Search NASA⌕ Search

SEARCH · Search NASA

Results for “enhanced sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Small Particulate Contamination Survey Of Genesis Flight Sample 61423

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Tribological and Radiation Shielding Response of Novel Titanium-Boron Nitride Coatings for Lunar Structural Components

Aluminum (Al) and titanium (Ti) lightweight alloys play a crucial role in space systems due to their exceptional strength-to-weight ratio. However, their premature failure in the presence of lunar regolith and their lack of neutron shielding ability are significant challenges. To address these issues, we have developed air and vacuum plasma-sprayed hBN (hexagonal Boron Nitride) -reinforced titanium coatings with 2 and 10 vol% of hBN. Tribological studies conducted with JSC-1 A lunar regolith simulant revealed a 90 % reduction in wear volume for the Ti/2 vol% hBN coatings compared to conventional materials due to the synergistic action of harder secondary phases and solid lubrication effect of hBN. Additionally, a 27 % enhancement in radiation shielding is obtained based on the mass absorption coefficient (radiation absorbed per sample density and thickness) for VPS Ti/2 vol% hBN coatings.

Wear↗

EDEN: Exploring Disks Embedded in N-body Simulations of Milky Way–mass Halos from Symphony

We investigate the impact of galactic disks on the tidal stripping of cold dark matter subhalos within Milky Way (MW)-mass halos (M vir ∼ 10 12 M ⊙ ) using a new simulation suite, EDEN. By re-simulating 45 MW-mass zoomed-in halos from the N-body Symphony compilation with embedded disk potentials, which evolve according to star formation histories predicted by the UniverseMachine model, we self-consistently tie disk growth to halo accretion rate and significantly expand the range of disk masses and formation histories studied. We use the particle-tracking-based subhalo finder Symfind to enhance the robustness of subhalo tracking. We find that disks near the median disk-to-halo mass ratio of our sample (M *,Disk /M vir,host = 2%) reduce subhalo peak mass functions within 100 kpc by about 10% for peak masses above 10 8 M ⊙ . Heavier, MW/M31-like disks (M *,Disk /M vir,host ≳ 5%) lead to a reduction of more than 40%. Subhalo abundance suppression is more pronounced near halo centers, with particularly enhanced stripping for subhalos accreted over 8 Gyr ago on orbits with pericenters <100 kpc. Suppression is further amplified when disk mass is increased within fixed halo and disk assembly histories. In all cases, the suppression we measure should be interpreted as stripping below the mass resolution limit rather than complete subhalo disruption. This study reshapes our understanding of the MW’s impact on its satellites, suggesting it strips subhalos more efficiently than typical MW-mass galaxies due to its larger disk-to-halo mass ratio and earlier disk formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigations of radiation-induced and carrier-enhanced conductivity

A steady-state carrier computer code, PECK (Parker Enhanced Carrier Kinetics), that predicts the radiation-induced conductivity (RIC) produced in a dielectric by an electron beam was developed. The model, which assumes instantly-trapped holes, was then applied to experimental measurements on thin Kapton samples penetrated by an electron beam. Measurements at high bias were matched in the model by an appropriate choice for the trap-modulated electron mobility. A fractional split between front and rear currents measured at zone bias is explained on the basis of beam-scattering. The effects of carrier-enhanced conductivity (CEC) on data obtained for thick, free-surface Kapton samples is described by using an analytical model that incorporates field injection of carriers from the RIC region. The computer code, LWPCHARGE, modified for carrier transport, is also used to predict partial penetration effects associated with CEC in the unirradiated region. Experimental currents and surface voltages, when incorporated in the appropriate models, provide a value for the trap modulated mobility that is in essential agreement with the RIC results.

Meulenberg, A., Jr.↗

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Coordinated Analysis of Phosphates in Samples From Asteroid (101955) Bennu

Asteroid (101955) Bennu is a B-type asteroid and a prime candidate for investigating the remnants of planet formation and enhancing our understanding of potential sources of crucial bio-essential elements for the early Earth. Remote observations of the surface of Bennu unveiled a terrain of boulders primarily composed of hydrated phyllosilicates, organic molecules, and carbonates. The hydrated nature of Bennu, the abundance of carbonates, and the presence of cm-scale carbonate veins provide clues to the nature of the building blocks of Bennu’s parent body and to its complex geological history. Here we present the first mineralogical, chemical, and isotopic results of analysis of phosphates in samples returned from Bennu by NASA’s OSIRIS-REx mission. We seek to test the hypothesis that heating of Bennu’s parent asteroid resulted in hydrothermal alteration in which melted ice reacted with the initial constituents.

