Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Development of a MEMS dual-axis differential capacitance floating element shear stress sensor

A single-axis MEMS wall shear stress sensor with differential capacitive transduction method is produced. Using a synchronous modulation and demodulation interface circuit, the system is capable of making real time measurements of both mean and fluctuating wall shear stress. A sensitivity of 3.44 mV/Pa is achieved, with linearity in response demonstrated up to testing limit of 2 Pa. Minimum detectable signals of 340 μPa at 100 Hz and 120 μPa at 1 kHz are indicated, with a resonance of 3.5 kHz. Multiple full scale wind tunnel tests are performed, producing spectral measurements of turbulent boundary layers in wind speeds ranging up to 0.5 Ma (18 Pa of mean wall shear stress). The compact packaging allows for minimally invasive installation, and has proven relatively robust over multiple testing events. Temperature sensitivity, likely due to poor CTE matching of packaged materials, is an ongoing concern being addressed. These successes are being directly leveraged into a development plan for a dual-axis wall shear stress sensor, capable of producing true vector estimates at the wall.

47 OTHER INSTRUMENTATION↗

The Implementation Of Solid State Switches In A Parallel Configuration To Gain Output Current Capacity In A High Current Capacitive Discharge Unit (CDU).

For my project I have selected to research and design a high current pulse system, which will be externally triggered from a 5V pulse. The research will be conducted in the region of paralleling the solid state switches for a higher current output, as well as to see if there will be any other advantages in doing so. The end use of the paralleled solid state switches will be used on a Capacitive Discharge Unit (CDU). For the first part of my project, I have set my focus on the design of the circuit, selection of components, and simulation of the circuit.

42 ENGINEERING↗

Interdigital Capacitance Local Non-Destructive Examination of Nuclear Power Plant Cable for Aging Management Programs

This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of non-destructive test methods focusing on local cable insulation and jacket testing using an interdigital capacitance (IDC) approach. Earlier studies have assessed a number of non-destructive examination (NDE) methods for bulk, distributed, and local cable tests. A typical test strategy is to perform bulk assessments of the cable response using dielectric spectroscopy, Tan , or partial discharge followed by distributed tests like time domain reflectometry or frequency domain reflectometry to identify the most likely defect location followed by a local test that can include visual inspection, indenter modulus tests, or Fourier Transform Infrared Spectroscopy (FTIR) or Near Infrared Spectroscopy FTIR (FTNIR). If a cable is covered with an overlaying jacket, the jacket’s condition is likely to be more severely degraded than the underlying insulation. None of the above local test approaches can be used to evaluate insulation beneath a cable jacket. Since the jacket’s function is neither structural nor electrical, a degraded jacket may not have any significance regarding the cable’s performance or suitability for service. IDC measurements offer a promising alternative or complement to these local test approaches including the possibility to test insulation beneath an overlaying jacket.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Pore Size on Na/Ca Ion Selectivity Using Flow Through Electrode Capacitive Deionization

In flow through electrode capacitive deionization (fte-CDI), low salinity brackish water flows through two porous carbon electrodes. When an electrical potential difference is applied over the electrodes, ions migrate towards micropores, cleaning the water. Ion selectivity can be controlled by taking advantage of charge and ionic radius differences as well as the applied potential and pore size of the electrodes. The research outlined in this paper consists primarily of running fte-CDI cells with electrodes of varying pore size distributions to experimentally determine the parameters for optimal total salt removal and sodium/calcium ion selectivity. Five fte-CDI cells of different activation were fabricated using microporous hierarchical carbon aerogel materials (HCAMs) as electrodes. For each cell, cyclic voltammetry using 20 mM NaCl solution and 10 mM CaCl2 solution was performed at a scan rate of 0.5, 0.75, and 1 mV/s with a potential window from -0.8 V to +0.8 V. The same pure salts were desalinated in hourly charge/discharge cycles at ±1 V. A mixture of 5 mM NaCl and 2.5 mM CaCl2 was desalinated at 0.6, 0.8, 1.0, and 1.2 V. The collected charge and discharge streams were analyzed with ion chromatography (IC). The IC data for the two least activated cells showed minimal calcium adsorption compared to sodium. All cells adsorbed sodium, regardless of activation, while only highly activated cells removed calcium. This data indicates a tradeoff between more total salt removed at high voltages and selectivity of sodium over calcium at low voltages. Future research with nitrogen porosimetry could provide a quantitative value for the optimal pore size distribution.

