Search NASA⌕ Search

SEARCH · Search NASA

Results for “error impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Clinical Experience and Evaluation of Patient Treatment Verification With a Transit Dosimeter

Purpose: To prospectively evaluate a protocol for transit dosimetry on a patient population undergoing intensity modulated radiation therapy (IMRT) and to assess the issues in clinical implementation of electronic portal imaging devices (EPIDs) for treatment verification. Methods and Materials: Fifty-eight patients were enrolled in the study. Amorphous silicon EPIDs were calibrated for dose and used to acquire images of delivered fields. Measured EPID dose maps were back-projected using the planning computed tomographic (CT) images to calculate dose at prespecified points within the patient and compared with treatment planning system dose offline using point dose difference and point γ analysis. The deviation of the results was used to inform future action levels. Results: Two hundred twenty-five transit images were analyzed, composed of breast, prostate, and head and neck IMRT fields. Patient measurements demonstrated the potential of the dose verification protocol to model dose well under complex conditions: 83.8% of all delivered beams achieved the initial set tolerance level of Δ{sub D} of 0 ± 5 cGy or %Δ{sub D} of 0% ± 5%. Importantly, the protocol was also sensitive to anatomic changes and spotted that 3 patients from 20 measured prostate patients had undergone anatomic change in comparison with the planning CT. Patient data suggested an EPID-reconstructed versus treatment planning system dose difference action level of 0% ± 7% for breast fields. Asymmetric action levels were more appropriate for inversed IMRT fields, using absolute dose difference (−2 ± 5 cGy) or summed field percentage dose difference (−6% ± 7%). Conclusions: The in vivo dose verification method was easy to use and simple to implement, and it could detect patient anatomic changes that impacted dose delivery. The system required no extra dose to the patient or treatment time delay and so could be used throughout the course of treatment to identify and limit systematic and random errors in dose delivery for patient groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constraining neutrino properties with a Euclid-like galaxy cluster survey

We perform a forecast analysis on how well a Euclid-like photometric galaxy cluster survey will constrain the total neutrino mass and effective number of neutrino species. We base our analysis on the Monte Carlo Markov Chains technique by combining information from cluster number counts and cluster power spectrum. We find that combining cluster data with Cosmic Microwave Background (CMB) measurements from Planck improves by more than an order of magnitude the constraint on neutrino masses compared to each probe used independently. For the ΛCDM+m{sub ν} model the 2σ upper limit on total neutrino mass shifts from Σm{sub ν} < 0.35 eV using cluster data alone to Σm{sub ν} < 0.031 eV when combined with Planck data. When a non-standard scenario with N{sub eff}≠3.046 number of neutrino species is considered, we estimate an upper limit of N{sub eff} < 3.14 (95%CL), while the bounds on neutrino mass are relaxed to Σm{sub ν} < 0.040 eV. This accuracy would be sufficient for a 2σ detection of neutrino mass even in the minimal normal hierarchy scenario (Σm{sub ν} ≅ 0.05 eV). In addition to the extended ΛCDM+m{sub ν}+N{sub eff} model we also consider scenarios with a constant dark energy equation of state and a non-vanishing curvature. When these models are considered the error on Σm{sub ν} is only slightly affected, while there is a larger impact of the order of ∼ 15% and ∼ 20% respectively on the 2σ error bar of N{sub eff} with respect to the standard case. To assess the effect of an uncertain knowledge of the relation between cluster mass and optical richness, we also treat the ΛCDM+m{sub ν}+N{sub eff} case with free nuisance parameters, which parameterize the uncertainties on the cluster mass determination. Adopting the over-conservative assumption of no prior knowledge on the nuisance parameter the loss of information from cluster number counts leads to a large degradation of neutrino constraints. In particular, the upper bounds for Σm{sub ν} are relaxed by a factor larger than two, Σm{sub ν} < 0.083 eV (95%CL), hence compromising the possibility of detecting the total neutrino mass with good significance. We thus confirm the potential that a large optical/near-IR cluster survey, like that to be carried out by Euclid, could have in constraining neutrino properties, and we stress the importance of a robust measurement of masses, e.g. from weak lensing within the Euclid survey, in order to full exploit the cosmological information carried by such survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Tumor-Volume Simulation During Radiotherapy for Head-and-Neck Cancer Using a Four-Level Cell Population Model

