Search NASA⌕ Search

SEARCH · Search NASA

Results for “absorbed power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Atomic Structure, Dynamics, Changes in Chemical Bonding and Semiconductor-Metal Transition in Sb 2 Se 3 : A Remarkable Material for Quantum Networks and Energy Applications

Antimony sesquiselenide has become an outstanding functional material for photovoltaics, energy storage and transformation, memory and photonic applications. Sb 2 Se 3 is one of the most successful emerging solar light absorbers and has also been identified as a highly promising ultralow-loss phase-change material (PCM) for next-generation coherent nanophotonic processors, photonic tensor cores, quantum and neuromorphic networks. Unlike benchmark telluride PCMs, Sb 2 Se 3 features a quasi-one-dimensional (1D) crystalline structure consisting of (Sb 4 Se 6 ) ∞ ribbons, lacks the typical PCM chemical bonding, and undergoes an extended semiconductor-metal transition above the melting point. Consequently, the origin of high optical contrast between crystalline (SET) and amorphous (RESET) logic states remains elusive and presents a significant challenge. Using high-energy X-ray diffraction and Raman spectroscopy over a wide temperature range, supported by first-principles simulations and complemented by thermal, optical and electrical measurements, as well as by 121 Sb-Mossbauer spectroscopy, the quasi-1D network of orthorhombic antimony sesquiselenide was found to undergo significant evolution in amorphous and supercooled Sb 2 Se 3 , leading to lower coordination, shorter interatomic distances and a higher p-electron density on antimony, indicating changes in chemical bonding. The observed novel Sb 2 Se 3 nanocrystalline polymorph, characterized by trigonal antimony coordination and more isolated Sb-Se ribbons, could help reduce multiple trapping defect states in the bandgap, which are typical of orthorhombic Sb 2 Se 3 , thereby enhancing the power-conversion efficiency of photovoltaic devices. Semimetallic and metallic liquid Sb 2 Se 3 exhibit a gradual transformation into a denser 2D and/or 3D network with higher antimony coordination. Localized electron states in the pseudogap are becoming extended, leading to an increase in electronic conductivity σ following the relationship σ ∝ N(E F ) 2 . Liquid Sb 2 Se 3 also appears to be strongly fragile, with a nonmonotonic change in viscosity and higher atomic mobility in the metallic liquid. Furthermore, these results explain extraordinary functionalities of Sb 2 Se 3 for photonic and energy applications.

antimony↗

Hydrogen from Sunlight and Water: A Side-by-Side Comparison between Photoelectrochemical and Solar Thermochemical Water-Splitting

Photoelectrochemical (PEC) and solar thermochemical (STCH) water-splitting represent two promising pathways for direct solar hydrogen generation. PEC water-splitting integrates multiple functional materials and utilizes energetic electrons and holes generated from sunlight to produce hydrogen and oxygen in two half-reactions, while STCH water-splitting couples a series of consecutive chemical reactions and uses absorbed heat from sunlight to generate hydrogen and oxygen in two full reactions. In this Focus Review, the basic operating principles, sunlight utilization, device architecture, reactor design, instantaneous and annually averaged solar-to-hydrogen (STH) conversion efficiency, and the operating conditions and constraints of both pathways are compared. A side-by-side comparison addresses some common sources of confusion and misinterpretation, especially in the evaluation of STH conversion efficiencies, and reveals distinct features and challenges in both PEC and STCH technologies. Furthermore, this Focus Review also addresses materials and device challenges in PEC and STCH for cost-competitive hydrogen generation.

