Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Clustering Algorithm - Part 2

We describe the clustering algorithm used by the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) for combining the lightning pulse data into events, groups, flashes, and areas. Events are single pixels that exceed the LIS/OTD background level during a single frame (2 ms). Groups are clusters of events that occur within the same frame and in adjacent pixels. Flashes are clusters of groups that occur within 330 ms and either 5.5 km (for LIS) or 16.5 km (for OTD) of each other. Areas are clusters of flashes that occur within 16.5 km of each other. Many investigators are utilizing the LIS/OTD flash data; therefore, we test how variations in the algorithms for the event group and group-flash clustering affect the flash count for a subset of the LIS data. We divided the subset into areas with low (1-3), medium (4-15), high (16-63), and very high (64+) flashes to see how changes in the clustering parameters affect the flash rates in these different sizes of areas. We found that as long as the cluster parameters are within about a factor of two of the current values, the flash counts do not change by more than about 20%. Therefore, the flash clustering algorithm used by the LIS and OTD sensors create flash rates that are relatively insensitive to reasonable variations in the clustering algorithms.

Mach, Douglas M.↗

Engineered Membrane Vesicle Production via oprF or oprI Deletion Has Distinct Phenotypic Effects in Pseudomonas putida -putative knockouts table

Table S1, putative gene knockout targets in P. putida KT2440 to enhance vesiculation; Table S2, protein sequence identity of OmpA from E. coli K12 to P. putida KT2440 genes; Table S3, strains utilized in this study and corresponding construction details; Table S4, oligonucleotides utilized in this study; Table S5, plasmids utilized in this study; Table S6, sequences for mNeonGreen, tags, and codon-optimized genes; Figure S1, particle count per gCDW for KT2440 and knockout strains corresponding to data presented in Figure 1B; Figure S2, OD600 measurements of extracted MVs from KT2440 and knockout strains; Figure S3, particle count per gCDW for WT, ΔPP_4669, and ΔPP_1502; Figure S4, particle count per gCDW for KT2440 and knockout strains corresponding to data presented in Figure 3C; Figure S5, sizes of MVs corresponding to particle counts in Figure S4; Figure S6, particle count per gCDW for KT2440 grown on 20 mM glucose alone or 20 mM glucose plus 12.5 mM p-coumarate and 12.5 mM ferulate; Figure S7 and Figure S8, principal component analysis of the cellular fractions; Figure S9, heatmap of outer membrane proteins with differential abundance; and Figure S10, mNeonGreen (mNG) fluorescence signal for the cellular fraction and the extracellular fraction

hypervesiculation↗

Global Seismic Nowcasting With Shannon Information Entropy

Abstract Seismic nowcasting uses counts of small earthquakes as proxy data to estimate the current dynamical state of an earthquake fault system . The result is an earthquake potential score that characterizes the current state of progress of a defined geographic region through its nominal earthquake “cycle.” The count of small earthquakes since the last large earthquake is the natural time that has elapsed since the last large earthquake (Varotsos et al., 2006, https://doi.org/10.1103/PhysRevE.74.021123 ). In addition to natural time, earthquake sequences can also be analyzed using Shannon information entropy (“information”), an idea that was pioneered by Shannon (1948, https://doi.org/10.1002/j.1538‐7305.1948.tb01338.x ). As a first step to add seismic information entropy into the nowcasting method, we incorporate magnitude information into the natural time counts by using event self‐information. We find in this first application of seismic information entropy that the earthquake potential score values are similar to the values using only natural time. However, other characteristics of earthquake sequences, including the interevent time intervals, or the departure of higher magnitude events from the magnitude‐frequency scaling line, may contain additional information.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance and Characterization of a Modular Superconducting Nanowire Single Photon Detector System for Space-to-Earth Optical Communications Links

Space-to-ground photon-counting optical communication links supporting high data rates over large distances require enhanced ground receiver sensitivity in order to reduce the mass and power burden on the spacecraft transmitter. Superconducting nanowire single-photon detectors (SNSPDs) have been demonstrated to offer superior performance in detection efficiency, timing resolution, and count rates over semiconductor photodetectors, and are a suitable technology for high photon efficiency links. Recently photon detectors based on superconducting nanowires have become commercially available, and we have assessed the characteristics and performance of one such commercial system as a candidate for potential utilization in ground receiver designs. The SNSPD system features independent channels which can be added modularly, and we analyze the scalability of the system to support different data rates, as well as consider coupling concepts and issues as the number of channels increases.

