Search NASA⌕ Search

SEARCH · Search NASA

Results for “code requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Investigating Short Circuit Models for Wind Turbine Generators

Short circuit study needs to be performed at the planning stage before connecting large gen erators with the electric grid. This study will reveal the impact of new generation on the fault levels of the grid. The fault levels will determine the rating of nearby equipment and setting of relays. However, a short circuit model of the new generation is required for this study. This report investigates and quantifies the short circuit models of different wind turbine generators (WTGs) and of wind farms, and using these models, explores the effects of the wind farms on the nearby switchgear. WTGs, commonly classified as Type 1, Type 2, Type 3, and Type 4, exhibit different short circuit behavior depending upon their architecture and controls. The short circuit model (synonymous to Thevenin model) of Type 1 WTG is well known; it comprises of a voltage source behind a transient reactance, X'. The transient reactance X' is derived using the reactance of stator, rotor and the magnetizing reactance. In case of Type 2 WTG, an external rotor resistance is used to increase the range of operating slips. The value of the external rotor resistance increases at higher operating slips. The effect of the external rotor resistance on the fault current response is analyzed by simulating a validated model of Type 2 WTG. The validation is performed using the field data from an actual 67-machine Type 2 wind farm located in Wyoming, USA. The results shows that the external rotor resistance should be considered in its Thevenin impedance for better accuracy. A wind farm contains a large number of WTGs, pad mounted transformers, and cables typically connected in a ‘daisy chain” configuration. The effect of these cable impedances on the short circuit model of Type 2 wind farm is examined using the validated models. It is found that the collector circuit cables inside the farm do not have a significant effect on the short circuit model of the farm. Based on this finding, a simple equivalencing procedure for the wind farm is proposed and validated. Faults inside and outside the wind farm are analyzed and recommendations to select main circuit breakers and generator circuit breakers are made. Type 3 WTG, also known as Doubly Fed Asynchronous Generator (DFAG), uses back to back converters in the rotor circuit to inject slip frequency voltage into the rotor circuit. Until recently, these machines used crowbar to short the rotor circuit during faults to protect the converter com ponents form high rotor currents resulting from faults. This type of WTG is simulated and the model is validated using field data from a 66-machine Type 3 wind farm in Wyoming, USA. The simulation study reveals that the crowbar feature is activated almost immediately after the fault takes place, and remains activated throughout the fault-period. This confirms that the short circuit model for Type 3 WTG with crowbar is similar to the model for Type 2 WTG. In the past, wind farms were allowed to disconnect during faults. However, recent grid codes around the world and in the United States demand that the wind farms be kept connected to the grid during faults, and provide certain reactive power quantified based on the voltage dip at the point of interconnection. This requirement, also called low voltage ride through (LVRT), can be accomplished by using Type 4 WTGs that employ full back to back converter interface between generators (permanent magnet synchronous generators are typically used) and the grid. However, the controls are proprietary, and hence the short circuit models are not well defined. This report proposes controls that enable the WTG to comply with the strictest grid codes, and based on this model, proposes a short circuit model of the Type 4 WTG. This model is not validated due to lack of validation data, but the use of grid code requirements as control objectives lends good credibility to the model. PSCAD/EMTDC ® , a powerful and time-tested time-domain simulation software is used to implement all models. This software is capable of modeling in detail all components of wind farms, and all components and controls of converters in time domain.

17 WIND ENERGY↗

SIM-RIBRAS: A Monte-Carlo simulation package for RIBRAS system

SIM-RIBRAS is a Root-based Monte-Carlo simulation tool designed to help RIBRAS users on experience planning and experimental setup enhancing and caracterization. It is divided into two main programs: CineRIBRAS, aiming beam kinematics, and SolFocus, aiming beam optics. SIM-RIBRAS replaces other methods and programs used in the past, providing more complete and accurate results and requiring much less manual labour. Moreover, the user can easily make modifications in the codes, adequating it for specific requirements of an experiment.

