Radiation-Free Weekend Rescued! Continuous Accelerated Irradiation of 7-Days per Week Is Equal to Accelerated Fractionation With Concomitant Boost of 7 Fractions in 5-Days per Week: Report on Phase 3 Clinical Trial in Head-and-Neck Cancer Patients

Purpose: To report long-term results of randomized trial comparing 2 accelerated fractionations of definitive radiation therapy assessing the need to irradiate during weekend in patients with head and neck squamous cell carcinoma. Methods and Materials: A total of 345 patients with SCC of the oral cavity, larynx, and oro- or hypo-pharynx, stage T2-4N0-1M0, were randomized to receive continuous accelerated irradiation (CAIR: once per day, 7 days per week) or concomitant accelerated boost (CB: once per day, 3 days per week, and twice per day, 2 days per week). Total dose ranged from 66.6-72 Gy, dose per fraction was 1.8 Gy, number of fractions ranged from 37-40 fractions, and overall treatment time ranged from 37-40 days. Results: No differences for all trial end-points were noted. At 5 and 10 years, the actuarial rates of local-regional control were 63% and 60% for CAIR vs 65% and 60% for CB, and the corresponding overall survival were 40% and 25% vs 44% and 25%, respectively. Confluent mucositis was the main acute toxicity, with an incidence of 89% in CAIR and 86% in CB patients. The 5-year rate of grade 3-4 late radiation morbidity was 6% for both regimens. Conclusions: Results of this trial indicate that the effects of accelerated fractionation can be achieve by delivering twice-per-day irradiation on weekday(s). This trial has also confirmed that an accelerated, 6-weeks schedule is a reasonable option for patients with intermediate-stage head-and-neck squamous cell carcinoma because of the associated high cure rate and minimal severe late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Boosting the activity of non-platinum group metal electrocatalyst for the reduction of oxygen via dual-ligated atomically dispersed precursors immobilized on carbon supports

This paper describes the use of both atomically dispersed precursors (ADPs) and conductive carbon dispersion towards the synthesis of iron-based single atom electrocatalysts for the oxygen reduction reaction (ORR). For non-platinum group metal (non-PGM) catalysts, single iron, cobalt or manganese atoms coordinated with nitrogen are the most active structures towards the ORR. Achieving a high density of active sites made of single atoms is still challenging, requiring careful controls of pyrolysis to reduce the sintering of metal active sites. Herewith, we present a new strategy to synthesize iron-based single atom ORR electrocatalysts using a two pronged approach. We first designed a dual-ligated metal organic framework (MOF) precursor. This MOF was then immobilized onto Ketjen black carbon that serves as a conductive dispersion medium for creating the highly dispersed single atom sites. In this work, we demonstrate a near complete dispersion of the iron sites without obvious formation of nanoparticles. The activity of the resulting electrocatalyst exhibited an onset potential of 0.96 V and a half-wave potential of 0.84 V vs. reversible hydrogen electrode (RHE).

42 ENGINEERING↗

Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system

Purpose: A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. Methods: Using a departmental incident learning system, eight incidents were noted over a two-year period in which fields were treated 'out-of-sequence,' that is, fields from a boost phase were treated, while the patient was still in the initial phase of treatment. As a result, an error-prevention policy was instituted in which radiation treatment fields are 'hidden' within the oncology information system (OIS) when they are not in current use. In this way, fields are only available to be treated in the intended sequence and, importantly, old fields cannot be activated at the linear accelerator control console. Results: No out-of-sequence treatments have been reported in more than two years since the policy change. Furthermore, at least three near-miss incidents were detected and corrected as a result of the policy change. In the first two, the policy operated as intended to directly prevent an error in field scheduling. In the third near-miss, the policy operated 'off target' to prevent a type of error scenario that it was not directly intended to prevent. In this incident, an incorrect digitally reconstructed radiograph (DRR) was scheduled in the OIS for a patient receiving lung cancer treatment. The incorrect DRR had an isocenter which was misplaced by approximately two centimeters. The error was a result of a field from an old plan being scheduled instead of the intended new plan. As a result of the policy described above, the DRR field could not be activated for treatment however and the error was discovered and corrected. Other quality control barriers in place would have been unlikely to have detected this error. Conclusions: In these examples, a policy was adopted based on incident learning, which prevented several errors, at least one of which was potentially severe. These examples underscore the need for a rigorous, systematic incident learning process within each clinic. The experiences reported in this technical note demonstrate the value of near-miss incident reporting to improve patient safety.

