Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver

Cone beam computed tomography (CBCT) is an imaging modality that provides computed tomographic images using a rotational C-arm equipped with a flat panel detector as part of the Angiography suite. The aim of this technique is to provide additional information to conventional 2D imaging to improve the performance of interventional liver oncology procedures (intraarterial treatments such as chemoembolization or selective internal radiation therapy, and percutaneous tumor ablation). CBCT provides accurate tumor detection and targeting, periprocedural guidance, and post-procedural evaluation of treatment success. This technique can be performed during intraarterial or intravenous contrast agent administration with various acquisition protocols to highlight liver tumors, liver vessels, or the liver parenchyma. The purpose of this review is to present an extensive overview of published data on CBCT in interventional oncology of the liver, for both percutaneous ablation and intraarterial procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Universal human papillomavirus typing by whole genome sequencing following target enrichment: evaluation of assay reproducibility and limit of detection

We recently described a method for unbiased detection of all known human papillomaviruses (HPV) types with the potential for the determination of their variant and integration from the resulting whole genome sequence data. Considering the complex workflow for target-enriched next generation sequencing (NGS), we focused on the reproducibility and limit of detection (LOD) of this new universal HPV typing assay in this study. We evaluated the reproducibility and LOD for HPV genotyping based on our recently published method that used RNA-baits targeting whole genomes of 191 HPV types, Agilent SureSelect protocol for target enrichment and Illumina HiSeq 2500 for sequencing (eWGS, enriched whole genome sequencing). Two libraries, prepared from pooled plasmids representing 9 vaccine HPV types at varying input (1–625 copies/reaction), were sequenced twice giving four replicates for evaluating reproducibility and LOD. eWGS showed high correlation in the number of reads mapped to HPV reference genomes between the two flow-cell lanes within (R 2 = 1) and between experiments (R 2 = 0.99). The number of mapped reads was positively correlated to copy number (β = 13.9, p < 0.0001). The limit of blank (LOB) could be calculated based on mapped reads to HPV types not included in each sample. HPV genotyping was reproducible for all 9 types at 625 copies using multiple cut-off criteria but LOD was 25 copies based on number of reads above LOB even when multiple types were present. eWGS showed no bias for HPV genotyping under single or multiple infection (p = 0.16–0.99). The universal eWGS method for HPV genotyping has sensitivity, competitive with widely used consensus PCR methods with reduced type competition, and with the potential for determination of variant and integration status. The protocol used in this study, using defined samples varying in complexity and copy number, analyzed in replicate and duplicate assays, is applicable to most WGS methods.

59 BASIC BIOLOGICAL SCIENCES↗

TU-F-18A-01: Preliminary Results of a Prototype Quality Control Process for Spectral CT

Purpose: A prototype quality control (QC) phantom and analysis process has been designed specifically to monitor dual-energy CT and address the current lack of quantitative oversight of the spectral capabilities of these scanners. Methods: A prototype solid water phantom was designed with multiple material inserts, and to support both head and body protocols. Inserts included tissue equivalent and material rods (iodine, iron, calcium) at various concentrations. The oval body phantom, measuring 30cm×40cm×15cm, was scanned using four dual-energy protocols with CTDIvol ranges of 19.6–62mGy (0.516 pitch) and 10.3–32.5mGy (0.984 pitch), and rotation times ranging from 0.5-1sec. The circular head phantom, measuring 22cm in diameter by 15cm, was scanned using three dual-energy protocols with CTDIvol ranges of 67–132.6mGy (0.531 pitch) and 36.7–72.7mGy (0.969 pitch), and rotation times ranging from 0.5–0.9sec. All images were reconstructed at 50, 70, 110 and 140 keV, and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy and stability of monoenergetic reconstructions. The phantom was scanned twice on ten GE 750HD CT scanners to evaluate inter-scanner agreement, as well as ten times on a single scanner over a oneweek period to evaluate intra-scanner repeatability. Results: Preliminary analysis revealed consistent (inter- and intra-scanner) iodine quantification accuracy within 10% was only achieved for protocols in the upper half of dose levels assessed when grouped by pitch. Although all scanners undergo rigorous daily single-energy QC, iodine quantification accuracy from one scanner unexpectedly deviated from the other nine substantially. In general, inter-scanner agreement and intra-scanner repeatability varied with dose, rotation time and reconstructed keV. Conclusion: Preliminary results indicate the need for a dual-energy QC process to ensure inter-scanner agreement and intra-scanner repeatability. In particular, iodine quantification accuracy within 10% may not be achievable using lower dose techniques. Future plans include longer term dual-energy CT QC data collection. In-kind financial support was provided by GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Controller Hardware-in-the-Loop Modeling and Operation of a High-Power DC Charging Hub

