Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ACTIVE

The Automated Control Testbed for Integration, Verification, and Emulation (ACTIVE) framework is a software platform designed to support the optimized operation and management of a wide range of building types. It enables the development, testing, and validation of diverse control strategies, including AI-based, rule-based, and model-based approaches. The platform facilitates a seamless transition from simulation-based evaluation of control strategies to real-world field validation and deployment. ACTIVE supports the full building management lifecycle, encompassing data acquisition and management, system monitoring, optimized control, adaptive learning services, device dispatch and coordination, as well as advanced analytics and visualization. Together, these capabilities provide an integrated environment for improving building performance, operational efficiency, reducing energy cost, and reliability.

Smith, Robert [Oak Ridge National Laboratory (ORNL↗

Impact of Cyber Attacks on High Voltage DC Transmission Damping Control

Electric grids have evolved to being a huge cyberphysical system (CPS) that combines intelligent electronic devices (IEDs), computing resources, communication networks and electricity infrastructures. The wide attack surface and increasing dependence on communication make power systems vulnerable to cyber attacks. This paper studies the impact of cyber attacks on high voltage DC (HVDC) transmission oscillation damping control. Three kinds of cyber attack models are considered: timing attack , replay attack, and false data injection attack. The attacks are applied to the HVDC damping controller, which requires widearea measurements and long-distance communication. A modified IEEE New England 39-Bus AC-HVDC system is used as the test system. Simulation results have shown that all three kinds of attacks are capable of driving the AC-HVDC system into swing or unstable conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Autonomous Control of Microreactors Using Multi-Agent Reinforcement Learning

In order for microreactors to be economically competitive, operation costs will need to be minimized through some degree of autonomous control. Previous work has demonstrated the effectiveness of reinforcement learning (RL) for load-following control in a drum-controlled microreactor. This study extends that work by exploring the potential of RL to independently control each of the reactor’s drums. We compare a single-agent RL approach with a multi-agent RL (MARL) framework, testing them for generalization across different load-following power profiles and control timescales, and for robustness in cases of randomly disabled control drums. Since the point kinetics simulation environment used in this study cannot resolve spatial effects, we assume that in the absence of spatially localized disturbances, optimal drum movements should be symmetrical. We demonstrate that single-agent RL is able to achieve accurate performance only when symmetric actions are ignored; otherwise, it fails to train a useful controller. Meanwhile, the MARL framework performs symmetric actions by design and trains a robust, accurate agent, as evidenced by mean absolute errors in power matching of 0.41% for the training power profile, 0.68% for a profile with half the drums disabled, and 0.21% for a profile on a realistic load-following time horizon.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Studies on the Vitrification Potential of High Risk Spent Nuclear Fuels

This research explored vitrification of U-Zr nuclear fuel that exhibits an explosion hazard when processed by common nitric acid dissolution. Glass frits were chosen based on properties that had been previously measured as well as being demonstrated successfully in production at the Defense Waste Process Facility (DWPF). Zirconium and Aluminum metal powders were chosen to represent the spent fuels after literature demonstrated that the potential phase that causes the issue for explosive reaction in the effluent stream is tied to the Zirconium-III phase field. DSC measurements were carried out on various simulants and waste forms to better understand thermal behavior of these materials. Zirconium (Zr) was tested with both nitric acid and the new effluent flowsheet that is under development by the SRNL Chemical Process Control (CPC) group. The nitric acid test did show the expected exothermic behavior as well as how the behavior is affected by particle size of the powders used. In contrast, the effluent samples did not show an exothermic peak. However, the concentration of metal in the samples was orders of magnitude lower than in the nitric acid testing and further testing of the effect of concentration on the exothermicity that could be measured confirmed a dampened signal. Tests were run that included frit, both DWPF Frit 510 and Iron Phosphate frit, exhibiting complex curves that included multiple endothermic and exothermic peaks during heating and cooling. The final crucible samples appear similarly to the bulk glasses pointing to these peaks being a part of the dissolution of the simulant into the base glasses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗

Shape-constrained Input Estimation for Efficient Multi-shaker Vibration Testing

Multi-shaker vibration testing is gaining interest from structural dynamics test engineers as it can provide a much more accurate match to complicated field vibration responses than traditional single-axis shaker tests. However, the force capabilities of the small modal shakers typically used in multi-shaker vibration tests has limited the achievable response levels. To date, most multi-shaker vibration tests have been performed using a variety of standard, commercially-available control systems. While these control systems are adequate for a wide range of multiple-input/multiple-output tests, their control algorithms have not been tailored for the specific problem of multi-shaker vibration tests: efficiently coordinating the various shakers to work together to achieve a desired response. Here, a new input estimation algorithm is developed and demonstrated using simulations and actual test data. This algorithm, dubbed shape-constrained input estimation, is shown to effectively coordinate multiple shakers using a set of constraint vectors based on the deflection shapes of the test structure. This is accomplished by using the singular vector shapes of the system frequency response matrix, which allows the constraint vectors to automatically change as a function of frequency. Simulation and test results indicate a significant reduction in the input forces required to achieve a desired response. Finally, the results indicate that shape-constrained input estimation is an effective method to achieve higher response levels from limited shaker forces which will enable higher level multi-shaker vibration tests to be performed.