60 APPLIED LIFE SCIENCES↗

Preliminary Performance Data on Westinghouse Electronic Power Regulator Operating on J34-WE-32 Turbojet Engine in Altitude Wind Tunnel

The behavior of the Westinghouse electronic power regulator operating on a J34-WE-32 turbojet engine was investigated in the NACA Lewis altitude wind tunnel at the request of the Bureau of Aeronautics, Department of the Navy. The object of the program was to determine the, steady-state stability and transient characteristics of the engine under control at various altitudes and ram pressure ratios, without afterburning. Recordings of the response of the following parameters to step changes in power lever position throughout the available operating range of the engine were obtained; ram pressure ratio, compressor-discharge pressure, exhaust-nozzle area, engine speed, turbine-outlet temperature, fuel-valve position, jet thrust, air flow, turbine-discharge pressure, fuel flow, throttle position, and boost-pump pressure. Representative preliminary data showing the actual time response of these variables are presented. These data are presented in the form of reproductions of oscillographic traces.

Ketchum, James R.↗

Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The future of the grid will be powered by AI—or undermined by it. Artificial intelligence is rapidly reshaping grid operations, improving fault detection, forecasting accuracy, and real-time optimization. As AI systems move closer to operational decision loops, however, they introduce new consequence pathways: expanded attack surfaces, model integrity risks, regulatory exposure, and human-automation challenges. This talk presents a consequence-driven framework for deploying AI responsibly in the electric grid. Attendees will gain practical strategies to strengthen resilience, boost reliability, and deploy AI securely — ensuring the grid of the future is not only smarter but safer.

25 - ENERGY STORAGE↗

Tools for unbinned unfolding

Machine learning has enabled differential cross section measurements that are not discretized. Going beyond the traditional histogram-based paradigm, these unbinned unfolding methods are rapidly being integrated into experimental workflows. Here, in order to enable widespread adaptation and standardization, we develop methods, benchmarks, and software for unbinned unfolding. For methodology, we demonstrate the utility of boosted decision trees for unfolding with a relatively small number of high-level features. This complements state-of-the-art deep learning models capable of unfolding the full phase space. To benchmark unbinned unfolding methods, we develop an extension of existing dataset to include acceptance effects, a necessary challenge for real measurements. Additionally, we directly compare binned and unbinned methods using discretized inputs for the latter in order to control for the binning itself. Lastly, we have assembled two software packages for the OmniFold unbinned unfolding method that should serve as the starting point for any future analyses using this technique. One package is based on the widely-used RooUnfold framework and the other is a standalone package available through the Python Package Index (PyPI).

47 OTHER INSTRUMENTATION↗

Principles of Product Quality Control of German Radioactive Waste Forms from the Reprocessing of Spent Fuel: Vitrification, Compaction and Numerical Simulation - 12529

