Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima

There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

Purpose: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. Methods: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9—Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H{sup ∗}(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs—tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm{sup 3}) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm{sup 2} field size. Results: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H{sup ∗}(10) value of ∼51 μSv Gy{sup −1}; this was measured at 1.15 m along the beam axis. H{sup ∗}(10) values significantly decreased with distance and angular position with respect to beam axis falling below 2 nSv Gy{sup −1} at the entrance of the maze, at the door outside the room and below detection limit in the gantry control room, and at an adjacent room (<0.1 nSv Gy{sup −1}). Finally, the agreement on H{sup ∗}(10) values between all detectors showed a direct dependence on neutron spectra at the measurement position. While conventional rem-counters (LB 6411, RadEye™ NL, NM2-458) underestimated the H{sup ∗}(10) by up to a factor of 4, Hawk TEPCs and the WENDI-II range-extended detector were found to have good performance (within 20%) even at the highest neutron fluence and energy range. Meanwhile, secondary photon dose equivalents were found to be up to five times lower than neutrons; remaining nonetheless of concern to the patient. Conclusions: Extended-range BSS, TEPCs, and the WENDI-II enable accurate measurements of stray neutrons while other rem-counters are not appropriate considering the high-energy range of neutrons involved in proton therapy.

07 ISOTOPE AND RADIATION SOURCES↗

WE-E-BRE-01: An Image-Based Skeletal Dosimetry Model for the ICRP Reference Adult Female - Internal Electron Sources

Purpose: Limitations seen in previous skeletal dosimetry models, which are still employed in commonly used software today, include the lack of consideration of electron escape and cross-fire from cortical bone, the modeling of infinite spongiosa, the disregard of the effect of varying cellularity on active marrow self-irradiation, and the lack of use of the more recent ICRP definition of a 50 micron surrogate tissue region for the osteoprogenitor cells - shallow marrow. These limitations were addressed in the present dosimetry model. Methods: Electron transport was completed to determine specific absorbed fractions to active marrow and shallow marrow of the skeletal regions of the adult female. The bone macrostructure was obtained from the whole-body hybrid computational phantom of the UF series of reference phantoms, while the bone microstructure was derived from microCT images of skeletal region samples taken from a 45 year-old female cadaver. The target tissue regions were active marrow and shallow marrow. The source tissues were active marrow, inactive marrow, trabecular bone volume, trabecular bone surfaces, cortical bone volume and cortical bone surfaces. The marrow cellularity was varied from 10 to 100 percent for active marrow self-irradiation. A total of 33 discrete electron energies, ranging from 1 keV to 10 MeV, were either simulated or modeled analytically. Results: The method of combining macro- and microstructure absorbed fractions calculated using MCNPX electron transport was found to yield results similar to those determined with the PIRT model for the UF adult male in the Hough et al. study. Conclusion: The calculated skeletal averaged absorbed fractions for each source-target combination were found to follow similar trends of more recent dosimetry models (image-based models) and did not follow current models used in nuclear medicine dosimetry at high energies (due to that models use of an infinite expanse of trabecular spongiosa)

60 APPLIED LIFE SCIENCES↗

Long life nickel electrodes for a nickel-hydrogen cell. III - Results of an accelerated test and failure analyses

Nineteen different designs of nickel electrodes were tested in Ni/H2 boiler plate cells in an accelerated low earth orbit cycle regime to the end of their life. The failure analyses of these cells showed that the major performance changes due to the cycling was a severe reduction of their high rate discharge capability rather than an absolute capacity reduction. Many physical changes of the nickel electrodes were observed after the cycling test. These changes include dimensional expansion, sinter rupture, loose black powdering of the active material, morphology changes, active material migration, increase of pore volume, change of pore distribution, and increase of surface area. All of these were caused by active material expansion with cycling. Among these changes, the morphology change which involves migration of active material away from the current collecting nickel sinter appears to be that most responsible for the reduction of the rate capability.

