Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Nitrogen Vacancy Centers in Diamond for Stress Sensing Applications: Theory and Experiments

Sensing of stress under high elevated environmental conditions with high resolution has critical importance for range of applications including earth’s subsurface scanning and geological CO2 storage monitoring. Using first principles density functional theory (DFT) approach combined with the theoretical modelling of low energy Hamiltonian, here we investigate a novel approach to detect unprecedented level of pressure by taking advantage of solid-state electron’s spin of Nitrogen vacancy (NV) centers in nanodiamond. We computationally explore the effect of strain on the defect band edges and band gaps by varying the lattice parameters of diamond supercell hosting a single NV center. A low energy Hamiltonian is developed that includes effect of stress on the energy level of ±1 spin manifold at the ground state. By quantifying the energy level shift and split, we predict the pressure sensing of up to 0.3 MPa/√Hz. We show superiority of the quantum sensing over traditional optical sensing techniques by discussing our results from DFT and theoretical modelling for the frequency shift per unit pressure. The proposed quantum stress sensing could be useful to measure earth’s subsurface vibrations. Our results open avenues for development of sensing technology with a high sensitivity and resolution under extreme pressure conditions that potentially has a wider applicability than existing pressure sensing technologies.

Paudel, Hari P.↗

NDE standards for high temperature materials

High temperature materials include monolithic ceramics for automotive gas turbine engines and also metallic/intermetallic and ceramic matrix composites for a range of aerospace applications. These are materials that can withstand extreme operating temperatures that will prevail in advanced high-efficiency gas turbine engines. High temperature engine components are very likely to consist of complex composite structures with three-dimensionality interwoven and various intermixed ceramic fibers. The thermomechanical properties of components made of these materials are actually created in-place during processing and fabrication stages. The complex nature of these new materials creates strong incentives for exact standards for unambiguous evaluations of defects and microstructural characteristics. NDE techniques and standards that will ultimately be applicable to production and quality control of high temperature materials and structures are still emerging. The needs range from flaw detection to below 100 micron levels in monolithic ceramics to global imaging of fiber architecture and matrix densification anomalies in composites. The needs are different depending on the processing stage, fabrication method, and nature of the finished product. The standards are discussed that must be developed in concert with advances in NDE technology, materials processing research, and fabrication development. High temperature materials and structures that fail to meet stringent specifications and standards are unlikely to compete successfully either technologically or in international markets.

Vary, Alex↗

Biotelemetry

Sensors 2000! is developing pill-shaped biotelemeters for measuring physiological parameters during space flight life sciences experiments using rodents aboard the ISS Gravitational Biology Facility, with the additional capability for monitoring the health of astronauts in the Human Research Facility. The first "pill transmitter" is capable of measuring pressure and temperature for up to 10 months. The NASA objective is to utilize these devices. The pill-transmitters can also be used by non-NASA users for medical applications. One application is fetal surgery. The 44pill" is small enough to be endoscopically placed into the womb through a tube used during surgeries to correct fetal defects before birth. After surgery, the pill-transmitter will continue to monitor body temperature, pressure and other vital signs in the womb, radioing results to physicians. It will help them to detect preterm-labor, a serious problem after fetal surgery. The pill is about one-third-of-an-inch across and one-and-one-third-inches long. Future pill-versions will include pH, heartrate, and ECG. A pH-pill prototype is currently being tested. Sensors 2000! has also designed and built a 2-channel biotelemetry receiver and has developed data acquisition software to display and record the measured physiological parameters. A DSP-base hand-held receiver (trisponder) is currently under development.

Mundt, C.↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

Computed Tomography For Internal Inspection Of Castings

Computed tomography used to detect internal flaws in metal castings before machining and otherwise processing them into finished parts. Saves time and money otherwise wasted on machining and other processing of castings eventually rejected because of internal defects. Knowledge of internal defects gained by use of computed tomography also provides guidance for changes in foundry techniques, procedures, and equipment to minimize defects and reduce costs.