The German product quality control is inter alia responsible for control of two radioactive waste forms of heat generating waste: a) homogeneous vitrified HLW and b) heterogeneous compacted hulls, end-pieces and technological metallic waste. In either case, significantly different metrology is employed at the site of the conditioning plant for the obligatory nuclide inventory declaration. To facilitate an independent evaluation and checking of the accompanying documentation numerical simulations are carried out. The physical and chemical properties of radioactive waste residues are used to assess the data consistency and uncertainty margins, as well as to predict the long-term behavior of the radioactive waste. This is relevant for repository acceptance and safety considerations. Our new numerical approach follows a bottom-up simulation starting from the burn-up behavior of the fuel elements in the reactor core. The output of these burn-up calculations is then coupled with a program that simulates the material separation in the subsequent dissolution and extraction processes normalized to the mass balance. Follow-up simulations of the separated reprocessing lines of a) the vitrification of highly-active liquid and b) the compaction of residual intermediate-active metallic hulls remaining after fuel pellets dissolution, end-pieces and technological waste, allows calculating expectation values for the various repository relevant properties of either waste stream. The principles of the German product quality control of radioactive waste residues from the spent fuel reprocessing have been introduced and explained. Namely, heat generating homogeneous vitrified HLW and heterogeneous compacted metallic MLW have been discussed. The advantages of a complementary numerical property simulation have been made clear and examples of benefits are presented. We have compiled a new program suite to calculate the physical and radio-chemical properties of common nuclear waste residues. The immediate benefit is the independent assessment of radio-active inventory declarations and much facilitated product quality control of waste residues that need to be returned to Germany and submitted to a German HLW-repository requirements. Wherever possible, internationally accepted standard programs are used and embedded. The innovative coupling of burn-up calculations (SCALE) with neutron and gamma transport codes (MCPN-X) allows an application in the world of virtual waste properties. If-then-else scenarios of hypothetical waste material compositions and distributions provide valuable information of long term nuclide property propagation under repository conditions over a very long time span. Benchmarking the program with real residue data demonstrates the power and remarkable accuracy of this numerical approach, boosting the reliability of the confidence aforementioned numerous applications, namely the proof tool set for on-the-spot production quality checking and data evaluation and independent verification. Moreover, using the numerical bottom-up approach helps to avoid the accumulation of fake activities that may gradually build up in a repository from the so-called conservative or penalizing nuclide inventory declarations. The radioactive waste properties and the hydrolytic and chemical stability can be predicted. The interaction with invasive chemicals can be assessed and propagation scenarios can be developed from reliable and sound data and HLW properties. Hence, the appropriate design of a future HLW repository can be based upon predictable and quality assured waste characteristics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface tension propellant acquisition system technology for Space Shuttle reaction control tanks

A program was conducted to provide the technology base for the SS/RCS flight tankage. Through a combination of analysis, subscale testing and computer predictions, a surface tension acquisition/expulsion system design was developed for the Orbiter RCS application. A full-scale tank system was fabricated and ground verification testing was conducted. Cleaning, inspection, fill and drain, and one-g expulsion performance were demonstrated. Results show that the fine-mesh screen, compartmented tank system provides the performance, flexibility, reusability, and other characteristics required by the pulsing, high flowrate RCS. It provides the required expulsion under widely differing high-g boost abort and reentry vectors oriented 119 deg apart and during on-orbit operation under omnidirectional low-g conditions.

Fester, D. A.↗

ASCR Workshop on In Situ Data Management: Enabling Scientific Discovery from Diverse Data Sources