High-power charging (HPC) concept will be a critical enabler for the wide-scale adoption and integration of electric vehicles (EVs). HPC hubs will have a significant impact on achieving this goal, particularly when considering the charging requirements of next-generation medium and heavy-duty vehicles (MD/HD) used in various vocational scenarios. This emphasizes the significance of evaluating and confirming the technical planning and multi-level operation of HPC hubs through modeling, protocol implementation, and simulation before hardware demonstration. The focus of this study is to develop the architecture, modeling, communication, and real-time controller hardware-in-the-loop (C-HIL) simulation of HPC hubs using the DC distribution system approach. Specifically, this work demonstrates the practical implementation of a custom Smart Energy Management System (SEMS) for a real-time C-HIL HPC hub simulation using the Open Charge Point Protocol (OCPP) for communication. OCPP is implemented on the Node-Red framework and the custom controller is executed in Python. We developed a rule-based controller to demonstrate the proposed approach.

ADVANCED PROPULSION SYSTEMS↗

Annual BTMS Testing Section (SNL)

One of the first milestones of the Behind the Meter Storage (BTMS) program was to develop testing protocols so that the state-of-the-art cell chemistries and form factors could be evaluated against BTMS aggressive performance and lifetime metrics. To help guide this conversation, a pack estimation calculation was run. At the time the team was assuming a worst-case scenario in which the battery alone would need to charge an electric vehicle in 15 minutes with no support from the grid. This calculation varied the amount of current applied by each string or module in the storage system and estimated how many cells (and estimated cost) would be needed to charge an electric vehicle in 15 minutes under the current applied.

25 ENERGY STORAGE↗

Rotating Disk Electrode Standardization and Best Practices in Acidic Oxygen Evolution for Low-Temperature Electrolysis

Efforts in oxygen evolution catalyst development have significantly increased and often use rotating disk electrode half-cells to evaluate intrinsic kinetics and screen materials for short-term durability. Standardizing rotating disk electrode test protocols is critical to experimental accuracy, to realistically assess their potential impact at a device level and to assess how different catalyst approaches and concepts are prioritized. The goal of this study is to provide standardized test protocols and suggest best practices to help reduce variability in ex situ materials characterization in the broader community. Specifically, these protocols focus on test cleanliness and materials choices, including how electrodes are prepared and tested, and the impact on activity observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Contrast Calibration Protocol for X-ray Speckle Visibility Spectroscopy

X-ray free electron lasers, with their ultrashort highly coherent pulses, opened up the opportunity of probing ultrafast nano- and atomic-scale dynamics in amorphous and disordered material systems via speckle visibility spectroscopy. However, the anticipated count rate in a typical experiment is usually low. Therefore, visibility needs to be extracted via photon statistics analysis, i.e., by estimating the probabilities of multiple photons per pixel events using pixelated detectors. Considering the realistic X-ray detector responses including charge cloud sharing between pixels, pixel readout noise, and gain non-uniformity, speckle visibility extraction relying on photon assignment algorithms are often computationally demanding and suffer from systematic errors. In this paper, we present a systematic study of the commonly-used algorithms by applying them to an experimental data set containing small-angle coherent scattering with visibility levels ranging from below 1% to ∼60%. We also propose a contrast calibration protocol and show that a computationally lightweight algorithm can be implemented for high-speed correlation evaluation.

