Search NASA⌕ Search

SEARCH · Search NASA

Results for “data logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Improving Ion Implanter Productivity with In-situ Cleaning

Ion source lifetime is generally a critical factor in overall implanter productivity. However, extended ion source life only provides value in a manufacturing environment if the ion beam remains stable. As an ion source ages, apertures and insulators become coated with conductive dopant residues which cause beam instabilities, resulting in implant stoppages. These stoppages create failures and/or assists which are logged in the implanter's data files. Analog Devices has recently evaluated in-situ ion source cleaning based on use of xenon difluoride chemistry. The paper will describe how the in-situ cleaning decreased logged failures/assists, resulting in increased implanter productivity.

43 PARTICLE ACCELERATORS↗

Inferring Netflow Data

Netflow data is a specific format for looking at network traffic. With this format, many security tests are easy to run. Cloud Service Providers produce logs that do not contain all of the content that Netflow data contains. There is a possibility that the fields that are in Netflow data but absent in Cloud Service Provider logs can be inferred from the fields that are present in the Cloud Service Provider logs. By inferring the missing data fields, the same test that can be run with Netflow data would be possible to run on the logs produced by Cloud Service Providers. Cloud Service Providers include Amazon Web Services and Box.com. There are multiple different types of Cloud Services, and each provider handles them differently and produces different logs. There are IaaS (meaning infrastructure as a service), Saas (meaning software as a service), and Paas (meaning platform as a service). Each provides a different use for the user.

97 MATHEMATICS AND COMPUTING↗

U.S. Department of Energy Consequence Management Under the National Response Framework

Dramatic advances in data management have been made as a result of the Paperless FRMAC initiative, sponsored by the DOE’s Office of Emergency Response (NA-42). The FRMAC (Federal Radiological Monitoring and Assessment Center) is the hub for all radiological monitoring and the production of data products that interpret those measurements in terms of protective action guidelines. As such, very large amounts of data must be quickly assimilated from numerous sources and then widely distributed as graphical interpretations as fast as possible. Paperless FRMAC is a broad initiative to move that data faster, farther and better through telemetry, automation, and networking. This discussion reviews for the first time the status of the now two-year-old Paperless FRMAC initiative. Key features of Paperless FRMAC include multipath telemetry of measurements from DOE field teams, 24/7 Internet presence, early data entry by first responders, support for distance collaborations, and data exchange with the EPA’s SCRIBE database. The heart of the enterprise is the RAMS database, which provides seamless interfacing with GIS, LIMS, and TurboFRMAC for calculations. Paperless FRMAC is presented to users via two Internet websites. The first, FRMAC Portal website, is restricted to the emergency responders for data input, analysis, and product development. The second, CMweb website, is the showroom for completed and approved products, which are made much more widely available. In fact, CMweb offers seamless, single log-in access to all data products for any IMAAC, NARAC or CMweb user.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

AmeriFlux BR-Sa3 Santarem-Km83-Logged Forest

This is the AmeriFlux version of the carbon flux data for the site BR-Sa3 Santarem-Km83-Logged Forest. Site Description - Cleared forest. Logged site is near km 83 along BR-183.

Goulden, Mike↗

WARM AND FUZZY: TEMPERATURE AND DENSITY ANALYSIS OF AN Fe XV EUV IMAGING SPECTROMETER LOOP

The Hinode EUV Imaging Spectrometer (EIS) and X-Ray Telescope (XRT) were designed in part to work together. They have the same spatial resolution and cover different but overlapping coronal temperature ranges. These properties make a combined data set ideal for multithermal analysis, where EIS provides the best information on the cooler corona (log T < 6.5) and XRT provides the best information on the hotter corona (log T > 6.5). Here, we analyze a warm non-flaring loop detected in images made in a strong EIS Fe XV emission line with a wavelength of 284.16 A and peak formation temperature of log T = 6.3. We perform differential emission measure (DEM) analysis in three pixels at different heights above the footpoint and find multithermal results with the bulk of the emission measure in the range 6.0 < log T < 6.6. Analysis with the EIS lines alone gave a DEM with huge amounts of emission measure at very high temperatures (log T >7.2); analysis with XRT data alone resulted in a DEM that was missing most of the cooler emission measure required to produce many of the EIS lines. Thus, both results were misleading and unphysical. It was only by combining the EIS and XRT data that we were able to produce a reasonable result, one without ad hoc assumptions on the shape and range of the DEM itself.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Well 16B(78)-32 Drilling Data

