Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Deconstruction of Woody Biomass via Protic and Aprotic Ionic Liquid Pretreatment for Ethanol Production

Ionic liquids (ILs) have emerged as important solvents for conversion of lignocellulosic feedstocks to fuels and chemicals due to their ability to enable efficient biomass deconstruction and fractionation. Woody biomass derived from forest and agricultural residues has the potential to be used for production of biofuels and its removal from forests can help mitigate disastrous wildfires in fire-prone states like California. This study evaluated woody biomass types (pine, almond, walnut, and fir) from California as potential biofuel feedstocks. The feedstocks were pretreated with the ILs cholinium lysinate ([Ch][Lys]) and ethanolamine acetate ([EOA][OAc]), followed by enzymatic hydrolysis and fermentation of lignocellulosic sugars to produce ethanol. Under optimal conditions, [EOA][OAc] pretreatment and enzymatic hydrolysis generated glucose and xylose yields in the range of 24-82 and 14-80%, respectively, while glucose and xylose yields for the [Ch][Lys] ranged between 28-83 and 23-80%, respectively. Maximum fermentable sugar was released from almond wood, and the lowest amount was from pine and fir. Further, blends of feedstocks were also explored, and a blend with a mass ratio of 2/2/1 (almond/walnut/pine) resulted in maximum glucose and xylose (>90%) yields using [Ch][Lys]. Fermentation of this hydrolysate using a C5-utilizing strain of Saccharomyces cerevisiae resulted in a maximum ethanol concentration of 17.9 g/L for mixture biomass hydrolysate, corresponding to 60.8% fermentation efficiency. This study represents the first demonstration of the use of these ILs for pretreatment of woody biomass blends that resulted in a high overall conversion efficiency for ethanol production.

09 BIOMASS FUELS↗

Wound Complications in Preoperatively Irradiated Soft-Tissue Sarcomas of the Extremities

Purpose: To determine whether the involvement of plastic surgery and the use of vascularized tissue flaps reduces the frequency of major wound complications after radiation therapy for soft-tissue sarcomas (STS) of the extremities. Methods and Materials: This retrospective study evaluated patients with STS of the extremities who underwent radiation therapy before surgery. Major complications were defined as secondary operations with anesthesia, seroma/hematoma aspirations, readmission for wound complications, or persistent deep packing. Results: Between 1996 and 2010, 73 patients with extremity STS were preoperatively irradiated. Major wound complications occurred in 32% and secondary operations in 16% of patients. Plastic surgery closed 63% of the wounds, and vascularized tissue flaps were used in 22% of closures. When plastic surgery performed closure the frequency of secondary operations trended lower (11% vs 26%; P=.093), but the frequency of major wound complications was not different (28% vs 38%; P=.43). The use of a vascularized tissue flap seemed to have no effect on the frequency of complications. The occurrence of a major wound complication did not affect disease recurrence or survival. For all patients, 3-year local control was 94%, and overall survival was 72%. Conclusions: The rates of wound complications and secondary operations in this study were very similar to previously published results. We were not able to demonstrate a significant relationship between the involvement of plastic surgery and the rate of wound complications, although there was a trend toward reduced secondary operations when plastic surgery was involved in the initial operation. Wound complications were manageable and did not compromise outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly Available Nuclear Power for Mission-Critical Applications

Some energy consumers require power on an anytime, all-year-round basis with a high level of certainty, including defense installations, isolated communities, and some industrial processes. For these customers, interruptions in electricity or heat can mean substantial financial loss or even loss of life. In the absence of grid-scale energy storage, a high level of power availability can be accomplished only through the robustness and redundancy of power generators. The NuScale small modular reactor design is well suited to provide highly available power because of several features related to both the nuclear steam supply system and the overall plant design. In analogy to Redundant Array of Independent Disks (RAID) systems used to provide highly reliable data storage, a NuScale plant can assure sustained power generation by virtue of its Redundant Array of Integral Reactors (RAIR).This paper describes the NuScale RAIR plant features and summarizes the results of a rigorous analysis of RAIR availability as a function of power or, conversely, the RAIR plant output power as a function of power availability. The analysis utilized the Matrix Laboratory code (MATLAB) and included probability distributions for the frequency and duration of module outages due to planned and unplanned events. Further, the study evaluated the impact of implementing turbine bypass rather than module shutdown and using one or more modules to supply house loads in the case of loss of off-site power (LOOP). Availability results are presented for a 12-module RAIR plant with and without turbine bypass enabled during a LOOP and for different possible connections to the off-site power distribution grid and dedicated service loads. Results indicate that a very high level of availability can be achieved at relatively high power output levels, regardless of turbine bypass and dedicated load connection, compared to the operating fleet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A computational model to generate simulated three-dimensional breast masses