42 ENGINEERING↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Atmospheric-river-induced precipitation in California as simulated by the regionally refined Simple Convective Resolving E3SM Atmosphere Model (SCREAM) Version 0

Abstract. Using the regionally refined mesh (RRM) configuration of the US Department of Energy's Simple Cloud-Resolving Energy Exascale Earth System Model (E3SM) Atmosphere Model (SCREAM), we simulate and evaluate four meteorologically distinct atmospheric river events over California. We test five different RRM configurations, each differing in terms of the areal extent of the refined mesh and the resolution (ranging from 800 m to 3.25 km). We find that SCREAM RRM generally has a good representation of the AR-generated precipitation in CA, even for the control simulation which has a very small 3 km refined patch, and is able to capture the fine-scale regional distributions that are controlled largely by the fine-scale topography of the state. It is found that SCREAM generally has a wet bias over topography, most prominently over the Sierra Nevada mountain range, with a corresponding dry bias on the lee side. We find that refining the resolution beyond 3 km (specifically 1.6 km and 800 m) has virtually no benefit towards reducing systematic precipitation biases but that improvements can be found when increasing the areal extent of the upstream refined mesh. However, these improvements are relatively modest and only realized if the size of the refined mesh is expanded to the scale where employing RRM no longer achieves the substantial cost benefit it was intended for.

54 ENVIRONMENTAL SCIENCES↗

Developing a PSCAD Model of the Reduced 240-Bus WECC Test System: Preprint

Fast-acting controls of inverter-based resources (IBR) introduce unprecedented dynamics to bulk power systems and island power grids, especially the high-frequency dynamics ranging from $>5$ Hz to hundreds of Hz. These oscillatory stability problems cannot be captured by the phasor domain simulations, e.g., in PSS/E, Powerworld and TSAT, due to insufficient modeling. Instead, they should be studied by electromagnetic transient (EMT) simulations by using proper EMT dynamic models. This paper develops and validates the PSCAD model of the reduced 240-bus Western Electricity Coordinating Council (WECC) test system. The PSCAD model will be released to the public, which can be used by both academia and power industry practitioners for studying the fast dynamic problems without any Critical Energy/Electric Infrastructure Information (CEII).

240-bus WECC test system↗

A Test Bed for Evaluating Frequency Estimation Algorithms in Synthetic Inertia Control: User Manual

As penetration of converter interfaced generators (CIGs) increases, the need for CIG frequency control participation increases. Traditionally, research in this area has been performed using positive sequence simulation software, which provides voltage magnitude and phase measurements, but not point-on-wave (POW) measurements. This means that the effect of frequency estimation algorithms cannot be accurately modeled, especially when the voltage waveform is distorted by faults or load connection events. This report serves as a user manual for an electromagnetic transient simulation testbed, which allows for accurate modeling of frequency estimation and control techniques.

42 ENGINEERING↗

Adaptive Stiffness Power Take-Off System for a Hydraulic Hose-Pump Point Absorber Wave Energy Converter

Two crucial challenges faced in the design of ocean wave energy converters (WECs) are maintaining high capacity factors and remaining robust in everchanging, harsh ocean environments. This study introduces a novel mechanism for achieving reactive WEC control with a soft hydraulic power take-off, thereby addressing both challenges. The device of interest involves a hydraulic pump, constructed from a fluidic flexible matrix composite (F2MC), which is cyclically stretched by driving waves and pressurizes working fluid through a turbine-generator. This class of fiber-reinforced stretch hoses is established for ocean use as robust moorings and shock absorbers. The dynamic properties of the F2MC pump depend on internal pressure, which can be controlled by a continuously variable transmission between the turbine and generator, allowing the system to be adapted for better performance over a wide range of wave conditions. This work presents a dynamic model for operation and adaptive behavior of this power take-off system, experimentally validates components of the model, and performs dynamic simulations of the system that show increases in power production and capacity factor compared to non-adaptive operation for a variety of driving wave conditions. This work develops the basis for future large-scale experimental testing and controller design of this system.

Wave energy conversion, fluidic flexible matrix co↗

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗

Development of a Distribution Optimal Power Flow Federate for Open-Source OEDI-SI Platform

Increasing numbers of distributed generators in the electric power distribution networks require developing a control strategy to optimize solutions in real time. Linearized optimal distribution flow development has seen growth and acceptance in the distribution systems literature for efficiently modeling the \glspl{opf} for distribution systems. This paper examines the implementation and integration procedure for linearized optimal distribution flow federate to \gls{oedisi} platform. Specifically, we discuss i) the usage of the \gls{oedisi} platform, ii) obtaining a tractable solution using developed \gls{opf} federate, and iii) validation of solutions and bench-marking the \gls{oedisi} platform with developed \gls{opf} federate using OpenDSS. In brief, we demonstrate how a general linearized optimal distribution flow federate can be developed and integrated with a co-simulation environment to mimic real-world examples. The efficacy of the proposed method is demonstrated using the IEEE 123-bus test system under different scenarios to obtain a tractable solution and compare its results.