08 HYDROGEN↗

Pulsed studies of intervalley transfer in Al 0.35 In 0.65 As: A paradigm for valley photovoltaics

Al 0.35 In 0.65 As is a direct semiconductor whose multivalley conduction-band structure has been proposed for use in so-called valley photovoltaics. In such hot-carrier solar cells, energetic (hot) photocarriers are stored in satellite valleys away from the Γ point, allowing them to be extracted prior to thermalization and to thereby increase power-conversion efficiency. While prior theoretical work has highlighted the potential of Al 0.35 In 0.65 As—a widely used barrier material in electronic and optoelectronic devices, for use in valley photovoltaics—surprisingly little is known about its electrical properties, especially how these are impacted by the application of high fields. In this work, we therefore undertake a detailed characterization of the electrical properties of Te-doped ($\textit{n}$-type) Al 0.35 In 0.65 As, over wide ranges of temperature (3–400 K) and electric field (<50 kV/cm). Using pulsed measurements to suppress the influence of Joule heating, we reveal the presence of clear negative-differential conductance in the current-voltage characteristics of the films, suggestive of the intervalley transfer of hot electrons. This conclusion is supported by the results of ensemble Monte Carlo simulations of the hot-carrier action, which confirm the connection of the observed negative-differential conductance to hot-electron transfer from the conduction-band (Γ) minimum, to the side valleys at the $\textit{L}$ point. Further, the quantitative features of the experimentally determined velocity-field curves are found to be in good agreement with the results of these calculations, providing further confidence in the role of the implied intervalley transfer mechanism. Overall, these results confirm the excellent potential of Al 0.35 In 0.65 As for use as the absorber material in hot-carrier solar cell technology.

36 MATERIALS SCIENCE↗

A high-temperature heat flux sensor using the transverse Seebeck effect in elemental rhenium

Heat flux sensors compatible with hot environments are critical to advance aerospace, materials, and energy generation technologies that cope with extreme thermal conditions. In this work, we report on the development and characterization of a high-temperature heat flux sensor using the transverse Seebeck effect in rhenium single crystals. The sensor leverages refractory alloys and ceramics compatible with temperatures exceeding 1000 °C. The heat flux sensor was characterized from room temperature to 500 °C using a temperature-controlled calibration facility. At constant temperature, the sensor’s voltage output is linear with respect to the absorbed heat flux. The responsivity of the sensor varies with temperature, from 1.3 μV/(W/cm 2 ) at room temperature to −3.2 μV/(W/cm 2 ) at 500 °C, increasing monotonically in magnitude after changing sign from positive to negative at approximately 300 °C. The experimental results are in good agreement with analytical predictions of the sensor’s temperature-dependent responsivity, which suggest a further increase in magnitude up to −7.4 μV/(W/cm 2 ) at 1000 °C. These results highlight the unique characteristics of rhenium as a TSE transducer. The design offers compatibility with a wide range of operating temperatures and yields a measurement sensitivity that increases as the environmental conditions become more challenging.

20 FOSSIL-FUELED POWER PLANTS↗

A Scalable Solution Route to Porous Networks of Nanostructured Black Tungsten

This paper studied the feasibility of a new solution-processed method to manufacture black tungsten nanostructures by laser conversion of tungsten hexacarbonyl precursor on the Inconel 625 substrate under argon atmosphere at ambient pressure. The results show that sublimation of the precursor can be prevented if the decomposition temperature (>170 °C) is achieved using the laser heating method. Three different laser powers from 60–400 W were used to investigate the role of laser parameters on the conversion. It was found that lower laser power of 60 W resulted in a mixture of unconverted precursor and converted tungsten. Higher laser powers >200 W resulted in α-W (BCC) in one step without further heat treatment. Different oxygen concentrations from 0.5 ppm to 21 vol% were used in the laser canister to investigate the effect of oxygen concentration on the conversion. It was found that the hard vacuum (>10−4 torr) or hydrogen is not necessary to obtain α-W (BCC). The solar absorptance varied from 63–97%, depending on the amount of precursor deposited on the substrate and oxygen content in the laser canister. This solution-based laser conversion of tungsten precursor is a scalable method to manufacture tungsten coatings for high-temperature applications.

