At least 577 records · Page 32

Observed relationships between electric fields and auroral particle precipitation.

Simultaneous electric field and plasma observations with the low-altitude polar-orbiting satellite Injun 5 have provided a comprehensive survey of convection electric fields and their association with magnetospheric plasma phenomena. The most prominent features of the convection electric fields are reversals located at high magnetic latitudes, with generally antisunward convection poleward and sunward convection equatorward of the electric field reversal location. The electric field reversal is interpreted as the boundary between open and closed magnetic field lines. During local day the electric field reversal is observed to coincide with the equatorward boundary of the polar cusp. The plasma flow in the dayside polar cusp region is dominantly E-W, away from the stagnation point, the convection velocities typically being about 1 km/sec. At local evening, 'inverted V' electron precipitation bands are observed near or at the position of the electric field reversal. In the local late-evening sector the electric field reversal becomes less distinct, and often no single well-defined electric field reversal can be identified. In all cases the inverted V electron precipitation events are closely associated with large, typically greater than 30 mV/m, irregular electric field fluctuations with time scales of a few seconds or less.

Gurnett, D. A.↗

Global electric field determination in the Earth's outer magnetosphere using charged particles

Although many properties of the Earth's magnetosphere have been measured and quantified in the past 30 years since it was discovered, one fundamental (for a zeroeth order magnetohydrodynamic (MHD) equilibrium) measurement was made infrequently and with poor spatial coverage: the global electric field. This oversight is in part due to the difficulty of measuring a plasma electric field, and in part due to the difficulty of measuring a plasma electric field, and in part due to the neglect of theorists. However, there is renewed interest in the convection electric field, since it has been realized that it is vital for understanding many aspects of the magnetosphere: the global MHD equilibrium, reconnection rates, Region 2 Birkeland currents, magnetosphere-ionosphere coupling, ring current and radiation belt transport, substorm injections, acceleration mechanisms, etc. Unfortunately the standard experimental methods have not been able to synthesize a global field (excepting the pioneering work of McIlwain's geostationary models), and we are left with an overly simplistic theoretical field, the Volland-Stern electric field mode. Again, single point measurements of the plasma pause were used to infer the appropriate amplitudes of the model, parameterized by Kp (Maynard & Chen, JGR 1975). Although this result was never intended to be the definitive electric field model, it has gone nearly unchanged for 15 years. However, the data sets being taken today require a great deal more accuracy than can be provided by the Volland-Stern model. Nor has the variability of the electric field shielding been properly addressed, although effects of penetrating magnetospheric electric fields has been seen in mid- and low-latitude ionospheric data sets. The growing interests in substorm dynamics also requires a much better assessment of the electric fields responsible for particle injections. Thus, we proposed and developed algorithms for extracting electric fields from particle data taken in the earth's magnetosphere. As a test of the effectiveness of these techniques, we analyzed data taken by the AMPTE/CCE spacecraft in equatorial orbit between 1984-1988. Some analytic tools had to be developed before construction of computer algorithms, and they are discussed.