Purpose: To develop a fast computational radiobiologic model for quantitative analysis of tumor volume during fractionated radiotherapy. The tumor-volume model can be useful for optimizing image-guidance protocols and four-dimensional treatment simulations in proton therapy that is highly sensitive to physiologic changes. Methods: The analysis is performed using two approximations: (1) tumor volume is a linear function of total cell number and (2) tumor-cell population is separated into four subpopulations: oxygenated viable cells, oxygenated lethally damaged cells, hypoxic viable cells, and hypoxic lethally damaged cells. An exponential decay model is used for disintegration and removal of oxygenated lethally damaged cells from the tumor. Results: We tested our model on daily volumetric imaging data available for 14 head-and-neck cancer patients treated with an integrated computed tomography/linear accelerator system. A simulation based on the averaged values of radiobiologic parameters was able to describe eight cases during the entire treatment and four cases partially (50% of treatment time) with a maximum 20% error. The largest discrepancies between the model and clinical data were obtained for small tumors, which may be explained by larger errors in the manual tumor volume delineation procedure. Conclusions: Our results indicate that the change in gross tumor volume for head-and-neck cancer can be adequately described by a relatively simple radiobiologic model. In future research, we propose to study the variation of model parameters by fitting to clinical data for a cohort of patients with head-and-neck cancer and other tumors. The potential impact of other processes, like concurrent chemotherapy, on tumor volume should be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ON THE NATURE OF SMALL PLANETS AROUND THE COOLEST KEPLER STARS

We constrain the densities of Earth- to Neptune-size planets around very cool (T{sub e} = 3660-4660 K) Kepler stars by comparing 1202 Keck/HIRES radial velocity measurements of 150 nearby stars to a model based on Kepler candidate planet radii and a power-law mass-radius relation. Our analysis is based on the presumption that the planet populations around the two sets of stars are the same. The model can reproduce the observed distribution of radial velocity variation over a range of parameter values, but, for the expected level of Doppler systematic error, the highest Kolmogorov-Smirnov probabilities occur for a power-law index {alpha} Almost-Equal-To 4, indicating that rocky-metal planets dominate the planet population in this size range. A single population of gas-rich, low-density planets with {alpha} = 2 is ruled out unless our Doppler errors are {>=}5 m s{sup -1}, i.e., much larger than expected based on observations and stellar chromospheric emission. If small planets are a mix of {gamma} rocky planets ({alpha} = 3.85) and 1 - {gamma} gas-rich planets ({alpha} = 2), then {gamma} > 0.5 unless Doppler errors are {>=}4 m s{sup -1}. Our comparison also suggests that Kepler's detection efficiency relative to ideal calculations is less than unity. One possible source of incompleteness is target stars that are misclassified subgiants or giants, for which the transits of small planets would be impossible to detect. Our results are robust to systematic effects, and plausible errors in the estimated radii of Kepler stars have only moderate impact.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-C-17A-08: Improving IMRT Planning and Reducing Inter-Planner Variability Using the Stochastic Frontier Method: Validation Based On Clinical and Simulated Data