Purpose: To develop algorithms for creating realistic three-dimensional (3D) simulated breast masses and embedding them within actual clinical mammograms. The proposed techniques yield high-resolution simulated breast masses having randomized shapes, with user-defined mass type, size, location, and shape characteristics. Methods: The authors describe a method of producing 3D digital simulations of breast masses and a technique for embedding these simulated masses within actual digitized mammograms. Simulated 3D breast masses were generated by using a modified stochastic Gaussian random sphere model to generate a central tumor mass, and an iterative fractal branching algorithm to add complex spicule structures. The simulated masses were embedded within actual digitized mammograms. The authors evaluated the realism of the resulting hybrid phantoms by generating corresponding left- and right-breast image pairs, consisting of one breast image containing a real mass, and the opposite breast image of the same patient containing a similar simulated mass. The authors then used computer-aided diagnosis (CAD) methods and expert radiologist readers to determine whether significant differences can be observed between the real and hybrid images. Results: The authors found no statistically significant difference between the CAD features obtained from the real and simulated images of masses with either spiculated or nonspiculated margins. Likewise, the authors found that expert human readers performed very poorly in discriminating their hybrid images from real mammograms. Conclusions: The authors’ proposed method permits the realistic simulation of 3D breast masses having user-defined characteristics, enabling the creation of a large set of hybrid breast images containing a well-characterized mass, embedded within real breast background. The computational nature of the model makes it suitable for detectability studies, evaluation of computer aided diagnosis algorithms, and teaching purposes.

60 APPLIED LIFE SCIENCES↗

SU-F-T-432: Magnetic Field Dose Effects for Various Radiation Beam Geometries for Patients Treated with Hypofractionated Partial Breast Irradiation

Purpose: Hypofractionated partial breast irradiation (HPBI) is being used at our clinic to treat inoperable breast cancer patients who have advanced disease. We are investigating how these patients could benefit from being treated in an MRI-linac, where real-time daily MRI tumor imaging and plan adaptation would be possible. As a first step, this study evaluates the dosimetric impact of the magnetic field for different radiation beam geometries on relevant OARs. Methods: Five patients previously treated using HPBI were selected. Six treatment plans were generated for each patient, evaluating three beam geometries (VMAT, IMRT, 3DCRT) with and without B{sub 0}=1.5 T. The Monaco TPS was used with the Elekta MRI-Linac beam model, where the magnetic field is orthogonal to the radiation beam. All plans were re-scaled to the same isocoverage with a prescription of 40Gy/5 to the PTV. Plans were evaluated for the effect of the magnetic field and beam modality on skin V{sub 3} {sub 0}, lung V{sub 2} {sub 0} and mean heart dose. Results: Averaged over all patients, skin V{sub 3} {sub 0}for 3DCRT was higher than VMAT and IMRT (by +22% and +21%, with B{sub 0}-ON). The magnetic field caused larger increases in skin V{sub 3} {sub 0}for 3DCRT (+8%) than VMAT (+3%) and IMRT (+4%) compared with B{sub 0}-OFF. With B{sub 0}-ON, 3DCRT had a markedly lower mean heart dose than VMAT (by 538cGy) and IMRT (by 562cGy); for lung V{sub 2} {sub 0}, 3DCRT had a marginally lower dose than VMAT (by −2.2%) and IMRT (also −2.2%). The magnetic field had minimal effect on the mean heart dose and lung V{sub 2} {sub 0} for all geometries. Conclusion: The decreased skin dose in VMAT and IMRT can potentially mitigate the effects of skin reactions for HPBI in an MRI-linac. This study illustrated that more beam angles may result in lower skin toxicity and better tumor conformality, with the trade-off of elevated heart and lung doses. We are receiving funding support from Elekta.