Hanna, Timothy L.↗

High-throughput spin-bath characterization of spin defects in semiconductors

Detailed knowledge of the local environments of spin defects in semiconductors, such as nitrogenvacancy (NV) centers in diamond or divacancies in silicon carbide, is crucial for optimizing control and entanglement protocols in quantum sensing and information applications. However, at present a direct experimental characterization of individual defect environments is not scalable, as conventional spin-bath measurements are time consuming and difficult to automate. Achieving high-throughput characterization requires short experiments to probe the spin bath. However, with fewer and noisier measurements, the inverse problem of recovering spin-bath properties from measured data becomes ill posed, with multiple spin baths having a high likelihood of yielding the same data. In this work, we present a set of computational tools to resolve the ill-posed inverse problem of recovering the atomic positions and hyperfine couplings of random nuclei surrounding spin defects from sparse, noisy experimental coherence data, which can be obtained in hours. Here, we use a trans-dimensional Bayesian approach that incorporates ab initio data to yield full posterior distributions over nuclear spin environments, enabling robust recovery from limited data. We also provide practical tools and guidelines to determine the limits of detectability for hyperfine couplings under specific dynamical decoupling sequences and sampling conditions. In addition, we demonstrate how the tools developed here, in combination with ab initio simulations of spin baths, can guide the design of efficient experimental protocols for application-specific high-throughput screening. To showcase the utility of our approach, we apply it to design fast dynamical decoupling experiments to characterize the spin baths often individual NV centers in diamond. While the primary focus is on accelerating spin-bath characterization of spin defects, this Bayesian approach also lays the foundation for digital-twin studies of spin defects, where a virtual model of the spin-defect system evolves in real time with ongoing experimental measurements. Together, the set of tools we designed and applied paves the way for scalable deployment of spin defects in semiconductors for quantum sensing and information applications.

Bayesian methods↗

Low-Temperature Plasma-Based Metrology of Lithium-Ion Battery Electrode Materials (CRADA Final Report)

As part of the Cyclotron Road program, SirenOpt Inc. evaluated its low-temperature plasma-based metrology sensor prototype for measuring multiple critical properties of lithium-ion battery electrode materials in parallel and in real-time. Cost-effective, minimal-waste manufacturing of high-performance battery electrode materials will be vital for achieving society’s net-zero carbon emission goals. Because existing electrode metrology sensors cannot operate within most sections of manufacturing lines, manufacturers often complete hundreds of processing steps before they can test their products and detect problems. When manufacturers perform these offline tests, they typically only test a small portion of the manufactured products. Current electrode manufacturing thus often yields many low-quality products, or off-spec products that must be thrown away all together. For example, at least 6% of the total lithium-ion battery manufacturing cost (i.e., over $250 million/year for the average gigafactory) is devoted to processing defective electrodes that are not scrapped until performance tests are failed during late-stage quality control checks. Electrode variability also leads manufacturers to build extra cells into battery packs to reduce the risk of poor performance. For example, many electric vehicle (EV) manufacturers include up to 10% more cells than needed, which substantially increases the cost and weight of the final EV product. The SirenOpt sensor can potentially enable early detection of poorly manufactured electrodes and allow them to be removed earlier from manufacturing lines, which can save battery manufacturers (hundreds of) millions of dollars per year. The sensor can further be used to improve product quality by accelerating R&D and process optimization, improving quality control, and enabling real-time process control. Overall, a real-time, in-situ metrology strategy can create unprecedented opportunities for implementation of smart manufacturing practices and advanced quality and process control solutions to realize higher battery electrode throughput and performance.

25 ENERGY STORAGE↗

An integrated atom array-nanophotonic chip platform with background-free imaging

Arrays of neutral atoms trapped in optical tweezers have emerged as a leading platform for quantum information processing and quantum simulation due to their scalability, reconfigurable connectivity, and high-fidelity operations. Individual atoms are promising candidates for quantum networking due to their capability to emit indistinguishable photons that are entangled with their internal atomic states. Integrating atom arrays with photonic interfaces would enable distributed architectures in which nodes hosting many processing qubits could be efficiently linked together via the distribution of remote entanglement. However, many atom array techniques cease to work in close proximity to photonic interfaces, with atom detection via standard fluorescence imaging presenting a major challenge due to scattering from nearby photonic devices. Here, we demonstrate an architecture that combines atom arrays with up to 64 optical tweezers and a millimeter-scale photonic chip hosting more than 100 nanophotonic cavities. We achieve high-fidelity ( ~ 99.2%), background-free imaging in close proximity to nanofabricated cavities using a multichromatic excitation and detection scheme. The atoms can be imaged while trapped a few hundred nanometers above the dielectric surface, which we verify using Stark shift measurements of the modified trapping potential. Finally, we rearrange atoms into defect-free arrays and load them simultaneously onto the same or multiple devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Liquid crystals detect voids in fiber glass laminates

Liquid crystal solution nondestructively detects voids or poor bond lines in fiber glass laminates. A thin coating of the solution is applied by spray or brush to the test article surface, and when heated indicates the exact location of defects by differences in color.

