Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Electronic desalting for controlling the ionic environment in droplet-based biosensing platforms

The ability to control the ionic environment in saline waters and aqueous electrolytes is useful for desalination as well as electronic biosensing. We demonstrate a method of electronic desalting at micro-scale through on-chip micro electrodes. We show that, while desalting is limited in bulk solutions with unlimited availability of salts, significant desalting of ≥1 mM solutions can be achieved in sub-nanoliter volume droplets with diameters of ∼250 μm. Within these droplets, by using platinum-black microelectrodes and electrochemical surface treatments, we can enhance the electrode surface area to achieve >99% and 41% salt removal in 1 mM and 10 mM salt concentrations, respectively. Through self-consistent simulations and experimental measurements, we demonstrate that conventional double-layer theory over-predicts the desalting capacity and, hence, cannot be used to model systems that are mass limited or undergoing significant salt removal from the bulk. Our results will provide a better understanding of capacitive desalination, as well as a method for salt manipulation in high-throughput droplet-based microfluidic sensing platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biological effect of dose distortion by fiducial markers in spot-scanning proton therapy with a limited number of fields: A simulation study

Purpose: In accurate proton spot-scanning therapy, continuous target tracking by fluoroscopic x ray during irradiation is beneficial not only for respiratory moving tumors of lung and liver but also for relatively stationary tumors of prostate. Implanted gold markers have been used with great effect for positioning the target volume by a fluoroscopy, especially for the cases of liver and prostate with the targets surrounded by water-equivalent tissues. However, recent studies have revealed that gold markers can cause a significant underdose in proton therapy. This paper focuses on prostate cancer and explores the possibility that multiple-field irradiation improves the underdose effect by markers on tumor-control probability (TCP). Methods: A Monte Carlo simulation was performed to evaluate the dose distortion effect. A spherical gold marker was placed at several characteristic points in a water phantom. The markers were with two different diameters of 2 and 1.5 mm, both visible on fluoroscopy. Three beam arrangements of single-field uniform dose (SFUD) were examined: one lateral field, two opposite lateral fields, and three fields (two opposite lateral fields + anterior field). The relative biological effectiveness (RBE) was set to 1.1 and a dose of 74 Gy (RBE) was delivered to the target of a typical prostate size in 37 fractions. The ratios of TCP to that without the marker (TCP{sub r}) were compared with the parameters of the marker sizes, number of fields, and marker positions. To take into account the dependence of biological parameters in TCP model, {alpha}/{beta} values of 1.5, 3, and 10 Gy (RBE) were considered. Results: It was found that the marker of 1.5 mm diameter does not affect the TCPs with all {alpha}/{beta} values when two or more fields are used. On the other hand, if the marker diameter is 2 mm, more than two irradiation fields are required to suppress the decrease in TCP from TCP{sub r} by less than 3%. This is especially true when multiple (two or three) markers are used for alignment of a patient. Conclusions: It is recommended that 1.5-mm markers be used to avoid the reduction of TCP as well as to spare the surrounding critical organs, as long as the markers are visible on x-ray fluoroscopy. When 2-mm markers are implanted, more than two fields should be used and the markers should not be placed close to the distal edge of any of the beams.

60 APPLIED LIFE SCIENCES↗

WE-AB-202-12: Voxel-Wise Analysis of Apparent Diffusion Coefficient and Perfusion Maps in Multi-Parametric MRI of Prostate Cancer

Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients were used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with Varian Medical Systems, not related to the work presented in this abstract.

60 APPLIED LIFE SCIENCES↗

Peculiarities of Phase Transformations of Polymer Solutions in Deformable Porous Matrices

Methods of equilibrium chemical thermodynamics have been used to simulate laws of the influence of geometric factors (pore shape and volume) on the phase equilibria is stratifying polymer solutions in porous matrices. Using the example of the phase separation in a liquid polybutadiene–polystyrene system, it is established that deformation of the porous matrix determining the geometric characteristics of pores can be used to control the mutual solubilities of components and the volumes and thermodynamic stability of coexisting equilibrium phases. Significant deformations of the matrix lead to suppression of the phase separation in pores and make any solution compositions possible (up to equimolar mixtures).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method, system and computer program product for monitoring and optimizing fluid extraction from geologic strata

An arrangement which utilizes an inexpensive flap valve/flow transducer combination and a simple local supervisory control system to monitor and/or control the operation of a positive displacement pump used to extract petroleum from geologic strata. The local supervisory control system controls the operation of an electric motor which drives a reciprocating positive displacement pump so as to maximize the volume of petroleum extracted from the well per pump stroke while minimizing electricity usage and pump-off situations. By reducing the electrical demand and pump-off (i.e., "pounding" or "fluid pound") occurrences, operating and maintenance costs should be reduced sufficiently to allow petroleum recovery from marginally productive petroleum fields. The local supervisory control system includes one or more applications to at least collect flow signal data generated during operation of the positive displacement pump. No flow, low flow and flow duration are easily evaluated using the flap valve/flow transducer arrangement.

