Search NASA⌕ Search

SEARCH · Search NASA

Results for “diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Diurnal observations of basal stem CO2 efflux in three canopy dominant trees in the central Amazon

We explored mechanisms responsible for disturbance-induced shifts in carbon metabolism in forests north of Manaus, Brazil (S2º 38' 17", W60º 09' 25"), using data from a selective logging experiment (BIONTE). BIONTE (the BIOmass and NuTrient Experiment) selective logging treatments were initiated in the mid-1980s and comprised variable removal of commercial tree (not total) species basal area (T1 =32%, T2 = 42%, T3 = 69%), and control plots with no logging (T0). Raw data including tree base diameter (Db), CO2 concentration versus time inside a static stem chamber, and wood density were used to derive stem respiration rates (Rw), wood production rates (Pw), and wood carbon use efficiency (CUE). Changes in tree base diameter (Db; measured at 1.3 m height, or above the buttresses) was used to calculate wood production for individual trees (Pw). Wood density enabled calculation of stem growth rate in the same units as stem respiration (mmol C m-2 s-1). Four trees were randomly selected from five tree growth rate classes for each treatment block, for a total of 20 trees per treatment block, or 80 trees total from the BIONTE plots. Each of the 80 trees selected for the Rw study were outfitted with dendrometer bands (da Silva et al. 2002). Stem respiration was measured using the method described in Chambers et al. (2004). Briefly, an infra-red gas analyzer (LiCor 820) was operated as a closed dynamic chamber with a flow rate of 1.0 L min-1. Polyvinyl chloride (PVC) semi-cylindrical chambers (250–400 mL) were secured to the tree stem near the dendrometer bands using nylon straps. The measurement interval spanned 1–2 min, and the CO2 flux from the stem of each tree was quantified using the enclosed stem area and slope of the stem CO2 concentration versus time.

54 ENVIRONMENTAL SCIENCES↗

Investigating the dielectric constant of barium titanate in a polymer-matrix nanocomposite

Barium titanate (BTO) is a ferroelectric material used in capacitors because of its high bulk dielectric constant. However, the impact of the size of BTO on its dielectric constant is not yet fully understood and is highly contested. Here, we present an investigation into the dielectric constant of BTO nanoparticles with diameters ranging between 50 and 500 nm. BTO nanoparticles were incorporated into acrylonitrile butadiene styrene and injection molded into parallel plate capacitors, which were used to determine nanocomposite dielectric constants. The dielectric constants of BTO nanoparticles were obtained by combining experimental measurements with computational results from COMSOL simulations of ABS-matrix nanocomposites containing BTO. The dielectric constant of BTO was observed to be relatively constant at nanoparticle diameters as small as 200 nm but sharply declined at smaller nanoparticle sizes. Overall, these results will be useful in the development of improved energy storage and power conditioning systems utilizing BTO nanoparticles.

36 MATERIALS SCIENCE↗

Thermal dissipation sensors enter a new age: Navigating frontiers in transpiration and hydrologic function

Thermal dissipation (TD) sensors have been used extensively for a wide array of sap flow applications, and yet recently several limitations of this approach have been identified, including a tendency to underestimate absolute flows, especially in small stems with very high flows. However, when used properly, the TD method remains the most cost effective and reliable approach for determining relative flows in comparison studies. Major advantages of this method include the ability to replicate maximally within trees, across trees of different sizes, and across multiple species to capture the full range of natural variation in the study system. From early studies, such variation has been deemed a major challenge for representing stand-level dynamics. In a series of recent comparison studies, we determined mean sap flux density dynamics within and among groups of trees. These studies were conducted within temperate coniferous forest (n=46), temperate oak savanna (n=36), temperate pine forest (n=49), temperate bottomland hardwood forest (n=23), tropical premontane rainforest (n=43), semiarid subtropical shrubland (n=25), and tropical dry forest (n=15), with a total of 237 sensors. Two study sites were also equipped with eddy covariance systems for determination of stand-level evapotranspiration. Sites subject to high background thermal gradients used the transient thermal dissipation method. Comparisons varied between studies but tended to focus on relative flow differences between species, between wetter and drier microsites, between understory and overstory components, or between wetter and drier periods of the growing season. Except for the shrubland sites, study trees tended to be at least 15-cm diameter and frequently exceeded 50-cm diameter. Results of this cross-site comparison highlight the inherent variation in natural stands and the importance of using large sample sizes. The TD approach remains a valuable and preferred method for the future determination of water use in trees. However, sensor replication can fundamentally impact a study's outcomes and should be more carefully considered in study design. Customized error mitigation strategies are best to address the sources of variation most problematic for a particular study. In conclusion, the development of “smart” calibration approaches that correct for fundamental effects of radial variation inherent in thermal dissipation studies is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