Lim, H. S.↗

Influence of cold walls on PET image quantification and volume segmentation: A phantom study

Purpose: Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These “cold” walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in errors in the estimation of standardized uptake values. Numerous papers suggest that this is an issue for phantom work simulating tumor tissue, quality control, and calibration work. This study aims to investigate the influence of the cold plastic wall thickness on the quantification of 18F-fluorodeoxyglucose on the image activity recovery and on the performance of advanced automatic segmentation algorithms for the delineation of active regions delimited by plastic walls.Methods: A commercial set of six spheres of different diameters was replicated using a manufacturing technique which achieves a reduction in plastic walls thickness of up to 90%, while keeping the same internal volume. Both sets of thin- and thick-wall inserts were imaged simultaneously in a custom phantom for six different tumor-to-background ratios. Intensity values were compared in terms of mean and maximum standardized uptake values (SUVs) in the spheres and mean SUV of the hottest 1 ml region (SUV{sub max}, SUV{sub mean}, and SUV{sub peak}). The recovery coefficient (RC) was also derived for each sphere. The results were compared against the values predicted by a theoretical model of the PET-intensity profiles for the same tumor-to-background ratios (TBRs), sphere sizes, and wall thicknesses. In addition, ten automatic segmentation methods, written in house, were applied to both thin- and thick-wall inserts. The contours obtained were compared to computed tomography derived gold standard (“ground truth”), using five different accuracy metrics.Results: The authors' results showed that thin-wall inserts achieved significantly higher SUV{sub mean}, SUV{sub max}, and RC values (up to 25%, 16%, and 25% higher, respectively) compared to thick-wall inserts, which was in agreement with the theory. This effect decreased with increasing sphere size and TBR, and resulted in substantial (>5%) differences between thin- and thick-wall inserts for spheres up to 30 mm diameter and TBR up to 4. Thinner plastic walls were also shown to significantly improve the delineation accuracy for the majority of the segmentation methods tested, by increasing the proportion of lesion voxels detected, although the errors in image quantification remained non-negligible.Conclusions: This study quantified the significant effect of a 90% reduction in the thickness of insert walls on SUV quantification and PET-based boundary detection. Mean SUVs inside the inserts and recovery coefficients were particularly affected by the presence of thick cold walls, as predicted by a theoretical approach. The accuracy of some delineation algorithms was also significantly improved by the introduction of thin wall inserts instead of thick wall inserts. This study demonstrates the risk of errors deriving from the use of cold wall inserts to assess and compare the performance of PET segmentation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Co-Design of Charge Transport Superhighways to Connect Catalytic Sites in Soft Photoelectrochemical Systems

Efficient photon-to-electron-to-molecule conversion requires multi-length scale control over charge transport pathways, where electronic charges are delivered to catalytic sites under high mass transport flux. A fundamental question is how can we co-design charge transport pathways to promote efficient charge transfer to/from catalytic sites in complex three-dimensional architectures? Soft conducting polymer systems offer exceptional promise to provide three-dimensional charge transport networks, where electrolyte (ion and solvent) can interdiffuse to promote long-lived charge carriers and the molecular nature allows for strategic synthetic design of catalytic sites. Herein we combine theoretical and experimental approaches to investigate the earliest stages of photoelectrochemical deposition of near-surface catalytic sites (Pt) on soft bulk heterojunction polymeric semiconductors composed of a prototype donor (PTB7-Th) and a prototype acceptor (N2200) as a model system towards better understanding molecular catalyst-polymer site interactions. We focus initially on photoelectrochemical deposition of low Pt loadings, nanoparticle sizes (formed by progressive nucleation) below 20 nm, for both density functional theory (DFT) modeling studies and for spectroscopic characterization using surface-sensitive X-ray and UV-photoemission (XPS/UPS). DFT modeling of “n-type” N2200 slabs reveal for the first time that sulfur atoms in the thiophene units serve as the lowest-energy adsorption sites for single Pt atoms, while larger Pt clusters engage more complexly with both thiophene and naphthalene diimide (NDI) core sites. Changes in chemical composition observed by X-ray photoelectron spectroscopy (XPS) support the DFT predictions, and the angle-resolved measurements reveal that Pt nucleation initiates at subsurface sites which appear to be localized active domains that promote charge transport/transfer and enable vertical growth toward the surface. These results suggest that light-activated Pt nanoparticle deposition decorates energetically distinct sites, where photoactivity is dictated by the local energetics of those sites, and the fact that they represent the termini of charge transport “super-highways” – a small percentage of the total volume of the donor/acceptor polymeric active layer which carries most of the photocurrent generated during both Pt deposition and photoelectrochemical HER. We posit that these initial studies provide a foundational strategy for design of catalytic sites in the near surface regions of complex polymeric materials and advancing soft semiconductor-based photoelectrochemical systems. Achieving a nanometer-scale understanding of catalyst deposition and the impact of local composition and energetics on that placement, should ultimately provide the design guidelines (co-design) for a broad array of catalysts at sites that optimize that efficiency and maximize platform durability.