58 GEOSCIENCES↗

Particle Imaging Velocimetry Technique Development for Laboratory Measurement of Fracture Flow Inside a Pressure Vessel Using Neutron Imaging

This paper will describe recent progress made in developing neutron imaging based particle imaging velocimetry techniques for visualizing and quantifying flow structure through a high pressure flow cell with high temperature capability (up to 350 degrees C). This experimental capability has great potential for improving the understanding of flow through fractured systems in applications such as enhanced geothermal systems (EGS). For example, flow structure measurement can be used to develop and validate single phase flow models used for simulation, experimentally identify critical transition regions and their dependence on fracture features such as surface roughness, and study multiphase fluid behavior within fractured systems. The developed method involves the controlled injection of a high contrast fluid into a water flow stream to produce droplets that can be tracked using neutron radiography. A description of the experimental setup will be provided along with an overview of the algorithms used to automatically track droplets and relate them to the velocity gradient in the flow stream. Experimental results will be reported along with volume of fluids based simulation techniques used to model observed flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-Term Outcomes of Fractionated Stereotactic Radiation Therapy for Pituitary Adenomas at the BC Cancer Agency

Purpose: To assess the long-term disease control and toxicity outcomes of fractionated stereotactic radiation therapy (FSRT) in patients with pituitary adenomas treated at the BC Cancer Agency. Methods and Materials: To ensure a minimum of 5 years of clinical follow-up, this study identified a cohort of 76 patients treated consecutively with FSRT between 1998 and 2007 for pituitary adenomas: 71% (54/76) had nonfunctioning and 29% (22/76) had functioning adenomas (15 adrenocorticotrophic hormone-secreting, 5 growth hormone-secreting, and 2 prolactin-secreting). Surgery was used before FSRT in 96% (73/76) of patients. A median isocenter dose of 50.4 Gy was delivered in 28 fractions, with 100% of the planning target volume covered by the 90% isodose. Patients were followed up clinically by endocrinologists, ophthalmologists, and radiation oncologists. Serial magnetic resonance imaging was used to assess tumor response. Results: With a median follow-up time of 6.8 years (range, 0.6 - 13.1 years), the 7-year progression-free survival was 97.1% and disease-specific survival was 100%. Of the 2 patients with tumor progression, both had disease control after salvage surgery. Of the 22 patients with functioning adenomas, 50% (11/22) had complete and 9% (2/22) had partial responses after FSRT. Of the patients with normal pituitary function at baseline, 48% (14/29) experienced 1 or more hormone deficiencies after FSRT. Although 79% (60/76) of optic chiasms were at least partially within the planning target volumes, no patient experienced radiation-induced optic neuropathy. No patient experienced radionecrosis. No secondary malignancy occurred during follow-up. Conclusion: In this study of long-term follow-up of patients treated for pituitary adenomas, FSRT was safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Failure in Parameningeal Rhabdomyosarcoma Correlates With Poor Response to Induction Chemotherapy

Background: Local control remains a challenge in pediatric parameningeal rhabdomyosarcoma (PM-RMS), and survival after local failure (LF) is poor. Identifying patients with a high risk of LF is of great interest to clinicians. In this study, we examined whether tumor response to induction chemotherapy (CT) could predict LF in embryonal PM-RMS. Methods: We identified 24 patients with embryonal PM-RMS, age 2 to 18 years, with complete magnetic resonance imaging and gross residual disease after surgical resection. All patients received proton radiation therapy (RT), median dose 50.4 Gy{sub RBE} (50.4-55.8 Gy{sub RBE}). Tumor size was measured before initial CT and before RT. Results: With a median follow-up time of 4.1 years for survivors, LF was seen in 9 patients (37.5%). The median time from the initiation of CT to the start of RT was 4.8 weeks. Patients with LF had a similar initial (pre-CT) tumor volume compared with patients with local controlled (LC) (54 cm{sup 3} vs 43 cm{sup 3}, P=.9) but a greater median volume before RT (pre-RT) (40 cm{sup 3} vs 7 cm{sup 3}, P=.009) and a smaller median relative percent volume reduction (RPVR) in tumor size (0.4% vs 78%, P<.001). Older age (P=.05), larger pre-RT tumor volume (P=.03), and smaller RPVR (P=.003) were significantly associated with actuarial LF on univariate Cox analysis. Conclusions: Poor response to induction CT appears to be associated with an increased risk of LF in pediatric embryonal PM-RMS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Tank Mapping Method Improves Waste Removal Process