47 OTHER INSTRUMENTATION↗

Towards Next-Generation Urban Decision Support Systems through AI-Powered Construction of Scientific Ontology Using Large Language Models—A Case in Optimizing Intermodal Freight Transportation

The incorporation of Artificial Intelligence (AI) models into various optimization systems is on the rise. However, addressing complex urban and environmental management challenges often demands deep expertise in domain science and informatics. This expertise is essential for deriving data and simulation-driven insights that support informed decision-making. In this context, we investigate the potential of leveraging the pre-trained Large Language Models (LLMs) to create knowledge representations for supporting operations research. By adopting ChatGPT-4 API as the reasoning core, we outline an applied workflow that encompasses natural language processing, Methontology-based prompt tuning, and Generative Pre-trained Transformer (GPT), to automate the construction of scenario-based ontologies using existing research articles and technical manuals of urban datasets and simulations. From these ontologies, knowledge graphs can be derived using widely adopted formats and protocols, guiding various tasks towards data-informed decision support. The performance of our methodology is evaluated through a comparative analysis that contrasts our AI-generated ontology with the widely recognized pizza ontology, commonly used in tutorials for popular ontology software. We conclude with a real-world case study on optimizing the complex system of multi-modal freight transportation. Our approach advances urban decision support systems by enhancing data and metadata modeling, improving data integration and simulation coupling, and guiding the development of decision support strategies and essential software components.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

BitPredator: A Discovery Algorithm for BitTorrent Initial Seeders and Peers

There is a large amount of illegal content being replicated through peer-to-peer (P2P) networks where BitTorrent is dominant; therefore, a framework to profile and police it is needed. The goal of this work is to explore the behavior of initial seeds and highly active peers to develop techniques to correctly identify them. We intend to establish a new methodology and software framework for profiling BitTorrent peers. This involves three steps: crawling torrent indexers for keywords in recently added torrents using Really Simple Syndication protocol (RSS), querying torrent trackers for peer list data and verifying Internet Protocol (IP) addresses from peer lists. We verify IPs using active monitoring methods. Peer behavior is evaluated and modeled using bitfield message responses. We also design a tool to profile worldwide file distribution by mapping IP-to-geolocation and linking to WHOIS server information in Google Earth.

99 GENERAL AND MISCELLANEOUS↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

Rapid AI-based Dissection of Ashes using Raman and XRF Spectroscopy (RADAR-X)