SOC Microstructural Analyzer

This program was designed to analyze the 3-phase microstructure of the electrodes of a solid oxide fuel cell (SOFC) or electrolysis cell (SOEC), both referred to in combination as a solid oxide cell (SOC). It is agnostic to the exact system, so it could be repurposed to analyze any 3-phase microstructure. This tool directly analyzes segmented voxel-based data that has been segmented into phase IDs (1,2,3). The voxels will be analyzed directly for: - tortuosity factors - triple phase boundaries - 2-phase interfacial areas, using a meshed isosurface - mean diameters of each phase, using an inscribed sphere method - standard deviation of the diameters of each phase, from the same inscribed sphere data - connectivity information Comprehensive information is available in the readme file (within the zipped repository in Markdown language, and also available here as a rendered PDF). Please cite this page / DOI, as well as https://doi.org/10.1111/jace.14775, for usage.

3D microstructure↗

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]↗

Optimization of a Welding Procedure for Making Critical Aluminum Welds on the LBNF Absorber Core Block

The LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. A weld quality optimization was performed to produce National Aeronautical Standard 1514 Class I quality welds on the aluminum core blocks. This was not successful in all cases. An existing Gas Tungsten Arc Welding Procedure Specification was fine tuned to minimize, in most cases, and eliminate detect-able tungsten inclusions in the welds. All the weld coupons, however passed welding inspection as per the piping code: ASME B31.3 Normal Fluid Service. Tungsten electrode diameter, type, and manufacturer were varied. Some of the samples were pre-heated and others were not. It was observed that larger diameter electrodes, 5/32 in., with pre-heated joints resulted in welds with the least number of tungsten inclusions. It is hypothesized that thinner electrodes breakdown easily and get lodged into the weld pool during the welding process. This breakdown is further enhanced by the large temperature differential between the un-preheated sample and the hot electrode.

43 PARTICLE ACCELERATORS↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

Slide Test FY 2019 Report

At Los Alamos, the Slide Test was developed in 2019 to investigate whether the mass of a main charge of explosive sliding on a gritty surface, in the absence of impact, is sufficient to heat grit to ignition temperatures in PBX 9501. This is a practical test to address frictional ignition during assembly/disassembly operations at the Pantex Plant. Twenty-seven Slide Tests were performed in total, testing PBX 9501 at various slide velocities, grit diameters, grit patterns, and charge masses. Time-resolved velocimetry of the slide event (from PDV) and spot area of the explosive charge (obtained from image analysis) is reported. High-speed videography is used to diagnose explosive reaction. Eighteen of these tests were performed with a charge mass of 30 lbs at velocities ≤ 4 m s-1 and grit diameters between 75 and 1000 µm. Nine Slide Tests were performed with a 15 lb charge mass at similar parameters. No ignition was observed in any of the tests. These data provide evidence that the mass of a main charge, caused to slide on a surface at the low velocities achievable during routine handling, is insufficient stimulus to heat grit to ignition temperatures. These findings are relevant to risk assessment for explosive handling operations and provide evidence that PBX 9501 is safe within the constraints that were tested. However, because ignitions were not observed in any of the tests, we cannot determine which variables (mass or velocity) dominate the explosive response and to what extent. The absence of observed ignition also precludes the determination of a safety margin. To identify this safety margin, further research would be necessary to define the velocity and/or mass threshold at which ignition occurs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Status of GTA Gear Inspection after Testing in Sodium