In January 2019, the U.S. Department of Energy, Office of Science program in Advanced Scientific Computing Research, convened a workshop to identify priority research directions for in situ data management (ISDM). The workshop defined ISDM as the practices, capabilities, and procedures to control the organization of data and enable the coordination and communication among heterogeneous tasks, executing simultaneously in a high-performance computing system, cooperating toward a common objective. The workshop revealed two primary, interdependent motivations for processing and managing data in situ. The first motivation is that the in situ methodology enables scientific discovery from a broad range of data sources over a wide scale of computing platforms: leadership-class systems, clusters, clouds, workstations, and embedded devices at the edge. The successful development of ISDM capabilities will benefit real-time decision-making, design optimization, and data-driven scientific discovery. The second motivation is the need to decrease data volumes. ISDM can make critical contributions to managing large data volumes from computations and experiments to minimize data movement, save storage space, and boost resource efficiency, often while simultaneously increasing scientific precision. A fundamental finding of this workshop is that the methodologies used to manage data among a variety of tasks in situ can be used to facilitate scientific discovery from many different data sources—simulation, experiment, and sensors, for example—and that being able to do so at numerous computing scales will benefit real-time decision-making, design optimization, and data-driven scientific discovery across the Office of Science mission space. Applications wanting to use the in situ capabilities include those where data analysis feeds back to the simulation, decisions are made autonomously, big data or machine learning is among the tasks to be coordinated, and computations need to be completed in real time. The workshop identified six priority research directions that highlight the components and capabilities needed for ISDM to be successful for the wide variety of applications discussed: making ISDM capabilities more pervasive, controllable, composable, and transparent, with a focus on greater coordination with the software stack and a diversity of fundamentally new data algorithms.

97 MATHEMATICS AND COMPUTING↗

Orbiter aborts from boost: Presimulation report

A description of a hybrid simulation of the 040C orbiter aborting from boost to specified landing site is provided. The simulation starts when the abort is initiated and continues until a terminal energy state (associated with the selected landing site) is reached. At abort it is assumed that all SRM's are jettisoned with the external tank remaining with the orbiter. The simulation described has six degrees of freedom with the vehicle simulated as a rigid body. A conventional form of autopilot is provided to control engine gimbaling during powered flight. An ideal form of an autopilot is provided to test conventional autopilot function and provide pseudo RCS function during coasting flight. The simulation is proposed to provide means for studies of abort guidance function and to gain information concerning ability to control the abort trajectory.

Backman, H. D.↗

COSMIC: A Regimen of Intensity Modulated Radiation Therapy Plus Dose-Escalated, Raster-Scanned Carbon Ion Boost for Malignant Salivary Gland Tumors: Results of the Prospective Phase 2 Trial

Purpose: To investigate the effect of intensity modulated radiation therapy (IMRT) and dose-escalated carbon ion (C12) therapy in adenoid cystic carcinoma (ACC) and other malignant salivary gland tumors (MSGTs) of the head and neck. Patients and Methods: COSMIC (combined treatment of malignant salivary gland tumors with intensity modulated radiation therapy and carbon ions) is a prospective phase 2 trial of 24 Gy(RBE) C12 followed by 50 Gy IMRT in patients with pathologically confirmed MSGT. The primary endpoint is mucositis Common Terminology Criteria grade 3; the secondary endpoints are locoregional control (LC), progression-free survival (PFS), overall survival (OS), and toxicity. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3; treatment response was scored according to Response Evaluation Criteria in Solid Tumors 1.1. Results: Between July 2010 and August 2011, 54 patients were accrued, and 53 were available for evaluation. The median follow-up time was 42 months; patients with microscopically incomplete resections (R1, n=20), gross residual disease (R2, n=17), and inoperable disease (n=16) were included. Eighty-nine percent of patients had ACC, and 57% had T4 tumors. The most common primary sites were paranasal sinus (34%), submandibular gland, and palate. At the completion of radiation therapy, 26% of patients experienced grade 3 mucositis, and 20 patients reported adverse events of the ear (38%). The most common observed late effects were grade 1 xerostomia (49%), hearing impairment (25%, 2% ipsilateral hearing loss), and adverse events of the eye (20%), but no visual impairment or loss of vision. Grade 1 central nervous system necrosis occurred in 6%, and 1 grade 4 ICA hemorrhage without neurologic sequelae. The best response was 54% (complete response/partial remission). At 3 years, the LC, PFS, and OS were 81.9%, 57.9%, and 78.4%, respectively. No difference was found regarding resection status. The most common site of failure was distant (55%). Local relapse was predominantly in field (79%). Conclusion: Treatment was tolerated, with moderate acute and late toxicity. The LC at 3 years was promising. No significant difference could be shown regarding resection status; hence, extensive and mutilating surgical procedures should be rediscussed. Further dose escalation may be limited in view of potential vascular adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Once-Daily Radiation Therapy for Inflammatory Breast Cancer

