Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Simple gas chromatographic system for analysis of microbial respiratory gases

Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

Carle, G. C.↗

Stabilization of porous glass reverse-osmosis membranes

Application of porous glass in form of capillary tubes for low capacity ion exchange in hyperfiltration experiments is discussed. Efficiency of desalination by process of reverse osmosis is described. Stabilization of porous glass membrane by presence of aluminum chloride is analyzed.

Ballou, E. V.↗

A research on integrated-circuit sensors for gas chromatography

Fabrication of a miniature gas chromatograph column using integrated circuit technology was studied and found to be feasible. A bonding problem of forming a strong, gas tight seal between two wafers of silicon has prevented the completion of the column design. Continuing research using tin or a chromium-gold bond promises to overcome the problems of using the proposed gold-eutectic bond. Specifications for the miniature gas chromatograph column are: a spiral capillary column of semi-circular cross section, 30 micron radius, and a total length of 6.9 meters etched into a silicon structure 50 mm in diameter and 0.625 mm thick.

Source record↗

Mechanisms of deterioration of intermediate moisture food systems

A study of shelf stability in intermediate moisture foods was made. Major efforts were made to control lipid oxidation and nonenzymatic browning. In order to determine means of preventing these reactions, model systems were developed having the same water activity content relationship of intermediate moisture foods. Models were based on a cellulose-lipid and protein-lipid system with glycerol added as the humectant. Experiments with both systems indicate that lipid oxidation is promoted significantly in the intermediate moisture range. The effect appeared to be related to increased mobility of either reactants or catalysts, since when the amount of water in the system reached a level where capillary condensation occurred and thus free water was present, the rates of oxidation increased. With added glycerol, which is water soluble and thus increases the amount of mobile phase, the increase in oxidation rate occurs at a lower relative humidity. The rates of oxidation were maximized at 61% RH and decreased again at 75% RH probably due to dilution. No significant non-enzymatic browning occurred in the protein-lipid systems. Prevention of oxidation by the use of metal chelating agents was enhanced in the cellulose system, whereas, with protein present, the lipid soluble chain terminating antioxidants (such as BHA) worked equally as well. Preliminary studies of foods adjusted to the intermediate moisture range bear out the results of oxidation in model systems. It can be concluded that for most fat containing intermediate moisture foods, rancidity will be the reaction most limiting stability.

Labuza, T. P.↗

Surface tensions of propellants

An apparatus is described for determining the surface tension of propellants by measuring the maximum bubble pressure using two capillaries of different bores. The innovation is the use of a pressure transducer coupled to a bridge supply and a strip chart recorder for registering the development of the pressure difference as the bubble is formed and released. This enables the measurements to be made under controlled atmospheres and to be remotely operated. Preliminary experiments were done on propellant-grade hydrazine and monomethylhydrazine, and on purified hydrazine, at temperatures between 275.4 and 353.2 K. Straight-line expressions and logarithmic expressions reproduce equally well the variation of surface tension with temperature. Contaminated hydrazine, pre-exposed to coupons of 6Al-4V titanium alloy for long periods, gives slightly higher values of surface tension.

Razouk, R.↗

Detection of oil spills using 13.3 GHz radar scatterometer

The results of an analysis of 13.3-GHz single polarized scatterometer data collected during NASA/MSC Mission 135, flown on March 16, 1970 are reported. Data were gathered over a crude oil spill on the Gulf of Mexico off the Mississippi Delta. With the aid of RC-8 camera photographs, the scattering cross section was correlated with the extent of the oil spill. The scattering cross section at higher incidence angles decreased by 5 db to 10 db in the presence of the oil spill. This was attributed to oil's damping of small gravity and capillary waves. The composite scattering theory and the scatterometer acquired data were used to obtain an expression of radar scattering over ocean surfaces with oil spills. The study demonstrates that the presence and extent of oil spills can be detected using high frequency radar systems.

Krishen, K.↗

Laboratory investigations related to microwaves

The investigation in a laboratory controlled environment was of the structure of the water surface and the immediate layers above and below the surface. The scope included: (1) the investigation of the capillary waves and their interaction with gravity waves, (2) the formation of whitecaps at different wind speeds and the influence of gravity waves on whitecaps, and (3) the wind-generated spray under different wind and wave conditions.

Shemdin, O. H.↗

The extrapolation of laboratory and aircraft radar sea return data to spacecraft altitudes

Laboratory measurements show that the spectra of capillary waves grow with wind speed over six orders of magnitude. The scatter in the data can be partially understood and predicted from a combination of turbulence theory, radar theory, and the small sample theory of statistical inference. When these results are applied to a prediction of the sea return values to be obtained by S193 on Skylab, it can be shown that the size of the illuminated patch effectively averages out the horizontal scales of gustiness, so that the measurement will correspond to the synoptic scale wind.