This drilling data for Utah FORGE well 16B(78)-32 include a well survey, core summary, mud and mud temperature logs, daily reports of the drilling process, and additional data from the Pason oil and gas company. Well 16B(78)-32 serves as the production well for reservoir creation, fluid circulation, and demonstration of heat extraction for the FORGE project. It has been drilled as a doublet approximately 300 feet parallel to and above the injection well 16A(78)-32. The proposed total depth was 10,658 feet, which was exceeded. Spudding began on April 26th, 2023. As of June 20th, 2023, the total depth measured 10,947 feet and the vertical depth measured 8,357 feet. Drilling included the trial use of insulated drill pipe (IDP) from Eavor Technologies, which was considered a success. IDP restricts counter-current heat transfer between drilling fluid inside the drill string and hotter returning fluid in the annulus, thereby ensuring the bottomhole assembly (BHA) remains submerged in cool fluid. Eavor rented 350 joints of IDP to FORGE which were run in two consecutive BHAs at the well. The results of this trial are included here.

15 GEOTHERMAL ENERGY↗

AmeriFlux FLUXNET-1F BR-Sa3 Santarem-Km83-Logged Forest

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site BR-Sa3 Santarem-Km83-Logged Forest. This is the FLUXNET version of the carbon flux data for the site BR-Sa3 Santarem-Km83-Logged Forest produced by applying the standard ONEFlux (1F) software. Site Description - Cleared forest. Logged site is near km 83 along BR-183.

Goulden, Mike [University of California - Irvine]↗

Inference with minimal Gibbs free energy in information field theory

Non-linear and non-Gaussian signal inference problems are difficult to tackle. Renormalization techniques permit us to construct good estimators for the posterior signal mean within information field theory (IFT), but the approximations and assumptions made are not very obvious. Here we introduce the simple concept of minimal Gibbs free energy to IFT, and show that previous renormalization results emerge naturally. They can be understood as being the Gaussian approximation to the full posterior probability, which has maximal cross information with it. We derive optimized estimators for three applications, to illustrate the usage of the framework: (i) reconstruction of a log-normal signal from Poissonian data with background counts and point spread function, as it is needed for gamma ray astronomy and for cosmography using photometric galaxy redshifts, (ii) inference of a Gaussian signal with unknown spectrum, and (iii) inference of a Poissonian log-normal signal with unknown spectrum, the combination of (i) and (ii). Finally we explain how Gaussian knowledge states constructed by the minimal Gibbs free energy principle at different temperatures can be combined into a more accurate surrogate of the non-Gaussian posterior.

79 ASTRONOMY AND ASTROPHYSICS↗

HSNMon: High-Speed Monitoring Software for Omni-Path

HSNMon is a robust high speed network monitoring daemon that provides insight into network availability, hardware failure, and network performance for switches and network cards. HSNMon collects counters, forwarding tables, and error information at high resolution using publicly available Omni-Path Management APIs. The collected data can be forwarded into multiple logging infrastructures including syslog and message queuing systems. HSNMon is only the infrastructure for collecting the network data. It does not include any collected data or proprietary LANL information

Holman, Brett↗

Availability and redundancy design considerations for Electron-Ion Collider cooling water systems and components

The Electron-Ion Collider (EIC) is composed of several large-scale systems, which all require highly available cooling systems based on the Conceptual Design Report. Since the overall EIC availability goal is 85%, all the subsystems will contribute. Availability is defined by the time that a component or system is functional given a required or scheduled run time. The focus of the project was to determine if redundant or extra cooling water and deionized water pumps were needed in a subsystem to increase the overall EIC availability. The largest subsystem in the ring is the 10 o’clock cooling system, so this was used for redundancy analysis. Relationships between the components were defined as parallel, series, or m-out-of-n for the cooling towers, valves, pumps and heat exchangers to perform calculations. A comparison between an original system versus a redundant one was then done using component availability from industry standards. Cost analysis was also performed to see how much the availability and cost would decrease if the redundancy application was not chosen. The Collider-Accelerator Department (CAD) also has a calculation in place for the Relativistic-Heavy Ion Collider (RHIC), so cooling water failure data was collected from their operational log and analyzed for real-life component availability. A comparison of component availability from the CAD data to the industry standards was made through the 10 o’clock cooling system layout. The results showed that the subsystems need to have over a 98% availability for an 85% goal, and that the CAD data is very close to the industry component standards. The cost differential is miniscule compared to the potential availability increase. Therefore, redundant systems can increase the overall EIC availability by a sizable amount and are worth implementing.

