Search NASA⌕ Search

SEARCH · Search NASA

Results for “air temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Vegetation Warming Experiment: 15N Uptake Experiment Water-Extractable Soil Nutrients, Utqiagvik (Barrow), Alaska, 2018

This dataset consists of measured water-extractable carbon and nutrients measured on soils collected from warming experiment enclosures and paired control plots. Harvest types include both natural abundance and enriched soils. Vegetation warming chambers (Zero Power) were deployed on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. These chambers (Figure 1) consistently elevated air temperatures by approximately 4°C using a self-venting system described by Lewin et al (2017). Five chambers were deployed from June 17, 2018 to September 24, 2018 on the BEO within a 1 km2 area centered on 71.275N, -156.641W. Each chamber was co-located with an ambient plot where temperatures were not manipulated on patches of tundra containing the target species Arctagrostis latifolia. An intensive field campaign in late July investigated the impact of warming had on A. latifolia biomass, chemistry, and uptake of 15N labeled ammonia that was injected into the surface soils for one week. Initial measurements were taken on July 21, 2018. Harvest occurred on July 27, 2018. Water-extractable nutrients in soils were measured in July following harvests of A. latifolia plants and underlying soils. Availability of ammonia, nitrate, and phosphate throughout the growing season was measured by extracting nutrients bound to anion and cation binding resins deployed from July through September. Environmental variables (thaw depth, surface soil temperatures, surface soil moisture) were measured. Leaf traits and root traits of A. latifolia were also measured. The data package includes one *.csv data file and one *.pdf user guide. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: 15N Uptake Experiment Arctagrostis latifolia Canopy Traits, Utqiagvik (Barrow), Alaska, 2018

This dataset consists of measured Arctagrostis latifolia canopy traits harvested from vegetation warming experiment enclosures and paired control plots located on the BEO, Utqiavik, Alaska. Harvest types include both natural abundance and enriched A. latifolia. Canopy traits measured include leaf area index (LAI), specific leaf area (SLA) and maximum height. Vegetation warming chambers (Zero Power) were deployed on the Barrow Environmental Observatory (BEO), Utqiavik, Alaska. These chambers (Figure 1) consistently elevated air temperatures by approximately 4°C using a self-venting system described by Lewin et al (2017). Five chambers were deployed from June 17, 2018 to September 24, 2018 on the BEO within a 1 km2 area centered on 71.275N, -156.641W. Each chamber was co-located with an ambient plot where temperatures were not manipulated on patches of tundra containing the target species Arctagrostis latifolia. An intensive field campaign in late July investigated the impact of warming had on A. latifolia biomass, chemistry, and uptake of 15N labeled ammonia that was injected into the surface soils for one week. Initial measurements were taken on July 21, 2018. Harvest occurred on July 27, 2018. Water-extractable nutrients in soils were measured in July following harvests of A. latifolia plants and underlying soils. Availability of ammonia, nitrate, and phosphate throughout the growing season was measured by extracting nutrients bound to anion and cation binding resins deployed from July through September. Environmental variables (thaw depth, surface soil temperatures, surface soil moisture) were measured. Leaf traits and root traits of A. latifolia were also measured. This dataset includes one csv file and one pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature: Supporting Data

This dataset was used to assess the potential of a Distributed Temperature Profiling System developed and presented in the article named "A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature" and submitted to Cryosphere. There are three comma-delimited data files (.csv). Each of them contains snow or soil temperature with times (UTC) in the first column and temperature at various vertical distance from the ground surface (positive means in air/snow) or below the ground surface (negative means in soil). The measurements were acquired every 15 minutes. Data collected at the East River, Colorado site with two probes: 1) measuring air/snow temperature from 1.1 m above the ground surface to the ground surface (with 5 or 10 cm spacing between sensors) and 2) measuring soil temperature from the ground surface to 0.7 m depth (with 5 or 10 cm spacing between sensors). Data collected at the Teller road (mile 27) site near Nome, Alaska with one probe: measuring soil temperature from 5 cm above the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors). Additional metadata included in *.csv and *.pdf files. NGEE Arctic Project Summary: The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

CLMU Anthropogenic Heat Sensitivity Experiments

User namelist settings, code changes, and driving scripts to set to CLM5 on NERSC for deciphering the sensitivity of urban canopy air temperature to anthropogenic heat flux experiments. More details are available in README.md.