The Mechanisms Engineering Test Loop (METL) is an intermediate-scale liquid metal experimental facility that provides purified reactor-grade (R-grade) sodium to various experimental test vessels. In these test vessels, components that are required to operate in an advanced fast reactor can be tested in a prototypical sodium environment. Experiments conducted in METL significantly assist in the development and maturation of systems and components for advanced reactors. The METL facility consists of multiple test segments including: a purification and diagnostic loop (cold trap was designed after EBR-II), two 18” diameter test vessels with 150 L capacities capable of operating in static or dynamic flow at 538°C, two 28” diameter test vessels with 644 L capacities capable of operating in static or dynamic flow at 650°C, a 3,180 L dump tank with 21 instrumentation ports, and the infrastructure to expand capacity in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing the HM-5s and NaIGEM code

We tested the performance of the HM-5 units and the NaIGEM code to determine the uranium enrichment. The uranium materials consist of two groups, the NBS series and the UISO series. The NBS items are U 3 O 8 in aluminum containers with an inner diameter of 7.0 cm and a frontal surface thickness of 2.0 mm. The UISO items are U 3 O 8 stored in doubly encapsulated stainless steel containers with a total thickness of 0.82 mm. The diameter of the inner UISO container is 10.0 cm. Four separate tests were performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of thinned silicon sensors on 8” wafers (CRADA FRA-2015-0015 Final Report)

Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to >200 m 2 for the existing CMS tracker. CMS and ATLAS upgrades will each require more than 200 m 2 of silicon and the CMS High Granularity Calorimeter (HGC) will require more than 600 m 2 . Cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the area of the silicon sensors. A move from 4” and 6” wafers (the only sizes currently available) to 8” diameter in volume production has the potential for savings of tens of millions of dollars in the detector upgrade programs at the Large Hadron Collider (LHC) and future experiments. In addition to large area, the devices must be radiation hard, which can be achieved by the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work.

43 PARTICLE ACCELERATORS↗

Imaging of Calibrated Defects in Additively Manufactured Materials: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. Currently, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. As a solution to NDE of AM, we are developing pulsed thermal imaging which is non-contact, one-sided, and scalable to arbitrary size and shape of the AM parts. Pulsed thermography (PT) system utilizes a high intensity flash lamp to rapidly heat surface of sample, and a high sensitivity fast-frame megapixel infrared (IR) camera to capture data of surface temperature variations. The acquired data cube consists of a stack of surface temperature images taken at different times. Information about material internal defects is extracted by analyzing the data cube. This report provides results of preliminary performance evaluation of pulsed thermal imaging capability in detection of imprinted flaws in AM metallic structures. The flaws were introduced into AM parts as imprinted hemispherical low density regions, consisting of trapped un-sintered metallic powder. Specimens for developed for this study consisted of AM stainless steel 316 and Inconel 718 plates. The diameters of imprinted defects varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. Pulsed thermal tomography (PTT) processes the measured data cube to obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. PTT has been previously used in imaging of similar size flat bottom hole (FBH) simulated defects in stainless steel 316 and Inconel 718 specimens. In the study involving AM specimens, PTT imaging results have shown that 1mm-diameter defects located 1mm and 2mm below the surface of specimens were detectable. Larger size defects were detectable at greater depth. We also explored an alternative approach to detection of material flaws in PT data cube, which is using neural learning-based approach to blind source separation. Detection of small material defects requires finding features in the data cube which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with phtotothermics, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