Purpose: Inflammatory breast cancer (IBC) is a rare and aggressive breast cancer variant treated with multimodality therapy. A variety of approaches intended to escalate the intensity and efficacy of radiation therapy have been reported, including twice-daily radiation therapy, dose escalation, and aggressive use of bolus. Herein, we examine our outcomes for patients treated with once-daily radiation therapy with aggressive bolus utilization, focusing on treatment technique. Methods and Materials: A retrospective review of patients with nonmetastatic IBC treated from January 1, 2000, through December 31, 2010, was performed. Locoregional control (LRC), disease-free survival (DFS), overall survival (OS) and predictors thereof were assessed. Results: Fifty-two women with IBC were identified, 49 (94%) of whom were treated with neoadjuvant chemotherapy. All underwent mastectomy followed by adjuvant radiation therapy. Radiation was delivered in once-daily fractions of 1.8 to 2.25 Gy (median, 2 Gy). Patients were typically treated with daily 1-cm bolus throughout treatment, and 33 (63%) received a subsequent boost to the mastectomy scar. Five-year Kaplan Meier survival estimates for LRC, DFS, and OS were 81%, 56%, and 64%, respectively. Locoregional recurrence was associated with poorer OS (P<.001; hazard ratio [HR], 4.1). Extracapsular extension was associated with worse LRC (P=.02), DFS (P=.007), and OS (P=.002). Age greater than 50 years was associated with better DFS (P=.03). Pathologic complete response was associated with a trend toward improved LRC (P=.06). Conclusions: Once-daily radiation therapy with aggressive use of bolus for IBC results in outcomes consistent with previous reports using various intensified radiation therapy regimens. LRC remains a challenge despite modern systemic therapy. Extracapsular extension, age ≤50 years, and lack of complete response to chemotherapy appear to be associated with worse outcomes. Novel strategies are needed in IBC, particularly among these subsets of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy Management of Manned Boost-Glide Vehicles: A Historical Perspective

As flight progressed from propellers to jets to rockets, the propulsive energy grew exponentially. With the development of rocket-only boosted vehicles, energy management of these boost-gliders became a distinct requirement for the unpowered return to base, alternate landing site, or water-parachute landing, starting with the X-series rocket aircraft and terminating with the present-day Shuttle. The problem presented here consists of: speed (kinetic energy) - altitude (potential energy) - steep glide angles created by low lift-to-drag ratios (L/D) - distance to landing site - and the bothersome effects of the atmospheric characteristics varying with altitude. The primary discussion regards post-boost, stabilized glides; however, the effects of centrifugal and geopotential acceleration are discussed as well. The aircraft and spacecraft discussed here are the X-1, X-2, X-15, and the Shuttle; and to a lesser, comparative extent, Mercury, Gemini, Apollo, and lifting bodies. The footprints, landfalls, and methods developed for energy management are also described. The essential tools required for energy management - simulator planning, instrumentation, radar, telemetry, extended land or water range, Mission Control Center (with specialist controllers), and emergency alternate landing sites - were first established through development of early concepts and were then validated by research flight tests.

Day, Richard E.↗

Machine Learning Downscaling of SoilMERGE in the United States Southern Great Plains