Waste-to-energy (WTE) facilities incinerate ~35 million tons of municipal solid waste annually in the United States. The incineration process reduces the mass and the volume of the waste fraction by over 75 and 95%, respectively. The fraction left after incineration remains as ash residues and is referred to as WTE ash, compromising of bottom and fly ash. In the United States, ~10 million tons of WTE ashes are generated annually and predominantly landfilled because of the lack of secondary end-use pathways. This incurs a significant financial burden (landfilling costs) on U.S. WTE facilities and also results in the loss of materials to the landfill. The primary objective of this research is to understand better the elemental and mineralogical composition of WTE ashes from diverse origins and find composition dependent upcycling pathways for diverting these ashes from landfills. This primary objective was addressed through three research tasks –(Task I) An AI-led Multi-Modal Approach for Compositional Analysis, (Task II) Developing a Dissolution-Based Test for Real Time Analysis, and (Task III) Establishing composition-dependent end uses. The chemical composition of WTE ash is dependent on two factors, i.e., the input waste composition and the operational parameters of a WTE facility (combustion conditions). Amongst these two factors, the input waste composition will likely show spatial and temporal variation. As a result, the chemical composition of WTE ash will also fluctuate. To understand the spatial and temporal variation in WTE ash composition, in Task I, we collected 128 ash samples (62 bottom ash and 66 fly ash samples) from 11 WTE facilities located in 11 U.S. states and characterized them via X-ray Fluorescence, powder X-ray Diffraction, and Raman Spectroscopy. The findings from this extensive characterization work indicated that the key elements in WTE fly ashes are Ca, Cl (greater than 10 wt. %), Si, S, K, Zn ( between 1 and 10 wt. %), Mg, Al, P, Ti, Fe, Cu, Br, and Pb (between 0.1 and 1 wt. %). Similarly, the key elements in WTE bottom ash fraction finer than 45μm are Ca (greater than 10 wt. %), Mg, Al, Si, S, Cl, K, Ti, Fe, Zn (between 1 and 10 wt. %), P, V, Cr, Mn, Cu, Br, and Pb (between 0.1 and 1 wt. %). Here, we note that the dominant fraction of WTE bottom ash is the coarse fraction. The coarse WTE bottom ash fraction (rich in silicon) was not characterized in this study because of excessive grinding requirements and their unsuitability as a supplementary cementitious material due to their coarse nature. The elements in WTE bottom ashes are present as calcite, anhydrite, vaterite, hydroxyapatite, quartz, bassanite, gehlenite, akermanite, hydrocalumite, and portlandite. Similarly, the mineralogical species present in WTE fly ashes are calcium chloride hydroxide, halite, calcite, anhydrite, sylvite, hydrocalumite, vaterite, hannebachite, quartz, and bassanite. Temporal variation in ash composition may also result in significant fluctuations in chemical compositions. Therefore, a WTE facility may need to monitor the ash composition (elemental and mineralogical composition) in real time. In Task I, we evaluated the possibility of using a portable X-ray fluorescence (XRF) spectrometer to monitor the elemental composition in real-time. Specifically, we collected XRF data on identical specimens via a portable XRF spectrometer (low-end) and a lab-based benchtop XRF spectrometer (high-end). The collected data was used to train an A.I. algorithm (portable XRF data as an input and benchtop XRF data as an output) to predict accurate elemental composition using portable XRF data. Finally, we developed a 2-minute photobleaching protocol to monitor the mineralogical characteristics of WTE ashes via Raman spectroscopy. Overall, the activities in Task I improved our understanding of ash composition and developed techniques to monitor elemental and mineralogical composition in near real-time. Based on the findings of Task I, we find that WTE ashes exhibit wide variability in mineralogy. For ICP-based elemental analysis, all the mineralogical species in WTE ashes must be brought into solution. This is traditionally accomplished with acid digestion using a combination of multiple acids. However, acid digestion with multiple acids is time-consuming and often fails to ensure complete digestion of the ash matrix. To address this limitation, in Task II, we developed an alkali-fusion-based digestion protocol using a combination of lithium tetraborate, lithium metaborate, and their combinations as possible alkali fluxes for digesting WTE ashes entirely and rapidly. The validity of the developed method was evaluated on two standard ash specimens, i.e., SRM 1633c coal fly ash and BCR-176R incineration fly ash specimen. The findings suggest that the developed protocol can ensure complete digestion of elements such as Al, Ba, Ca, Cr, Cu, Mg, Mn, P, Sr, V, Zn, Be, K, and rare earth elements. The recent changes in the energy market towards renewables and increased metal recycling have resulted in reduced supplies of supplementary cementitious materials (coal fly ash and slag). Therefore, in Task III, we evaluated the possibility of employing WTE ashes as SCMs. As the chemical composition of WTE ashes varies temporally (on an hourly basis), there was also a need to develop tests that can evaluate the suitability of material to act as supplementary cementitious material rapidly, i.e., in a few minutes. Therefore, in Task II, we also developed a rapid test to assess the suitability of a material to act as an SCM in 5 minutes. This represents a significant advance over the state-of-the-art R 3 test, which takes ~144 hours. This test was initially validated on amorphous aluminosilicates, such as calcined clays, and could be extended to evaluate other industrial by-products, such as WTE ashes. In Task III, we evaluated the possibility of employing WTE ashes for two applications, i.e., as an SCM and a lime substitute for clay stabilization. The findings from Task I indicated that WTE ashes are enriched in chlorine and, therefore, cannot be used directly as an SCM due to corrosion-related risks and altered hydration kinetics. Accordingly, we developed an ash treatment protocol to reduce the solubility of chlorine-containing species in WTE ashes. The developed treatment protocol also immobilized lead in certain mineral forms. As a result of the treatment, WTE ashes can be used as SCMs without any corrosion or heavy metal leaching concerns. The second application examined in this study was clay stabilization. WTE ashes are calcium-rich and can be an adequate lime replacement for clay stabilization. Our findings reveal that the sum of the concentrations of Ca(OH) 2 and CaClOH controls the clay stabilization capability of WTE ashes. In summary, in this work, we evaluated the elemental and mineralogical characteristics of U.S. WTE ashes from diverse origins and developed tests to evaluate the chemical characteristics of these ashes in real time through a portable XRF and a benchtop Raman spectrometer. Based on the chemical characteristics of these ashes, we developed an ash treatment process to enable the use of WTE ashes as an SCM and also evaluated the possibility of employing these ashes for clay stabilization. Overall, the findings from this work enables the diversion of WTE ashes from landfills for multiple end-uses, i.e., as an SCM or a lime substitute for clay stabilization.