Purpose: Intensity modulated radiation therapy always requires compromises between PTV coverage and organs at risk (OAR) sparing. We previously developed metrics that correlate doses to OAR to specific patients’ morphology using stochastic frontier analysis (SFA). Here, we aim to examine the validity of this approach using a large set of realistically simulated dosimetric and geometric data. Methods: SFA describes a set of treatment plans as an asymmetric distribution with respect to a frontier defining optimal plans. Eighty head and neck IMRT plans were used to establish a metric predicting the mean dose to parotids as a function of simple geometric parameters. A database of 140 parotids was used as a basis distribution to simulate physically plausible data of geometry and dose. Distributions comprising between 20 and 5000 were simulated and the SFA was applied to obtain new frontiers, which were compared to the original frontier. Results: It was possible to simulate distributions consistent with the original dataset. Below 160 organs, the SFA could not always describe distributions as asymmetric: a few cases showed a Gaussian or half-Gaussian distribution. In order to converge to a stable solution, the number of organs in a distribution must ideally be above 100, but in many cases stable parameters could be achieved with as low as 60 samples of organ data. Mean RMS value of the error of new frontiers was significantly reduced when additional organs are used. Conclusion: The number of organs in a distribution showed to have an impact on the effectiveness of the model. It is always possible to obtain a frontier, but if the number of organs in the distribution is small (< 160), it may not represent de lowest dose achievable. These results will be used to determine number of cases necessary to adapt the model to other organs.

60 APPLIED LIFE SCIENCES↗

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric↗

Ultra-deep mutant spectrum profiling: improving sequencing accuracy using overlapping read pairs

Backgound: High throughput sequencing is beginning to make a transformative impact in the area of viral evolution. Deep sequencing has the potential to reveal the mutant spectrum within a viral sample at high resolution, thus enabling the close examination of viral mutational dynamics both within- and between-hosts. The challenge however, is to accurately model the errors in the sequencing data and differentiate real viral mutations, particularly those that exist at low frequencies, from sequencing errors. Results: We demonstrate that overlapping read pairs (ORP) -- generated by combining short fragment sequencing libraries and longer sequencing reads -- significantly reduce sequencing error rates and improve rare variant detection accuracy. Using this sequencing protocol and an error model optimized for variant detection, we are able to capture a large number of genetic mutations present within a viral population at ultra-low frequency levels (<0.05%). Conclusions: Our rare variant detection strategies have important implications beyond viral evolution and can be applied to any basic and clinical research area that requires the identification of rare mutations.

59 BASIC BIOLOGICAL SCIENCES↗

Binning is Sinning (Supernova Version): The Impact of Self-calibration in Cosmological Analyses with Type Ia Supernovae

Recent cosmological analyses (e.g., JLA, Pantheon) of Type Ia supernovae (SNe Ia) have propagated systematic uncertainties into a covariance matrix and either binned or smoothed the systematic uncertainty vectors in redshift space. We demonstrate that systematic error budgets of these analyses can be improved by a factor of ~ 1.5 × with the use of unbinned and unsmoothed covariance matrices. To understand this, we employ a separate approach that simultaneously fits for cosmological parameters and additional self-calibrating scale parameters that constrain the size of each systematic. We show that the covariance-matrix approach and scale-parameter approach indeed yield equivalent results, implying that in both cases the data can self-calibrate certain systematic uncertainties, but that this ability is hindered when information is binned or smoothed in redshift space. We review the top systematic uncertainties in current analyses and find that the reduction of systematic uncertainties in the unbinned case depends on whether a systematic is solely degenerate with the cosmological model in redshift space or whether it can be described by additional correlations between supernova properties and luminosity. Furthermore, we show that the power of self-calibration increases with the size of the data set, which presents a tremendous opportunity for upcoming analyses of photometrically classified samples, like those of Legacy Survey of Space and Time (LSST) and the Nancy Grace Roman Telescope (NGRST). However, to take advantage of self-calibration in large, photometrically classified samples, we must first address the issue that binning is required in currently used photometric analysis methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics-based hybrid machine learning for critical heat flux prediction with uncertainty quantification