Eastman, T.↗

Electric Propulsion Platforms at DFRC

NASA Dryden Flight Research Center is a world-class flight research facility located at Edwards AFB, CA. With access to a 44 sq. mile dry lakebed and 350 testable days per year, it is the ideal location for flight research. DFRC has been undertaking aircraft research for approximately six decades including the famous X-aircraft (X-1 through X-48) and many science and exploration platforms. As part of this impressive heritage, DFRC has garnered more hours of full-sized electric aircraft testing than any other facility in the US, and possibly the world. Throughout the 80 s and 90 s Dryden was the home of the Pathfinder, Pathfinder Plus, and Helios prototype solar-electric aircraft. As part of the ERAST program, these electric aircraft achieved a world record 97,000 feet altitude for propeller-driven aircraft. As a result of these programs, Dryden s staff has collected thousands of man-hours of electric aircraft research and testing. In order to better answer the needs of the US in providing aircraft technologies with lower fuel consumption, lower toxic emissions (NOx, CO, VOCs, etc.), lower greenhouse gas (GHG) emissions, and lower noise emissions, NASA has engaged in cross-discipline research under the Aeronautics Research Mission Directorate (ARMD). As a part of this overall effort, Mark Moore of LaRC has initiated a cross-NASA-center electric propulsion working group (EPWG) to focus on electric propulsion technologies as applied to aircraft. Electric propulsion technologies are ideally suited to overcome all of the obstacles mentioned above, and are at a sufficiently advanced state of development component-wise to warrant serious R&D and testing (TRL 3+). The EPWG includes participation from NASA Langley Research Center (LaRC), Glenn Research Center (GRC), Ames Research Center (ARC), and Dryden Flight Research Center (DFRC). Each of the center participants provides their own unique expertise to support the overall goal of advancing the state-of-the-art in aircraft electric propulsion technologies. DFRC will leverage its vast experience in flight test to assist in the integration and flight test phases of any electric propulsion program. DFRC s core competencies, that have particular relevance to the goals of the EPWG, include flight research planning and execution and providing aircraft test beds for researching and testing electric propulsion concepts and equipment. There are three flight regimes that the EPWG is focusing on: subsonic small GA and UAV, subsonic transport class, and supersonic. DFRC proposes two classes of test bed aircraft, to answer the early- and mid-phase testing requirements of all flight regimes the EPWG is concerned with. First, a highly efficient PIK motor glider will be used to test concepts and equipment associated with the subsonic GA and UAV aircraft regime (N+1). Second, a small fleet of subscale remotely-piloted aircraft test beds, similar to the X48B Blended Wing Body aircraft tested at Dryden, will be developed to answer the unique testing requirements of the subsonic GA and UAV, subsonic transport and possibly the supersonic class of aircraft (N+2, N+3). These aircraft can be tested in either serial stages or concurrent stages, depending on the actual test requirements and program schedules. Both classes of test bed aircraft are described below.

Baraaclough, Jonathan↗

Wireless Open-Circuit In-Plane Strain and Displacement Sensor Requiring No Electrical Connections

A wireless in-plane strain and displacement sensor includes an electrical conductor fixedly coupled to a substrate subject to strain conditions. The electrical conductor is shaped between its ends for storage of an electric field and a magnetic field, and remains electrically unconnected to define an unconnected open-circuit having inductance and capacitance. In the presence of a time-varying magnetic field, the electrical conductor so-shaped resonates to generate harmonic electric and magnetic field responses. The sensor also includes at least one electrically unconnected electrode having an end and a free portion extending from the end thereof. The end of each electrode is fixedly coupled to the substrate and the free portion thereof remains unencumbered and spaced apart from a portion of the electrical conductor so-shaped. More specifically, at least some of the free portion is disposed at a location lying within the magnetic field response generated by the electrical conductor. A motion guidance structure is slidingly engaged with each electrode's free portion in order to maintain each free portion parallel to the electrical conductor so-shaped.

Woodard, Stanley E.↗

System and method for implantable electrical connector

A high density electrical connector system is disclosed which may make use of first and second connector components. The first connector component has a first substrate with a first plurality of electrical feedthroughs and at least a first plurality of electrically conductive bond pads in communication with the first plurality of electrical feedthroughs. The second connector component has a second substrate with a second plurality of electrical feedthroughs and at least a second plurality of electrically conductive bond pads in communication with the second plurality of electrical feedthroughs. An electrical coupling subsystem is disposed between the first and second connector components and makes electrical contact between associated pairs of the first and second pluralities of electrically conductive bond pads. A plurality of fasteners may be used for clamping the first and second connector components in facing relationship.

Shah, Kedar G.↗

Real-time forecasting of electricity demand in a streams-based architecture with applications

A streams platform is used. Multiple streams of electricity usage data are received, each from an electrical meter providing periodic updates to electrical usage for devices connected to the electrical meter. Weather information is received corresponding to locations where the electrical meters are. Real-time predictive modeling of electricity demand is performed based on the received multiple streams of electricity usage data and the received weather information, at least by performing: updating a state space model for electrical load curves using the usage data from the streams and the weather, wherein the updating uses current load observations for the multiple streams for a current time period; and creating forecast(s) for the electricity demand. The forecast(s) of the electricity demand are output. Appliance-level predictions may be made and used, and substitution effects and load management functions may be performed.