Waste Tank Mapping Overview • Camera inspections are performed within available tank top risers and used to create waste tank maps – Several camera inspections are performed during waste removal transfers to verify the elevation of the visible salt/sludge mounds against the known elevation of the liquid surface • Tank mappings are used to evaluate the volume and distribution of saltcake or sludge that is present within the waste tank – Allows for refined operating strategies and process safety controls • New tank mapping process creates a standardized approach for accurately defining waste distribution within a waste tank while minimizing the required camera inspection footage – First utilized during the 2023 Tank 22 Sludge Removal Campaign

Mini, Melany [Savannah River Mission Completion (S↗

Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

A feasibility study of dynamic adaptive radiotherapy for nonsmall cell lung cancer

Purpose: The final state of the tumor at the end of a radiotherapy course is dependent on the doses given in each fraction during the treatment course. This study investigates the feasibility of using dynamic adaptive radiotherapy (DART) in treating lung cancers assuming CBCT is available to observe midtreatment tumor states. DART adapts treatment plans using a dynamic programming technique to consider the expected changes of the tumor in the optimization process. Methods: DART is constructed using a stochastic control formalism framework. It minimizes the total expected number of tumor cells at the end of a treatment course, which is equivalent to maximizing tumor control probability, subject to the uncertainty inherent in the tumor response. This formulation allows for nonstationary dose distributions as well as nonstationary fractional doses as needed to achieve a series of optimal plans that are conformal to the tumor over time, i.e., spatiotemporally optimal plans. Sixteen phantom cases with various sizes and locations of tumors and organs-at-risk (OAR) were generated using in-house software. Each case was planned with DART and conventional IMRT prescribing 60 Gy in 30 fractions. The observations of the change in the tumor volume over a treatment course were simulated using a two-level cell population model. Monte Carlo simulations of the treatment course for each case were run to account for uncertainty in the tumor response. The same OAR dose constraints were applied for both methods. The frequency of replanning was varied between 1, 2, 5 (weekly), and 29 times (daily). The final average tumor dose and OAR doses have been compared to quantify the potential dosimetric benefits of DART. Results: The average tumor max, min, mean, and D95 doses using DART relative to these using conventional IMRT were 124.0%–125.2%, 102.1%–114.7%, 113.7%–123.4%, and 102.0%–115.9% (range dependent on the frequency of replanning). The average relative maximum doses for the cord and esophagus, mean doses for the heart and lungs, and D05 for the unspecified tissue resulting 84%–102.4%, 99.8%–106.9%, 66.9%–85.6%, 58.2%–78.8%, and 85.2%–94.0%, respectively. Conclusions: It is feasible to apply DART to the treatment of NSCLC using CBCT to observe the midtreatment tumor state. Potential increases in the tumor dose and reductions in the OAR dose, particularly for parallel OARs with mean or dose–volume constraints, could be achieved using DART compared to nonadaptive IMRT.

60 APPLIED LIFE SCIENCES↗

An integrated equipment for massive segmentation and packaging of control Rod Guide Tubes - 15161

Over time, some utilities have decided to undergo safety upgrades that include replacement of some ageing components like control rod guide tubes (GT's). GT's are safety related components because they control the path of the control rods into and out of the core. These components are usually stored underwater in interim storage pools to decay their radioactivity. When the interim storage facility reaches saturation, treatment and final disposal of the retired Guide Tubes needs to be performed. Based on more than 30 years of experience and lessons learned in the development of segmentation and packaging technologies for nuclear components, Westinghouse has designed, commissioned and will operate a dedicated system for cutting and packaging retired GT's from 900 MW plants, currently stored in a EDF maintenance facility located in the south of France. The first main technical challenge was the waste volume optimization. Two separate waste streams had to be considered for coping with the highly irradiated portion of the GT's (lower part) and the very low level waste sections (upper part). The segmentation plan has been designed to minimize the waste volume of the highly irradiated waste and therefore develop a process which could be adapted to the container size specified by EDF. Metallic baskets have been designed to optimize the packaging and storage density in the containers. All cutting techniques previously used by Westinghouse in similar applications were assessed and underwater mechanical cutting with a band saw was selected as the preferred method. A turning stand positions the GT in front of the band saw. When the cut is completed, the remnant GT is inserted into the next turning stand for the next cut. Each cell of the turning stand positions the GT at the pre-defined cutting height. An integrated water filtration system is used to ensure good visibility during the cutting operations and to minimize water volume and limit the final liquid effluents. The whole process of GT insertion, cutting, packaging and waste conditioning is carried out in a hot cell and controlled remotely. The operator can therefore follow the packaging plan accurately and safely by using a four axis pick and place unit, while keeping personal radiation exposure low. This innovative process allows cutting and packaging large quantities of GT's in a safe and efficient manner. The pilot project covers the segmentation of 93 GT's but it can be further used for cutting larger quantities of retired GT's resulting from the upcoming GT replacement campaigns. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Successful Implementation of Soil Segregation Technology at the Painesville FUSRAP Site - 12281