60 APPLIED LIFE SCIENCES↗

Better bang for your buck? Comparing savings realization from ESPCs and direct-funded projects

Energy savings performance contracts (ESPCs) offer an opportunity to tremendously scale decarbonization projects, given their paid-from-savings premise. However, prospective customers still question whether ESPC is worth the effort and expense. This study evaluates the savings realization rates of ESPCs compared to direct-funded projects using ENERGY STAR Portfolio Manager (ESPM) benchmarking data. It compares normalized EUIs from ESPM before and after energy conservation projects implemented via ESPC or direct funding in roughly 450 federal buildings. This documented change, ideally a savings, can then be compared to the estimated savings from the energy conservation initiative in order to generate a rough realization rate. Preliminary results indicate a notably greater savings realization rate for the ESPC buildings (median = 105% of estimated savings) than those that underwent direct-funded projects (median = 46%). Because of a shortage of good quality data and the wide range in results, the difference is only significant at the p < 0.20 level. However, the higher savings realization of ESPCs corroborates the authors’ 2014 findings using a different comparison method. With continued soft government funding and regulatory impediments for climate change mitigation in the U.S., financed, paid-from-savings project models (e.g., ESPC, PACE, EaaS and others) certainly merit more attention. This study’s results are particularly compelling (and encouraging) given the country’s likely reliance on these vehicles to address existing building retrofits.

Earni, Shankar↗

Southern company energy storage study :

This study evaluates the business case for additional bulk electric energy storage in the Southern Company service territory for the year 2020. The model was used to examine how system operations are likely to change as additional storage is added. The storage resources were allowed to provide energy time shift, regulation reserve, and spinning reserve services. Several storage facilities, including pumped hydroelectric systems, flywheels, and bulk-scale batteries, were considered. These scenarios were tested against a range of sensitivities: three different natural gas price assumptions, a 15% decrease in coal-fired generation capacity, and a high renewable penetration (10% of total generation from wind energy). Only in the elevated natural gas price sensitivities did some of the additional bulk-scale storage projects appear justifiable on the basis of projected production cost savings. Enabling existing peak shaving hydroelectric plants to provide regulation and spinning reserve, however, is likely to provide savings that justify the project cost even at anticipated natural gas price levels. Transmission and distribution applications of storage were not examined in this study. Allowing new storage facilities to serve both bulk grid and transmission/distribution-level needs may provide for increased benefit streams, and thus make a stronger business case for additional storage.

Ellison, James↗

Assessing climate-change-induced flood risk in the Conasauga River watershed: an application of ensemble hydrodynamic inundation modeling

Abstract. This study evaluates the impact of potential future climate change on flood regimes, floodplain protection, and electricity infrastructures across the Conasauga River watershed in the southeastern United States through ensemble hydrodynamic inundation modeling. The ensemble streamflow scenarios were simulated by the Distributed Hydrology Soil Vegetation Model (DHSVM) driven by (1) 1981–2012 Daymet meteorological observations and (2) 11 sets of downscaled global climate models (GCMs) during the 1966–2005 historical and 2011–2050 future periods. Surface inundation was simulated using a GPU-accelerated Two-dimensional Runoff Inundation Toolkit for Operational Needs (TRITON) hydrodynamic model. A total of 9 out of the 11 GCMs exhibit an increase in the mean ensemble flood inundation areas. Moreover, at the 1 % annual exceedance probability level, the flood inundation frequency curves indicate a ∼ 16 km2 increase in floodplain area. The assessment also shows that even after flood-proofing, four of the substations could still be affected in the projected future period. The increase in floodplain area and substation vulnerability highlights the need to account for climate change in floodplain management. Overall, this study provides a proof-of-concept demonstration of how the computationally intensive hydrodynamic inundation modeling can be used to enhance flood frequency maps and vulnerability assessment under the changing climatic conditions.