36 MATERIALS SCIENCE↗

Kinetic Modeling and Experimental Studies of Capacitively Coupled Macro- and Microplasmas at Microwave Frequencies

The effect of driving frequency in the range of 13.56 MHz to 73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct temperatures for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2 eV to 10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25 % of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically-derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthesis of Microscopic 3D Graphene for High-Performance Supercapacitors with Ultra-High Areal Capacitance

This presentation was given at the 2024 AIChE Annual Meeting, San Diego, CA, October 27-31, 2024. This presentation describes a low-cost and scalable method to convert coal tar pitch into high-quality 3D graphene with high surface area, hierarchical pore size distribution, and high electrical conductivity which allows for the creation of supercapacitor electrodes with ultra-high mass loading (30 mg/cm2), leading to ultra-high areal capacitance.

Pham, Viet Hung↗

High-Fidelity Computational Studies of Intermediate Pressure Capacitively Coupled Plasmas

This report discussed progress made in the development of a computational model for intermediate pressure capacitively coupled plasma discharge. A new full fidelity argon chemistry model has been developed that includes electron, argon ion, three lumped states for electronically excited species, and the background ground state argon. As such the mechanism has been validated over a wide range of intermediate pressure conditions from 100 mTorr to a few Torr. Uncertainties in the electron impact cross sections and the rate coefficients for the reactions are propagated through the model to establish uncertainties that emerge in the model due the reaction mechanism and its impact on the discharge properties. The model is therefore validated in face of uncertainties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methylated Poly(ethylene)imine Modified Capacitive Micromachined Ultrasonic Transducer for Measurements of CO2 and SO2 in Their Mixtures

A gravimetric gas detection device based on surface functionalized Capacitive Micromachined Ultrasound Transducers (CMUTs) was designed, fabricated and tested for detection of carbon dioxide (CO2) and sulfur dioxide (SO2) mixtures in nitrogen. The created measurement setup of continuous data collection, integrated with an in-situ Fourier Transform Infrared (FT-IR) spectroscopy, allows for better understanding of the mechanisms and molecular interactions with the sensing layer (methylated poly(ethylene)imine) and its need of surface functionalization for multiple gas detection. During experimentation with CO2 gases, weak molecular interactions were observed in spectroscopy data. Linear sensor response to frequency shift was observed with CO2 concentrations ranging from 0.16 vol % to 1 vol %. Moreover, the Raman and FT-IR spectroscopy data showed much stronger SO2 and the polymer interactions, molecules were bound by stronger forces and irreversibly changed the polymer film properties. However, the sensor change in resonance frequency in the tested region of 1 vol % to 5 vol % SO2 showed a linear response. This effect changed not only the device resonance frequency but also affected the magnitude of electroacoustic impedance which was used for differentiating the gas mixture of CO2, SO2, in dry N2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of Zeolitic Imidazolate Framework-8-Functionalized Capacitive Micromachined Ultrasound Transducer Gravimetric Sensors for Gas and Hydrocarbon Vapor Detection

A capacitive micromachined ultrasound transducer (CMUT) was engineered and functionalized with zeolitic imidazolate framework-8 (ZIF-8) dispersed in a photoresist AZ1512HS (AZ) matrix to function as a gravimetric gas sensor. The sensor response was recorded in the presence of nitrogen, argon, carbon dioxide, and methane gases as well as water, acetylene, a propane/butane mixture, n-hexane, gasoline, and diesel vapors. The photoresist matrix alone was found to have a negligible response to all the gases and vapors, except for water vapor. No visible difference in sensor response was detected when switching from nitrogen to methane gas. However, a strong shift in the sensor resonance frequency was observed when exposed to higher hydrocarbons, ranging from 1 kHz for acetylene to 7.5 kHz for gasoline. Even longer-chain hydrocarbons, specifically kerosene and more so diesel, had a significantly reduced sensor frequency shift compared with gasoline. Sensors functionalized with a thin film of AZ+ZIF-8 demonstrated higher sensitivity in their response to a hydrocarbon molecular mass than without functionalization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical capacitance as a predictor of root dry weight in shrub willow ( Salix ; Salicaceae) parents and progeny

Premise of the study: Root biomass is an important trait often disregarded in woody perennial selection due to the challenge and expense of accurately and efficiently measuring large populations. In this study, we aim to develop a simple method that can predict root dry weight within a diverse shrub willow ( Salix ) breeding population representing species hybrids and their parents using root electrical capacitance (REC). Methods: The REC method was tested on plants started from cuttings and grown in pots with potting mix in the greenhouse for 11 wk to assess the relationship of REC with 24 biomass traits and its usefulness in allometric models for root and stem dry biomass. Results: Strong linear and positive correlations were found between REC and root dry biomass ( r = 0.88). The total proportion of variance of root and stem dry biomass explained by predictors in multiple regression was 85% and 69%, respectively. The relative importance of predictor variables in allometric models was dominated by the contribution of REC. Discussion: This work provides an efficient and nondestructive technique to indirectly quantify root biomass of genetically diverse shrub willow progeny, which has great promise for selection of genotypes with varying root biomass and for the accurate estimation of belowground carbon sequestration.