Critical heat flux (CHF) is a key quantity in nuclear system modeling due to its impact on heat transfer, safety margins, and reactor performance. This study develops and validates an uncertainty-aware hybrid modeling approach that combines machine learning with physics-based models to predict CHF in cases of dryout. The Biasi and Bowring empirical correlations were paired with three ML uncertainty quantification (UQ) techniques: deep neural network (DNN) ensembles, Bayesian neural networks (BNNs), and deep Gaussian processes (DGPs). A pure ML model without a base model was evaluated for comparison. Model performance was assessed under plentiful (7,350 points) and limited (9 points) training data scenarios using parity, uncertainty distributions, and calibration curves. Results show that the Biasi hybrid DNN ensemble achieved the best overall performance, with a mean absolute relative error of 1.846%, and well-calibrated uncertainty estimates. The BNN-based hybrids showed slightly higher error (2.14%) but superior uncertainty calibration. DGP models underperformed, with over 6% error and poor uncertainty calibration. All hybrid models outperformed pure machine learning configurations, demonstrating resistance against data scarcity. These findings indicate that hybrid modeling significantly improves predictive accuracy, interpretability, and resilience to data scarcity. The integration of uncertainty awareness provides actionable confidence in CHF predictions, which is vital for safety-critical decisions in nuclear applications. This hybrid approach offers a viable pathway for deploying ML models in reactor analysis tools while preserving domain knowledge and physical consistency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mass Properties Testing and Evaluation for the Multi-Mission Radioisotope Thermoelectric Generator

Mass properties (MP) measurements were performed for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG), serial number (S/N) 0X730401, the power system designated for the Mars Science Laboratory (MSL) mission. Measurements were made using new mounting fixtures at the mass properties testing station in the Idaho National Laboratory (INL) Space and Security Power Systems Facility (SSPSF). The objective of making mass properties measurements was to determine the generator’s flight configured mass and center of mass or center of gravity (CG). Using an extremely accurate platform scale, the mass of the as-tested generator was determined to be 100.117 ± 0.007 lb. Weight accuracy was determined by checking the platform scale with calibrated weights immediately prior to weighing the MMRTG.a CG measurement accuracy was assessed by surrogate testing using an inert mass standard for which the CG could be readily determined analytically. Repeated testing using the mass standard enabled the basic measurement precision of the system to be quantified in terms of a physical confidence interval about the measured CG position. However, repetitious testing with the MMRTG itself was not performed in deference to the gamma and neutron radiation dose to operators and the damage potential to the flight unit from extra handling operations. Since the mass standard had been specially designed to have a total weight and CG location that closely matched the MMRTG, the uncertainties determined from its testing were assigned to the MMRTG as well. On this basis, and at the 99% confidence level, a statistical analysis found the direct, as-measured MMRTG-MSL CG to be located at 10.816 ± 0.0011 in. measured perpendicular from the plane of the lower surface of the generator’s mounting lugs (Z direction), and offset from the generator’s long axis centerline in the X and Y directions by 0.0968 ± 0.0040 in. and 0.0276 ± 0.0026 in., respectively. These uncertainties are based simply on the statistical treatment of results from repetitive testing performed with the mass standard and included position variations that may have occurred during several mounting/dismounting operations of both the mass standard and mounting fixtures. Because of the limited data available, the computed uncertainty intervals reported are likely, although not assuredly, wider than the intervals that would have been found had more extensive data been available. However, these uncertainties do not account for other contributors to measurement uncertainty that might be applicable. These include potential weighing errors, possible tilt of the as-mounted test article, or translation of the measurement results from the MP instrument coordinates to those of the test article. Furthermore, when testing heat producing test articles such as the MMRTG, measurement degradation can occur from thermal expansion/contraction of the mounting fixtures as they heat up or cool and cause a subtle repositioning of the test article. Analyses for such impacts were made and additional uncertainty allowances were conservatively assigned to account for these. A full, detailed description is provided in this report.