54 ENVIRONMENTAL SCIENCES↗

Assessment of RELAP5-3D Code with Molten Salt Heat Transfer Experiments

The accurate thermal-hydraulic assessment of thermal storage systems is crucial for addressing the integrity and performance of the storage system design. This is particularly important for thermal storage systems using molten salts as a heat transport and storage medium, as the chemical corrosion and erosion by the high-temperature molten salts can cause serious damage to the structural components of the storage system. To understand these effects for TerraPower’s Natrium® Demonstration Reactor design, the system thermal-hydraulic analysis code, RELAP5-3D, is utilized to analyze the thermal storage system. This study evaluates two heat transfer correlations implemented in the RELAP5-3D code—the Dittus-Boelter and Gnielinski correlations—using selected benchmark cases from two molten salt heat transfer experiments conducted at Xi’an Jiao Tong University and the German Aerospace Center. The Nusselt numbers calculated using the Gnielinski correlation agree with the experimental data within ±5% of the relative deviations at 300°C and 400°C. With the increasing Reynolds numbers, the Dittus-Boelter correlation underestimates the Nusselt numbers by up to 22% compared to the Gnielinski correlation. Comparison of the RELAP5-3D calculation results with experimental data at a high temperature of 550°C revealed that the thermo-chemical characteristics of solar salt at high temperatures surpassing the decomposition temperatures of nitrate salts reduce the accuracy of heat transfer model of the RELAP5-3D code. Specifically, it has been observed that the temperatures of the wall surface and liquid near the wall can surpass the decomposition temperatures, even though the bulk temperature of molten salts remains significantly lower than these decomposition temperatures. In summary, this study recommends the use of the Gnielinski correlation for the heat transfer analysis of molten salt, rather than the Dittus-Boelter correlation.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Investigation of Debonding Effect in Internal Replacement Pipe System Under Lateral Loading

The aging pipeline infrastructure around the world necessitates immediate rehabilitation. Internal replacement pipe (IRP) is a trenchless system offering a versatile and cost-effective solution across a variety of industries, including oil, natural gas, water, and wastewater. As a structural pipeline repair system, IRPs are subject to lateral deformation because of surface traffic loading. The present study evaluates the impact of adhesion between the host pipe and the IRP, with a focus on assessing the debonding effect on the behavior of the repair system under lateral deformation and bending. This was achieved using a comprehensive approach, including experimental, numerical, and analytical techniques. Varying levels of adhesive strength resulting from different methods of surface preparation were considered. The effectiveness of the IRP system on both discontinuous host pipes with various crack widths and continuous host pipes was also investigated. The results demonstrate that adhesive strength exerts a significant influence on the repair system, especially in the case of narrow circumferential cracks, while its impact on the continuous system is minimal. For optimal performance, it is essential to choose adhesives that possess sufficient shear strength while also accounting for the required debonding length. This approach ensures that minor discontinuities are effectively controlled, thereby enhancing the system′s fatigue life. The reliable determination of the maximum allowable shear strength for the adhesive or the debonding length can ensure that it does not negatively affect fatigue life. The findings presented in this study offer new insights into the development of trenchless repair techniques that can enhance system performance and extend service life.

Tien, Tri C. M.↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Degradation of different elastomeric polymers in simulated geothermal environments at 300°C

This study evaluates the degradation of six different elastomeric polymers used for O-rings: EPDM, FEPM, type I- and II-FKM, FFKM, and FSR, in five different simulated geothermal environments at 300 °C: 1) non-aerated steam/cooling cycles, 2) aerated steam/cooling cycles, 3) water-based drilling fluid, 4) CO 2 -rich geo-brine fluid, and, 5) heat–cool water quenching cycles. The factors assessed included the extent of oxidation, changes in thermal behavior, micro-defects, permeation of ionic species from the test environments into the O-rings, silicate-related scale-deposition, and changes in the O-rings' elastic modulus. The reliability of the O-rings to maintain their integrity depended on the elastomeric polymer composition and the exposure environment. FSR disintegrated while EPDM was oxidized only to some degree in all the environments, FKM withstood heat-water quenching but underwent chemical degradation, FEPM survived in all the environments with the exception of heat-water quenching where it underwent severe oxidation-induced degradation, and FFKM displayed outstanding compatibility with all the tested environments. This study discusses the degradation mechanisms of the polymers under the aforementioned conditions.

15 GEOTHERMAL ENERGY↗

Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for {<=}1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of heat treatment on the microstructure of medium burn-up U-Mo monolithic fuel foils