14 SOLAR ENERGY↗

Epitaxial growth and characterization of magnesium gallate (MgGa 2 O 4 ) thin films by pulsed laser deposition

To advance high power device application of MgGa 2 O 4 , it is imperative to achieve crystalline epitaxial thin films and to observe its materials’ characteristics within a wide range of growth conditions. However, there is no published work on the growth of this promising ultrawide bandgap material till this day. In this study, we report the crystalline growth of MgGa 2 O 4 thin films on c-plane (006) sapphire substrates using the pulsed laser deposition (PLD) technique in a broad range of temperature and oxygen pressure. The temperature range for this crystalline growth was within the temperature range of 300°C to 700°C and a pressure range of 1x10 -1 to 1x10 -3 Torr. Within this parameter range, the structural, chemical, optical, and surface property of MgGa 2 O 4 thin films have been investigated. Specifically, the acquired XRD patterns confirmed the film growth along the [111] preferential crystal orientation in the lattice. Here, the rocking curve measurement of the prominent (222) plane showed an increasing trend of the crystallinity with growth temperature and pressure. Furthermore, the XRD phi (φ) scan demonstrated the six-fold rotational symmetry of the MgGa 2 O 4 films and the epitaxial relationship of 30° between the film and the sapphire substrate. The XPS spectra confirmed the presence of +2 and +3 oxidation state for Mg and Ga respectively, in the films. The direct bandgap of MgGa 2 O 4 films was obtained ~5.27±0.03 eV by analyzing the UV-Vis absorbance spectra using the Tauc equation. The SEM images exhibited a granular surface morphology of the MgGa 2 O 4 films with an increasing trend in the grain size from low to high temperature and pressure. The refractive index and thickness of these films were in the range of ~1.90±0.02 and ~70±2.0 nm, respectively determined by fitting the spectroscopic ellipsometry data.

36 MATERIALS SCIENCE↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical simulation of parametric resonance in point absorbers using a simplified model

Abstract Parametric resonance is a non‐linear phenomenon in which a system can oscillate at a frequency different from its exciting frequency. Some wave energy converters are prone to this phenomenon, which is usually detrimental to their performance. Here, a computationally efficient way of simulating parametric resonance in point absorbers is presented. The model is based on linear potential theory, so the wave forces are evaluated at the mean position of the body. However, the first‐order variation of the body's centres of gravity and buoyancy is taken into account. This gives essentially the same result as a more rigorous approach of keeping terms in the equation of motion up to second order in the body motions. The only difference from a linear model is the presence of non‐zero off‐diagonal elements in the mass matrix. The model is benchmarked against state‐of‐the‐art non‐linear Froude–Krylov and computational fluid dynamics models for free decay, regular wave, and focused wave group cases. It is shown that the simplified model is able to simulate parametric resonance in pitch to a reasonable accuracy even though no non‐linear wave forces are included. The simulation speed on a standard computer is up to two orders of magnitude faster than real time.

16 TIDAL AND WAVE POWER↗

Tantalum Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.02 cm Pitch)

The United States (US) Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories (SNL). The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water moderated and — reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM 096, LEU- COMP-THERM-097, LEU-COMP-THERM-101, LEU-COMP-THERM-102, and LEU-COMP-THERM-111. Applied interests in neutron-absorbing elements at epithermal and intermediate neutron energy ranges at DOE’s Hanford Site and Savannah River Site were identified through DOE Office of Environmental Management (EM) workshops and needs surveys performed in conjunction with the National Nuclear Security Administration/Nuclear Criticality Safety Program. In response, a team lead by Oak Ridge National Laboratory (ORNL) performed a study evaluating the use of 7uPCX for testing the epithermal cross sections of materials at SNL. This marked the inception of the set of experiments described here. The purpose of these experiments was to measure the effects of tantalum in nearly-critical systems. The tantalum was introduced into the fuel arrays as experiment rods within a central test region. The central test region was designed to target the epithermal neutron energy range by providing a dry cylindrical cavity constructed of aluminum and lined with 0.04 in (0.1016 cm) thick cadmium sheet. The central test region has an outer diameter of 3.75 in (9.525 cm) length of 31 in (78.74 cm) and can hold 85 tantalum rods nominally 0.25 in (0.635 cm) outside diameter and 31.25 in (79.375 cm) long. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 2016 fuel rod positions on a pitch of 0.4 in (1.016 cm) in a series of 21 hexagonal rings positioned around the central test region. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The eight cases in this experiment series were performed in 2024 in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility by varying the number of fuel rods in the critical assembly. The personnel involved in conducting these experiments included David Ames, Elijah Lutz, Beth Hanson, Patrick Ward, Jason Soares, and Augie Chapa from SNL, as well as Mathieu Dupont and B.J. Marshall from ORNL. Case 1 had no tantalum experiment rods. Case 2 had seven tantalum rods in the center of the central test region. Case 3 had 18 tantalum rods in the third hexagonal ring of the central test region. Case 4 had 19 tantalum rods in the center of the central test region. Case 5 had 30 tantalum rods in the outer most positions of the central test region. Case 6 had 37 tantalum rods in the center of the central test region. Case 7 had 61 tantalum rods in the center of the central test region. Case 8 had 85 tantalum rods filling all positions in the central test region. All eight critical experiments are judged to be acceptable as benchmark experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Efficient Three-Dimensional CFD-Based Numerical Wave Tank for a Wave Energy Converter in Extreme Irregular Waves: Preprint