Hollar, W. T.↗

New optical approaches to the quantitative characterization of crystal growth, segregation and defect formation

Elemental and compound semiconductors were characterized using new optical approach based on NIR microscopy in conjunction with computational image analysis and contrast enhancement. The approach made it possible to perform a quantitative microsegregation analysis of GaAs and InP. NIR dark file illumination in transmission mode makes it possible to detect submicron precipitates in semiinsulating GaAs.

Carlson, D. J.↗

High-Sensitivity NO 2 Gas Sensor: Exploiting UV-Enhanced Recovery in a Hexadecafluorinated Iron Phthalocyanine-Reduced Graphene Oxide

Monitoring ultralow nitrogen dioxide (NO 2 ) concentrations is crucial for air quality management and public health. However, the existing NO 2 gas sensors have several defects, like high cost and power consumption, and exhibit poor selectivity. This study addresses these challenges by presenting a novel hexadecafluorinated iron phthalocyanine-reduced graphene oxide (FePcF 16 -rGO) covalent hybrid sensor for NO 2 detection. This innovative approach, which overcomes the limitations of fabrication cost, energy efficiency, and gas selectivity, is a significant step forward in gas sensor technology. The sensor demonstrates exceptional sensitivity toward ultralow NO 2 concentrations (15.14% response for 100 ppb) with a rapid 60 s UV light-induced recovery. Additionally, the sensor exhibits high selectivity for NO 2 , achieving a limit of detection (LOD) of 8.59 ppb. This approach paves the way for developing cost-effective, energy-efficient, and miniature NO 2 monitoring devices for improved environmental monitoring and enhanced safety in workplaces where NO 2 exposure is a concern.

36 MATERIALS SCIENCE↗

Fiber Optic Thermal Health Monitoring of Aerospace Structures and Materials

A new technique is presented for thermographic detection of flaws in materials and structures by performing temperature measurements with fiber Bragg gratings. Individual optical fibers with multiple Bragg gratings employed as surface temperature sensors were bonded to the surfaces of structures with subsurface defects or thickness variations. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The investigated structures included a 10-ply composite specimen with subsurface delaminations of various sizes and depths. The data obtained from grating sensors were further analyzed with thermal modeling to reveal particular characteristics of the interested areas. These results were found to be consistent with those from conventional thermography techniques. Limitations of the technique were investigated using both experimental and numerical simulation techniques. Methods for performing in-situ structural health monitoring are discussed.

Wu, Meng-Chou↗

Roller Bearing Health Monitoring Using CPLE Frequency Analysis Method

This paper describes a unique vibration signature analysis technique Coherence Phase Line Enhancer (CPLE) Frequency Analysis - for roller bearing health monitoring. Defects of roller bearing (e.g. wear, foreign debris, crack in bearing supporting structure, etc.) can cause small bearing characteristic frequency shifts due to minor changes in bearing geometry. Such frequency shifts are often too small to detect by the conventional Power Spectral Density (PSD) due to its frequency bandwidth limitation. This Coherent Phase Line Enhancer technology has been evolving over the last few years and has culminated in the introduction of a new and novel frequency spectrum which is fully described in this paper. This CPLE technology uses a "key phasor" or speed probe as a preprocessor for this analysis. With the aid of this key phasor, this CPLE technology can develop a two dimensional frequency spectrum that preserves both amplitude and phase that is not normally obtained using conventional frequency analysis. This two-dimensional frequency transformation results in several newly defined spectral functions; i. e. CPLE-PSD, CPLE-Coherence and the CPLE-Frequency. This paper uses this CPLE frequency analysis to detect subtle, low level bearing related signals in the High Pressure Fuel Pump (HPFP) of the Space Shuttle Main Engine (SSME). For many rotating machinery applications, a key phasor is an essential measurement that is used in the detection of bearing related signatures. There are times however, when a key phasor is not available; i. e. during flight of any of the SSME turbopumps or on the SSME High Pressure Oxygen Turbopump (HPOTP) where no speed probe is present. In this case, the CPLE analysis approach can still be achieved using a novel Pseudo Key Phasor (PKP) technique to reconstruct a 1/Rev PKP signal directly from external vibration measurements. This paper develops this Pseudo Key Phasor technique and applies it to the SSME vibration data.

Jong, Jen-Yi↗

Fiber Optic Thermal Health Monitoring of Composites

A recently developed technique is presented for thermographic detection of flaws in composite materials by performing temperature measurements with fiber optic Bragg gratings. Individual optical fibers with multiple Bragg gratings employed as surface temperature sensors were bonded to the surfaces of composites with subsurface defects. The investigated structures included a 10-ply composite specimen with subsurface delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared with the calculations using numerical simulation techniques. Methods and limitations for performing in-situ structural health monitoring are discussed.