30 DIRECT ENERGY CONVERSION↗

Impact of point spread function higher moments error on weak gravitational lensing – II. A comprehensive study

ABSTRACT Weak lensing is one of the most powerful probes for dark matter and dark energy science, although it faces increasing challenges in controlling systematic uncertainties as the statistical errors become smaller. The point spread function (PSF) needs to be precisely modeled to avoid systematic error on the weak lensing measurements. The weak lensing biases induced by errors in the PSF model second moments, i.e. its size and shape, are well-studied. However, Zhang et al. showed that errors in the higher moments of the PSF may also be a significant source of systematics for upcoming weak lensing surveys. Therefore, this work comprehensively investigate the modelling quality of PSF moments from the 3rd to 6th order, and propagate the PSFEx higher moments modelling error in the HSC survey data set to the weak lensing shear–shear correlation functions and their cosmological analyses. The overall multiplicative shear bias associated with errors in PSF higher moments can cause an ∼0.1σ shift on the cosmological parameters for LSST Y10, while the associated additive biases can induce 1σ uncertainties in cosmology parameter inference for LSST Y10, if not accounted. We compare the PSFEx model with PSF in Full FOV, and find similar performance in modelling the PSF higher moments. We conclude that PSF higher moment errors of the future PSF models should be reduced from those in current methods, otherwise needed to be explicitly modeled in the weak lensing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

The DESI N -body simulation project – I. Testing the robustness of simulations for the DESI dark time survey

ABSTRACT Analysis of large galaxy surveys requires confidence in the robustness of numerical simulation methods. The simulations are used to construct mock galaxy catalogues to validate data analysis pipelines and identify potential systematics. We compare three N-body simulation codes, abacus, gadget-2, and swift, to investigate the regimes in which their results agree. We run N-body simulations at three different mass resolutions, 6.25 × 108, 2.11 × 109, and 5.00 × 109 h−1 M⊙, matching phases to reduce the noise within the comparisons. We find systematic errors in the halo clustering between different codes are smaller than the Dark Energy Spectroscopic Instrument (DESI) statistical error for $s\ \gt\ 20\ h^{-1}$ Mpc in the correlation function in redshift space. Through the resolution comparison we find that simulations run with a mass resolution of 2.1 × 109 h−1 M⊙ are sufficiently converged for systematic effects in the halo clustering to be smaller than the DESI statistical error at scales larger than $20\ h^{-1}$ Mpc. These findings show that the simulations are robust for extracting cosmological information from large scales which is the key goal of the DESI survey. Comparing matter power spectra, we find the codes agree to within 1 per cent for k ≤ 10 h Mpc−1. We also run a comparison of three initial condition generation codes and find good agreement. In addition, we include a quasi-N-body code, FastPM, since we plan use it for certain DESI analyses. The impact of the halo definition and galaxy–halo relation will be presented in a follow-up study.