36 MATERIALS SCIENCE↗

NNSS Soils Monitoring: Plutonium Valley (CAU 366) FY2019

Desert Research Institute (DRI) conducted a field assessment of the potential for radionuclide-contaminated soil to be transported from the Plutonium Valley Dispersion Sites Contamination Area (CA) because of both wind and storm water runoff. This activity supported U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Plutonium Valley Dispersion Sites Corrective Action Unit (CAU) 366. The DRI task was intended to identify the likely mechanism(s) of transport and determine the meteorological conditions that might cause the movement of radionuclide-contaminated soils. The emphasis of the work was on collecting sediment transported by channelized storm runoff and measuring airborne dust concentrations and associated wind conditions. These data will facilitate an appropriate post-closure monitoring program. In 2011, DRI installed meteorological monitoring stations north and south of the Plutonium Valley CA—known as Pu Valley North and Pu Valley South, respectively—as well as a fluvial sediment sampling station within the CA. Since installation, temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, volumetric soil moisture content, and airborne particulate concentrations have been collected at both meteorological stations. The maximum, minimum, and average or total (as appropriate) for each of these parameters were recorded for each 10-minute interval. The sediment sampling station included an automatically activated sampling pump with collection bottles for suspended sediment, which was activated when sufficient flow was present in the channel, and passive traps for bedload material that was transported down the channel during runoff events. This report presents data collected from these stations during fiscal year (FY) 2019. During the FY2019 (October 1, 2018, through September 30, 2019) reporting period, the warmest month was July and the coldest month was February. Monthly total solar radiation was highest in June or July (depending on the station) and lowest in December. Monthly mean wind speeds were highest during February. At the Pu Valley North station, winds were commonly northerly, northwesterly, and southerly. At the Pu Valley South station, the wind direction was more variable and winds frequently came from most directions, excluding westerly and northwesterly winds. Winds above 15.0 miles per hour (mph) (24.1 kilometers per hour [km/hr]) were frequently southerly at both stations, and less-frequent strong winds were northerly (at the Pu Valley South station) or northwesterly (at the Pu Valley North station). Monthly average relative humidity ranged from 18 percent in August to 62 percent in January and February. Monthly total precipitation ranged from zero at both stations in September to 2.23 inches (in) (56.6 millimeters [mm]) during February at the Pu Valley South station and 2.09 in (53.1 mm) during March at the Pu Valley North station. From October 1, 2018, through September 30, 2019, the total precipitation was 8.23 in (209 mm) and 8.15 in (207 mm) at the Pu Valley South and Pu Valley North stations, respectively. The largest daily precipitation totals of 1.46 in (37.1 mm) and 1.14 in (29.0 mm) occurred at the Pu Valley South and Pu Valley North stations, respectively, on March 6, 2019. However, the ISCO autosampler was not activated during any storm event in FY2019 because the channel water depth measurements were insufficient for suspended sediment sample collection. Additionally, because no significant flow through the channel was indicated, no bedload samples were collected. Light breezes of 0.0 mph to 5.0 mph (0.0 km/hr to 8.0 km/hr) occurred most frequently (approximately 55 percent to 57 percent of the time). The frequency of occurrence diminished exponentially as the wind speed increased such that winds in excess of 25.0 mph (40.2 km/hr) occurred less than 0.01 percent of the time. Winds in excess of 15.0 mph (24.1 km/hr) were most commonly southerly, which is likely controlled by the topography of the valley because topographic highs define the east and west sides of the valley and converge toward the north.The concentrations of PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 micrometers [μm]) and PM10 (particulate matter with an aerodynamic diameter ≤10 μm) in the air generally increase as wind speed increases. However, the particle profiler at the Pu Valley South station regularly malfunctioned, which resulted in poor data quality and a limited period of record within FY2019. Therefore, discussion of the annual dust observations is mostly limited to the Pu Valley North station. At the Pu Valley North station, significant increases in windblown dust concentrations were observed when wind speeds exceeded 15.0 mph (24.1 km/hr), especially during southerly winds. When all wind speeds were considered, high dust concentrations at the Pu Valley North station were frequently associated with northerly, northwesterly, or southerly winds. The majority of PM10 transport at the Pu Valley North station occurred when winds were blowing northerly and northwesterly because of the high frequency of winds up to 15.0 mph (24.1 km/hr). The ratio of PM10 to PM2.5 is a qualitative indicator of the proximity of dust sources to the observation point and the values of the PM10 to PM2.5 ratio tend to be higher nearer to the source. The PM10 to PM2.5 ratio increased from 1.2 to 2.8 with higher wind speeds at the Pu Valley North station. This increase suggests that some locally sourced PM10 was present in the air when local winds exceeded 15.0 mph (24.1 km/hr). Local dust suspension is interpreted during major dust events when peaks in the PM10 to PM2.5 ratio occur simultaneously with the maximum wind speed and the peak PM10 concentration. Analysis of the five major dust events in FY2019 revealed that northerly winds were dominant in three events and southerly winds were dominant in two events. Local suspension of dust within Plutonium Valley is suspected to have occurred during two of the five major events (April 9, 2019, and September 28 to 29, 2019), and a nonlocal source of dust is presumed for the three other major dust events (October 14, 2018; May 16, 2019; and September 2, 2019). The three suspected regional dust transport events exhibited winds that typically did not exceed the 15.0 mph (24.1 km/hr) wind speed threshold for local dust transport and featured PM10 to PM2.5 ratios that indicate large-scale regional dust transport. Similar event characteristics (e.g., wind speed and PM10 concentration) were observed at air monitoring stations approximately 70 mi (113 km) to the northwest within the Tonopah Test Range (TTR). Therefore, these three regional events may not reflect transport from the Plutonium Valley CA. Routine monitoring of meteorological and hydrologic parameters at Plutonium Valley has been discontinued at the request of EM NV, effective at the conclusion of FY2019. Environmental data acquisition has been completed, and both Pu Valley North and Pu Valley South meteorological stations within Plutonium Valley as well as the ISCO autosampler station within the CA were removed on October 14, 2019.