Wu, Meng-Chou↗

Fatigue Crack and Porosity Measurement in Composite Materials by Thermographic and Ultrasonic Methods

Many nondestructive methods exist for the detection of localized material anomalies in an otherwise good composite structure. The problem arises when the material system as a whole has degraded during service or was improperly manufactured. Porosity and intra-ply microcracking are two such conditions that in unlined composite pressure vessels can be very troublesome to detect and when linked through the thickness can be critical to mission success. These leak paths may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. Research sought nondestructive methods for quantifying porosity and microcracking in composite tankage. Both thermographic and resonance ultrasound methods have been utilized with artificial neural network and statistical approaches to analyze the data. Resonant ultrasound spectroscopy provides measurements, which are sensitive to fine details in the materials character, such as micro-cracking and porosity. Here, the higher frequency (shorter wavelength) components of the signal train provide more significant interaction with the defects causing the spectral characteristics to shift toward lower amplitudes at the higher frequencies. As the density of the defects increases more interactions occur and more drastic amplitude changes are observed. From a thermal perspective, the higher the defect density the lower the through thickness thermal diffusivity will be. Utilizing a point heat source, and thermographically recording the heat profile with time, diffusivity calculations can be made which in turn can be related to the relative quality of the material. Preliminary experiments to verify the measurable effect on the resonance spectrum of the ultrasonic data to detect microcracking and for porosity detection thermographically are presented. Methods involving supervised and unsupervised artificial neural networks as well as other clustering algorithms are developed for signal identification.

Walker, James L.↗

Fiber Optic Thermal Detection of Composite Delaminations

A recently developed technique is presented for thermographic detection of delaminations in composites by performing temperature measurements with fiber optic Bragg gratings. A single optical fiber with multiple Bragg gratings employed as surface temperature sensors was bonded to the surface of a composite with subsurface defects. The investigated structure was a 10-ply composite specimen with prefabricated delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared and found to be consistent with the calculations using numerical simulation techniques. Also discussed are methods including various heating sources and patterns, and their limitations for performing in-situ structural health monitoring.

Wu, Meng-Chou↗

Determination of electron-hole pair creation energy in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 quaternary semiconductor for room-temperature gamma-ray detection

We report the first-time measurement of the electron-hole pair (ehp) creation energy (W ehp ) in novel Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS) quaternary semiconductor. CZTS in single crystalline form is poised to be the future of large-volume room-temperature gamma-ray detectors due to its excellent compositional homogeneity with highly reduced defects, high-Z (atomic number) constituents, wide bandgap (1.6 eV), and superior charge transport properties. Despite a great deal of study of the material and device properties since its inception, the W ehp in CZTS has not been measured experimentally. Accurate determination of W ehp is essential for calibration of the spectrometer and other theoretical calculations. In this study we have used an absolute calibration approach, which is based on an iterative approach that yields the Wehp as the best-fit parameter. Using a 241 Am alpha emitting radioisotope and a planar CZTS detector, the Wehp in CZTS was calculated to be 4.47 eV. The obtained value has been validated by accurately predicting the peak energy for gamma rays emitted by a 137 Cs source and read by a CZTS detector with different dimensions. The dependences of the calculated W ehp value on the detector dimensions, type of interaction, and effect of charge trapping are also discussed.

42 ENGINEERING↗

Electronic characterization of defects in narrow gap semiconductors: Comparison of electronic energy levels and formation energies in mercury cadmium telluride, mercury zinc telluride, and mercury zinc selenide

The project has evolved to that of using Green's functions to predict properties of deep defects in narrow gap materials. Deep defects are now defined as originating from short range potentials and are often located near the middle of the energy gap. They are important because they affect the lifetime of charge carriers and hence the switching time of transistors. We are now moving into the arena of predicting formation energies of deep defects. This will also allow us to make predictions about the relative concentrations of the defects that could be expected at a given temperature. The narrow gap materials mercury cadmium telluride (MCT), mercury zinc telluride (MZT), and mercury zinc selenide (MZS) are of interest to NASA because they have commercial value for infrared detecting materials, and because there is a good possibility that they can be grown better in a microgravity environment. The uniform growth of these crystals on earth is difficult because of convection (caused by solute depletion just ahead of the growing interface, and also due to thermal gradients). In general it is very difficult to grow crystals with both radial and axial homogeneity.

Patterson, James D.↗