SoilMERGE (SMERGE) is a root-zone soil moisture (RZSM) product that covers the entire continental United States and spans 1978 to 2019. Machine learning techniques, Random Forest (RF), eXtreme Gradient Boosting (XGBoost), and Gradient Boost (GBoost) downscaled SMERGE to spatial resolutions straddling the field scale domain (100 to 3000 m). Study area was northern Oklahoma and southern Kansas. The coarse resolution of SMERGE (0.125 degree) limits this product’s utility. To validate downscaled results in situ data from four sources were used that included: United States Department of Energy Atmospheric Radiation Measurement (ARM) observatory, United States Climate Reference Network (USCRN), Soil Climate Analysis Network (SCAN), and Soil moisture Sensing Controller and oPtimal Estimator (SoilSCAPE). In addition, RZSM retrievals from NASA’s Airborne Microwave Observatory of Subcanopy and Surface (AirMOSS) campaign provided a nearly spatially continuous comparison. Three periods were examined: era 1 (2016 to 2019), era 2 (2012 to 2015), and era 3 (2003 to 2007). During eras 1 and 2, RF outperformed XGBoost and GBoost, whereas during era 3 no model dominated. Performance was better during eras 1 and 2 as opposed to the pre-L band era 3. Improvements across all eras, regions, and models realized from downscaling included an increase in correlation from 0.03 to 0.42 and a decrease in ub RMSE from -0.0005 to -0.0118 m 3 /m 3 . This study demonstrates the feasibility of SMERGE downscaling opening the prospect for the development of a long-term RZSM dataset at a more desirable field-scale resolution with the potential to support diverse hydrometeorological and agricultural applications.

54 ENVIRONMENTAL SCIENCES↗

Coordinated balancing of muscle oxidative metabolism through PGC-1{alpha} increases metabolic flexibility and preserves insulin sensitivity

Highlights: {yields} PGC-1{alpha} enhances muscle oxidative capacity. {yields} PGC-1{alpha} promotes concomitantly positive and negative regulators of lipid oxidation. {yields} Regulator abundance enhances metabolic flexibility and balances oxidative metabolism. {yields} Balanced oxidation prevents detrimental acylcarnitine and ROS generation. {yields} Absence of detrimental metabolites preserves insulin sensitivity -- Abstract: The peroxisome proliferator-activated receptor {gamma} coactivator 1{alpha} (PGC-1{alpha}) enhances oxidative metabolism in skeletal muscle. Excessive lipid oxidation and electron transport chain activity can, however, lead to the accumulation of harmful metabolites and impair glucose homeostasis. Here, we investigated the effect of over-expression of PGC-1{alpha} on metabolic control and generation of insulin desensitizing agents in extensor digitorum longus (EDL), a muscle that exhibits low levels of PGC-1{alpha} in the untrained state and minimally relies on oxidative metabolism. We demonstrate that PGC-1{alpha} induces a strictly balanced substrate oxidation in EDL by concomitantly promoting the transcription of activators and inhibitors of lipid oxidation. Moreover, we show that PGC-1{alpha} enhances the potential to uncouple oxidative phosphorylation. Thereby, PGC-1{alpha} boosts elevated, yet tightly regulated oxidative metabolism devoid of side products that are detrimental for glucose homeostasis. Accordingly, PI3K activity, an early phase marker for insulin resistance, is preserved in EDL muscle. Our findings suggest that PGC-1{alpha} coordinately coactivates the simultaneous transcription of gene clusters implicated in the positive and negative regulation of oxidative metabolism and thereby increases metabolic flexibility. Thus, in mice fed a normal chow diet, over-expression of PGC-1{alpha} does not alter insulin sensitivity and the metabolic adaptations elicited by PGC-1{alpha} mimic the beneficial effects of endurance training on muscle metabolism in this context.

60 APPLIED LIFE SCIENCES↗

Once-Weekly, High-Dose Stereotactic Body Radiotherapy for Lung Cancer: 6-Year Analysis of 60 Early-Stage, 42 Locally Advanced, and 7 Metastatic Lung Cancers