A numerical wave tank approach for computational fluid dynamics (CFD) modelling of an extreme irregular seastate is presented. The technique couples a potential flow solution with a CFD solver for more efficient numerical predictions. This method has recently become attractive both for the research community and the industry working with offshore structures. The model is used to determine the response of a submerged pressure differential wave energy converter (WEC) in a fully nonlinear irregular wave condition using the high fidelity CFD code, STAR-CCM+. Potential flow based numerical models are commonly used to predict motions and performance of wave energy converters. Wave kinematics can deviate from potential flow predictions for extreme wave conditions; the excitation loads on an absorber can also be increasingly influenced by viscous effects, not captured in engineering level models. In these extreme conditions, a Reynolds-averaged Navier-Stokes CFD model can better predict motions and loads for a WEC. Long time series with varying random seed numbers can be used to identify singular extreme wave events from a stochastic irregular sea state. This approach simulates a more realistic wave series for a given sea state than a regular wave or a focused wave. However, it is computationally infeasible to run these long time series for three-dimensional (3D) CFD simulations. In this work, two-dimensional (2D) CFD simulations with a long domain allow the full development of an extreme nonlinear wave condition. The results are used to identify extreme events from a 50-year storm condition for the PacWave site off the coast of Oregon. A relatively short time window including this extreme event is then mapped to a 3D simulation using a user defined wave methodology. Convergence studies for domain length, wave forcing lengths, and time before the extreme event were conducted.

cfd↗

An Efficient Three-Dimensional CFD-Based Numerical Wave Tank for a Wave Energy Converter in Extreme Irregular Waves

A numerical wave tank approach for computational fluid dynamics (CFD) modelling of an extreme irregular seastate is presented. The technique couples a potential flow solution with a CFD solver for more efficient numerical predictions. This method has recently become attractive both for the research community and the industry working with offshore structures. The model is used to determine the response of a submerged pressure differential wave energy converter (WEC) in a fully nonlinear irregular wave condition using the high-fidelity CFD code, STAR-CCM+. Potential flow based numerical models are commonly used to predict motions and performance of wave energy converters. Wave kinematics can deviate from potential flow predictions for extreme wave conditions; the excitation loads on an absorber can also be increasingly influenced by viscous effects, not predicted by potential flow engineering level models. In these extreme conditions, a Reynolds-averaged Navier-Stokes CFD model can better predict motions and loads for a WEC. Long time series with varying random seed numbers can be used to identify singular extreme wave events from a stochastic irregular sea state. This approach simulates a more realistic wave series for a given sea state than a regular wave or a focused wave. However, it is computationally infeasible to run these long time series for three-dimensional (3D) CFD simulations. In this work, two-dimensional (2D) CFD simulations with a long domain allow the full development of an extreme nonlinear wave condition. The results are used to identify extreme events from a 50-year storm condition for the PacWave site off the coast of Oregon. A relatively short time window including this extreme event is then mapped to a 3D simulation using a user defined wave methodology. Convergence studies for domain length, wave forcing lengths, and time before the extreme event were conducted.