J. J. Barnes↗

Enhancing Sensitivity in Targeted Single-Cell Proteomics by Coupling a Dual Ion Funnel Interface with Triple Quadrupole Mass Spectrometer

Single-cell proteomics (SCP) has emerged as a powerful approach for understanding cellular heterogeneity and biological processes at unprecedented resolution. However, the extremely limited protein content of individual cells (femtogram to picogram levels) pushes current mass spectrometry instrumentation to its sensitivity limits, creating a critical analytical bottleneck. While selected reaction monitoring (SRM) using triple quadrupole (QqQ) instruments 1 offers advantages in sensitivity and reproducibility for targeted proteomics quantification, SRM still struggles with sensitivity for quantification of moderate- or low-abundance proteins from single-cell sample amounts. Here, we report the development and systematic evaluation of a dual ion funnel interface designed to address the sensitivity limitation by significantly enhancing ion transmission efficiency in commercial QqQ mass spectrometers. The dual ion funnel interface, composed of a curved S-funnel followed by a conventional ion funnel, improves ion transmission efficiency while reducing chemical noise through selective ion focusing. The performance of the dual ion funnel interface was systematically compared to standard interface on a TSQ Vantage platform across samples with different levels of complexity. The dual funnel interface demonstrated to provide up to 25-fold improvement in sensitivity across a wide range of protein concentrations in different biological matrices (low complex mouse macrophage and high complex human cells). Critically, enhanced sensitivity was accompanied by increased analytical reproducibility with lower coefficient of variations. Most importantly, the dual funnel interface enabled reliable quantification of low-abundance proteins that were barely detectable or not detected by the standard interface, extending analysis to single-cell equivalent amounts while maintaining excellent reproducibility. These results demonstrate that the dual funnel interface addresses the critical bottleneck in quantitative targeted proteomics, providing a technological foundation for ultrasensitive targeted SCP that requires both high sensitivity and robust quantitative performance.

Min, Sehong↗

CARA Status and Upcoming Enhancements

CAS 8.4.3 was deployed to operations on 13 June 2017. Discrepancies Between 3D Pc Estimates and advanced Monte Carlo Equinoctial-Sampling Pc Estimates discovered and discussed at 23 May 2017 Useras (Registered Trademark) Forum. The patch created the Reporting Pc, which is the greater value between the calculated 2D and 3D Pc values This changed the Pc reported in the CDMs to the Reporting Pc This changed the Pc reported on the Summary Report to the Reporting Pc This changed the Pc reported on Maneuver Screening Analysis (MSA) Report to the Reporting Pc. Both the 2D and 3D Pc added to the Summary Report details section The patch also updated the 3D Pc algorithm to eliminate velocity covariance from the Pc calculation This will bring 2D and 3D Pc into close alignment for vast majority of events, particularly for the events in which the 2D/3D discrepancy was found.

conjunction assessmen↗

The role of the Remotely Augmented Vehicle (RAV) laboratory in flight research

An overview is presented of the unique capabilities and historical significance of the Remotely Augmented Vehicle (RAV) Lab at NASA-Dryden. The role is reviewed of the RAV Lab in enhancing flight test programs and efficient testing of new aircraft control laws. The history of the RAV Lab is discussed with a sample of its application using the X-29 aircraft. The RAV Lab allows for closed or open loop augmentation of the research aircraft while in flight using ground based, high performance real time computers. Telemetry systems transfer sensor and control data between the ground and the aircraft. The RAV capability provides for enhanced computational power, improved flight data quality, and alternate methods for the testing of control system concepts. The Lab is easily reconfigured to reflect changes within a flight program and can be adapted to new flight programs.

Cohen, Dorothea↗

Resolution-enhanced Mapping Spectrometer

A familiar mapping spectrometer implementation utilizes two dimensional detector arrays with spectral dispersion along one direction and spatial along the other. Spectral images are formed by spatially scanning across the scene (i.e., push-broom scanning). For imaging grating and prism spectrometers, the slit is perpendicular to the spatial scan direction. For spectrometers utilizing linearly variable focal-plane-mounted filters the spatial scan direction is perpendicular to the direction of spectral variation. These spectrometers share the common limitation that the number of spectral resolution elements is given by the number of pixels along the spectral (or dispersive) direction. Resolution enhancement by first passing the light input to the spectrometer through a scanned etalon or Michelson is discussed. Thus, while a detector element is scanned through a spatial resolution element of the scene, it is also temporally sampled. The analysis for all the pixels in the dispersive direction is addressed. Several specific examples are discussed. The alternate use of a Michelson for the same enhancement purpose is also discussed. Suitable for weight constrained deep space missions, hardware systems were developed including actuators, sensor, and electronics such that low-resolution etalons with performance required for implementation would weigh less than one pound.