43 PARTICLE ACCELERATORS↗

Restoration of the Potosi Dynamic Model 2010

In topical Report DOE/FE0002068-1 [2] technical performance evaluations on the Cambrian Potosi Formation were performed through reservoir modeling. The data included formation tops from mud logs, well logs from the VW1 and the CCS1 wells, structural and stratigraphic formation from three dimensional (3D) seismic data, and field data from several waste water injection wells for Potosi Formation. Intention was for two million tons per annum (MTPA) of CO2 to be injected for 20 years. In this Task the 2010 Potosi heterogeneous model (referred to as the "Potosi Dynamic Model 2010" in this report) was re-run using a new injection scenario; 3.2 MTPA for 30 years. The extent of the Potosi Dynamic Model 2010, however, appeared too small for the new injection target. It was not sufficiently large enough to accommodate the evolution of the plume. Also, it might have overestimated the injection capacity by enhancing too much the pressure relief due to the relatively close proximity between the injector and the infinite acting boundaries. The new model, Potosi Dynamic Model 2013a, was built by extending the Potosi Dynamic Model 2010 grid to 30 miles x 30 miles (48 km by 48 km), while preserving all property modeling workflows and layering. This model was retained as the base case. Potosi Dynamic Model 2013.a gives an average CO2 injection rate of 1.4 MTPA and cumulative injection of 43 Mt in 30 years, which corresponds to 45% of the injection target. This implies that according to this preliminary model, a minimum of three (3) wells could be required to achieve the injection target. The injectivity evaluation of the Potosi formation will be revisited in topical Report 15 during which more data will be integrated in the modeling exercise. A vertical flow performance evaluation could be considered for the succeeding task to determine the appropriate tubing size, the required injection tubing head pressure (THP) and to investigate whether the corresponding well injection rate falls within the tubing erosional velocity limit. After 30 years, the plume extends 15 miles (24 km) in E-W and 14 miles (22 km) in N-S directions. After injection is completed, the plume continues to migrate laterally, mainly driven by the remaining pressure gradient. After 100 years post-injection, the plume extends 17 miles (27 km) in E-W and 15 miles (24 km) in N-S directions. The increase of reservoir pressure at the end of injection is approximately 370 psia around the injector and gradually decreases away from the well. The reservoir pressure increase is less than 30 psia beyond 14 miles (22 km) away from injector. The initial reservoir pressure is restored after approximately 20 years post-injection. This result, however, is associated with uncertainties on the boundary conditions, and a sensitivity analysis could be considered for the succeeding tasks. It is important to remember that the respective plume extent and areal pressure increase corresponds to an injection of 43 Mt CO2. Should the targeted cumulative injection of 96 Mt be achieved; a much larger plume extent and areal pressure increase could be expected. Re-evaluating the permeability modeling, vugs and heterogeneity distributions, and relative permeability input could be considered for the succeeding Potosi formation evaluations. A simulation using several injectors could also be considered to determine the required number of wells to achieve the injection target while taking into account the pressure interference.

Adushita, Yasmin↗

INSPIRE and SPIRES Log File Analysis

SPIRES, an aging high-energy physics publication data base, is in the process of being replaced by INSPIRE. In order to ease the transition from SPIRES to INSPIRE it is important to understand user behavior and the drivers for adoption. The goal of this project was to address some questions in regards to the presumed two-thirds of the users still using SPIRES. These questions are answered through analysis of the log files from both websites. A series of scripts were developed to collect and interpret the data contained in the log files. The common search patterns and usage comparisons are made between INSPIRE and SPIRES, and a method for detecting user frustration is presented. The analysis reveals a more even split than originally thought as well as the expected trend of user transition to INSPIRE.

