Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

Improvement of Transmission Line Ampacity Utilization by Weather-Based Dynamic Line Rating

Most of the existing overhead transmission lines (TLs) are assigned a static rating by considering the conservative environmental conditions (e.g., high ambient temperature and low wind speed). Such a conservative approach often results in underutilization of line ampacity because the worst conditions prevail only for a short period of time during the year. Dynamic line rating (DLR) utilizes local meteorological conditions and grid loadings to adaptively compute additional line ampacity headroom that may be available due to favorable local environmental conditions. This paper details Idaho National Laboratory-developed weather-based DLR, which utilizes a state-of-the-art general line ampacity state solver for real-time computation of thermal ratings of TLs. Performance of the proposed DLR solution is demonstrated in existing TL segments at AltaLink, Canada, and the potential benefits of the proposed DLR for enhanced transmission ampacity utilization are quantified. Moreover, we investigated a hypothetical case for emulating the impact of an additional wind plant near the test grid. Furthermore, the results for the given system and data configurations demonstrated that real-time ratings were above the seasonal static ratings for at least 76.6% of the time, with a mean increase of 22% over the static rating, thereby demonstrating huge potential for improvement on ampacity utilization.

17 WIND ENERGY↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗

Effect of Hot Deformation on Texture and Microstructure in Fe-Mn Austenitic Steel During Compression Loading

Hot compression tests of a new high-Mn austenitic steel were carried out at deformation temperatures of 700, 800, 900, and 1000 °C under strain rate of 0.01 s{sup −1}. The hot deformation behavior was investigated by the analyses of flow curves, texture, and deformed microstructures. Microstructures of the deformed specimens and macrotexture were examined using electron backscatter diffraction and x-ray diffraction methods, respectively. The results showed that the flow stress depended strongly on the deformation temperature and decreased by increasing deformation temperature. The microstructural evidence indicated that the dynamic recrystallization (DRX) process of experimental steel was initiated at 800 °C with necklace structure. The volume fraction of DRX grains was considerably increased by increasing deformation temperature to 1000 °C. Texture of the DRX grains tended to become a weak texture and was associated with the formation of Goss and R-Cube components. Meanwhile, martensitic transformation was detected in the hot-deformed austenite. The martensitic transformation was the most difficult in the DRX grains because of the effect of small grain size. The tendency of transformation was decreased after compression at 1000 °C.

36 MATERIALS SCIENCE↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

In situ observation of fracture processes in high-strength concretes and limestone using high-speed X-ray phase-contrast imaging

The mechanical properties and fracture mechanisms of geomaterials and construction materials such as concrete are reported to be dependent on the loading rates. However, the in situ cracking inside such specimens cannot be visualized using traditional optical imaging methods since the materials are opaque. In this study, the in situ sub-surface failure/damage mechanisms in Cor-Tuf (a reactive powder concrete), a high-strength concrete (HSC) and Indiana limestone under dynamic loading were investigated using high-speed synchrotron X-ray phase-contrast imaging. Dynamic compressive loading was applied using a modified Kolsky bar and fracture images were recorded using a synchronized high-speed synchrotron X-ray imaging set-up. Three-dimensional synchrotron X-ray tomography was also performed to record the microstructure of the specimens before dynamic loading. In the Cor-Tuf and HSC specimens, two different modes of cracking were observed: straight cracking or angular cracking with respect to the direction of loading. In limestone, cracks followed the grain boundaries and voids, ultimately fracturing the specimen. Cracks in HSC were more tortuous than the cracks in Cor-Tuf specimens. The effects of the microstructure on the observed cracking behaviour are discussed. This article is part of the themed issue ‘Experimental testing and modelling of brittle materials at high strain rates’.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

Remote Monitoring of the Structural Health of Hydrokinetic Composite Turbine Blades (Final Report)