Ghosh, Soumyadip↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Electron acceleration by parallel and perpendicular electric fields during magnetic reconnection without guide field

In this work, electron acceleration due to the electric field parallel to the background magnetic field during magnetic reconnection with no guide field is investigated by theory and two-dimensional electromagnetic particle-in-cell simulations and compared with acceleration due to the electric field perpendicular to the magnetic field. The magnitude of the parallel electric potential shows dependence on the ratio of the plasma frequency to the electron cyclotron frequency as (ω pe /Ω e ) -2 and on the background plasma density as N$^{-½}_{b}$ . In the Earth's magnetotail, the parameter ω pe /Ω e ~9 and the background (lobe) density can be of the order of 0.01 cm -3 , and it is expected that the parallel electric potential is not large enough to accelerate electrons up to 100 keV. Therefore, we must consider the effect of the perpendicular electric field to account for electron energization in excess of 100 keV in the Earth's magnetotail. Trajectories for high-energy electrons are traced in a simulation to demonstrate that acceleration due to the perpendicular electric field in the diffusion region is the dominant acceleration mechanism, rather than acceleration due to the parallel electric fields in the exhaust regions. For energetic electrons accelerated near the X line due to the perpendicular electric field, pitch angle scattering converts the perpendicular momentum to the parallel momentum. On the other hand, for passing electrons that are mainly accelerated by the parallel electric field, pitch angle scattering converting the parallel momentum to the perpendicular momentum occurs. In this way, particle acceleration and pitch angle scattering will generate heated electrons in the exhaust regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Seasonality and trade in hydro-heavy electricity markets: A case study with the West Africa Power Pool (WAPP)

Hydroelectric power plants account for 25% of West Africa's total installed capacity. In general, electricity generated by these plants is seasonal and intra-annual fluctuation has a considerable impact on electricity supply and cross-border electricity trade. We soft-linked a global hydrologic model to a multi-region capacity expansion and planning model for the West Africa Power Pool (WAPP) to examine the effects of seasonality in hydropower electricity generation on electricity trade, as well as the economic benefits of unconstrained cross-border electricity trade. We found that transitioning from rainy to dry season decreases hydroelectricity generation by an average of 40% in a normal year across the region. Between 2018 and 2050, satisfying the region's electricity demand will require significant capital investment; nevertheless, extending from current bilateral electricity trade agreements to a fully competitive cross-border electricity trade will result in net annual savings of $3 billion in 2015 USD. To achieve year-round energy security, countries should plan ahead and diversify their energy sources to ensure that supply reliability can be maintained in the case of lower supply during the dry season.

13 HYDRO ENERGY↗

Managing the Electricity-Gas Interface: Current Environment and Emerging Solutions

Natural gas generators are now the largest producers of electricity in the United States and the largest single end-use consumer of natural gas. Natural gas markets, which first developed to meet commercial and residential heating demands during winter months, are now entwined with electricity markets, which developed when natural gas provided a much lower fraction of total fuel supply for the electricity market. More coordination, both in daily operations and long-term planning, is required to ensure the continued supply of reliable electricity and natural gas. This report provides an overview of the evolution and current state of electricity and natural gas markets in the United States and summarizes the ways in which the two industries interact. The report describes areas warranting greater coordination between the natural gas and electricity industries. This report also discusses the current state of natural gas and electricity models and the need for integrated models that include dynamic simulations of pipeline operations, especially when large amounts of variable generation exists in the electrical system. It outlines current modeling work being done to better simulate operations and planning of both systems.

