Search NASA⌕ Search

SEARCH · Search NASA

Results for “feedback control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Output feedback non-linear decoupled control synthesis and observer design for manoeuvring aircraft

A study of the applicability of nonlinear decoupling theory to the design of control systems using output feedback for maneuvering aircraft is presented. The response variables chosen for decoupled control were angular velocity components along roll, pitch, and yaw axes, angle of attack (p), and angle of sideslip, using aileron, rudder, and elevator controls. An observer design for a class of nonlinear systems was presented and this method was used to estimate angle of attack and sideslip; an approximate observer was obtained by neglecting derivatives of p and aileron deflection angles and it was used in a simulation study. A simulation study showed that precise rapid combined lateral and longitudinal maneuvers can be performed; it was also demonstrated that a bank-angle-command outer loop could be designed for precise bank angles changes and simultaneous large lift maneuvers.

Singh, S. N.↗

Optimal integral controller with sensor failure accommodation

An Optimal Integral Controller that readily accommodates Sensor Failure - without resorting to (Kalman) filter or observer generation - has been designed. The system is based on Navy-sponsored research for the control of high performance aircraft. In conjunction with a NASA developed Numerical Optimization Code, the Integral Feedback Controller will provide optimal system response even in the case of incomplete state feedback. Hence, the need for costly replication of plant sensors is avoided since failure accommodation is effected by system software reconfiguration. The control design has been applied to a particularly ill-behaved, third-order system. Dominant-root design in the classical sense produced an almost 100 percent overshoot for the third-order system response. An application of the newly-developed Optimal Integral Controller - assuming all state information available - produces a response with no overshoot. A further application of the controller design - assuming a one-third sensor failure scenario - produced a slight overshoot response that still preserved the steady state time-point of the full-state feedback response. The control design should have wide application in space systems.

Alberts, T.↗

Nonlinear power flow control applications to conventional generator swing equations subject to variable generation.

In this paper, the swing equations for renewable generators are formulated as a natural Hamiltonian system with externally applied non-conservative forces. A two-step process referred to as Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) is used to analyze and design feedback controllers for the renewable generator system. This formulation extends previous results on the analytical verification of the Potential Energy Boundary Surface (PEBS) method to nonlinear control analysis and design and justifies the decomposition of the system into conservative and non-conservative systems to enable a two-step, serial analysis and design procedure. In particular, this approach extends the work done by developing a formulation which applies to a larger set of Hamiltonian Systems that has Nearly Hamiltonian Systems as a subset. The results of this research include the determination of the required performance of a proposed Flexible AC Transmission System (FACTS)/storage device to enable the maximum power output of a wind turbine while meeting the power system constraints on frequency and phase. The FACTS/storage device is required to operate as both a generator and load (energy storage) on the power system in this design. The Second Law of Thermodynamics is applied to the power flow equations to determine the stability boundaries (limit cycles) of the renewable generator system and enable design of feedback controllers that meet stability requirements while maximizing the power generation and flow to the load. Necessary and sufficient conditions for stability of renewable generators systems are determined based on the concepts of Hamiltonian systems, power flow, exergy (the maximum work that can be extracted from an energy flow) rate, and entropy rate.

17 WIND ENERGY↗

Feedback control of two beam, two joint systems with distributed flexibility

The control of the flexible motion in a plane of two pinned beams is addressed with application to remote manipulators. Three types of linear feedback control schemes are considered: joint angle and velocity feedback with (GRC) and without (IJC) cross joint feedback, and feedback of flexible state variables (FFC). Two models of the distributed flexibility are presented along with some results obtained from them. The relative merit of the three control schemes is discussed.

Book, W. J.↗

Lyapunov-based control designs for flexible-link manipulators

A feedback controller for the stabilization of closed-loop systems is proposed which is based on the Liapunov stability criterion. A feedback control law is first generated for the linear portion of the system equation using linear control theory. A feedback control is then designed for the nonlinear portion of the system equation by making negative the time derivative of a positive definite Liapunov function.

Juang, Jer-Nan↗

Performance capabilities of a JPL dual-arm advanced teleoperation system

The system comprises: (1) two PUMA 560 robot arms, each equipped with the latest JPL developed smart hands which contain 3-D force/moment and grasp force sensors; (2) two general purpose force reflecting hand controllers; (3) a NS32016 microprocessors based distributed computing system together with JPL developed universal motor controllers; (4) graphics display of sensor data; (5) capabilities for time delay experiments; and (6) automatic data recording capabilities. Several different types of control modes are implemented on this system using different feedback control techniques. Some of the control modes and the related feedback control techniques are described, and the achievable control performance for tracking position and force trajectories are reported. The interaction between position and force trajectory tracking is illustrated. The best performance is obtained by using a novel, task space error feedback technique.

Szakaly, Z. F.↗

Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units

Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear optimal control with tensors - Some computational issues

Some computational issues associated with the calcualtion of optimal feedback controls for nonlinear systems in a tensor setting are described. The specific issues addressed pertain to the combinatorial nature of the loading of the elements into tensors used to represent the system, cost, and feedback, and the subsequent calculations involving these elements. Particular attention is given to: the symmetric tensor algebra which is a natural setting for representing polynomials; the conversions between symmetric and nonsymmetric tensors; the general nature of the calculations required; and the solution equation for nonlinear optimal feedback control. It is concluded that nonlinear tensor feedback can improve performance both in terms of system responses and in terms of system stability region.