43 PARTICLE ACCELERATORS↗

Gap Analysis of Material Properties Data for Ferritic/Martensitic HT-9 Steel

The US Department of Energy (DOE), Office of Nuclear Energy (NE), is supporting the development of an ASME Code Case for adoption of 12Cr-1Mo-VW ferritic/martensitic (F/M) steel, commonly known as HT-9, primarily for use in elevated temperature design of liquid-metal fast reactors (LMFR) and components. In 2011, Los Alamos National Laboratory (LANL) nuclear engineering staff began assisting in the development of a small modular reactor (SMR) design concept, previously known as the Hyperion Module, now called the Gen4 Module. LANL staff immediately proposed HT-9 for the reactor vessel and components, as well as fuel clad and ducting, due to its superior thermal qualities. Although the ASME material Code Case, for adoption of HT-9 as an approved elevated temperature material for LMFR service, is the ultimate goal of this project, there are several key deliverables that must first be successfully accomplished. The most important key deliverable is the research, accumulation, and documentation of specific material parameters; physical, mechanical, and environmental, which becomes the basis for an ASME Code Case. Time-independent tensile and ductility data and time-dependent creep and creep-rupture behavior are some of the material properties required for a successful ASME Code case. Although this report provides a cursory review of the available data, a much more comprehensive study of open-source data would be necessary. This report serves three purposes: (a) provides a list of already existing material data information that could ultimately be made available to the ASME Code, (b) determines the HT-9 material properties data missing from available sources that would be required and (c) estimates the necessary material testing required to close the gap. Ultimately, the gap analysis demonstrates that certain material properties testing will be required to fulfill the necessary information package for an ASME Code Case.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Directed Evolution Reveals the Functional Sequence Space of an Adenylation Domain Specificity Code

Nonribosomal peptides are important natural products biosynthesized by nonribosomal peptide synthetases (NRPSs). Adenylation (A) domains of NRPSs are highly specific for the substrate they recognize. This recognition is determined by 10 residues in the substrate-binding pocket, termed the specificity code. This finding led to the proposal that nonribosomal peptides could be altered by specificity code swapping. Unfortunately, this approach has proven, with few exceptions, to be unproductive; changing the specificity code typically results in broadened specificity or poor function. To enhance our understanding of A domain substrate selectivity, we carried out a detailed analysis of the specificity code from the A domain of EntF, an NRPS involved in enterobactin biosynthesis in Escherichia coli. Using directed evolution and a genetic selection, we determined which sites in the code have strict residue requirements and which are tolerant of variation. We showed that the EntF A domain, and other l-Ser-specific A domains, have a functional sequence space for l-Ser recognition, rather than a single code. This functional space is more expansive than the aggregate of all characterized l-Ser-specific A domains: we identified 152 new l-Ser specificity codes. Together, our data provide essential insights into how to overcome the barriers that prevent rational changes to A domain specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel features and GPU performance analysis for EM particle transport in the Celeritas code

Celeritas is a new computational transport code designed for high-performance simulation of high-energy physics detectors. This work describes some of its current capabilities and the design choices that enable the rapid development of efficient on-device physics. The abstractions that underpin the code design facilitate low-level performance tweaks that require no changes to the higher-level physics code. We evaluate a set of independent changes that together yield an almost 40% speedup over the original GPU code for a net performance increase of 220× for a single GPU over a single CPU running 8.4M tracks on a small demonstration physics app.