Kumer, J. B.↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Airborne Allergen Levels Before and After Rain Events Using TRMM/GPM and Ground-Sampled Data

Allergies affect millions of Americans, increasing health risks and also increasing absenteeism and reducing productivity in the workplace. Outdoor allergens, such as airborne pollens and mold spores, commonly trigger respiratory distress symptoms, but rainfall reduces the quantity of allergens in the air (EPA, 2003). The current NASA Tropical Rainfall Measuring Mission provides accurate information related to rain events. These capabilities will be further enhanced with the future Global Precipitation Measurement mission. This report examines the effectiveness of combining these NASA resources with established ground-based allergen/spore sampling systems to better understand the benefits that rain provides in removing allergens and spores from the air.

Stewart, Randy M.↗

The role of the remotely augmented vehicle (RAV) laboratory in flight research

This paper presents on overview of the unique capabilities and historical significance of the Remotely Augmented Vehicle (RAV) Laboratory at the NASA Dryden Flight Research Facility. The report reviews the role of the RAV Laboratory in enhancing flight test programs and efficient testing of new aircraft control laws. The history of the RAV Laboratory is discussed with a sample of its application using the X-29 aircraft. The RAV Laboratory allows for closed- or open-loop augmentation of the research aircraft while in flight using ground-based, high performance real-time computers. Telemetry systems transfer sensor and control data between the ground and the aircraft. The RAV capability provides for enhanced computational power, improved flight data quality, and alternate methods for the testing of control system concepts. The Laboratory is easily reconfigured to reflect changes within a flight program and can be adapted to new flight programs.

Cohen, Dorothea↗

Dumb-bell galaxies in southern clusters: Catalog and preliminary statistical results

The dominant galaxy of a rich cluster is often an object whose formation and evolution is closely connected to the dynamics of the cluster itself. Hoessel (1980) and Schneider et al. (1983) estimate that 50 percent of the dominant galaxies are either of the dumb-bell type or have companions at projected distances less than 20 kpc, which is far in excess of the number expected from chance projection (see also Rood and Leir 1979). Presently there is no complete sample of these objects, with the exception of the listing of dumb-bell galaxies in BM type I and I-II clusters in the Abell statistical sample of Rood and Leir (1979). Recent dynamical studies of dumb-bell galaxies in clusters (Valentijn and Casertano, 1988) still suffer from inhomogeneity of the sample. The fact that it is a mixture of optically and radio selected objects may have introduced an unknown biases, for instance if the probability of radio emission is enhanced by the presence of close companions (Stocke, 1978, Heckman et al. 1985, Vettolani and Gregorini 1988) a bias could be present in their velocity distribution. However, this situation is bound to improve: a new sample of Abell clusters in the Southern Hemisphere has been constructed (Abell et al., 1988 hereafter ACO), which has several advantages over the original northern catalog. The plate material (IIIaJ plates) is of better quality and reaches fainter magnitudes. This makes it possible to classify the cluster types with a higher degree of accuracy, as well as to fainter magnitudes. The authors therefore decided to reconsider the whole problem constructing a new sample of dumb-bell galaxies homogeneously selected from the ACO survey. Details of the classification criteria are given.

Vettolani, G.↗

Reverse martensitic transformation on the corrosion behavior of a 2304 lean duplex stainless steel

This study investigates the influence of the reverse martensitic transformation on the corrosion behavior of 2304 lean duplex stainless steel (LDSS) at low temperatures (400–600°C). The steel underwent cold rolling, followed by isochronal annealing for 0.5 h. Phase transformations and microstructures were analyzed using X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Corrosion resistance was evaluated using a syringe cell with cyclic potentiodynamic polarization in 0.6 M NaCl solution and double-loop electrochemical potentiokinetic reactivation in 0.5 M H 2 SO 4 + 0.001 M KSCN solution. A bimodal breakdown potential behavior, associated with either pitting or transpassivity, was observed in the as-received (AR) and samples annealed at 400°C. Pitting in the AR sample was associated with Al–Mg–Si–Ca–O inclusions, while pitting on the samples annealed at 400°C was linked to local reduced passive film resistance. Severe cold rolling enhanced the pitting resistance of 2304 LDSS. Selective electrochemical etching revealed preferential corrosion at phase interfaces and within the austenite phase. Additionally, annealing at 500°C to 600°C led to a marked decrease in pitting resistance and increased sensitization. Electron backscatter diffraction analysis of the corroded pits in the annealed specimens indicated that pits tend to nucleate and grow in α'-martensite/austenite regions. Furthermore, the nanostructure formed during low-temperature reversion, characterized by dislocation-cell martensite with high dislocation density and stacking faults, may adversely affect corrosion resistance due to heterogeneities associated with alloying element redistribution.

36 MATERIALS SCIENCE↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