36 MATERIALS SCIENCE↗

Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

60 APPLIED LIFE SCIENCES↗

Assessing the Consistency of Estimated Ground Cover Fractions between the BLM AIM Method and Optical Remote Sensing Method

Since 2012, Argonne National Laboratory (Argonne) has supported the Bureau of Land Management (BLM) in developing remote sensing methodologies for long-term environmental monitoring of Palo Verde Mesa in eastern Riverside County, California, including methods for: detailed mapping of ephemeral streams, estimating fractional cover of desert-land surface components (e.g., trees, shrubs, litters, and bare ground), evaluating erosion risk or land stability, and characterizing vegetation alliances using spatial structure and geostatistical approaches. These studies showed the promise of remote sensing for monitoring changes in desert landscapes by providing information that would be difficult to obtain through field surveys. During this time the BLM has also worked to establish long-term monitoring protocols and compiled field-observation data collected using standardized protocols from the Assessment, Inventory, and Monitoring (AIM) strategy. The AIM data can be compared to data derived from remote sensing methods to evaluate their relative operational utility in monitoring landscape change. If ground cover estimated using remotely sensed imagery is comparable to AIM ground cover estimates, then remote sensing can be used to monitor whether any land cover change in desert landscapes may be related to solar energy development. Therefore, the goal of this study was to determine the consistency in ground cover estimates between AIM data and those derived from publicly- available remotely sensed imagery, such as that available through the U.S. Department of Agriculture, National Agricultural Imagery Program (NAIP), to examine feasibility of a remote sensing method for complementing AIM monitoring. Based on the image analysis in this study, we also provide recommendations for how small unmanned aerial system (sUAS) data may be used to complement BLM’s AIM data and NAIP imagery for future vegetation monitoring. The ground cover types we originally planned to investigate were trees, shrubs, and bare ground. However, the small sample size and a limited range of cover fraction of trees and shrubs in the AIM dataset (e.g., 33 samples with a maximum shrub cover of 18%, 14 samples with a maximum tree cover of 17%) did not allow for performing a meaningful evaluation for the remote sensing approach. Therefore, we conducted the study focusing on bare ground, foliar, and rock cover, all of which are indicators reported in the AIM remote sensing dataset.

47 OTHER INSTRUMENTATION↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

Survival and Neurocognitive Outcomes After Cranial or Craniospinal Irradiation Plus Total-Body Irradiation Before Stem Cell Transplantation in Pediatric Leukemia Patients With Central Nervous System Involvement

Purpose: To evaluate survival and neurocognitive outcomes in pediatric acute lymphoblastic leukemia (ALL) patients with central nervous system (CNS) involvement treated according to an institutional protocol with stem cell transplantation (SCT) and a component of craniospinal irradiation (CSI) in addition to total-body irradiation (TBI) as preparative regimen. Methods and Materials: Forty-one pediatric ALL patients underwent SCT with TBI and received additional cranial irradiation or CSI because of CNS leukemic involvement. Prospective neurocognitive testing was performed before and after SCT in a subset of patients. Cox regression models were used to determine associations of patient and disease characteristics and treatment methods with outcomes. Results: All patients received a cranial radiation boost; median total cranial dose was 24 Gy. Eighteen patients (44%) received a spinal boost; median total spinal dose for these patients was 18 Gy. Five-year disease-free survival (DFS) for all patients was 67%. Those receiving CSI had a trend toward superior DFS compared with those receiving a cranial boost alone (hazard ratio 3.23, P=.14). Patients with isolated CNS disease before SCT had a trend toward superior DFS (hazard ratio 3.64, P=.11, 5-year DFS 74%) compared with those with combined CNS and bone marrow disease (5-year DFS 59%). Neurocognitive testing revealed a mean post-SCT overall intelligence quotient of 103.7 at 4.4 years. Relative deficiencies in processing speed and/or working memory were noted in 6 of 16 tested patients (38%). Pre- and post-SCT neurocognitive testing revealed no significant change in intelligence quotient (mean increase +4.7 points). At a mean of 12.5 years after transplant, 11 of 13 long-term survivors (85%) had completed at least some coursework at a 2- or 4-year college. Conclusion: The addition of CSI to TBI before SCT in pediatric ALL with CNS involvement is effective and well-tolerated. Craniospinal irradiation plus TBI is worthy of further protocol investigation in children with CNS leukemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The proposed algorithm is effective for lung lobe segmentation in absence of auxiliary structures such as vessels and airways. The most challenging cases are those with mostly incomplete, absent, or near-absent fissures and in cases with poorly revealed fissures due to high image noise. However, the authors observe good performance even in the majority of these cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