provide future NASA science missions with enhanced mission capabilities at a low total development cost. As part of a comprehensive thruster service life assessment utilizing both testing and analyses, a Long-Duration Test (LDT) was initiated in June 2005, to verify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the anticipated throughput requirement of 300 kg per thruster from mission analyses. The LDT is being conducted with a modified, flight-representative NEXT engineering model ion thruster, designated EM3. As of July 2009, the thruster has accumulated 23,300 h of operation with extensive durations at the following input powers: 6.9, 4.7, 1.1, and 0.5 kW. The thruster has processed 427 kg of xenon surpassing the NSTAR propellant throughput demonstrated during the extended life testing of the Deep Space 1 flight spare ion thruster and approaching the NEXT development qualification throughput goal. The NEXT LDT has demonstrated a total impulse of 16.0 10(exp 6) N/s; the highest total impulse ever demonstrated by an ion thruster. Thruster performance tests are conducted periodically over the entire NEXT throttle table with input power ranging 0.5 to 6.9 kW. Thruster performance parameters including thrust, input power, specific impulse, and thruster efficiency have been nominal with little variation to date. The NSTAR first-failure mode, accelerator aperture erosion leading to electron backstreaming, has been mitigated in the NEXT design. The severe NSTAR discharge cathode assembly erosion has been mitigated by a graphite keeper in the NEXT thruster. Tracking of the NEXT first failure mode, charge-exchange ion impingement on the accelerator grid causing hexagonal groove erosion, is consistent with model predictions and indicates thruster life greater than or equal to 750 kg throughput. This paper presents the status, performance data, and wear characteristics of the NEXT LDT to date.

Herman, Daniel A.↗

FY25 Electric Grid Security Annual Report

Sandia’s Electric Grid Security program advances a national vision of energy dominance and accessibility, while applying our national security -emphasis on ensuring of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY25 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • New open-source analytical tools for systems -level planning and optimization, including significant advances to the QuESt analytical environment; • Further advancement of artificial intelligence and machine learning to enhanced grid operations and planning as we rise to the challenge of new large loads; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by several offices within the U.S. Department of Energy (USDOE), including the Office of Electricity (OE); Cybersecurity, Energy Security, and Emergency Response (CESER); former offices such as the Office of Energy Efficiency and Renewable Energy (EERE), the Grid Deployment Office (GDO), the Office of Clean Energy Demonstrations (OCED), and other key programs at USDOE. As we continue to state in these annual reports, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

NEXT Long-Duration Test After 11,570 h and 237 kg of Xenon Processed

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art in ion propulsion to provide future NASA science missions with enhanced mission capabilities at a low total development cost. As part of a comprehensive thruster service life assessment utilizing both testing and analyses, a Long-Duration Test (LDT) was initiated to validate and qualify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the mission-derived throughput requirement of 300 kg. This wear test is being conducted with a modified, flight-representative NEXT engineering model ion thruster, designated EM3. As of September 1, 2007, the thruster has accumulated 11,570 h of operation primarily at the thruster full-input-power of 6.9 kW with 3.52 A beam current and 1800 V beam power supply voltage. The thruster has processed 237 kg of xenon surpassing the NSTAR propellant throughput demonstrated during the extended life testing of the Deep Space 1 (DS1) flight spare. The NEXT LDT has demonstrated a total impulse of 9.78 10(exp 6) N(dot)s; the highest total impulse ever demonstrated by an ion thruster. Thruster performance tests are conducted periodically over the entire NEXT throttle table with input power ranging 0.5 to 6.9 kW. Thruster performance parameters including thrust, input power, specific impulse, and thruster efficiency have been nominal with little variation to date. Lifetime-limiting component erosion rates have been consistent with the NEXT service life assessment, which predicts the earliest failure sometime after 750 kg of xenon propellant throughput; well beyond the mission-derived lifetime requirement. The NEXT wear test data confirm that the erosion of the discharge keeper orifice, enlarging of nominal-current-density accelerator grid aperture cusps at full-power, and the decrease in cold grid-gap observed during NSTAR wear testing have been mitigated in the NEXT design. NEXT grid-gap data indicate a hot grid-gap at full-power that is 60 percent of the nominal cold grid-gap. This paper presents the status of the NEXT LDT to date with emphasis on comparison to the NSTAR extended life test results.