Osullivan, J. A.↗

Open-loop-feedback-optimal adaptive stochastic control of linear systems

This paper considers the suboptimal stochastic control of linear discrete-time dynamical systems with unknown or stochastically varying parameters. The suboptimal scheme is based upon the use of the open-loop-feedback-optimal method. The state and parameter estimates are generated by an extended Kalman filter algorithm. Numerical results for first-order systems are presented.

Ku, R.↗

Design of state-feedback controllers including sensitivity reduction, with applications to precision pointing

The design procedure of feedback controllers was described and the considerations for the selection of the design parameters were given. The frequency domain properties of single-input single-output systems using state feedback controllers are analyzed, and desirable phase and gain margin properties are demonstrated. Special consideration is given to the design of controllers for tracking systems, especially those designed to track polynomial commands. As an example, a controller was designed for a tracking telescope with a polynomial tracking requirement and some special features such as actuator saturation and multiple measurements, one of which is sampled. The resulting system has a tracking performance comparing favorably with a much more complicated digital aided tracker. The parameter sensitivity reduction was treated by considering the variable parameters as random variables. A performance index is defined as a weighted sum of the state and control convariances that sum from both the random system disturbances and the parameter uncertainties, and is minimized numerically by adjusting a set of free parameters.

Hadass, Z.↗

Biocybernetic system evaluates indices of operator engagement in automated task

A biocybernetic system has been developed as a method to evaluate automated flight deck concepts for compatibility with human capabilities. A biocybernetic loop is formed by adjusting the mode of operation of a task set (e.g., manual/automated mix) based on electroencephalographic (EEG) signals reflecting an operator's engagement in the task set. A critical issue for the loop operation is the selection of features of the EEG to provide an index of engagement upon which to base decisions to adjust task mode. Subjects were run in the closed-loop feedback configuration under four candidate and three experimental control definitions of an engagement index. The temporal patterning of system mode switching was observed for both positive and negative feedback of the index. The indices were judged on the basis of their relative strength in exhibiting expected feedback control system phenomena (stable operation under negative feedback and unstable operation under positive feedback). Of the candidate indices evaluated in this study, an index constructed according to the formula, beta power/(alpha power + theta power), reflected task engagement best.

Cerebral Cortex/physiology↗

Ultimate temperature stability of a magnetic refrigerator

In recent years there has been an interest in using adiabatic demagnetization refrigeration in space to cool bolometers to the 0.1-0.3 K temperature range. Two different demagnetization schemes have been proposed for such refrigerators. Both methods start the same way: an isothermal magnetization followed by an adiabatic demagnetization. Once the operating temperature is reached, the two methods differ. The first method uses feedback control to perform an isothermal demagnetization. As reported, this system is limited by the resolution of the analog-to-digital converter used. While the stability of this system is the best reported to date (0.5 mK at 200 mK for 14 h), it is several orders of magnitude worse than the theoretical limit. The second method uses a complete demagnetization and allows the temperature to drift up uncontrolled. This system has the disadvantage that the responsivity and noise of a bolometer will also drift, and so will require continuous recalibration. There is some concern that fluctuations in the temperature control system of the first method would adversely affect the bolometer performance by increasing the system noise. The purpose of this note is to present the ultimate stability limit of an isothermal demagnetization feedback control system.

Kittel, P.↗

Structural analysis and design of multivariable control systems: An algebraic approach

The application of algebraic system theory to the design of controllers for multivariable (MV) systems is explored analytically using an approach based on state-space representations and matrix-fraction descriptions. Chapters are devoted to characteristic lambda matrices and canonical descriptions of MIMO systems; spectral analysis, divisors, and spectral factors of nonsingular lambda matrices; feedback control of MV systems; and structural decomposition theories and their application to MV control systems.

Tsay, Yih Tsong↗

System Finds Horizontal Location of Center of Gravity

An instrumentation system rapidly and repeatedly determines the horizontal location of the center of gravity of a laboratory vehicle that slides horizontally on three air bearings (see Figure 1). Typically, knowledge of the horizontal center-of-mass location of such a vehicle is needed in order to balance the vehicle properly for an experiment and/or to assess the dynamic behavior of the vehicle. The system includes a load cell above each air bearing, electronic circuits that generate digital readings of the weight on each load cell, and a computer equipped with software that processes the readings. The total weight and, hence, the mass of the vehicle are computed from the sum of the load-cell weight readings. Then the horizontal position of the center of gravity is calculated straightforwardly as the weighted sum of the known position vectors of the air bearings, the contribution of each bearing being proportional to the weight on that bearing. In the initial application for which this system was devised, the center- of-mass calculation is particularly simple because the air bearings are located at corners of an equilateral triangle. However, the system is not restricted to this simple geometry. The system acquires and processes weight readings at a rate of 800 Hz for each load cell. The total weight and the horizontal location of the center of gravity are updated at a rate of 800/3 approx. equals 267 Hz. In a typical application, a technician would use the center-of-mass output of this instrumentation system as a guide to the manual placement of small weights on the vehicle to shift the center of gravity to a desired horizontal position. Usually, the desired horizontal position is that of the geometric center. Alternatively, this instrumentation system could be used to provide position feedback for a control system that would cause weights to be shifted automatically (see Figure 2) in an effort to keep the center of gravity at the geometric center.

Johnston, Albert S.↗