Search NASA⌕ Search

SEARCH · Search NASA

Results for “compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Summary of 65-Series Compressor-Blade Low-Speed Cascade Data by Use of the Carpet-Plotting Technique

The carpet-plotting technique is presented in this paper as a more useful and concise method of summarizing cascade data on the NACA 65-series compressor blades given in NACA Technical Note 3916. Carpet plots included permit the selection of the blade camber and the design angle of attack required to fulfill a design vector diagram. Other carpet plots provide means for the prediction of off-design turning angles. Also presented are carpet plots of an isentropic pressure-rise coefficient as a entering Mach number.

COMPRESSORS - AXIAL-FLOW↗

Systematic two-dimensional cascade tests of NACA 65-series compressor blades at low speeds

A two-dimensional low-speed porous-wall cascade tunnel investigation has been conducted to establish the performance of the NACA 65-series compressor blade sections over the useful range of inlet angle, solidity, and section camber. Design points for optimum high-speed operation are presented. The loading limitation is determined for some conditions. Trends of section operating range with increasing section camber are determined for the four inlet angles tested.

COMPRESSORS - AXIAL-FLOW↗

Empirical mode constants for calculating frequencies of axial-flow compressor blades

The vibration characteristics of a group of axial-flow compressor blades of similar geometry were investigated. Empirical-mode constants were determined for the first three bending and torsional modes. A comparison of experimentally determined frequencies of a second group of blades with frequencies computed using these mode constants showed that the computed values were correct within 10 percent. The approximate limiting ratios of depth to chord and length to chord below which these constants could not be used to compute the natural frequencies were also found experimentally.

COMPRESSORS - STRESS AND VIBRATION↗

Performance of High-pressure-ratio Axial-flow Compressor Using Highly Cambered NACA 65-series Blower Blades at High Mach Numbers

A complete stage of an axial-flow compressor was designed and built to investigate the possibility of obtaining a high pressure ratio with an acceptable efficiency through the use of the optimum combination of high blade loading and high relative inlet Mach number. Over-all stage performance was investigated over a range of flows at equivalent tip speeds of 418 to 836 feet per second. At design speed (836 ft/sec), a peak total-pressure ration of 1.445 was obtained with an adiabatic efficiency of 0.89. For design angle of attack at the mean radius, a total-pressure ratio of 1.392 was obtained.

COMPRESSORS - AXIAL FLOW↗

Investigation of Blade-row Flow Distributions in Axial-flow-compressor Stage Consisting of Guide Vanes and Rotor-blade Row

A 30-inch tip-diameter axial-flow compressor stage was investigated with and without rotor to determine individual blade-row performance, interblade-row effects, and outer-wall boundary-layer conditions. Velocity gradients at guide-vane outlet without rotor approximated design assumptions, when the measured variation of leaving angle was considered. With rotor in operation, Mach number and rotor-blade effects changed flow distribution leaving guide vanes and invalidated design assumption of radial equilibrium. Rotor-blade performance correlated interpolated two-dimensional results within 2 degrees, although tip stall was indicated in experimental and not two-dimensional results. Boundary-displacement thickness was less than 1.0 and 1.5 percent of passage height after guide vanes and after rotor, respectively, but increased rapidly after rotor when tip stall occurred.

COMPRESSORS - AXIAL FLOW↗

Altitude Wind Tunnel Investigation of the Performance of Compressor, Combustor, and Turbine Components of Prototype J47D (RX1-1) Turbojet Engine

As a portion of an over-all performance investigation of the prototype J47D (RX-1) turbojet engine, performance of the compressor, combustor, and turbine components has been determined in the Lewis altitude wind tunnel over a range of altitude from 5000 to 55,000 feet and at flight Mach numbers from 0.19 to 0.92. Investigations were conducted with the engine operating on an electronic control schedule and slow with a two-lever control system by which fuel flow and exhaust-nozzle area could be controlled separately. Two combustor configurations were investigated.