Soulas, George C.↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Urban Air Mobility Network and Vehicle Type - Modeling and Assessment

This paper describes exploratory modeling of an on-demand urban air mobility (UAM) network and sizing of vehicles to operate within that network. UAM seeks to improve the movement of goods and people around a metropolitan area by utilizing the airspace for transport. Aircraft sizing and overall network performance results are presented that include comparisons of battery-electric and various hybrid-electric vehicles that are fueled with diesel, jet fuel, compressed natural gas, and liquefied natural gas (LNG). Hybrid-electric propulsion systems consisting of internal combustion engine-generators, turbine-generators, and solid oxide fuel cells are explored. Ultimately, the "performance" of the UAM network over a day for each of the different vehicle types, propulsion systems, and stored energy sources is described in four parameters: 1) the average cost per seat-kilometer, which considers the costs of the energy/fuel, vehicle acquisition, insurance, maintenance, pilot, and battery replacement costs, 2) carbon dioxide emission rates associated with vehicle operations, 3) the average passenger wait time, and 4) the average load factor, i.e., the total number of seats filled with paying passengers divided by the total number of available seats. Results indicate that the "dispatch model," which determines when and where aircraft are flown around the UAM network, is critical in determining the overall network performance. This is due to the often-conflicting desires to allow passengers to depart with minimal wait time while still maintaining a high load factor to reduce operating costs. Additionally, regardless of the dispatch model, hybrid-electric aircraft powered by internal combustion engines fueled with diesel or LNG are consistently the lowest cost per seat-kilometer. Battery-electric and future technology LNG/solid oxide fuel cell aircraft produce the lowest emissions (assuming the California grid) with LNG-fueled internal combustion engine-powered hybrids producing only slightly more carbon dioxide.

Assessment↗

Advanced Coating Compositions and Microstructures to Improve Uptime and Operational Flexibility in Cyclic, Low-Load Thermal Utility Plants

GE, the University of Tennessee, and Oak Ridge National Laboratory collaborated from 2020 to 2023 developing two key technologies for improving the viability of fuel switching and load following in thermal utility plants: a) cost-effective weld overlay compositions for boiler tubing b) cathodic arc coatings that deliver improvements in both erosion resistance and oxidation resistance in high temperature steam for HP turbine blades The team worked through a robust, logical project map to de-risk these two technologies and advance them from TRL 3 to TRL 6. For the cost-effective weld overlay, the team developed a ferritic filler material which was fabricated at a vendor for 18% the average market cost of Inconel 625 wire, had a corrosion rate 3x lower in conditions simulating a biomass-fired superheater and 10x lower in conditions simulating a coal-fired superheater, and was fabricated into prototype overlaid tubing that passed ASME requirements including transverse bending, dye penetrant inspection, and ASTM G-76 evaluation. For the cathodic arc coatings applied to steam turbine blades, the team developed a novel composition that was successfully transferred to a qualified vendor. The vendor was able to produce coated prototypes with 4x the as-deposited erosion resistance and 10.4x the post-steam-exposure erosion resistance of the TiN coating the vendor currently applies on GE steam turbine components, without significantly increasing process cost. These coated prototypes also passed a GE inspection and showed favorable performance in high temperature erosion, nanoindentation, sliding wear, scratch adhesion, and high cycle fatigue testing. If successfully deployed by GE, it is anticipated that the technologies will enable the following: • 25%-50% increase in time between outages for both boilers and HP turbines. • 50% decrease in cost for weld overlay on a per foot basis relative to todays NiCr alloys. • Adequate oxidation resistance and erosion for HP turbine inlet steam at >620°C and >220 bar. • No need for changes in component supply chain or any notable Capital Expenditures. 5 Decreasing component cost, increasing performance, and extending time between outages represent direct value propositions to GE and their customers. For the American consumer, these objectives translate into increased grid reliability (fewer unexpected outages), decreased Levelized Cost of Electricity, and improved environmental health (low-loading/load following to accelerate penetration of renewables). The results also have implications for wear resistant tooling, wire arc additive manufacturing, more durable components for syngas cleanup, and deployment of more efficient thermochemical pathways for carbon negative fuel production

09 BIOMASS FUELS↗