A health monitoring approach is investigated for hydrokinetic turbine blade applications. In-service monitoring is critical due to the difficult environment for blade inspection and the cost of inspection downtime. Composite blade designs have advantages that include long life in marine environments and great control over mechanical properties. Experimental strain characteristics are determined for static loads and free-vibration loads. These experiments are designed to simulate the dynamic characteristics of hydrokinetic turbine blades. Carbon/epoxy symmetric composite laminates are manufactured using an autoclave process. Four-layer composite beams, eight-layer composite beams, and two-dimensional eight-layer composite blades are instrumented for strain. Experimental results for strain measurements from electrical resistance gages are validated with theoretical characteristics obtained from in-house finite-element analysis for all sample cases. These preliminary tests on the composite samples show good correlation between experimental and finite-element strain results. A health monitoring system is proposed in which damage to a composite structure, e.g. delamination and fiber breakage, causes changes in the strain signature behavior. The system is based on embedded strain sensors and embedded motes in which strain information is demodulated for wireless transmission. In-service monitoring is critical due to the difficult environment for blade inspection and the cost of inspection downtime. Composite blade designs provide a medium for embedding sensors into the blades for in-situ health monitoring. The major challenge with in-situ health monitoring is transmission of sensor signals from the remote rotating reference frame of the blade to the system monitoring station. In the presented work, a novel system for relaying in-situ blade health measurements in hydrokinetic systems is described and demonstrated. An ultrasonic communication system is used to transmit sensor data underwater from the rotating frame of the blade to a fixed relay station. Data are then broadcast via radio waves to a remote monitoring station. Results indicate that the assembled system can transmit simulated sensor data with an accuracy of ±5% at a maximum sampling rate of 500 samples/sec. A power investigation of the transmitter within the blade shows that continuous max-sampling operation is only possible for short durations (~days), and is limited due to the capacity of the battery power source. However, intermittent sampling, with long periods between samples, allows for the system to last for very long durations (~years). Finally, because the data transmission system can operate at a high sampling rate for short durations or at a lower sampling rate/higher duty cycle for long durations, it is well-suited for short-term prototype and environmental testing, as well as long-term commercially-deployed hydrokinetic machines.

13 HYDRO ENERGY↗

Simulating Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on compliant solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within single-axis, solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare time series and statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability and the differences between positive and negative tilt angles.

fluid↗

Packaging a 650V/400A GaN Half-bridge Power Module with Ultra-low Parasitics for Electric Vehicle Drive Applications

This paper proposes a compact and efficient half-bridge power module with three 650 V / 150 A GaN dies in parallel. The power module incorporates a main power printed circuit board (PCB), an interface PCB, and a flex PCB to achieve low parasitics in both power loop and gate-side connection, resolving the issue of high parasitics typically encountered with wire bonding in high-current applications. Additionally, the interface PCB decouples the design constraints between the power loop and the gate loops. The proposed design is optimized with a vertical loop configuration to reduce power loop inductance through magnetic flux cancellation. Finite element analysis indicates that the power loop inductance is 0.58 nH at 100 MHz, while the maximum die junction temperature reaches 131 °C under an ambient temperature of 65 °C and a load current of 385 A. The proposed multi-piece PCB structure reduces the inductance of the drive circuit to minimize EMI and to mitigate false triggering. At the same time, it reduces impedance mismatches across different driver circuits, thereby achieving dynamic current sharing in multi-chip parallel configurations. Under simulation conditions of 400 V / 385 A, the current imbalance among chips was limited to 5 A. A 400 V / 385 A double-pulse test was conducted to experimentally validate the performance of the proposed power module.

30 DIRECT ENERGY CONVERSION↗

Development of Multilayer Sinter Cladding of Cold Work Tool Steel on Hadfield Steel Plates for Wear-Resistant Applications

Machinery components used for mining and mineral processing activities are often subjected to high impact loads and wear which have placed demands for the development of materials with high resistance to dynamic loads and aggressive wear conditions. In this study, a multilayered cladding of high alloyed cold work tool steel (X245VCrMo9-4), interlayered with Hadfield steel (X120Mn12) plates, which was also used as substrate using super-solidus liquid-phase sintering technique was investigated. A stack of the cold work tool steel powder was prepared with interlayered X120Mn12 steel plates in an alumina crucible at tap density with the substrate placed on it and was sintered in a vacuum furnace at 1250 °C at a heating rate of 10 K/min, held for 30 min under a nitrogen atmosphere at 0.08 MPa and furnace-cooled. Sample from the as-sintered cladding was subjected to austenization at 1000 °C, quenched in oil and tempered at 150 °C for 2 h. Samples were subjected to microstructural examination using optical and scanning electron microscopy. The microstructural investigations were supplemented by hardness and impact wear tests. Computational thermodynamics was used to support experimental findings. The results revealed that a near-net densification of the sintered X245 was achieved with 99.93 ± 0.01% density. The sintered X245 was characterized by a dispersion of vanadium carbonitride precipitates, especially at the grain boundaries. The heat-treated X245 sample had the highest hardness of 680 ± 7 HV30 due to the matrix of tempered martensitic microstructure when compared to as-sintered with hardness of 554 ± 2 HV30. The X245/X120 interface was characterized by diffusion of Cr, Mo, Mn and C, which resulted in metallurgical bonding between the cladded materials. The impact wear resistance of the sintered X245 was eight times that of the X120; hence, a tough and wear-resistant tool is anticipated when the X120 work hardened in service.