Sadnan, Rabayet↗

Stability and Performance of an Undersea Kite Operating in a Turbulent Flow Field

In this paper, we examine the effects of flow disturbances resulting from turbulence on the dynamic behavior of an underwater energy-harvesting kite system that executes periodic figure-8 flight. Due to the periodic nature of the kite’s operation, we begin by assessing orbital stability using the Floquet analysis and stroboscopic intersection analysis of a Poincaré section, with the former analysis performed on a simplified “unifoil” model and the latter performed on a six-degree-of-freedom (6-DOF)/flexible tether model. With periodic stability established, a frequency-domain analysis based on a linearization about the kite’s path is used to predict the quality of flight path tracking as a function of the turbulence frequency. To validate the accuracy of these simulation-based predictions under flow disturbances, we compare the predictions of the kite’s behavior against the results of small-scale tow testing experiments performed in a controlled pool environment.

13 HYDRO ENERGY↗

NREL and SDG&E Collaboration to Support SDG&E Grid and Storage Efforts: Cooperative Research and Development Final Report, CRADA Number CRD-14-562

This project will enable effective utilization of high penetration of photovoltaics (PV) in islanded microgrids, increasing overall system efficiency, decreased fuel costs and resiliency of the overall system to help meet the SunShot goals of enhancing system integration methods to increase penetration of PV. National Renewable Energy Laboratory (NREL) will collaborate with San Diego Gas & Electric (SDG&E) to provide research and testing support to address their needs in energy storage sizing and placement, Integrated Test Facility (ITF) development, Real Time Digital Simulator (RTDS) Modeling and simulation support at ITF, Visualization and Virtual connection to Energy Systems Integration Facility (ESIF), and microgrid simulation and testing areas. Specifically in this project a real microgrid scenario with high penetration of PV (existing in SDG&E territory) is tested in the ESIF laboratory. Multiple control cases for firming PV using storage in a microgrid scenario will be investigated and tested in the laboratory setup.

14 SOLAR ENERGY↗

50 MW Segmented Ultralight Morphing Rotors for Wind Energy

A multi-institutional team designed a 50 Megawatt (MW) rated wind turbine featuring downwind aeroelastic morphing to reduce blade loads and allow an ultralight segmented rotor (mass reduction of about 25% compared to a conventional upwind rotor). The team used a control co-design approach with state-of-the art simulations including for the rotor and tower design using non-linear fluid-structure interactions and control algorithms, and the team also designed, built, and field-tested an aeroelastically-scaled downwind rotor to demonstrate this novel technology and validate the design tool fidelity. In a follow-on phase, these results were used along with an updated Levelized Cost Of Energy (LCOE) methodology to co-design a more detailed set of 25 MW rated turbine designs (including individual pitch control) based on minimum LCOE with highly flexible blades for an Atlantic Ocean offshore fixed-bottom design targeted towards market technology evaluation. A set of upwind and downwind designs at 25 MW rated scales were found to provide the best LCOE, with strong improvements over all previous offshore reference turbines (NREL 5MW, DTU 10 MW and IEA 15 MW). The optimized design would represent the world’s largest offshore turbine design, which combines several state-of-the-art structural, aerodynamic, and control technologies into a new and optimized system concept.

17 WIND ENERGY↗

Condition monitoring and false alarm reducing of sensors in NPP - 222

With more and more application of digital I and C systems in nuclear power plants (NPP), more and more sensors are also required. Large amount of sensors really can make contribution to the condition monitoring of systems and equipment in NPP, whereas the heavy use also increases the malfunction risk of sensor self. Therefore the reliability and effectiveness of sensors must be guaranteed first. Thus the condition of sensors should be monitored first in a NPP. Since the precise mathematical models of sensors in complex systems are relative difficult to establish, however quantity of operating data can be easily obtained due to the wide application of digital I and C systems, thus this article adopts principal component analysis (PCA) to carry out condition monitoring for sensors. The PCA model developed for sensors is proved to be effective with operating data acquired from a real NPP. It can detect and isolate the fault when an artificial fault is imposed to the normal data. Then the monitoring results are further processed by another control limit (second confidence limit) besides T 2 and Q statistics (first confidence limit) in PCA. The value of second confidence limit is calculated based on the probability statistics of T 2 and Q statistics. And simulation tests show that the application of the second confidence limit can greatly reduce false alarms in the PCA model and the model performance can be greatly improved with the application of false alarms reducing method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