99 GENERAL AND MISCELLANEOUS↗

Storage of sparse files using parallel log-structured file system

A sparse file is stored without holes by storing a data portion of the sparse file using a parallel log-structured file system; and generating an index entry for the data portion, the index entry comprising a logical offset, physical offset and length of the data portion. The holes can be restored to the sparse file upon a reading of the sparse file. The data portion can be stored at a logical end of the sparse file. Additional storage efficiency can optionally be achieved by (i) detecting a write pattern for a plurality of the data portions and generating a single patterned index entry for the plurality of the patterned data portions; and/or (ii) storing the patterned index entries for a plurality of the sparse files in a single directory, wherein each entry in the single directory comprises an identifier of a corresponding sparse file.

97 MATHEMATICS AND COMPUTING↗

HERO WEC V1 Upgrade - 2023 Laboratory Testing (processed data)

The following submission includes processed laboratory data from NREL's Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC), in the form of MATLAB workspaces. This dataset was created using NREL's Large Amplitude Motion Platform (LAMP) and collected between August and September 2023. Included with this submission is a test log of all the processed data "HERO WEC LAMP test run log.xlsx" so that the user can easily find the data of interest. Additionally, more detailed descriptions of the type of data and how it was processed, or calculated, can be found in the document titled "Lamp Data Description.docx". The MATLAB workspaces can be visualized using the file "LAMP_Data_Viewer_Ver2.m/mlx". The user simply needs to upload the workspace of interest and run the file "LAMP_Data_Viewer_Ver2.m/mlx". Both the .m and .mlx file format has been provided depending on the user's preference. The MATLAB workspaces have been separated into zip files corresponding to either Drivetrain, Hydraulic, or Electric configuration runs representing the respective test cases that were run. The drivetrain runs were used to characterize the drivetrain only (no pump or generator). The Hydraulic runs represent the configuration when the seawater pump is installed, and the Electric runs represents the configuration when the generator is installed. The following sub-categories of data are included for each type: - DW - Deep water sine wave profile (not run in drivetrain configuration) - Heave - Heave only sine wave profile - Heave_NoRO (hydraulic configuration only) - Heave_ACC (hydraulic configuration only) - IR - Surge and heave irregular wave profile (not run in drivetrain configuration) - RW - Heave only profile created from real world encoder data (not run in drivetrain configuration) For those interested in the raw, unprocessed, data the authors have created a separate submission, linked below. This submission includes the raw TDMS files and associated files necessary to translate the data into either python or MATLAB formats. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Reservoir Engineering for Unconventional Gas Reservoirs: What Do We Have to Consider?

The reservoir engineer involved in the development of unconventional gas reservoirs (UGRs) is required to integrate a vast amount of data from disparate sources, and to be familiar with the data collection and assessment. There has been a rapid evolution of technology used to characterize UGR reservoir and hydraulic fracture properties, and there currently are few standardized procedures to be used as guidance. Therefore, more than ever, the reservoir engineer is required to question data sources and have an intimate knowledge of evaluation procedures. We propose a workflow for the optimization of UGR field development to guide discussion of the reservoir engineer's role in the process. Critical issues related to reservoir sample and log analysis, rate-transient and production data analysis, hydraulic and reservoir modeling and economic analysis are raised. Further, we have provided illustrations of each step of the workflow using tight gas examples. Our intent is to provide some guidance for best practices. In addition to reviewing existing methods for reservoir characterization, we introduce new methods for measuring pore size distribution (small-angle neutron scattering), evaluating core-scale heterogeneity, log-core calibration, evaluating core/log data trends to assist with scale-up of core data, and modeling flow-back of reservoir fluids immediately after well stimulation. Our focus in this manuscript is on tight and shale gas reservoirs; reservoir characterization methods for coalbed methane reservoirs have recently been discussed.

01 COAL, LIGNITE, AND PEAT↗

Lignin Forcefield Source Datafiles

Three archives are provided here comprising the development of a CHARMM36-compatible lignin forcefield suitable for use in biomolecular simulations. One archive parameters.zip contains the output topology and parameter files in CHARMM format suitable for use in constructing simulation systems. The remaining two hold the logic of the parameterization featuring scripts that do the optimization including the source for the GPU-accelerated objective function evaluation and target data creation scripts.zip as well as minimal outputs needed to recreate the work datafiles.zip. Due to licensing restrictions Gaussian log files that created the target data are not provided here. Instead only binary-formatted parsed target data as well as the input decks used to create the target data are provided in datafiles.zip. Readme files for individual directories created within the directory structure are contained within scripts.zip.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sediment Properties: E-Area Completion Project