14 SOLAR ENERGY↗

Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be obtained. The authors found that, by selectively exciting parts of the volume, the authors could increase the reconstruction quality even further while reducing the amount of measurements. Additionally, the inverse solution of this activation method degrades slower for increasing volumes. Finally, the methodology was applied to noisy EPR measurements: using the reduced EPR setup’s symmetry and the partial activation method, an increase in reconstruction quality of ≈80% can be seen with a speedup of the measurements with 10%. Conclusions: Applying the aforementioned requirements to the EPR setup and stabilizing the EPR measurements showed a tremendous increase in noise robustness, thereby making EPR a valuable method for quantitative imaging of multidimensional MNP distributions.

60 APPLIED LIFE SCIENCES↗

Contributions of MSNA and stroke volume to orthostatic intolerance following bed rest

We examined whether the altered orthostatic tolerance following 14 days of head-down tilt bed rest (HDBR) was related to inadequate sympathetic outflow or to excessive reductions in cardiac output during a 10- to 15-min head-up tilt (HUT) test. Heart rate, blood pressure (BP, Finapres), muscle sympathetic nerve activity (MSNA, microneurography), and stroke volume blood velocity (SVV, Doppler ultrasound) were assessed during supine 30 degrees (5 min) and 60 degrees (5-10 min) HUT positions in 15 individuals who successfully completed the pre-HDBR test without evidence of orthostatic intolerance. Subjects were classified as being orthostatically tolerant (OT, n = 9) or intolerant (OI, n = 6) following the post-HDBR test. MSNA, BP, and SVV during supine and HUT postures were not altered in the OT group. Hypotension during 60 degrees HUT in the post-bed rest test for the OI group (P < 0.05) was associated with a blunted increase in MSNA (P < 0.05). SVV was reduced following HDBR in the OI group (main effect of HDBR, P < 0.02). The data support the hypothesis that bed rest-induced orthostatic intolerance is related to an inadequate increase in sympathetic discharge that cannot compensate for a greater postural reduction in stroke volume.

NASA Discipline Musculoskeletal↗

Volume III. DUNE far detector technical coordination

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photovoltaic concentrator assembly with optically active cover

A photovoltaic concentrator assembly that includes a housing that defines an internal volume and includes a rim, wherein the rim defines an opening into the internal volume, a photovoltaic cell positioned in the internal volume, and an optical element that includes an optically active body and a flange extending outward from the body, wherein the flange is sealingly engaged with the rim of the housing to enclose the internal volume.