79 ASTRONOMY AND ASTROPHYSICS↗

A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation

Purpose: To evaluate the accuracy and robustness of a simple, linear, separable, two-parameter model (basis vector model, BVM) in mapping proton stopping powers via dual energy computed tomography (DECT) imaging. Methods: The BVM assumes that photon cross sections (attenuation coefficients) of unknown materials are linear combinations of the corresponding radiological quantities of dissimilar basis substances (i.e., polystyrene, CaCl{sub 2} aqueous solution, and water). The authors have extended this approach to the estimation of electron density and mean excitation energy, which are required parameters for computing proton stopping powers via the Bethe–Bloch equation. The authors compared the stopping power estimation accuracy of the BVM with that of a nonlinear, nonseparable photon cross section Torikoshi parametric fit model (VCU tPFM) as implemented by the authors and by Yang et al. [“Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues,” Phys. Med. Biol. 55, 1343–1362 (2010)]. Using an idealized monoenergetic DECT imaging model, proton ranges estimated by the BVM, VCU tPFM, and Yang tPFM were compared to International Commission on Radiation Units and Measurements (ICRU) published reference values. The robustness of the stopping power prediction accuracy of tissue composition variations was assessed for both of the BVM and VCU tPFM. The sensitivity of accuracy to CT image uncertainty was also evaluated. Results: Based on the authors’ idealized, error-free DECT imaging model, the root-mean-square error of BVM proton stopping power estimation for 175 MeV protons relative to ICRU reference values for 34 ICRU standard tissues is 0.20%, compared to 0.23% and 0.68% for the Yang and VCU tPFM models, respectively. The range estimation errors were less than 1 mm for the BVM and Yang tPFM models, respectively. The BVM estimation accuracy is not dependent on tissue type and proton energy range. The BVM is slightly more vulnerable to CT image intensity uncertainties than the tPFM models. Both the BVM and tPFM prediction accuracies were robust to uncertainties of tissue composition and independent of the choice of reference values. This reported accuracy does not include the impacts of I-value uncertainties and imaging artifacts and may not be achievable on current clinical CT scanners. Conclusions: The proton stopping power estimation accuracy of the proposed linear, separable BVM model is comparable to or better than that of the nonseparable tPFM models proposed by other groups. In contrast to the tPFM, the BVM does not require an iterative solving for effective atomic number and electron density at every voxel; this improves the computational efficiency of DECT imaging when iterative, model-based image reconstruction algorithms are used to minimize noise and systematic imaging artifacts of CT images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fringing Analysis and Simulation for the Vera C. Rubin Observatory’s Legacy Survey of Space and Time

Abstract The presence of fringing in astronomical Charge-Coupled Device (CCD) images will have an impact on photometric quality and measurements. Yet its impact on the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) has not been fully studied. We present a detailed study on fringing for CCDs already implemented on the Rubin Observatory LSST Camera’s focal plane. After making physical measurements and knowing the compositions, we developed a model for the e2v CCDs. We present a method to fit for the internal height variation of the epoxy layer within the sensors based on fringing measurements in a laboratory setting. This method is generic enough that it can be easily modified to work for other CCDs. Using the derived fringing model, we successfully reproduce comparable fringing amplitudes that match the observed levels in images taken by existing telescopes with different optical designs. This model is then used to forecast the expected level of fringing in a single LSST y -band sky background exposure with Rubin telescope optics in the presence of a realistic time-varying sky spectrum. The predicted fringing amplitude in LSST images ranges from 0.04% to 0.2% depending on the location of a CCD on the focal plane. We find that the predicted variation in surface brightness caused by fringing in LSST y -band sky background images is about 0.6 μ Jy arcsec − 2 , which is 40 times larger than the current measurement error. We conclude that it is necessary to include fringing correction in the Rubin’s LSST image processing pipeline.

Astronomy & Astrophysics↗

Neutrino constraints: what large-scale structure and CMB data are telling us?