ENGINES, TURBO-JET↗

Performance of single-stage compressor designed on basis of constant total enthalpy with symmetrical velocity diagram at all radii and velocity ratio of 0.7 at rotor hub / Jack R. Burtt and Robert J. Jackson

A typical inlet axial-flow compressor inlet stage, which was designed on the basis of constant total enthalpy with symmetrical velocity diagram at all radii, was investigated. At a tip speed of 1126 feet per second, a peak pressure ratio of 1.28 was obtained at an efficiency of 0.76. At a tip speed, the highest practical flow was 28 pounds per second per square foot frontal area with an efficiency of 0.78. Data for a rotor relative inlet Mach number range of from 0.5 to 0.875 indicates that the critical value for any stage radial element is approximately 0.80 for the stage investigated.

FANS↗

A comparison of typical national gas turbine establishment and NACA axial-flow compressor blade sections in cascade at low speed

Comparative cascade tests of the NGTE (National Gas Turbine Establishment of Great Britain) 10C4/30C50 and NACA 65-(12)10 axial flow compressor blade sections were conducted in a 5-inch low-speed cascade tunnel at the Langley Laboratory at air-inlet angles of 30 degrees, 45 degrees, and 60 degrees and a solidity of 1.0 by using the porous-wall technique. These NACA data for the NGTE 10C4/30C50 section were also compared with data from NGTE design charts for the same section. British and NACA incompressible cascade force-analysis equations are included.

CASCADES, EXPERIMENT↗

Method of Estimating the Incompressible-flow Pressure Distribution of Compressor Blade Sections at Design Angle of Attack

A method was devised for estimating the incompressible-flow pressure distribution over compressor blade sections at design angle of attack. The theoretical incremental velocities due to camber and thickness of the section as an isolated airfoil are assumed proportional to the average passage velocity and are modified by empirically determined interference factors. Comparisons were made between estimated and test pressure distributions of NACA 65-series sections for typical conditions. Good agreement was obtained.

COMPRESSOR FLOW THEORY AND EXPERIMENT↗

Calculations of the Performance of a Compression-Ignition Engine-Compressor Turbine Combination I : Performance of a Highly Supercharged Compression-Ignition Engine

Small high-speed single-cylinder compression-ignition engines were tested to determine their performance characteristics under high supercharging. Calculations were made on the energy available in the exhaust gas of the compression-ignition engines. The maximum power at any given maximum cylinder pressure was obtained when the compression pressure was equal to the maximum cylinder pressure. Constant-pressure combustion was found possible at an engine speed of 2200 rpm. Exhaust pressures and temperatures were determined from an analysis of indicator cards. The analysis showed that, at rich mixtures with the exhaust back pressure equal to the inlet-air pressure, there is excess energy available for driving a turbine over that required for supercharging. The presence of this excess energy indicates that a highly supercharged compression-ignition engine might be desirable as a compressor and combustion chamber for a turbine.

EXHAUST GASES-TEMPERATURE↗

Aerodynamic Performance of a Compact, High Work-Factor Centrifugal Compressor at the Stage and Subcomponent Level

The measured aerodynamic performance of a compact, high work-factor, single-stage centrifugal compressor, comprising an impeller, diffuser, 90º-bend, and exit guide vane is reported. Performance levels are based on steady-state total-pressure and total-temperature rake and angularity-probe data acquired at key machine rating planes during recent testing at NASA Glenn Research Center. Aerodynamic performance at the stage level is reported for operation between 70 to 105% of design corrected speed, with subcomponent (impeller, diffuser, and exit-guide-vane) flow field measurements presented and discussed at the 100% design-speed condition. Individual component losses from measurements are compared with pre-test CFD predictions on a limited basis.

Compressor↗

Aerodynamic Performance of a Compact, High Work-Factor Centrifugal Compressor at the Stage and Subcomponent Level

The measured aerodynamic performance of a compact, high work factor, single-stage centrifugal compressor, comprising an impeller, diffuser, 90-bend, and exit guide vane (EGV), is reported. Performance levels are based on steady-state total-pressure and total-temperature rake and angularity-probe data acquired at key machine rating planes during recent testing at NASA Glenn Research Center. Aerodynamic performance at the stage level are reported for operation between 70 to 105 of design corrected speed, with subcomponent (impeller, diffuser, and exitguide-vane) detailed flow field measurements presented and discussed at the 100 design-speed condition. Individual component losses from measurements are compared with pre-test predictions on a limited basis.