59 BASIC BIOLOGICAL SCIENCES↗

Capacitive de-ionization electrode

An electrode "cell" for use in a capacitive deionization (CDI) reactor consists of the electrode support structure, a non-reactive conductive material, the electrode accompaniment or substrate and a flow through screen/separator. These "layers" are repeated and the electrodes are sealed together with gaskets between two end plates to create stacked sets of alternating anode and cathode electrodes in the CDI reactor.

42 ENGINEERING↗

Shielded capacitive electrode

A device is described, which is sensitive to electric fields, but is insensitive to stray electrons/ions and unlike a bare, exposed conductor, it measures capacitively coupled current while rejecting currents due to charged particle collected or emitted. A charged particle beam establishes an electric field inside the beam pipe. A grounded metallic box with an aperture is placed in a drift region near the beam tube radius. The produced electric field that crosses the aperture generates a fringe field that terminates in the back surface of the front of the box and induces an image charge. An electrode is placed inside the grounded box and near the aperture, where the fringe fields terminate, in order to couple with the beam. The electrode is negatively biased to suppress collection of electrons and is protected behind the front of the box, so the beam halo cannot directly hit the electrode and produce electrons. The measured signal shows the net potential (positive ion beam plus negative electrons) variation with time, as it shall be observed from the beam pipe wall.

42 ENGINEERING↗

RF-MEMS capacitive switches with high reliability

A reliable long life RF-MEMS capacitive switch is provided with a dielectric layer comprising a "fast discharge diamond dielectric layer" and enabling rapid switch recovery, dielectric layer charging and discharging that is efficient and effective to enable RF-MEMS switch operation to greater than or equal to 100 billion cycles.

42 ENGINEERING↗

Capacitance-Based Dimensional Change Sensors for In-Pile Materials Measurements

Advanced fuel compositions, such as accident tolerate fuels (ATF), are an active area of developing in the nuclear power industry. The long-term performance of these newly developed fuels is estimated through physics-based simulation models of irradiation-, temperature-, pressure-, etc.-induced material degradation. As these fuels are deployed in test reactors, measurement and characterization of the fuel pin evolution is used to validate prediction models. In-pile material evolution parameters, such as fuel rod pressurization, fuel stack and cladding elongation, and cladding diameter, are commonly measured using a linear voltage differential transformer (LVDT). However, LVDTs are bulky and limited to lower (350-500C) temperature operation. The high power density and small size of most experimental positions in high performance research reactors used for accelerated materials irradiation studies generally precludes the use of LVDTs in these reactors. There is a critical need for sensors that provide real-time data regarding material evolution under highly accelerated irradiation. These sensors would ideally have a small profile and the ability to withstand irradiation at extremely high dose rates and temperatures for extended periods of time. A capacitance-based sensor is currently under development at the University of Tennessee to provide a direct measurement of in-pile dimensional change during irradiation. Sensor response was simulated using AutoCAD Electromagnetic field simulator (EMS) for a variety of sensor materials and configurations and fuel pin swelling conditions. Initial results of these simulations are summarized and areas of ongoing research and development are discussed.

Naughton, Tyler↗

Multiple pulse charge transfer for capacitive deionization of a fluid

The present disclosure relates to a capacitive deionization system which makes use of a controller, a first capacitor acting as a first electrode, a second capacitor acting as a second electrode, and a first inductor for storing energy received from the first capacitor, and transferring the stored energy to the second capacitor. A first plurality of electronic switches are controlled by the controller to control communication between the first inductor and the first capacitor, and between the first inductor and the second capacitor. An additional energy transfer subsystem is included which has a second inductor for receiving energy from the first capacitor while the first inductor is transferring stored energy to the second capacitor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Printed hygroscopic electrodes for low-cost capacitive relative humidity sensors

A capacitive relative humidity sensor includes a first electrode and a second electrode, where at least the one of the electrodes is a water-permeable electrode. The electrodes act in conjunction with a water-sensitive hygroscopic dielectric material. The design enables low-cost and simple fabrication of fast-responding and stable relative humidity sensors using digital fabrication techniques.

Pierre, Adrien↗