We discuss the reliability of neutrino mass constraints, either active or sterile, from the combination of different low redshift Universe probes with measurements of CMB anisotropies. In our analyses we consider WMAP 9-year or Planck Cosmic Microwave Background (CMB) data in combination with Baryonic Acoustic Oscillations (BAO) measurements from BOSS DR11, galaxy shear measurements from CFHTLenS, SDSS Ly α forest constraints and galaxy cluster mass function from Chandra observations. At odds with recent similar studies, to avoid model dependence of the constraints we perform a full likelihood analysis for all the datasets employed. As for the cluster data analysis we rely on to the most recent calibration of massive neutrino effects in the halo mass function and we explore the impact of the uncertainty in the mass bias and re-calibration of the halo mass function due to baryonic feedback processes on cosmological parameters. We find that none of the low redshift probes alone provide evidence for massive neutrino in combination with CMB measurements, while a larger than 2σ detection of non zero neutrino mass, either active or sterile, is achieved combining cluster or shear data with CMB and BAO measurements. Yet, the significance of the detection exceeds 3σ if we combine all four datasets. For a three active neutrino scenario, from the joint analysis of CMB, BAO, shear and cluster data including the uncertainty in the mass bias we obtain ∑ m{sub ν} =0.29{sup +0.18}{sub -0.21} eV and ∑ m{sub ν} =0.22{sup +0.17}{sub -0.18} eV 95%CL) using WMAP9 or Planck as CMB dataset, respectively. The preference for massive neutrino is even larger in the sterile neutrino scenario, for which we get m{sub s}{sup eff}=0.44{sup +0.28}{sub -0.26} eV and Δ N{sub eff}=0.78{sup +0.60}{sub -0.59} 95%CL) from the joint analysis of Planck, BAO, shear and cluster datasets. For this data combination the vanilla ΛCDM model is rejected at more than 3σ and a sterile neutrino mass as motivated by accelerator anomaly is within the 2σ errors. Conversely, the Ly α data favour vanishing neutrino masses and from the data combination Planck+BAO+Ly α we get the tight upper limits ∑ m{sub ν} <0.14 eV and m{sub s}{sup eff}<0.22 eV—Δ N{sub eff}<1.11 95%CL) for the active and sterile neutrino model, respectively. Finally, results from the full data combination reflect the tension between the σ{sub 8} constraints obtained from cluster and shear data and that inferred from Ly α forest measurements; in the active neutrino scenario for both CMB datasets employed, the full data combination yields only an upper limits on ∑ m{sub ν}, while assuming an extra sterile neutrino we still get preference for non-vanishing mass, m{sub s}{sup eff}=0.26{sup +0.22}{sub -0.24} eV, and dark contribution to the radiation content, Δ N{sub eff}=0.82±0.55.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing radar scan strategies for tracking isolated deep convection using observing system simulation experiments

Abstract. Optimizing radar observation strategies is one of the most important considerations in pre-field campaign periods. This is especially true for isolated convective clouds that typically evolve faster than the observations captured by operational radar networks. This study investigates uncertainties in radar observations of the evolution of the microphysical and dynamical properties of isolated deep convective clouds developing in clean and polluted environments. It aims to optimize the radar observation strategy for deep convection through the use of high-spatiotemporal cloud-resolving model simulations, which resolve the evolution of individual convective cells every 1 min, coupled with a radar simulator and a cell tracking algorithm. The radar simulation settings are based on the Tracking Aerosol Convection Interactions ExpeRiment (TRACER) and Experiment of Sea Breeze Convection, Aerosols, Precipitation and Environment (ESCAPE) field campaigns held in the Houston, TX, area but are generalizable to other field campaigns focusing on isolated deep convection. Our analysis produces the following four outcomes. First, a 5–7 m s−1 median difference in maximum updrafts of tracked cells is shown between the clean and polluted simulations in the early stages of the cloud lifetimes. This demonstrates the importance of obtaining accurate estimates of vertical velocity from observations if aerosol impacts are to be properly resolved. Second, tracking of individual cells and using vertical cross section scanning every minute capture the evolution of precipitation particle number concentration and size represented by polarimetric observables better than the operational radar observations that update the volume scan every 5 min. This approach also improves multi-Doppler radar updraft retrievals above 5 km above ground level for regions with updraft velocities greater than 10 m s−1. Third, we propose an optimized strategy composed of cell tracking by quick (1–2 min) vertical cross section scans from more than one radar in addition to the operational volume scans. We also propose the use of a single-RHI (range height indicator) updraft retrieval technique for cells close to the radars, for which multi-Doppler radar retrievals are still challenging. Finally, increasing the number of deep convective cells sampled by such observations better represents the median maximum updraft evolution with sample sizes of more than 10 deep cells, which decreases the error associated with sampling the true population to less than 3 m s−1.

54 ENVIRONMENTAL SCIENCES↗

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