CFD↗

Plasma Processing for In-Situ Field Emission Mitigation of Superconducting Radiofrequency (SRF) Cryomodules

Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface of the cavity high electric field region. Field emission reduces the maximum achievable accelerating field and generates free electrons that may interact with the beam, damage or activate the beamline. One practical method that can be used to mitigate this problem is in-situ plasma cleaning, or plasma processing. The development of a processing that can be applied in-situ is extremely advantageous, since it enables the recovery of the cryomodule performance without the need of disassembling the whole cryomodule, which is an extremely expensive and time-consuming process. On the other hand, plasma processing only requires the cryomodule warm-up to room-temperature and the subsequent processing of the contaminated cavities. The entire process is reasonably quick and involves a limited number of personnel. For these reasons we would like to advocate for continuing to invest in the R&D of plasma processing to optimize its applicability in cryomodules and for extending the technique to other frequency ranges and cavities geometries.

43 PARTICLE ACCELERATORS↗

Gate-Tunable Short-Wave Infrared Polycrystalline GeSn Phototransistors on Noncrystalline Substrates

GeSn is a group-IV alloy with immense potential to advance microelectronics technology due to its intrinsic compatibility with existing Si CMOS processes. With a sufficiently high Sn composition, GeSn is classified as a direct bandgap semiconductor. Polycrystalline GeSn holds several additional advantages, including its significantly lower synthesis cost compared to its epitaxial counterpart, as well as the versatility to grow these films on a variety of substrates. Here, in this work, we present a polycrystalline thin-film GeSn phototransistor on a fused silica substrate with a Sn composition of ~10%, showing a photoresponse in the short-wave infrared wavelength range, critical for emerging sensing applications. This device shows a gate-tunable response, with responsivities approaching up to 1.7 mA/W with only a 30 nm-thick GeSn layer. Furthermore, phototransistors offer additional adaptability through gating, which allows for the reduction of dark current. This not only enhances the signal-to-noise ratio but also offers more flexible integration with various image sensor readout implementations using different substrates. The specific detectivity of this phototransistor is within an order of magnitude of those of previously reported GeSn photodetectors grown by molecular beam epitaxy and chemical vapor deposition, even though the absorber is 3 to 20× thinner while the electrode spacing for photocarrier transport is approximately 15× longer than the carrier diffusion length in this work, showing great potential benefits of extending similar device structures to epitaxial GeSn layers. As these GeSn phototransistors utilize a noncrystalline substrate, our work establishes a fundamentally more versatile path toward monolithically integrated GeSn-based photodetectors for next-generation multimodal sensors.

36 MATERIALS SCIENCE↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Organic Matter Composition in June 2023 and September 2023 Across the McKenzie Sub-Basin Impacted by the 2020 Holiday Farm Fire

This dataset represents results from a field study aiming to understand the variability in post-fire responses of dissolved organic matter and determine drivers of post-fire responses. Samples were collected at 58 sites within the McKenzie River Watershed (Oregon, USA) that were upstream, within, and downstream of the Holiday Farm Fire burn perimeter. The samples were collected in June 2023 and September 2023 during storm events, approximately 3 years post-fire. Samples were characterized for benezenepolycarboxylic acids (BPCA) and ultra-high resolution mass spectrometry. Dissolved organic carbon and optics (absorbance and fluorescence) data can be found in a separate data packages (https://ir.library.oregonstate.edu/concern/datasets/zc77sz60m, https://ir.library.oregonstate.edu/concern/datasets/mc87q034m). Related data from a subset of sites from 2020-2022 can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1869708 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2478546. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) benzene polycarboxylic acid (BPCA) concentration data; (7) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; (8) folder of high resolution characterization of organic matter via 12 Tesla FTICR-MS data generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Optimization of Operating Profit for the FEED of the PZAS Process for CO 2 Capture on a 460 MW NGCC