Using scanning electron microscopy (SEM), this study evaluates the microstructure evolution of U-Mo fuel foils made with and without heat treatment at medium burn-up (of approximately 5 x 10 21 f/cm 3 ). The impact of annealing treatments on critical microstructural properties of the U-Mo fuel foils, including porosity, grain structure, Mo homogeneity, and fuel interaction with the Zr interlayer, was examined using large area lift outs (LALOs). The heat-treated specimens presented less grain refining at these burnups when compared to the un-heated specimens. Grain refinement was associated with porosities and fission products precipitation. Heat treatment can reduce fuel swelling during irradiation. Chemical inhomogeneity (Mo banding) was found to persist in the un-heated samples but was not present in the heat-treated samples. Thus, heat-treated U-Mo foils allows for more predictable fuel behavior under irradiation with respect to un-heated foils. The U-Mo and Zr interaction layer appears to be thicker and more continuous in the heat-treated sample which has been associated with stronger interface integrity during irradiation, as also observed in previous studies. These observations may indicate an overall improved performance of heat-treated fuel foil in a reactor. Further, the effect of local burn-up on grain size/refinement and porosities in each LALO specimen, sampled from different positions in the fuel foil, was difficult to analyze due to the large standard deviation of these parameters. Finally, evidence of grain refinement by polygonization may be present in these specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Scanning Methods for Ship-to-Rail Intermodal Cargo Containers

The Department of Homeland Security’s (DHS) Domestic Nuclear Detection Office (DNDO) runs the Rail Test Center (RTC) at the Port of Tacoma (POT). The RTC affords DNDO with the opportunity to test radiological and nuclear threat detection systems associated with the unique on-dock rail environment while in an operational seaport. DNDO selected the Pacific Northwest National Laboratory (PNNL) to manage the RTC. The RTC is conducting various evaluation studies to assess scanning opportunities in terms of their affects on the num-ber of container moves required and the affect that the scanning opportunity has on the time it takes to move a container through the on-dock transfer process from ship to rail. The velocity and the number of container moves are directly associated with incremental costs to the terminal operators; increases in either of these parameters help in-form the potential for incremental costs that would result from the implementation of the opportunity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Correlation and prediction uncertainties in the CyberKnife Synchrony respiratory tracking system

Purpose: The CyberKnife uses an online prediction model to improve radiation delivery when treating lung tumors. This study evaluates the prediction model used by the CyberKnife radiation therapy system in terms of treatment margins about the gross tumor volume (GTV). Methods: From the data log files produced by the CyberKnife synchrony model, the uncertainty in radiation delivery can be calculated. Modeler points indicate the tracked position of the tumor and Predictor points predict the position about 115 ms in the future. The discrepancy between Predictor points and their corresponding Modeler points was analyzed for 100 treatment model data sets from 23 de-identified lung patients. The treatment margins were determined in each anatomic direction to cover an arbitrary volume of the GTV, derived from the Modeler points, when the radiation is targeted at the Predictor points. Each treatment model had about 30 min of motion data, of which about 10 min constituted treatment time; only these 10 min were used in the analysis. The frequencies of margin sizes were analyzed and truncated Gaussian normal functions were fit to each direction's distribution. The standard deviation of each Gaussian distribution was then used to describe the necessary margin expansions in each signed dimension in order to achieve the desired coverage. In this study, 95% modeler point coverage was compared to 99% modeler coverage. Two other error sources were investigated: the correlation error and the targeting error. These were added to the prediction error to give an aggregate error for the CyberKnife during treatment of lung tumors. Results: Considering the magnitude of 2{sigma} from the mean of the Gaussian in each signed dimension, the margin expansions needed for 95% modeler point coverage were 1.2 mm in the lateral (LAT) direction and 1.7 mm in the anterior-posterior (AP) direction. For the superior-inferior (SI) direction, the fit was poor; but empirically, the expansions were 3.5 mm. For 99% modeler point coverage, the AP margin was 3.6 mm and the lateral margin was 2.9 mm. The SI margins for 99% modeler point coverage were highly variable. The aggregate error at 95% was 6.9 mm in the SI direction, 4.6 mm in the AP direction, and 3.5 in the lateral direction. Conclusions: The Predictor points follow the Modeler points closely. Margins were found in each clinical direction that would provide 95% modeler point coverage for 95% of the models reviewed in this study. Similar margins were found in two clinical directions for 99% modeler point coverage in 95% of models. These results can offer guidance in the selection of CTV margins for treatment with the CyberKnife.

61 RADIATION PROTECTION AND DOSIMETRY↗

Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites

This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38 and 86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between the release rate and the reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of the mixing ratio readings at downwind sensors were greater than the site’s baseline plus two standard deviations. Four of seven total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from −100% to 24% for solution D, −100% to −43% for solution E, −25% for solution F (solution F was only at one site), and −99% to 430% for solution G, with an overall average of −29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within ±2.5 kg/h of the study team’s best estimate of site-level emissions at the time of the releases.

42 ENGINEERING↗