Earth Systems↗

BSEC VPRM 10m Hourly Biogenic Fluxes in Baltimore (2021)

Model outputs from the Vegetation Photosynthesis and Respiration Model (VPRM: version from Horne et al. in prep). Model remote sensing inputs come from Sential 2-derived EVI and LSWI. Model meteorological inputs for two-meter air temperature and shortwave incoming come from the BSEC WRF 2021 Control Run (Foust, W. 2023). Plant functional Types (PFTs) are spatially classified using the Chesapeake Bay Program 2018 land use land cover product. The final biogenic flux (µmol CO2 m^-2 s^-1) outputs of NEE, RESP, and GEE are a weighted average based on the portion of PFTs within the cell. Individual PFT outputs are saved inside PFT directories (e.g., Crops, Grass, etc.) inside the specific month directory. Model outputs are denoted as a negative flux into the land system (i.e., photosynthesis) and a positive flux as a net release into the overlying atmosphere. Respiration (RESP) fluxes are positive and combine heterotrophic (only soil) and autotrophic sources. Gross ecosystem exchange (GEE) is a negative flux driven by only photosynthetic activity from vegetation, and the Net ecosystem exchange (NEE) is the sum of the two (i.e., NEE=RESP+GEE). Data Characteristics Spatial Resolution: 10m Temporal Resolution: Hourly File Format: VPRM_ _BSEC. .tif (Hour is in UTC) For more information on the model results, please email Jason Horne (jph6488@psu.edu). References: Foust, W. (2023). BSEC WRF 2021 Control Run Output (v0.1.0) [Data set]. MSD-LIVE Data Repository. https://data.msdlive.org/records/m0e6m-vvq17

Baltimore↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Enhanced Air-Cooling System with Optimized Asynchronously-Cooled Thermal Energy Storage

A transformative dry-cooling system that includes two primary dry-cooling components has been developed in this project. The two main features of this new technology consist of: (a) an ultra-enhanced air-cooled condenser (ACC), with novel swirl-producing and boundary-layer disrupting enhanced surface on the air-side of the condenser that substantially increase the heat transfer coefficients, and (b) a novel daytime peak-load shifting system that reduces the ambient air inlet temperature for air cooling, consisting of a highly compact and enhanced air pre-cooler that transfers the heat load to a unique thermal energy storage (TES), and which is coupled to the ACC in (a).

20 FOSSIL-FUELED POWER PLANTS↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗

Building Envelope Characteristics in Cold Climates

Prescriptive guidelines for thermal insulation in the design of buildings in cold climates have traditionally been derived by a holistic consideration of climatic factors, energy policy, environmental policy, and economics. The differences in thermal barrier requirements in buildings across the arctic and subarctic regions of the world are influenced as much by the differing priorities of the governing bodies that set these requirements as by actual physical demands and conditions. Usually, national requirements for building envelope characteristics such as thermal insulation values, building envelope airtightness, vapor permeability, building mass, and detailing are based on economics, durability, and environmental considerations. Consideration of thermal energy system resilience provides a new paradigm through which to view the optimization of these parameters. The paper describes specifics of construction in cold climates; summarizes best practice requirements for the building envelope characteristics for buildings located in cold and arctic climate of the United States, Canada, and Scandinavian countries; provides some details illustrating how to implement these requirements; and compares the effects of different levels of building envelope efficiency and building mass on indoor air temperature decay when heat supply is interrupted. The paper also presents results from experts' discussions during the consultation forum "Thermal Energy Systems Resilience in Cold/Arctic Climates" (ERDC 2020) and research conducted under the IEA EBC Annex 73, the Environmental Security Technology Certification Program (ESTCP) Project "Technologies Integration to Achieve Resilient, Low-Energy Military Installations," and U.S. Army Program project 633734T1500 under Military Engineering Technology Demonstration. The paper complements the Cold-Climate Design Guide (ASHRAE 2015) with a focus on the resilience of thermal energy systems.