54 ENVIRONMENTAL SCIENCES↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

20 FOSSIL-FUELED POWER PLANTS↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

42 ENGINEERING↗

Estimating a protection factor from homemade facemasks for Los Alamos radioactive aerosols

The Los Alamos National Laboratory has required usage of facemasks “whenever interacting with or near others." The present document estimates the respiratory protection factor of homemade facemasks to be 1.4 and 1.2 for aerosol particles, below and above 0.3 μm diameter, respectively. This includes an estimated leakage of 70% and 52% for aerosol particles below and above 0.3 μm diameter, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Laser Transport System Vacuum Simulations and LED Atom Tracker

MAGIS-100 is an experiment using atom interferometry on strontium atoms in a 100m vacuum chamber. The laser travels through a laser transport system (LTS) before going down the chamber. Two projects were completed over the course of the internship. One project was conducting vacuum simulations on the LTS to ensure it meets the experimental pressure requirement of 10-11 torr. This was done by characterizing the pressure profile with variations in pump size, pump spacing, and orifice size. The initial design of the LTS included one 30 L/s ion pump in the high vacuum (HV) region, a lens mount with holes of diameter 0.788”, and three 150 L/s ion pumps in the ultra-high vacuum (UHV) region. After adjusting these variables, it was concluded that the lens mount holes could be reduced to 0.200” in diameter and one 150 L/s ion pump in the UHV could be removed and still meet the experimental requirements. The other project was to design an LED atom tracker that shows the position of the strontium atoms in the 100m shaft. This will help with public outreach by allowing visitors to have a visual of the experiment. An Arduino Uno and Arduino Due were programmed using classical physics formulas to direct the RGB LED strips to flash in sync with the falling atoms. The requirements for powering and connecting the hardware were calculated and recommendations for scaling the system to 100m were made.

43 PARTICLE ACCELERATORS↗