Superconductors↗

A = 3 ( e , e ' ) x B ≥ 1 cross-section ratios and the isospin structure of short-range correlations

We study the relation between measured high-x B , high-Q 2 , helium-3 to tritium, (e,e') inclusive-scattering cross-section ratios and the relative abundance of high-momentum neutron-proton (np) and proton-proton (pp) short-range correlated (SRC) nucleon pairs in three-body (A=3) nuclei. In this study, analysis of this data using a simple pair-counting cross-section model suggested a much smaller np/pp ratio than previously measured in heavier nuclei, questioning our understanding of A=3 nuclei and, by extension, all other nuclei. Here we examine this finding using spectral-function-based cross-section calculations, with both an ab initio A=3 spectral function and effective Generalized Contact Formalism (GCF) spectral functions using different nucleon-nucleon interaction models. The ab initio calculation agrees with the data, showing good understanding of the structure of A=3 nuclei. An 8% uncertainty on the simple pair-counting model, as implied by the difference between it and the ab initio calculation, gives a factor of 5 uncertainty in the extracted np/pp ratio. Thus we see no evidence for the claimed "unexpected structure in the high-momentum wavefunction for hydrogen-3 and helium-3."

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Architecture and data processing alternatives for the TSE computer. Volume 3: Execution of a parallel counting algorithm using array logic (Tse) devices

A parallel algorithm for counting the number of logic-l elements in a binary array or image developed during preliminary investigation of the Tse concept is described. The counting algorithm is implemented using a basic combinational structure. Modifications which improve the efficiency of the basic structure are also presented. A programmable Tse computer structure is proposed, along with a hardware control unit, Tse instruction set, and software program for execution of the counting algorithm. Finally, a comparison is made between the different structures in terms of their more important characteristics.

Metcalfe, A. G.↗

Trace-element analysis of 1000 environmental samples per year using instrumental neutron activation analysis

The technology and methods developed at the Plum Brook Reactor to analyze 1000 samples per year and report data on as many as 56 elements are described. The manpower for the complete analysis of 20 to 24 samples per week required only 3 to 3.5 hours per sample. The solutions to problems encountered in sample preparation, irradiation, and counting are discussed. The automation of data reduction is described. Typical data on various sample matrices are presented.