Johnson, Seth R.↗

CTT: Tools for Fine Alignment of Flash X-ray Systems

The CTT code is a compilation of the python code that was prototyped in the interest of making a method for fine alignment of Flash X-ray Systems at the lab. It contains python code for interacting with LTT and running optimization loops using LTT simulations or ray tracing with RaySpace. It Includes classes for creating phantom objects and modular geometry objects in the simulations. It allows one to generate a random phantom that has been optimized to stay with a certain cubic volume and maximize the minimum distance between any two ball phantom centers in all projections. It was primarily made to work on ball phantoms which were simulated as Teflon spheres. It allows the alignment from some nominal position to some displaced position to simulate recovery of a real geometry from the nominal geometry of the system. Fine alignment can be done with the projections in LTT while a rough alignment is faster using rayspace. If rayspace works well for the use case it should be preferred since it is considerably faster and less resource intensive in general. Some Notes about using this code is that one will have to edit the imports for the files to get to the correct LTT path, LTT GUI path and to the CTT path when importing. This was made by using anaconda with python 3 on windows 10. The LTT code was stored in a anaconda environment which seemed to help the python find the LTT although it shouldn’t be necessary if you append the path in your code using sys.path.append(r'add the path you want here’). The sys.path.append method is a quick way to give your python code access to a given folder when running it (such as LTT or CTT). Note that since the code was originally made with paths for a specific machine that a new user will have to edit those paths to make it work in all the files that use the old paths. This is somewhat tedious but will be required to run the code on a new machine. The methodology used to run and make these notebooks starts with opening a command prompt as administrator in windows 10. After this one would activate the anaconda environment in the appropriate directory using “conda activate myenv” in the command prompt. After this open a jupyter-notebook using the keyword “jupyter-notebook". After that a notebook should open in a browser. Note that some libraries used may not come with anaconda so those may have to be installed. There shouldn’t be much though since the main things used are scipy, numpy, matplotlib, and LTT. LTTQuicksetup also requires some paths that will be specific to the computer so that should be changed as well.

42 ENGINEERING↗

Determining Unabated Airborne Radionuclide Emissions Monitoring Requirements Using Inventory-Based Methods

Compliance with the airborne radionuclide emission monitoring requirements in the National Emission Standards for Hazardous Air Pollutants (NESHAP; 40 CFR Part 61, Subpart H) and State requirements in Washington Administrative Code 246–247 and 173-480 were evaluated for Pacific Northwest National Laboratory (PNNL) operations. Additional guidance may be found in the U.S. Department of Energy Handbook, Environmental Radiological Effluent Monitoring and Environmental Surveillance. To meet regulatory requirements, reviews of planned or proposed projects and activities provide the basis for implementing necessary monitoring adjustments or for implementing changes to projects and activities in a timely manner. Potential unabated off-site doses were evaluated for emission locations managed by PNNL and licensed to the Department of Energy. These locations were at facilities in Richland, Washington (i.e., the Hanford Site and PNNL-Richland Campus) and in Sequim, Washington, (PNNL-Sequim Campus, which formerly was known as the Marine Sciences Laboratory). This report describes the inventory-based methods and provides the results for the NESHAP assessment performed in January 2021 for calendar year ending 2020.

40 CFR 61 Subpart H↗

Technical Letter Report - Preliminary Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion

The U.S. Nuclear Regulatory Commission (NRC) has a multi-year program at the Pacific Northwest National Laboratory (PNNL) to provide engineering studies and assessments of issues related to the use of nondestructive evaluation (NDE) methods for the reliable inspection of nuclear power plant components. As part of this program, there is a subtask 2D that was set up to address an assessment of issues related to the NDE of high density polyethylene (HDPE) butt fusion joints. This work is being driven by the nuclear industry wanting to employ HDPE materials in nuclear power plant systems. This being a new material for use in nuclear applications, there are a number of issues related to its use and potential problems that may evolve. The industry is pursuing ASME Code Case N-755 entitled “Use of Polyethylene (PE) Plastic Pipe for Section III, Division 1, Construction and Section XI Repair/Replacement Activities” that contains the requirements for nuclear power plant applications of HDPE. This Code Case requires that inspections be performed after the fusion joint is made by visually examining the bead that is formed and conducting a pressure test of the joint. These tests are only effective in general if gross through-wall flaws exist in the fusion joint. The NRC wants to know whether a volumetric inspection can be conducted on the fusion joint that will reliably detect lack-of-fusion conditions that may be produced during joint fusing. The NRC has requested that the work that PNNL is conducting be provided to assist them in resolving this inspection issue of whether effective volumetric NDE can be conducted to detect lack of fusion (LOF) in the butt HDPE joints. PNNL had 24 HDPE pipe specimens manufactured of 3408 material to contain LOF conditions that could be used to assess the effectiveness of NDE in detecting the LOF. Basic ultrasonic material properties were measured and used to guide the use of phased arrays and time-of-flight diffraction (TOFD) work that was conducted. Millimeter (mm) waves were also used to inspect these assemblies. Fluor and NDE Innovations, Inc. conducted TOFD inspections using their commercially available equipment on all 24 specimens. These NDE inspection results were reviewed and several of the specimens were selected for destructive evaluation using a microtome to slice small blocks of blank and fusion joint material. This interim report provides a status/summary of the work that has been conducted to date. In the areas selected for destructive testing where there were strong acoustic responses, LOF was verified. In areas where there were no NDE responses, no LOF was found. It needs to be noted that only a small amount of material has been destructively characterized at this point and further work is planned to determine if these trends hold up. Some of the material from three of the assemblies was sent off for mechanical testing but the results were not available to be included in this status report. The initial work shows that at least some of the LOF is providing NDE responses that have been verified through destructive testing. Thus, there is promise that a volumetric examination can be conducted on HDPE butt fusion joints. The future work will lead to quantifying what various NDE methods can detect, what they miss, and what they incorrectly characterize as defective.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DEVELOPMENT AND TESTING OF FAULT-DIAGNOSIS ALGORITHMS FOR REACTOR PLANT SYSTEMS

Argonne National Laboratory is further developing fault diagnosis algorithms for use by the operator of a nuclear plant to aid in improved monitoring of overall plant condition and performance. The objective is better management of plant upsets through more timely, informed decisions on control actions with the ultimate goal of improved plant safety, production, and cost management. Integration of these algorithms with visual aids for operators is taking place through a collaboration under the concept of an operator advisory system. This is a software entity whose purpose is to manage and distill the enormous amount of information an operator must process to understand the plant state, particularly in off-normal situations, and how the state trajectory will unfold in time. The fault diagnosis algorithms were exhaustively tested using computer simulations of twenty different faults introduced into the chemical and volume control system (CVCS) of a pressurized water reactor (PWR). The algorithms are unique in that each new application to a facility requires providing only the piping and instrumentation diagram (PID) and no other plant-specific information; a subject-matter expert is not needed to install and maintain each instance of an application. The testing approach followed accepted procedures for verifying and validating software. It was shown that the code satisfies its functional requirement which is to accept sensor information, identify process variable trends based on this sensor information, and then to return an accurate diagnosis based on chains of rules related to these trends. The validation and verification exercise made use of GPASS, a one-dimensional systems code, for simulating CVCS operation. Plant components were failed and the code generated the resulting plant response. Parametric studies with respect to the severity of the fault, the richness of the plant sensor set, and the accuracy of sensors were performed as part of the validation exercise. The background and overview of the software will be presented to give an overview of the approach. Following, the verification and validation effort using the GPASS code for simulation of plant transients including a sensitivity study on important parameters will be presented

Fault Diagnosis Algorithm↗

Vacuum Systems Consensus Guideline for Department of Energy Accelerator Laboratories