14 SOLAR ENERGY↗

Anti-P2 structured Na0.5NbO2 and its negative strain effect

Layer-structured oxides are studied for their essential roles in various applications (e.g. high-energy batteries and superconductors) due to their distinctive physical structures and chemical properties. Most of the layered AxMO2 (A = alkali ions, M = transition metals) are composed of MO6 octahedra and various A coordination polyhedra such as octahedra (O), tetrahedra (T) or trigonal prisms (P). Herein, we report a new layered oxide material, anti-P2 Na0.5NbO2, which is composed of NbO6 trigonal prisms and NaO6 octahedra. Its lattice shrinks as sodium (Na) ions are intercalated in it and expands when the ions are deintercalated (a negative volume or strain effect). Analysis by X-ray absorption spectroscopy and density functional theory (DFT) calculations indicates that the negative volume effect is mainly a result of the enhanced interlayer (Na–O) interaction and the weakened Nb– Nb and Nb–O bonding in the O–Nb–O slab upon Na intercalation. Moreover, Na0.5NbO2 exhibits high structural stability, a long cycle life and prominent rate performance for Na-ion batteries. These distinctive features make Na0.5NbO2 an ideal ‘‘volume buffer’’ to compensate for positive-strain electrode materials. These findings will arouse great interest in anti-P2 layered oxides for materials science and applications, and enrich the understanding of novel negative-strain materials for energy storage either as excellent independent active electrode materials or as volume buffers for constructing long-life composite electrodes made of positive-strain materials.

Wang, Xuefeng↗

Automating the SMAP Ground Data System to Support Lights-Out Operations

The Soil Moisture Active Passive (SMAP) Mission is a first tier mission in NASA's Earth Science Decadal Survey. SMAP will provide a global mapping of soil moisture and its freeze/thaw states. This mapping will be used to enhance the understanding of processes that link the terrestrial water, energy, and carbon cycles, and to enhance weather and forecast capabilities. NASA's Jet Propulsion Laboratory has been selected as the lead center for the development and operation of SMAP. The Jet Propulsion Laboratory (JPL) has an extensive history of successful deep space exploration. JPL missions have typically been large scale Class A missions with significant budget and staffing. SMAP represents a new area of JPL focus towards low cost Earth science missions. Success in this new area requires changes to the way that JPL has traditionally provided the Mission Operations System (MOS)/Ground Data System (GDS) functions. The operation of SMAP requires more routine operations activities and support for higher data rates and data volumes than have been achieved in the past. These activities must be addressed by a reduced operations team and support staff. To meet this challenge, the SMAP ground data system provides automation that will perform unattended operations, including automated commanding of the SMAP spacecraft.

GDS↗

A query into the source of proton emission from solar flares, report 2

Seven solar flares that were followed by major proton events were examined to determine the diverse and common properties of major flares. The most probable site of primary proton acceleration is cospatial with the site and instant of formation of coronal loops. Because loop formation occurs through the entire duration of major solar flares over significantly large areas of active centers, it is proposed that proton injection occurs from a relatively large volume of space in the corona of active centers and is continuous throughout, and possibly even after, the visible duration of the related chromospheric flare. The flare veil is hypothesized to occur as a result of proton charge exchange taking place in the white-light transient. The Kopp and Pneuman model of loop formation by magnetic reconnection is suggested as an adequate and satisfactory model for all major flares with the provision that the beginning of rapid magnetic field reconnection is coincident with flare start.

Martin, S. F.↗

Interior Landscape Plants for Indoor Air Pollution Abatement

In this study, the leaves, roots, soil, and associated microorganisms of plants have been evaluated as a possible means of reducing indoor air pollutants. Additionally, a novel approach of using plant systems for removing high concentrations of indoor air pollutants such as cigarette smoke, organic solvents, and possibly radon has been designed from this work. This air filter design combines plants with an activated carbon filter. The rationale for this design, which evolved from wastewater treatment studies, is based on moving large volumes of contaminated air through an activated carbon bed where smoke, organic chemicals, pathogenic microorganisms (if present), and possibly radon are absorbed by the carbon filter. Plant roots and their associated microorganisms then destroy the pathogenic viruses, bacteria, and the organic chemicals, eventually converting all of these air pollutants into new plant tissue. It is believed that the decayed radon products would be taken up the plant roots and retained in the plant tissue.