Typically the highest cost component of the radiological soils remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites is the cost to transport and dispose of the excavated soils, typically contaminated with naturally occurring isotopes of uranium, thorium and radium, at an appropriately permitted off-site disposal facility. The heterogeneous nature of the contamination encountered at these sites makes it difficult to accurately delineate the extent of contaminated soil using the limited, discrete sampling data collected during the investigation phases; and difficult to precisely excavate only the contaminated soil that is above the established cleanup limits using standard in-field scanning and guiding methodologies. This usually results in a conservative guided excavation to ensure cleanup criteria are met, with the attendant transportation and disposal costs for the larger volumes of soil excavated. To address this issue during the remediation of the Painesville FUSRAP Site, located in Painesville, Ohio, the Buffalo District of the U.S. Army Corps of Engineers, and its contractor, Safety and Ecology Corporation (SEC), employed automatic soil segregation technology provided by MACTEC (now AMEC) to reduce the potential for transportation and disposal of soils that met the cleanup limits. This waste minimization technology utilized gamma spectroscopy of conveyor-fed soils to automatically segregate the material into above and below criteria discharge piles. Use of the soil segregation system resulted in cost savings through the significant reduction of the volume of excavated soil that required off-site transportation and disposal, and the reduction of the amount of imported clean backfill required via reuse of 'below criteria' segregated soil as place back material in restoring the excavations. Measurements taken by the soil segregation system, as well as results of quality control sampling of segregated soils, confirmed that soils segregated as below criteria for reuse as site fill did meet the Record of Decision cleanup criteria for the site. Automatic soil segregation technology was successfully implemented as part of the 2010 - 2011 remediation effort at the Painesville FUSRAP Site. The Orion ScanSortSM system employed at the site demonstrated the ability to accurately determine the radioactivity concentrations in the processed soil and soil-like material and quickly segregate that material for appropriate final disposition. Data from the soil segregation system and confirmatory QC samples indicated that the segregated 'below criteria' soils met the cleanup criteria in the ROD, and was appropriate for reuse as fill in the excavations. The reduction of the total excavated soil volume requiring off-site disposal by 94% yielded significant project cost savings through reduction of transportation and disposal and backfill procurement costs. Use of automatic soil segregation technology was an efficient and cost-effective method for addressing the radiological contamination at the Painesville Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nonpolar InGaN/GaN core–shell single nanowire lasers

We report lasing from nonpolar p-i-n InGaN/GaN multi-quantum well core–shell single-nanowire lasers by optical pumping at room temperature. The nanowire lasers were fabricated using a hybrid approach consisting of a top-down two-step etch process followed by a bottom-up regrowth process, enabling precise geometrical control and high material gain and optical confinement. The modal gain spectra and the gain curves of the core–shell nanowire lasers were measured using micro-photoluminescence and analyzed using the Hakki-Paoli method. Significantly lower lasing thresholds due to high optical gain were measured compared to previously reported semipolar InGaN/GaN core–shell nanowires, despite significantly shorter cavity lengths and reduced active region volume. Mode simulations show that due to the core–shell architecture, annular-shaped modes have higher optical confinement than solid transverse modes. Furthermore, the results show the viability of this p-i-n nonpolar core–shell nanowire architecture, previously investigated for next-generation light-emitting diodes, as low-threshold, coherent UV–visible nanoscale light emitters, and open a route toward monolithic, integrable, electrically injected single-nanowire lasers operating at room temperature.