Vacuum vessels, including evacuated chambers and insulated jacketed dewars, can pose a potential hazard to equipment and personnel from collapse, rupture due to back-fill pressurization, or implosion due to vacuum window failure. It is therefore important to design and operate vacuum systems in accordance with applicable and sound engineering principles. 10 CFR 851 defines requirements for pressure systems that also apply to vacuum vessels subject to back-fill pressurization. Such vacuum vessels are potentially subject to the requirements of the American Society of Mechanical Engineers (ASME) Pressure Vessel Code Section VIII (hereafter referred to as the 'Code'). However, the scope of the Code excludes vessels with internal or external operating pressure that do not exceed 15 pounds per square inch gauge (psig). Therefore, the requirements of the Code do not apply to vacuum systems provided that adequate pressure relief assures that the maximum internal pressure within the vacuum vessel is limited to less than 15 psig from all credible pressure sources, including failure scenarios. Vacuum vessels that cannot be protected from pressurization exceeding 15 psig are subject to the requirements of the Code. 10 CFR 851, Appendix A, Part 4, Pressure Safety, Section C addresses vacuum system requirements for such cases as follows: (c) When national consensus codes are not applicable (because of pressure range, vessel geometry, use of special materials, etc.), contractors must implement measures to provide equivalent protection and ensure a level of safety greater than or equal to the level of protection afforded by the ASME or applicable state or local code. Measures must include the following: (1) Design drawings, sketches, and calculations must be reviewed and approved by a qualified independent design professional (i.e., professional engineer). Documented organizational peer review is acceptable. (2) Qualified personnel must be used to perform examinations and inspections of materials, in-process fabrications, non-destructive tests, and acceptance test. (3) Documentation, traceability, and accountability must be maintained for each unique pressure vessel or system, including descriptions of design, pressure conditions, testing, inspection, operation, repair, and maintenance. The purpose of this guideline is to establish a set of expectations and recommendations which will satisfy the requirements for vacuum vessels in general and particularly when an equivalent level of safety as required by 10 CFR 851 must be provided. It should be noted that these guidelines are not binding on DOE Accelerator Laboratories and that other approaches may be equally acceptable in addressing the Part 851 requirements.

43 PARTICLE ACCELERATORS↗

Preliminary structural assessment of VHTR graphite components according to ASME code - 18532

In this study, a preliminary structural assessment on a graphite component of a VHTR was done in accordance with the semi-probabilistic assessment procedures of the latest 2015 edition of the ASME Boiler and Pressure Vessel Code, Section III, Div. 5, Subpart HHA-Graphite Materials. Establishment of the Weibull distribution for the tensile strength is essential to set up the stress limits based on the probability of failure of the graphite materials. All parameters required in the ASME code were identified and evaluated for a nuclear graphite material, IG-110. The assessment of design level was done on one of fuel elements in a Korean VHTR design by two methodologies in the ASME code: (1) Simplified assessment and (2) Full assessment. The structural integrity of the fuel element was assured by both assessment methods. Also, the effect of the number of integration volume groups on the probability of failure in the full assessment was investigated and a recommendation for the conservative results was suggested. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ASME AG-1 Section FC Qualified HEPA Filters; a Particle Loading Comparison - 13435

High Efficiency Particulate Air (HEPA) Filters used to protect personnel, the public and the environment from airborne radioactive materials are designed, manufactured and qualified in accordance with ASME AG-1 Code section FC (HEPA Filters) [1]. The qualification process requires that filters manufactured in accordance with this ASME AG-1 code section must meet several performance requirements. These requirements include performance specifications for resistance to airflow, aerosol penetration, resistance to rough handling, resistance to pressure (includes high humidity and water droplet exposure), resistance to heated air, spot flame resistance and a visual/dimensional inspection. None of these requirements evaluate the particle loading capacity of a HEPA filter design. Concerns, over the particle loading capacity, of the different designs included within the ASME AG-1 section FC code[1], have been voiced in the recent past. Additionally, the ability of a filter to maintain its integrity, if subjected to severe operating conditions such as elevated relative humidity, fog conditions or elevated temperature, after loading in use over long service intervals is also a major concern. Although currently qualified HEPA filter media are likely to have similar loading characteristics when evaluated independently, filter pleat geometry can have a significant impact on the in-situ particle loading capacity of filter packs. Aerosol particle characteristics, such as size and composition, may also have a significant impact on filter loading capacity. Test results comparing filter loading capacities for three different aerosol particles and three different filter pack configurations are reviewed. The information presented represents an empirical performance comparison among the filter designs tested. The results may serve as a basis for further discussion toward the possible development of a particle loading test to be included in the qualification requirements of ASME AG-1 Code sections FC and FK[1]. (authors)