A rating model of PZAS (Piperazine with the Advanced Stripper) for a 460 MW natural gas combined cycle was developed from vendor-provided equipment performance data. Surrogate rating models were built and used to optimize variable profit of the system subject to natural gas and electricity price at a fixed value for CO 2 of $\$80$/tonne. Several process constraints were considered between ambient temperatures of 4.4 and 40.5 °C. Lower lean loading resulted in lower reboiler heat duty of about 2.2 GJ/tonne. Lean loading at 0.2 mol/equiv N was sufficient at an ambient temperature of 4.4 °C to maximize variable profit. Solvent precipitation was avoided even at low lean loading (0.18 mol/mol) in the absence of a trim cooler for the lean solvent between the absorber and the cold cross exchanger. Optimal CO 2 removal was always higher than the design case removal of 90% and achieved a peak of 93.6% for 4.4 ºC ambient temperature. Lean solvent rate was a significant driver of profitability. The maximum capacity of the compressor was a significant constraint on profitability. Increasing compressor capacity by 20–30% could increase variable profit by about 21% in the case of 0.18 lean loading at 4.4 °C ambient temperature. Furthermore, this increase in profit was lower at higher ambient temperature and higher lean loading. The breakeven gas price was $\$4.6$/MMBtu at high lean loading of 0.22 mol/mol. Below this value, profit was maximized by increasing the boiler heat rate. Above this value, profit could not be increased by burning additional natural gas, requiring a reduction in boiler heat rate and consequently, specific heat duty. At lower lean loading (0.2, 0.18 mol/mol), this transition in heat duty was not observed due to the lower heat duty. As the ambient temperature increased, a similar trend in heat duty was observed at 0.22 lean loading, but the transition to lower heat duty occurred earlier at $\$4$/MMBtu. This was because of the lower CO 2 production at higher ambient temperature, making the process unprofitable at a gas price higher than $\$3$/MMBtu unless the heat duty of the stripper and natural gas boiler is steeply decreased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Maintainable Fusion Pilot Plant

The US fusion community has coalesced around the goal of building an FPP as described by the National Academies of Science, Engineering, and Medicine (NASEM). In addition to demonstrating the viability of the technologies necessary to operate such a plant, including demonstration of net energy and electricity production, NASEM found that a “fusion pilot plant will need to demonstrate the ability to efficiently perform remote maintenance and replacement in support of the design of a power plant, taking into account details of the consequences of the fusion environment, such as material activation and tritium retention in components.” Current designs of fusion demonstration reactors do usually foresee a regular exchange of their first wall modules, including the tritium breeding blankets. In the European Power Plant Conceptual Studies, it is assumed that a fusion reactor will need to change its divertor every 2 years and its first wall blanket module every 5 to 6 years to reach acceptable availability. Underlying this capability are remote-handling technologies to keep the outage for the exchange of these components short. There are many uncertainties in the remote-handling schemes, and most schemes are at a preconceptual level at best. In addition, the exchange of these components would either produce an enormous rad-waste stream or would require an enormous refurbishment activity with huge cost-prohibitive hot-cells. Past Fusion Nuclear Science Facility (FNSF) preconceptual studies have led to hot cell dimensions of an unbelievable size, likely costing tens of billions of dollars. Already at The Way (previously International Thermonuclear Experimental Reactor, ITER), hot-cells have become cost-prohibitive, demanding redesigns of the ITER first wall to reduce the toxic rad-waste/inventory. In this in-situ PFC repair project, a concept for a long-life, maintainable first wall module concept is developed and tested. This first wall concept relies on innovative remote handling to repair the first wall modules in-situ, avoiding costly refurbishments outside of the tokamak vessel. This approach was highlighted in the Fusion Energy Sciences Advisory Committee (FESAC) report on Transformative Enabling Capabilities for Efficient Advance Toward Fusion Energy. In general, the damage of the first wall armor is due to particle and radiation exposures. Load conditions vary from one fusion reactor design to another. In tokamaks, first wall Plasma Facing Components (PFCs) are exposed to far-Scrape-Off-Layer plasma fluxes, electromagnetic radiation, energetic CX neutrals, and potentially runaway electron beams. Protecting the first wall to the worst-case load conditions would require the design of a very thick first wall armor. Transient heat and particle fluxes due to disruptions or edge localized modes can lead to excessive heat loads resulting potentially in melting PFCs down to the cooling channel. Catastrophic events like these need to be avoided by appropriate disruption mitigation systems. However, failure of these systems will still put a first wall at an unacceptable risk. Hence, a first wall design needs to accommodate the occasional transient heat loads by introducing sacrificial limiters, which will absorb these transients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