Wolverton, B. C.↗

Water vapor sorption isotherms, pore structure, and moisture transport characteristics of alkali-activated and Portland cement-based binders

Moisture transport plays a key role in determining the different durability-related features of cementitious materials. In this paper, moisture sorption in a range of low-calcium (geopolymer-type) and calcium-rich alkali-activated binders are studied and compared with that of Portland cement-based binders. Through the analysis of water vapor sorption isotherms (WVSI) and mercury intrusion porosimetry (MIP) test results, two vastly different pore structures were observed. Fly ash-based geopolymer-type binders showed a very porous structure where a large volume of mesopores coexisted with a significant volume of macropores. Alkali-activated slag binders, however, had a very fine pore structure, with a relative lack of large macropores. The different pore structure of fly ash-based and slag-based binders led to amplification of pore blocking and cavitation in blended systems by the addition of slag. Analysis of the sorption kinetics showed the prominent effect of the presence of calcium in the matrix to reduce the permeability.

36 MATERIALS SCIENCE↗

Depth‐dependent concentrations of hematopoietic stem cells in the adult skeleton: Implications for active marrow dosimetry

Purpose The hematopoietically active (or red) bone marrow is the target tissue assigned in skeletal dosimetry models for assessment of stochastic effects (leukemia induction) as well as tissue reactions (marrow toxicity). Active marrow, however, is in reality a surrogate tissue region for specific cell populations, namely the hematopoietic stem and progenitor cells. Present models of active marrow dosimetry implicitly assume that these cells are uniformly localized throughout the marrow spaces of trabecular spongiosa. Data from Watchman et al. and Bourke et al., however, clearly indicate that there is a substantial spatial concentration gradient of these cells with the highest concentrations localized near the bone trabeculae surfaces. The purpose of the present study was thus to explore the dosimetric implications of these spatial gradients on active marrow dosimetry. Methods Images of several bone sites from a 45‐yr female were retagged to group active marrow voxels into 50 μm increments of marrow depth, after which electron and alpha‐particle depth‐dependent specific absorbed fractions were computed for four source tissues — active marrow, inactive marrow, bone trabeculae volumes, and bone trabeculae surfaces. Corresponding depth‐dependent S values (dose to a target tissue per decay in a source tissue) were computed and further weighted by the relative target cell concentration. These depth‐weighted radionuclide S values were systematically compared to the more traditional volume‐averaged radionuclide S values of the MIRD schema for both individual bones of the skeleton and their skeletal‐averaged quantities. Results For both beta‐emitters and alpha‐emitters localized in the active and inactive marrow, depth‐weighted S values were shown to differ from volume‐averaged S values by only a few percent, as dose gradients across the marrow tissues are nonexistent. For bone volume and bone surface sources of alpha‐emitters and lower energy beta‐emitters, when marrow dose gradients are expected, explicit consideration of target cell spatial concentration gradients are shown to significantly impact marrow dosimetry. Conclusions For medical isotopes currently utilized for treatment of skeletal metastases, namely 153 Sm and 223 Ra, accounting for hematopoietic stem and progenitor cell concentration gradients resulted in maximum percent differences to reference skeletal‐averaged S values of ~21% and 55%, respectively.

Geyer, Amy M.↗

3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13–125 Gy).Conclusions: A three-dimensional inpatient dose reconstruction method has been developed that is based on the PET/CT data of a patient treated with {sup 90}Y microspheres. It allows for a complete description of the absorbed dose by the tumor and critical structures. It represents the first step in building predictive models for treatment outcomes for patients receiving this therapeutic modality as well as it allows for better analysis of patients' dose response and will ultimately improve future treatment administration.

61 RADIATION PROTECTION AND DOSIMETRY↗