42 ENGINEERING↗

Cost-Effectiveness Analysis of the 2009 and 2012 IECC Residential Provisions – Technical Support Document

This analysis was conducted by Pacific Northwest National Laboratory (PNNL) in support of the U.S. Department of Energy’s (DOE) Building Energy Codes Program (BECP). DOE supports the development and adoption of efficient residential and commercial building energy codes. These codes set the minimum requirements for energy efficient building design and construction and ensure energy savings on a national level. This analysis focuses on one and two family dwellings, townhomes, and low-rise multifamily residential buildings. For these buildings, the basis of the energy codes is the International Energy Conservation Code (IECC). This report does not address commercial and high-rise residential buildings, which reference ANSI/ASHRAE/IES Standard 90.1.

Mendon, Vrushali V.↗

NFPA's Hydrogen Technologies Code Project

This article discusses the development of National Fire Protection Association 2 (NFPA), a comprehensive hydrogen safety code. It analyses the contents of this document with particular attention focused on new requirements for setting hydrogen storage systems. These new requirements use computational fluid dynamic modeling and risk assessment procedures to develop requirements that are based on both technical analyses and defined risk criteria. The intent is to develop requirements based on procedures that can be replicated based on the information provided in the code document. This code will require documentation of the modeling inputs and risk criteria and analyses in the supporting information. This article also includes a description of the codes and standards that address hydrogen technologies in general.

08 HYDROGEN↗

Uncertainty analysis for VERA problem 2 using the cell-code Condor v2.8.05

Condor is a cell-level neutronic calculation code that applies multi-group collision probabilities with heterogeneous response coupling method within generic geometry configurations. Under the Condor's code continuous development, the incorporation of up-to-date methodologies and state-of-the-art practices in reactor analysis represents a driving force. In this work, the capabilities of Condor v2.8.05 to develop an uncertainty analysis for realistic PWR-kind fuel assemblies are studied. The Total Monte Carlo approach is applied to quantify the impact of fabrication tolerances in the code's results for reactivity and power distributions, by means of randomly sampled input values using the VERA problem 2 as basis. The VERA problem 2 proposes a series of Westinghouse 2D 17 x 17-type fuel lattices, to be calculated reflected at beginning-of-life without Xe. The configurations correspond to a modern PWR. Selected neutronic parameters from Condor runs are thus analyzed in terms of the observed spread as well as the obtained distributions for the randomly perturbed cases, showing the capability of the code to handle the required input data, as well as its ability to provide valuable insights regarding uncertainty quantification.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of SAS4A/SASSYS-1 for predicting steady-state single-phase natural circulation

The validation of system analysis codes for nuclear reactor systems is required for the development and application of these computational tools. Designed as a comprehensive system analysis code for advanced nuclear reactors, SAS4A/SASSYS-1 requires validation of its physics model for capturing single-phase natural circulation behavior. To support the validation of SAS4A/SASSYS-1, high-precision experiments are performed capturing steady-state single-phase natural circulation on a scaled facility with comprehensive instrumentation. In this work, dedicated tests are performed quantifying the critical modeling parameters, and a single-phase natural circulation benchmark dataset is obtained with well-documented uncertainty and comprehensive facility description. The validation is then performed against the dataset examining the capability of SAS4A/SASSYS-1 in simulating steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators which quantify and restrict numerical errors from discretization. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, quantifying the output uncertainty in a Monte Carlo approach. The composition of the output uncertainty is also quantified through a variance-based sensitivity analysis. With the uncertainty quantified for each individual condition, a detailed comparison between the simulation results and experimental data is performed covering the whole dataset. The results show consistent agreement for all primary parameters. The current validation activity provides a valuable benchmark dataset for the validation of system analysis codes in capturing single-phase natural circulation and demonstrates satisfactory prediction capability of SAS4A/SASSYS1 for steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