Pierson, W. J.↗

Thick film silicon growth techniques

Thick film silicon ribbons were produced by means of the edge-defined, film-fed growth (EFG) technique. EFG is a process by which single crystals may be grown having a shape controlled by the outside dimensions of a die, the growth taking place from an extremely thin film of liquid fed by capillary action from a crucible below. The principal problem to be overcome in the application of this process to the growth of thick film silicon ribbon relates to the material, such as the shaping die. For the method to operate, this die material must be wet by the liquid silicon. To preserve semiconductor quality, the liquid silicon must not react significantly with the die material. The most promising die material for this application appears to be SiC and SiC-SiO2 admixture. In this case good wetting occurs between the molten silicon and the SiC. C is a relatively unharmful contaminant of Si and additions of quartz to SiC are found to decrease the extent of reaction.

Bates, H. E.↗

Mass spectrometric determination of the composition of the Venus clouds

The design of a mass spectrometer, based on the results of the Venera and Mariner probes, with sensitivity high enough to detect the HCl in the Venus atmosphere is discussed. One way to analyze the clouds is by the introduction of the atmosphere with cloud particles through a molecular leak into the mass spectrometer. The analysis can be performed in regular Nier-type ion sources with the electrodes of materials which are completely free of Cl and F. The problem of preventing the blockage of the capillaries to the Nier type ion source is also considered.

Source record↗

Generation of a uranium plasma at near gaseous core reactor conditions.

A constricted sliding spark discharge is used to generate a high density, high temperature uranium plasma. Uranium particle densities up to 10 to the 20th power per cu cm are obtained over a temperature range of 30,000 to 50,000 K. The device consists of a capillary discharge channel lined with pressed and sintered UO2. A 250 joule capacitor bank is discharged into the channel, producing a plasma of 10-20 microsec duration. Spectroscopic observations are made over the spectral range of 1300 to 2500 A.

Davis, J. F., III↗

Shuttle operations, maintenance, and safety.

Review of a systematic search for practical solutions in the areas of space shuttle cryogenics, flight operations, ground operations, and safety. The insulation of the main-propulsion hydrogen tanks for both booster and orbiter to prevent water condensation is considered, as well as the insulation of the orbiter's orbital cryogen tanks for ground storage. Two approaches to the feeding of cryogens are outlined - namely, an approach depending on a periodic axial force to settle propellants and refill the basket, and a method of continuous feed through a capillary network adjacent to the walls throughout the tank, the latter method being independent of vehicle thrust. The development of reliable cryogen components is discussed, and the results of studies of launch-abort problems, shuttle approach and landing techniques, and the tolerance of ?deconditioned' crew and passengers to shuttle reentry g-loads are cited.

Beddingfield, S. T.↗

Fast-acting self-healing metallic fuse.

Description of a fast-acting nonmechanical self-healing mercury fuse capable of protecting a high current circuit or device from overcurrent fault damages. Basically the self-healing fuse consists of two enclosed mercury reservoirs connected by a fine capillary tube filled with mercury that serves as the fusing element. It is pointed out that a better understanding of the energy conversion process involved in the operation of the device could help explore other device configurations (such as a tapering geometry and use of magnetic field to drive the arc into the fuse wall on inductive loads, etc.) and thus extend the range of capabilities for this type of protective device.

Schwartz, F. C.↗

Experimental investigation of two-phase heat transfer in a porous matrix.

One-dimensional two-phase flow transpiration cooling through porous metal is studied experimentally. The experimental data is compared with a previous one-dimensional analysis. Good agreement with calculated temperature distribution is obtained as long as the basic assumptions of the analytical model are satisfied. Deviations from the basic assumptions are caused by nonhomogeneous and oscillating flow conditions. Preliminary derivation of nondimensional parameters which characterize the stable and unstable flow conditions is given. Superheated liquid droplets observed sputtering from the heated surface indicated incomplete evaporation at heat fluxes well in access of the latent energy transport. A parameter is developed to account for the nonequilibrium thermodynamic effects. Measured and calculated pressure drops show contradicting trends which are attributed to capillary forces.

Von Reth, R.↗

Solute rejection by porous glass membranes. I - Hyperfiltration of sodium chloride and urea feed solutions.

Hyperfiltration of sodium chloride and urea was studied with porous glass membranes in closed-end capillary form, to determine the effect of pressure, temperature, and concentration variations, and lifetime rejection and flux characteristics. Rejection data for sodium chloride were consistent with the functioning of the porous glass as a low-capacity ion-exchange membrane.

Ballou, E. V.↗

Airway structure and alveolar emptying in the lungs of sea lions and dogs.

Investigation of the effects of various cycles of compression and decompression on the alveolar volumes of the excised lungs of sea lions and dogs. The results obtained include the finding that, in comparison to dog lungs, sea lion lungs empty more completely on mild compression and much more completely on severe compression. These findings support Scholander's (1940) hypothesis that some marine mammals are protected from decompression sickness by cartilaginous reinforcement of the small airways which permits alveolar emptying during a dive, so isolating compressed gas from pulmonary capillary blood.

Denison, D. M.↗