Arctic↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan K.↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Environmental monitoring data from the 2022-2023 field experiment at Game Ridge, Missoula County, Montana, USA

This dataset contains sensor data from programmed loggers as well as handheld moisture probes, including weather data, air and soil temperature, and soil volumetric water content. Data files and data dictionary(ies) are uploaded as .csv files. The Users Guide is a .pdf file. Location data can be found in the Google Earth file GameRidge_SitePlotCoordinates.kmz.kml included here. These datasets were collected for Plant Carbohydrate Depletion, Mycorrhizal Networks, and Vulnerability to Drought: An Experimental Test in the Field. This experiment examined the interdependency between plant hydraulics and carbohydrate availability and sought to develop ways to incorporate interactions with below ground symbiotic organisms to better model and quantify forest response to drought. This environmental data was collected to provide context for the fungal community data and Pinus ponderosa physiological data.

54 ENVIRONMENTAL SCIENCES↗

TARP Identifying Critical Thresholds for Acute Response of Plants and Ecosystems to Water Stress at Walker Branch Watershed, 2002-2005

This dataset contains data from a manipulative field study aimed at identifying critical thresholds for acute response of plants and ecosystems to water stress (TARP) that took place at Walker Branch Watershed in Oak Ridge, Tennessee from 2002-2005 (2002-06-20 to 2005-12-16). The study used understory tents for the removal of 100% of the growing-season throughfall and stem flow, to provide data on the impact of acute drought on mechanisms responsible for growth and mortality of deciduous forest canopy trees representative of common plant functional types (Liriodendron and Quercus). Through three years of manipulation (2003, 2004 and 2005; pretreatment measurements in 2002) various measures of tree response to surface moisture deficits were recorded including root and leaf traits, plant nonstructural carbohydrates status, hourly sapflow, basal area, and periodic observations of foliar photosynthesis and conductance. Additionally, environmental data such as air and soil temperature, soil water content, and soil matric potential were recorded. This dataset contains data 16 files in comma-separate (*.csv) format. Additional metadata are provided: 16 data dictionaries and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.

basal area↗

Energy-Efficient and Water-Saving Sorbent Regeneration at Near Room Temperature for Direct Air Capture

Here this study reports energy-efficient and water-saving microwave-accelerated regeneration of sorbent (MARS) for dilute carbon capture from the ambient air. The experimental studies indicated that the CO 2 desorption rate from the chemisorbents increased with microwave output under near-isothermal conditions at near room temperature. The reduced activation energy of MARS, i.e., 20–28 kJ/mol, indicated enhanced CO 2 desorption kinetics by microwave-induced rotational–vibrational (rovibrational) coupling transitions, primarily due to the highly polarized feature of the carbamate (CO 2 -PEI). The instant and selective delivery of microwave energy to the targeted polarized C–N bonds at room temperature is particularly advantageous for energy-efficient direct air capture. The experimental results also demonstrated a good working capacity of 0.6–1.4 mmol of CO 2 /g and a promising rapid MARS-DAC process with microwave swing. As it does not require steam regeneration and heat exchanger, a simple MARS process is attractive for CO 2 capture in water-stressed regions.

36 MATERIALS SCIENCE↗

Air separation and N 2 purification with Ba 0.15 Sr 0.85 FeO 3-$δ$ via a two-step thermochemical process

Thermochemical air separation to produce high-purity N 2 was demonstrated in a vertical tube reactor via a two-step reduction–oxidation cycle with an A-site substituted perovskite Ba 0.15 Sr 0.85 FeO 3–δ (BSF1585). BSF1585 particles were synthesized and characterized in terms of their chemical, morphological, and thermophysical properties. A thermodynamic cycle model and sensitivity analysis using computational heat and mass transfer models of the reactor were used to select the system operating parameters for a concentrating solar thermal-driven process. Thermal reduction up to 800 °C in air and temperature-swing air separation from 800 °C to minimum temperatures between 400 and 600 °C were performed in the reactor containing a 35 g packed bed of BSF1585. The reactor was characterized for dispersion, and air separation was characterized via mass spectrometry. Gas measurements indicated that the reactor produced N 2 with O 2 impurity concentrations as low as 0.02 % for > 30 min of operation. Additionally, a parametric study of air flow rates suggested that differences in observed and thermodynamically predicted O 2 impurities were due to imperfect gas transport in the bed. Temperature swing reduction/oxidation cycling experiments between 800 and 400 °C in air were conducted with no statistically significant degradation in N 2 purity over 50 cycles.

14 SOLAR ENERGY↗