Sheibley, D. W.↗

Soda Pop: A Time-Series Clustering, Alarming and Disease Forecasting Application

To introduce Soda Pop, an R/Shiny application designed to be a disease agnostic time-series clustering, alarming, and forecasting tool to assist in disease surveillance “triage, analysis and reporting” workflows within the Biosurveillance Ecosystem (BSVE). In this poster, we highlight the new capabilities that are brought to the BSVE by Soda Pop with an emphasis on the impact of methodological decisions. The Biosurveillance Ecosystem (BSVE) is a biological and chemical threat surveillance system sponsored by the Defense Threat Reduction Agency (DTRA). BSVE is intended to be user-friendly, multi-agency, cooperative, modular and threat agnostic platform for biosurveillance. In BSVE, a web-based workbench presents the analyst with applications (apps) developed by various DTRA funded researchers, which are deployed on-demand in the cloud(e.g., Amazon Web Services). These apps aim to address emerging needs and refine capabilities to enable early warning of chemical and biological threats for multiple users across local, state, and federal agencies. Soda Pop is an app developed by Pacific Northwest National Laboratory (PNNL) to meet the current needs of the BSVE for early warning and detection of disease outbreaks. Aimed for use bya diverse set of analysts, the application is agnostic to data source and spatial scale enabling it to be generalizable across many diseases and locations. To achieve this, we placed a particular emphasis on clustering and alerting of disease signals within Soda Pop without strong prior assumptions on the nature of observed diseased counts. Although designed to be agnostic to the data source, Soda Pop was initially developed and tested on data summarizing Influenza-Like Illness in military hospitals from collaboration with the Armed Forces Health Surveillance Branch. Currently, the data incorporated also includes the CDC’s National Notifiable Diseases Surveillance System(NNDSS) tables and the WHO’s Influenza A/B Influenza Data(Flunet). These data sources are now present in BSVE’s Postgres data storage for direct access. Soda Pop is designed to automate time-series tasks of data summarization, exploration, clustering, alarming and forecasting. Built as an R/Shiny application, Soda Pop is founded on the powerful statistical tool R.. Where applicable, Soda Pop facilitates nonparametric seasonal decomposition of time-series; hierarchical agglomerative clustering across reporting areas and between diseases within reporting areas; and a variety of alarming techniques including Exponential Weighted Moving Average alarms and Early Aberration Detection. Soda Pop embeds these techniques within a user-interface designed to enhance an analyst’s understanding of emerging trends in their data and enables the inclusion of its graphical elements into their dossier for further tracking and reporting. The ultimate goal of this software is to facilitate the discovery of unknown disease signals along with increasing the speed of detection of unusual patterns within these signals. Soda Pop organizes common statistical disease surveillance tasks in a manner integrated with BSVE data source inputs and outputs. The app analyzes time-series disease data and supports a robust set of clustering and alarming routines that avoid strong assumptions on the nature of observed disease counts. This attribute allows for flexibility in the data source, spatial scale, and disease types making it useful to a wide range of analysts.

97 MATHEMATICS AND COMPUTING↗

A STUDY OF CHANGES IN DEFORMATION AND METABOLISM IN LEFT VENTRICLE AS A FUNCTION OF HYPERTROPHY IN SPONTANEOUS HYPERTENSIVE RATS USING MICROPET TECHNOLOGY

Problem: In the case of hypertrophy caused by pressure overload (hypertension) there is an increase in cardiac mass and modification cardiac metabolism. Aim: This study was designed to study the changes in glucose metabolism, ejection fraction, and deformation in the left ventricle with the progression of hypertrophy in spontaneous hypertensive rats (SHR). Methods: Dynamic PET data were acquired using the microPET II at UC Davis. Two rats were imaged at 10-week intervals for 18 months. Each time a dose of approximately 1- 1.5 mCi of F-18-FDG was injected into a normotensive Wistar Kyoto (WKY) rat and the same dose was injected into a SHR rat. Each rat was imaged using a gated dynamic acquisition for 80 minutes acquiring list mode data with cardiac gating of approximately 600-900 million total counts. For the analysis of glucose of metabolism, the list mode data were histogrammed into a dynamic sequence (42 frames over 80 mins). For each time frame, projection data of 1203 140x210 sinograms of 0.582 mm bins were formed by summing the last three gates before and one after the R-wave trigger to correspond to the diastolic phase of the cardiac cycle. Dynamic sequences of 128x128x83 matrices of 0.4x0.4x0.582 mm3 voxels in x, y, and z were reconstructed using an iterative MAP reconstruction which used a prior that penalized the high frequency components of the reconstruction using appropriate weighting between 26 nearest neighboring voxels. Time activity curves were generated from the dynamic reconstructed sequence for the blood and left ventricular tissue regions of interest which were fit to a 2-compartment model to obtain a least squares fit for the kinetic parameters. For the analysis of deformation, the list mode data were histogrammed into 8 gates of the cardiac cycle, each gate was the total sum of the later 60 mins of the 80 min acquisition. Images of 128x128x83 matrices for each gate were reconstructed using the same iterative MAP reconstruction used to reconstruct the dynamic sequence. The in-plane image dimensions were doubled to 256x256x83 in order to increase the resolution for the Warping analyses. These image data sets were then cropped to 128x128x83. The end-systolic image data sets were designated as the template images and the end-diastole image data sets were designated as the target images, thus providing an analysis of the diastolic relaxation and filling phases of the cardiac cycle. The template images were manually segmented to create surface definitions representing the epi- and endocardial surfaces. Finite element models of the left ventricles were created using the segmented surfaces and defining a transversely isotropic material with fiber angles varying from the epicardial surface to the endocardial surface. A Warping analyses was performed to obtain the LV strain tensor and fiber stretch distributions. Results: In one study, the average first principal Green-Lagrange strain, fiber stretch, ejection fraction, and metabolic rate of F-18-FDG was 0.22, 1.08, 80%, 0.1 for the WKY rat and 0.16, 1.06, 50%, 0.25 for the SHR rat, respectively. These same rats studied a year later presented with a metabolic rate of F-18-FDG of 0.11 and 0.25 for the WKY and SHR, respectively. A follow-up study the average strain (n=10) and ejection fraction (n=18) was 0.21, 72.7% for WKY and 0.17, 69.8% for the SHR, respectively. Conclusion: In the case of pressure overload there is an increased reliance on carbohydrate oxidation in an attempt to maintain contractile function.