Purpose: To explore once-weekly stereotactic body radiotherapy (SBRT) in nonoperable patients with localized, locally advanced, or metastatic lung cancer. Methods and Materials: A total of 102 primary (89 untreated plus 13 recurrent) and 7 metastatic tumors were studied. The median follow-up was 38 months, the average patient age was 75 years. Of the 109 tumors studied, 60 were Stage I (45 IA and 15 IB), 9 were Stage II, 30 were Stage III, 3 were Stage IV, and 7 were metastases. SBRT only was given in 73% (40 Gy in four fractions to the planning target volume to a total dose of 53 Gy to the isocenter for a biologically effective dose of 120 Gy{sub 10}). SBRT was given as a boost in 27% (22.5 Gy in three fractions once weekly for a dose of 32 Gy at the isocenter) after 45 Gy in 25 fractions to the primary plus the mediastinum. The total biologically effective dose was 120 Gy{sub 10}. Respiration gating was used in 46%. Results: The overall response rate was 75%; 33% had a complete response. The overall response rate was 89% for Stage IA patients (40% had a complete response). The local control rate was 82%; it was 100% and 93% for Stage IA and IB patients, respectively. The failure rate was 37%, with 17% within the planning target volume. No Grade 3-4 acute toxicities developed in any patient; 12% and 7% of patients developed Grade 1 and 2 toxicities, respectively. Late toxicity, all Grade 2, developed in 3% of patients. The 5-year cause-specific survival rate for Stage I was 70% and was 74% and 64% for Stage IA and IB patients, respectively. The 3-year Stage III cause-specific survival rate was 30%. The patients with metastatic lung cancer had a 57% response rate, a 27% complete response rate, an 86% local control rate, a median survival time of 19 months, and 23% 3-year survival rate. Conclusions: SBRT is noninvasive, convenient, fast, and economically attractive; it achieves results similar to surgery for early or metastatic lung cancer patients who are older, debilitated, and with comorbidities. Elderly patients and/or patients medically unfit for combined modality therapy with locally advanced disease can find an effective palliative alternative in SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

Physics Contributions and Clinical Outcome With 3D-MRI-Based Pulsed-Dose-Rate Intracavitary Brachytherapy in Cervical Cancer Patients

Purpose: To assess the physics contributions and clinical outcome with three-dimensional magnetic resonance imaging-guided pulsed-dose-rate (PDR) intracavitary brachytherapy in cervical cancer patients. Methods and Materials: The data from 45 patients with primary locally advanced cervical carcinoma were analyzed. The median tumor cervical volume was 64.0 cm{sup 3} (range, 3-178). Of the 45 patients, 24 (53%) had histologic and/or radiologic pelvic involvement. After pelvic with or without para-aortic concomitant chemoradiotherapy, a PDR brachytherapy boost was delivered to a three-dimensional magnetic resonance imaging-based clinical target volume, taking into account the dose-volume constraints for critical organs and optimization of the target volume coverage. Results: At a median follow-up of 26 months (range, 9-47), the 2-year overall survival and disease-free survival rate was 78% and 73%, respectively. At the last follow-up visit, the disease of all patients remained locally controlled. Adding external beam radiotherapy and PDR using the equivalent dose in 2-Gy fractions model, the median dose received by 100% and 90% of the target was 54.4 Gy{sub {alpha}}{sub /{beta}}{sub 10} and 63.5 Gy{sub {alpha}}{sub /{beta}}{sub 10} for the intermediate-risk clinical target volume and 61.6 Gy{sub {alpha}}{sub /{beta}}{sub 10} and 74.9 Gy{sub {alpha}}{sub /{beta}}{sub 10} for the high-risk clinical target volume, respectively. Of the 45 patients, 23 and 2 developed acute Grade 1-2 and Grade 3 complications, respectively; 21 patients presented with delayed Grade 1-2 complications. One other patient presented with Grade 3 vesicovaginal fistula. No Grade 4 or greater complications, whether acute or delayed, were observed. Conclusion: Magnetic resonance imaging-guided PDR brachytherapy with optimization integrating the limits of tolerance to critical organs allows for excellent local control rates. Moreover, the present results have confirmed that the ability to optimize dwell times can contribute to an improvement in local control rates with a low level of late side effects.