54 ENVIRONMENTAL SCIENCES↗

Climate-Water Impacts on Interconnection-Scale Electricity System Planning

A growing literature emphasizes the importance of integrating climate change impacts into electricity system planning. Rising average temperatures can increase and shift electricity demand while reducing generator and transmission efficiency. Changes to water availability and quality can reduce the output of thermally cooled generators and hydropower. Electric power grids across the US and globally are undergoing transformational changes that present new opportunities and challenges to reliability assurance. However, electric utilities and system operators have limited internal capabilities to incorporate these effects into planning practices. This work addresses gaps in utility and system planner practices by integrating climate-water-electricity expertise from universities and U.S. Department of Energy National Laboratories with electricity system planners and stakeholders in the Western Electricity Coordinating Council (WECC). Using a highly collaborative approach, global climate model data, high-resolution hydrology models, and long-term electric sector capacity expansion tools are employed to analyze a range of climate outcomes for future electricity scenarios aligned with recent WECC planning studies. Doing so allows WECC to expand its climate-agnostic planning assessments to consider how future temperature and precipitation patterns could influence generation and transmission planning. We explore how changes to climate-water conditions can affect power plant investment and operation, system economics, and environmental impacts, providing an expanded perspective on interconnection-wide decision making under climate uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Robust planning of dynamic wireless charging infrastructure for battery electric buses

Battery electric buses with zero tailpipe emissions have great potential in improving environmental sustainability and livability of urban areas. However, the problems of high cost and limited range associated with on-board batteries have substantially limited the popularity of battery electric buses. The technology of dynamic wireless power transfer (DWPT), which provides bus operators with the ability to charge buses while in motion, may be able to effectively alleviate the drawbacks of electric buses. In this paper, we address the problem of simultaneously selecting the optimal location of the DWPT facilities and designing the optimal battery sizes of electric buses for a DWPT electric bus system. The problem is first constructed as a deterministic model in which the uncertainty of energy consumption and travel time of electric buses is neglected. The methodology of robust optimization (RO) is then adopted to address the uncertainty of energy consumption and travel time. The affinely adjustable robust counterpart (AARC) of the deterministic model is developed, and its equivalent tractable mathematical programming is derived. Both the deterministic model and the robust model are demonstrated with a real-world bus system. The results of our study demonstrate that the proposed deterministic model can effectively determine the allocation of DWPT facilities and the battery sizes of electric buses for a DWPT electric bus system; and the robust model can further provide optimal designs that are robust against the uncertainty of energy consumption and travel time for electric buses.

25 ENERGY STORAGE↗

Anisotropic electrical and thermal conductivity in Bi{sub 2}AE{sub 2}Co{sub 2}O{sub 8+δ} [AE = Ca, Sr{sub 1−x}Ba{sub x} (x = 0.0, 0.25, 0.5, 0.75, 1.0)] single crystals

Bi{sub 2}AE{sub 2}Co{sub 2}O{sub 8+δ} (AE represents alkaline earth), constructed by stacking of rock-salt Bi{sub 2}AE{sub 2}O{sub 4} and triangle CoO{sub 2} layers alternatively along c-axis, is one of promising thermoelectric oxides. The most impressive feature of Bi{sub 2}AE{sub 2}Co{sub 2}O{sub 8+δ}, as reported previously, is their electrical conductivity mainly lying along CoO{sub 2} plane, adjusting Bi{sub 2}AE{sub 2}O{sub 4} layer simultaneously manipulates both thermal conductivity and electrical conductivity. It in turn optimizes thermoelectric performance of these materials. In this work, we characterize the anisotropic thermal and electrical conductivity along both ab-plane and c-direction of Bi{sub 2}AE{sub 2}Co{sub 2}O{sub 8+δ} (AE = Ca, Sr, Ba, Sr{sub 1−x}Ba{sub x}) single crystals. The results substantiate that isovalence replacement in Bi{sub 2}AE{sub 2}Co{sub 2}O{sub 8+δ} remarkably modifies their electrical property along ab-plane; while their thermal conductivity along ab-plane only has a slightly difference. At the same time, both the electrical conductivity and thermal conductivity along c-axis of these materials also have dramatic changes. Certainly, the electrical resistance along c-axis is too high to be used as thermoelectric applications. These results suggest that adjusting nano-block Bi{sub 2}AE{sub 2}O{sub 4} layer in Bi{sub 2}AE{sub 2}Co{sub 2}O{sub 8+δ} cannot modify the thermal conductivity along high electrical conductivity plane (ab-plane here). The evolution of electrical property is discussed by Anderson localization and electron-electron interaction U. And the modification of thermal conductivity along c-axis is attributed to the microstructure difference. This work sheds more light on the manipulation of the thermal and electrical conductivity in the layered thermoelectric materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Future evolution of virtual water trading in the United States electricity sector