Sitek, Arkadiusz↗

A new G–M counter hybrid dead-time correction model

In this paper, a new G–M counter dead-time model based on the hybrid model is proposed and studied. The new model contains the idealized paralyzable and non-paralyzable dead-time models, but also allows the non-paralyzable dead-time to vary with the true counting rate. To validate this model, the decaying source experiment with a very pure 56 Mn source was used. The calculated true counting rates obtained by fitting the experimental data to the model were compared to the data obtained by table lookup. Finally, in general, the fitting was in good agreement (within 4.8% up to 5.35 × 10 6 counts / minute ) for a G–M counter with a paralyzable dead-time component of 85.9 μs and a non-paralyzable dead-time component ranging from 438 μs to 24.3 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Improved Weighted Least Squares Algorithm for the Analysis of Strain-Gage Balance Calibration Data

An improved version of an algorithm is presented that uses a weighted least squares fit of balance calibration data for the generation of the balance load prediction equations. The weighted least squares fit assigns a weighting factor between zero and one to each calibration data point that depends on a simple count of the number of intentionally loaded balance gages. The greater the number of the loaded gages is, the smaller a data point's weighting factor becomes. This strategy has two advantages. First, single-component loads become more influential during the regression analysis of the calibration data. In addition, the negative influence of load schedule asymmetries on the regression analysis results can more effectively be controlled. The original algorithm of 2017 was improved in 2020. Now, gage output differences relative to the natural zeros are exclusively used as input for the determination of the number of intentionally loaded gages. The improved weighted least squares fit can be applied with both the Non-Iterative Method and the Iterative Method that are used for the balance load prediction in the aerospace testing community. Machine calibration data of a force balance is used to illustrate benefits of the application of the improved weighted least squares fit of balance calibration data.

strain-gage balance↗

Equipment for subcriticality monitoring by pulse method - 240

At the present time methods and means of determining, evaluating, and monitoring the effective neutron multiplication factor or the subcriticality are becoming very important for validating and monitoring nuclear safety in connection with the accumulation of a large number of spent fuel assemblies and the transition to a more tight mode of their storage arrangement in the spent-fuel pools of NPP. Pulse method is an effective subcriticality monitoring tool for subcritical reactors and spent nuclear fuel storages. This method is based on the use neutron generator, fission chambers and instrumentation for data acquisition and processing. The measurement and control equipment was designed. It allows: neutron pulses generation with specified parameters; neutron flux response monitoring by measuring the count rate at predetermined set of sequential time intervals; data transmitting to the personal computer; data processing and subcriticality calculation; self diagnostics and health monitoring; data recording, archiving and storage. The special device is proposed to check the electronic equipment. This device simulates a signal of a neutron detector counting rate after neutron generator pulses appear. The paper presents hardware structure and composition, specification and software of the control unit, which provides neutron generator operation, data acquisition and processing. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Systematic Review and Meta-Analysis of the Global Seasonality of Norovirus