Centrifugal↗

Aerodynamic Performance of a Compact, High Work-Factor Centrifugal Compressor at the Stage and Subcomponent Level

The measured aerodynamic performance of a compact, high work-factor, single-stage centrifugal compressor, comprising an impeller, diffuser, 90deg-bend, and exit guide vane is reported. Performance levels are based on steady-state total-pressure and total-temperature rake and angularity-probe data acquired at key machine rating planes during recent testing at NASA Glenn Research Center. Aerodynamic performance at the stage level is reported for operation between 70 to 105 percent of design corrected speed, with subcomponent (impeller, diffuser, and exit-guide-vane) flow field measurements presented and discussed at the 100 percent design-speed condition. Individual component losses from measurements are compared with pre-test CFD predictions on a limited basis.

Compressor↗

Converter Compressor Building, SWMU 089, Hot Spot Areas 1, 2, and 5 Operations, Maintenance, and Monitoring Report, Kennedy Space Center, Florida

This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from operation of the air sparging (AS) interim measure (IM) for Hot Spot (HS) Areas 1, 2, and 5 at the Converter Compressor Building (CCB) located at Kennedy Space Center (KSC), Florida. The objective of the IM at CCB HS Areas 1, 2, and 5 is to decrease concentrations of volatile organic compounds (VOCs) in groundwater in the treatment zones via AS to levels that will enable a transition to a monitored natural attenuation (MNA) phase. This OMMR presents system operations and maintenance (O&M) information and performance monitoring results since full-scale O&M began in June 2014 (2 months after initial system startup in April 2014), including quarterly performance monitoring events in July and October 2014 and January and May 2015. Based on the results to date, the AS system is operating as designed and is meeting the performance criteria and IM objective. The performance monitoring network is adequately constructed for assessment of IM performance at CCB HS Areas 1, 2, and 5. At the March 2014 KSC Remediation Team (KSCRT) Meeting, team consensus was reached for the design prepared for expansion of the system to treat the HS 4 area, and at the November 2014 KSCRT Meeting, team consensus was reached that HS 3 was adequately delineated horizontally and vertically and for selection of AS for the remedial approach for HS 3. At the July 2015 KSCRT meeting, team consensus was reached to continue IM operations in all zones until HSs 3 and 4 is operational, once HS 3 and 4 zones are operational discontinue operations in HS 1, 2, and 5 zones where concentrations are less than GCTLs to observe whether rebounding conditions occur. Team consensus was also reached to continue quarterly performance monitoring to determine whether operational zones achieve GCTLs and to continue annual IGWM of CCB-MW0012, CCBMW0013, and CCB-MW0056, located south of the treatment area. The next performance monitoring event is scheduled for July 2015.

Converter Compressor Building↗

Progress of High Efficiency Centrifugal Compressor Simulations Using TURBO

Three-dimensional, time-accurate, and phase-lagged computational fluid dynamics (CFD) simulations of the High Efficiency Centrifugal Compressor (HECC) stage were generated using the TURBO solver. Changes to the TURBO Parallel Version 4 source code were made in order to properly model the no-slip boundary condition along the spinning hub region for centrifugal impellers. A startup procedure was developed to generate a converged flow field in TURBO. This procedure initialized computations on a coarsened mesh generated by the Turbomachinery Gridding System (TGS) and relied on a method of systematically increasing wheel speed and backpressure. Baseline design-speed TURBO results generally overpredicted total pressure ratio, adiabatic efficiency, and the choking flow rate of the HECC stage as compared with the design-intent CFD results of Code Leo. Including diffuser fillet geometry in the TURBO computation resulted in a 0.6 percent reduction in the choking flow rate and led to a better match with design-intent CFD. Diffuser fillets reduced annulus cross-sectional area but also reduced corner separation, and thus blockage, in the diffuser passage. It was found that the TURBO computations are somewhat insensitive to inlet total pressure changing from the TURBO default inlet pressure of 14.7 pounds per square inch (101.35 kilopascals) down to 11.0 pounds per square inch (75.83 kilopascals), the inlet pressure of the component test. Off-design tip clearance was modeled in TURBO in two computations: one in which the blade tip geometry was trimmed by 12 mils (0.3048 millimeters), and another in which the hub flow path was moved to reflect a 12-mil axial shift in the impeller hub, creating a step at the hub. The one-dimensional results of these two computations indicate non-negligible differences between the two modeling approaches.

turbomachinery↗