36 MATERIALS SCIENCE↗

Tunable and rapid self-assembly of block copolymers using mixed solvent vapors

Pattern generation of well-controlled block copolymers (BCPs) with a high Flory–Huggins interaction parameter (χ) is important for applications in sub-20 nm nanolithography. In this paper, we used mixed solvents of dimethylformamide (DMF) and toluene to control the morphology as well as the time to achieve the targeted morphology via self-assembly of BCPs. By precisely controlling the volume ratio of DMF and toluene, well-ordered line, honeycomb, circular hole, and lamellar nanostructures were obtained from a cylinder-forming poly(styrene-b-2-vinylpyridine) (PS-b-P2VP) BCP with high χ. Furthermore, a well-aligned 12 nm line pattern was successfully achieved in the guiding template within one minute using the mixed solvents. Finally, this practical method may also be applicable to self-assembly of other BCPs, providing more opportunities for the next-generation sub-10 nm lithography applications.

36 MATERIALS SCIENCE↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

ADVANCED OXIDATION: OXALATE DECOMPOSITION TESTING WITH OZONE

At the Savannah River Site (SRS), oxalic acid is currently considered the preferred agent for chemically cleaning the large underground Liquid Radioactive Waste Tanks. It is applied only in the final stages of emptying a tank when generally less than 5,000 kg of waste solids remain, and slurrying based removal methods are no-longer effective. The use of oxalic acid is preferred because of its combined dissolution and chelating properties, as well as the fact that corrosion to the carbon steel tank walls can be controlled. Although oxalic acid is the preferred agent, there are significant potential downstream impacts. Impacts include: (1) Degraded evaporator operation; (2) Resultant oxalate precipitates taking away critically needed operating volume; and (3) Eventual creation of significant volumes of additional feed to salt processing. As an alternative to dealing with the downstream impacts, oxalate decomposition using variations of ozone based Advanced Oxidation Process (AOP) were investigated. In general AOPs use ozone or peroxide and a catalyst to create hydroxyl radicals. Hydroxyl radicals have among the highest oxidation potentials, and are commonly used to decompose organics. Although oxalate is considered among the most difficult organic to decompose, the ability of hydroxyl radicals to decompose oxalate is considered to be well demonstrated. In addition, as AOPs are considered to be 'green' their use enables any net chemical additions to the waste to be minimized. In order to test the ability to decompose the oxalate and determine the decomposition rates, a test rig was designed, where 10 vol% ozone would be educted into a spent oxalic acid decomposition loop, with the loop maintained at 70 C and recirculated at 40L/min. Each of the spent oxalic acid streams would be created from three oxalic acid strikes of an F-area simulant (i.e., Purex = high Fe/Al concentration) and H-area simulant (i.e., H area modified Purex = high Al/Fe concentration) after nearing dissolution equilibrium, and then decomposed to {le} 100 Parts per Million (ppm) oxalate. Since AOP technology largely originated on using ultraviolet (UV) light as a primary catalyst, decomposition of the spent oxalic acid, well exposed to a medium pressure mercury vapor light was considered the benchmark. However, with multi-valent metals already contained in the feed, and maintenance of the UV light a concern; testing was conducted to evaluate the impact from removing the UV light. Using current AOP terminology, the test without the UV light would likely be considered an ozone based, dark, ferrioxalate type, decomposition process. Specifically, as part of the testing, the impacts from the following were investigated: (1) Importance of the UV light on the decomposition rates when decomposing 1 wt% spent oxalic acid; (2) Impact of increasing the oxalic acid strength from 1 to 2.5 wt% on the decomposition rates; and (3) For F-area testing, the advantage of increasing the spent oxalic acid flowrate from 40 L/min (liters/minute) to 50 L/min during decomposition of the 2.5 wt% spent oxalic acid. The results showed that removal of the UV light (from 1 wt% testing) slowed the decomposition rates in both the F & H testing. Specifically, for F-Area Strike 1, the time increased from about 6 hours to 8 hours. In H-Area, the impact was not as significant, with the time required for Strike 1 to be decomposed to less than 100 ppm increasing slightly, from 5.4 to 6.4 hours. For the spent 2.5 wt% oxalic acid decomposition tests (all) without the UV light, the F-area decompositions required approx. 10 to 13 hours, while the corresponding required H-Area decompositions times ranged from 10 to 21 hours. For the 2.5 wt% F-Area sludge, the increased availability of iron likely caused the increased decomposition rates compared to the 1 wt% oxalic acid based tests. In addition, for the F-testing, increasing the recirculation flow rates from 40 liter/minute to 50 liter/minute resulted in an increased decomposition rate, suggesting a better use of ozone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