Abstract Future transformations in the electricity sector could entail major shifts in power sector technology mixes and electricity trade, with consequences for the trading of virtual water. Previous virtual water trade studies largely focus on historical timeframes. We explore, for the first time, future—through 2050—virtual water trade driven by electricity trade under a range of future electricity sector transformation scenarios using the United States as an example. Under a business-as-usual scenario, virtual water trading in 2050 decreases by 3% relative to 2015 levels. By contrast, virtual water trading increases respectively by 3%, 26%, and 32%, in scenarios characterized by higher socioeconomic growth, higher potential for transmission expansion, and low-carbon transitions. These increases are driven by electricity generation expansion in the western U.S., resulting in higher virtual water trade to the east. In addition, we find that as electricity generation shifts west, an increased amount of nonrenewable groundwater will be consumed to generate electricity that is supplied to the east. Independent of scenario, the US electricity grid largely relies on virtual water exports from only a few states. Our study highlights the need for integrated and national strategies to manage the water and electric systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Development of a 200-kW Turbo-Electric Distributed Propulsion Testbed

The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) (Edwards, California) is developing a Hybrid-Electric Integrated Systems Testbed (HEIST) Testbed as part of the HEIST Project, to study power management and transition complexities, modular architectures, and flight control laws for turbo-electric distributed propulsion technologies using representative hardware and piloted simulations. Capabilities are being developed to assess the flight readiness of hybrid electric and distributed electric vehicle architectures. Additionally, NASA will leverage experience gained and assets developed from HEIST to assist in flight-test proposal development, flight-test vehicle design, and evaluation of hybrid electric and distributed electric concept vehicles for flight safety. The HEIST test equipment will include three trailers supporting a distributed electric propulsion wing, a battery system and turbogenerator, dynamometers, and supporting power and communication infrastructure, all connected to the AFRC Core simulation. Plans call for 18 high performance electric motors that will be powered by batteries and the turbogenerator, and commanded by a piloted simulation. Flight control algorithms will be developed on the turbo-electric distributed propulsion system.

distributed↗

A Review of Distributed Electric Propulsion Concepts for Air Vehicle Technology

The emergence of distributed electric propulsion (DEP) concepts for aircraft systems has enabled new capabilities in the overall efficiency, capabilities, and robustness of future air vehicles. Distributed electric propulsion systems feature the novel approach of utilizing electrically-driven propulsors which are only connected electrically to energy sources or power-generating devices. As a result, propulsors can be placed, sized, and operated with greater flexibility to leverage the synergistic benefits of aero-propulsive coupling and provide improved performance over more traditional designs. A number of conventional aircraft concepts that utilize distributed electric propulsion have been developed, along with various short and vertical takeoff and landing platforms. Careful integration of electrically-driven propulsors for boundary-layer ingestion can allow for improved propulsive efficiency and wake-filling benefits. The placement and configuration of propulsors can also be used to mitigate the trailing vortex system of a lifting surface or leverage increases in dynamic pressure across blown surfaces for increased lift performance. Additionally, the thrust stream of distributed electric propulsors can be utilized to enable new capabilities in vehicle control, including reducing requirements for traditional control surfaces and increasing tolerance of the vehicle control system to engine-out or propulsor-out scenarios. If one or more turboelectric generators and multiple electric fans are used, the increased effective bypass ratio of the whole propulsion system can also enable lower community noise during takeoff and landing segments of flight and higher propulsive efficiency at all conditions. Furthermore, the small propulsors of a DEP system can be installed to leverage an acoustic shielding effect by the airframe, which can further reduce noise signatures. The rapid growth in flight-weight electrical systems and power architectures has provided new enabling technologies for future DEP concepts, which provide flexible operational capabilities far beyond those of current systems. While a number of integration challenges exist, DEP is a disruptive concept that can lead to unprecedented improvements in future aircraft designs.

electric propulsion↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

electrified↗