To accommodate a future need for additional waste disposal facilities at the Savannah River Site, the Solid Waste Management Division (SWMD) designated nine additional plots for development (Kasraii 2007; SRS 2010); these plots are collectively known as the E Area Completion Project (ECP). Subsurface samples were collected from ECP plots 6, 7, 8 and 9 (Figure 1) for chemical and physical property analyses to support Performance Assessment (PA) and Special Analyses (SA) modeling. This document summarizes the sampling and analysis scheme and the resultant data, and provides interpretations of the data particularly in reference to existing soil property data. Analytical data in this document include: gamma log, cone penetrometer log, grain size (sieve and hydrometer), water retention, saturated hydraulic conductivity (falling head permeameter), porosity, dry bulk density, total organic carbon, x-ray diffraction, and x-ray fluorescence data. SRNL provided technical and safety oversight for the fieldwork, which included completion of eight soil borings, four geophysical logs, and the collection of 522 feet of core and 33 Shelby tubes from ECP plots 6, 7, 8, and 9. Boart Longyear provided sonic drilling and logging services. Two soil borings were completed at each location. The first set of boreholes extended into (but did not fully penetrate) the Warley Hill Formation. These boreholes were continuously cored, then geophysically (gamma ray) logged. The recovered core was split, photographed, and described; one half of the core was archived at SRS's Core Lab facilities, and the remaining half was consumed as necessary for testing at SRS and off-site labs. Core descriptions and geophysical data were used to calculate target elevations for Shelby tube samples, which were obtained from the second set of boreholes. Shelby tubes were shipped to MACTEC Engineering and Consulting Inc. (MACTEC) in Atlanta for physical property testing. SRNL deployed their Site Characterization and Analysis Penetrometer System (SCAPS) cone penetrometer test (CPT) truck at ECP plots 6, 7, 8 and 9 to collect inferred lithology data for the vadose zone. Results from this study are used to make recommendations for future modeling efforts involving the ECP plots. The conceptual model of the ECP hydrogeology differs from the conceptual model of the current ELLWF disposal area in that for the ECP plots, the topography (ground surface) is generally lower in elevation; The Upland and top of Tobacco Road lithostratigraphic units are missing (eroded); The water table occurs lower in elevation (i.e., it occurs in lower stratigraphic units); and the Tan Clay Confining Zone (TCCZ) often occurs within the vadose zone (rather than in the saturated zone). Due to the difference in the hydrogeology between the current ELLWF location and the ECP plots, different vadose zone properties are recommended for the ECP plots versus the properties recommended by Phifer et al. (2006) for the current disposal units. Results from this study do not invalidate or conflict with the current PA's use of the Upper and Lower Vadose Zone properties as described by Phifer et al. (2006) for the current ELLWF disposal units. The following modeling recommendations are made for future modeling of the ECP plots where vadose zone properties are required: (1) If a single vadose zone property is preferred, the properties described by Phifer et al. (2006) for the Upper Vadose Zone encompass the general physical properties of the combined sands and clays in the ECP vadose zone sediments despite the differences in hydrostratigraphic units. (2) If a dual zone system is preferred, a combination of the Lower Zone properties and the Clay properties described by Phifer et al. (2006) are appropriate for modeling the physical properties of the ECP vadose zone. The Clay properties would be assigned to the Tan Clay Confining Zone (TCCZ) and any other significant clay layers, while the Lower Zone properties would be assigned for the remainder of the vadose zone. No immediate updates or changes are recommended for the saturated zone properties for modeling of the ECP plots. The hydrogeology and saturated hydraulic conductivity values resulting from the ECP work are consistent with existing data for the area. The following recommendations are provided for consideration in future work: (1) When the database is next updated, we recommend checking/refining hydrostratigraphic interpretations (picks) in addition to revising physical property data for both the vadose zone and saturated zone. (2) Results from this work suggest that separate ECP vadose zone properties may be appropriate for the various ECP plots. Consideration should be given to the fact that the plots toward the northwest (ECP plots 6, 7 and 8) all have the TCCZ within the vadose zone whereas the TCCZ occurs within the saturated zone to the east (ECP plot 9). (3) Further data may be needed at ECP plot 7.

54 ENVIRONMENTAL SCIENCES↗