Background: Noroviruses are the most common cause of acute gastroenteritis across all ages worldwide. These pathogens are generally understood to exhibit a wintertime seasonality, though a systematic assessment of seasonal patterns has not been conducted in the era of modern diagnostics. Methods: We conducted a systematic review of the Pubmed Medline database for articles published between 1997 and 2011 to identify and extract data from articles reporting on monthly counts of norovirus. We conducted a descriptive analysis to document seasonal patterns of norovirus disease, and we also constructed multivariate linear models to identify factors associated with the strength of norovirus seasonality. Results: The searched identified 293 unique articles, yielding 38 case and 29 outbreak data series. Within these data series, 52.7% of cases and 41.2% of outbreaks occurred in winter months, and 78.9% of cases and 71.0% of outbreaks occurred in cool months. Both case and outbreak studies showed an earlier peak in season-year 2002-03, but not in season-year 2006- 07, years when new genogroup II type 4 variants emerged. For outbreaks, norovirus season strength was positively associated with average rainfall in the wettest month, and inversely associated with crude birth rate in both bivariate and multivariate analyses. For cases, none of the covariates examined was associated with season strength. When case and outbreaks were combined, average rainfall in the wettest month was positively associated with season strength. Conclusions: Norovirus is a wintertime phenomenon, at least in the temperate northern hemisphere where most data are available. Our results point to possible associations of season strength with rain in the wettest month and crude birth rate.

60 APPLIED LIFE SCIENCES↗

Non-Imaging Remote Sensing Data

Spectrometric, radiometric and polarimetric remote sensing observations of wavelengths from gamma-rays to microwaves are addressed. The basic form of the data is one dimensional arrays. At the high energy end of the spectrum, data are typically presented as pulse count versus energy, and at lower energies, as intensity versus wavelength. High spectral resolution measurements (better 1% of wavelength) are particularly useful for identifying atomic, molecular, and ionic species while broader band measurements are adequate for identifying minerals and for determining total energy fluxes. Polarization data permit the study of finely divided material such as clouds and surfaces.

Source record↗

The CUORE and CUORE-0 experiments at Gran Sasso

The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A priori precision estimation for neutron triples counting

The nondestructive assay of Plutonium bearing items for criticality, safety, security, safeguards, inventory balance, process control, waste management and compliance is often undertaken using correlated neutron counting. In particular Multiplicity Shift Register analysis allows one to extract autocorrelation parameters from the pulse train which can, within the framework of a simple interpretational model, be related to the effective {sup 240}Pu spontaneous fission mass present. The effective {sup 240}Pu mass is a weighted sum of the {sup 238}Pu, {sup 240}Pu and {sup 242}Pu masses so if the relative isotopic composition of the Pu can be established from the measured {sup 240}Pu effective mass one can estimate the total Pu mass and also the masses of the individual isotopes, example the fissile species {sup 239}Pu and {sup 241}Pu. In multiplicity counting three counting rates are obtained. These are the Singles, Doubles and Triples rates. The Singles rate is just the gross, totals or trigger rate. The Doubles and Triples rates are calculated from factorial moments of the observed signal triggered neutron multiplicity distributions following spontaneous fission in the item and can be thought of as the rate of observed coincident pairs and coincident triplets on the pulse train. Coincident events come about because the spontaneous fission and induced fission chains taking place in the item result in bursts of neutrons. These remain time correlated during the detection process and so retain information, through the burst size distribution, about the Pu content. In designing and assessing the performance of a detector system to meet a given goal it is necessary to make a priori estimates of the counting precision for all three kinds of rates. This is non-trivial because the counting does not obey the familiar rules of a Poissonian counting experiment because the pulse train has time correlated events on it and the train is sampled by event triggered gates that may overlap. For Singles and Doubles simple approximate analytical empirical rules for how to estimate the variance have been developed guided by theory and refined by experiment. However, for Triples no equivalent rules have been put forward and tested until now. In this work we propose an analytical expression, the CSH relation, for the variance on the Triples count and exercise it against experimental data gathered for Pu items measured in the Los Alamos National Laboratory's Epithermal Neutron Multiplicity Counter (ENMC). Preliminary results are encouraging and reasonable agreement with observation, considered fit for scoping studies, is obtained. We have also looked at the behavior using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