36 MATERIALS SCIENCE↗

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems -- a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms -- were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sulfur-doped graphene anchoring of ultrafine Au 25 nanoclusters for electrocatalysis

The biggest challenge of exploring the catalytic properties of under-coordinated nanoclusters is the issue of stability. We demonstrate herein that chemical dopants on sulfur-doped graphene (S-G) can be utilized to stabilize ultrafine (sub-2 nm) Au 25 (PET)18 clusters to enable stable nitrogen reduction reaction (NRR) without significant structural degradation. The Au 25 @S-G exhibits an ammonia yield rate of 27.5μgNH 3 ∙ mg Au -1 ∙ h -1 at -0.5 V with faradic efficiency of 2.3%. More importantly, the anchored clusters preserve ~ 80% NRR activity after four days of continuous operation, a significant improvement over the 15% remaining ammonia production rate for clusters loaded on undoped graphene tested under the same conditions. Isotope labeling experiments confirmed the ammonia was a direct reaction product of N 2 feeding gas instead of other chemical contaminations. Ex-situ X-ray photoelectron spectroscopy and X-ray absorption near-edge spectroscopy of post-reaction catalysts reveal that the sulfur dopant plays a critical role in stabilizing the chemical state and coordination environment of Au atoms in clusters. Further ReaxFF molecular dynamics (RMD) simulation confirmed the strong interaction between Au nanoclusters (NCs) and S-G. Furthermore, this substrate-anchoring process could serve as an effective strategy to study ultrafine nanoclusters’ electrocatalytic behavior while minimizing the destruction of the under-coordinated surface motif under harsh electrochemical reaction conditions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Wave transmission through silicone foam pads in a compression Kolsky bar apparatus. Comparisons between simulations and measurements.

This memo concerns the transmission of mechanical signals through silicone foam pads in a compression Kolsky bar set-up. The results of numerical simulations for four levels of pad pre-compression and two striker velocities were compared directly to test measurements to assess the delity of the simulations. The nite element model simulated the Kolsky tests in their entirety and used the hyperelastic `hyperfoam' model for the silicone foam pads. Calibration of the hyperfoam model was deduced from quasi-static compression data. It was necessary, however, to augment the material model by adding sti ness proportional damping in order to generate results that resembled the experimental measurements. Based on the results presented here, it is important to account for the dynamic behavior of polymeric foams in numerical simulations that involve high loading rates.

47 OTHER INSTRUMENTATION↗

Analysis of the Ultra-fast Switching Dynamics in a Hybrid MOSFET/Driver

The turn-on dynamics of a power MOSFET during ultra-fast, {approx} ns, switching are discussed in this paper. The testing was performed using a custom hybrid MOSFET/Driver module, which was fabricated by directly assembling die-form components, power MOSFET and drivers, on a printed circuit board. By using die-form components, the hybrid approach substantially reduces parasitic inductance, which facilitates ultra-fast switching. The measured turn on time of the hybrid module with a resistive load is 1.2 ns with an applied voltage of 1000 V and drain current of 33 A. Detailed analysis of the switching waveforms reveals that switching behavior must be interpreted differently in the ultra-fast regime. For example, the gate threshold voltage to turn on the device is observed to increase as the switching time decreases. Further analysis and simulation of MOSFET switching behavior shows that the minimum turn on time scales with the product of the drain-source on resistance and drain-source capacitance, R{sub DS(on)}C{sub OSS}. This information will be useful in power MOSFET selection and gate driver design for ultra-fast switching applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting Instability and the Effect of Wind Loading on Single-Axis Trackers

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. In our ongoing DuraMAT project, we are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software, highlighting recent user-interface and algorithm developments, before presenting the latest outcomes from our ongoing validation campaign in which we analyze and compare with experimental data obtained from a DuraMAT 1 project. From there, we will present simulated results from a larger, multi-row array and highlight relationships between varying tracker angles and stability as measured by different experimentally validated metrics.

fluid structure interaction↗

On computing the evolution of temperature for materials under dynamic loading

Modeling and simulation of the dynamic response of materials is important to many applications including the development of armor systems, understanding the safety of explosives, and assessing the crashworthiness of vehicles. Within such applications it is often critical to accurately compute the evolution of the temperature because it is a state variable that affects the kinetics of competing active processes within the material (e.g., dislocation motion, phase transformation, decomposition). Depending on the selection of an independent state variable, e.g. temperature or entropy, the approach for computing temperature is well understood based on the thermodynamic framework attributed to Coleman and Noll. However, different computational codes used for modeling the dynamic response of materials adopt different independent state variables. In this work, two thermodynamically consistent strategies for computing the temperature of a coupled thermodynamic state are compared and implemented into two different Lagrangian computational codes. The equivalence of these two approaches is established through the numerical solutions of several test problems. Finally, the implication of various approximations made to each of these approaches within the literature are assessed in the context of uniaxial stress conditions (split Hopkinson pressure bar experiments) and uniaxial strain conditions (plate impact experiments). Here, it is shown that the temperature rate or energy partition approaches are equivalent when implemented in their complete forms, but that several common simplifying assumptions, that are warranted in the case of uniaxial stress, lead to significant errors in the resulting Hugoniot state for plate impact.

36 MATERIALS SCIENCE↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