Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Data for Comparison of Genotyping Assays for Detection of Targeted CRISPR/Cas Mutagenesis in Highly Polyploid Sugarcane

Sugarcane ( Saccharum spp.) is an important biofuel feedstock and a leading source of global table sugar. Saccharum hybrid cultivars are highly polyploid (2n = 100–130), containing large numbers of functionally redundant hom(e)ologs in their genomes. Genome editing with sequence-specific nucleases holds tremendous promise for sugarcane breeding. However, identification of plants with the desired level of co-editing within a pool of primary transformants can be difficult. While DNA sequencing provides direct evidence of targeted mutagenesis, it is cost-prohibitive as a primary screening method in sugarcane and most other methods of identifying mutant lines have not been optimized for use in highly polyploid species. In this study, non-sequencing methods of mutant screening, including capillary electrophoresis (CE), Cas9 RNP assay, and high-resolution melt analysis (HRMA), were compared to assess their potential for CRISPR/Cas9-mediated mutant screening in sugarcane. These assays were used to analyze sugarcane lines containing mutations at one or more of six sgRNA target sites. All three methods distinguished edited lines from wild type, with co-mutation frequencies ranging from 2% to 100%. Cas9 RNP assays were able to identify mutant sugarcane lines with as low as 3.2% co-mutation frequency, and samples could be scored based on undigested band intensity. CE was highlighted as the most comprehensive assay, delivering precise information on both mutagenesis frequency and indel size to a 1 bp resolution across all six targets. This represents an economical and comprehensive alternative to sequencing-based genotyping methods which could be applied in other polyploid species.

Genomics↗

Comparison of genotyping assays for detection of targeted CRISPR/Cas mutagenesis in highly polyploid sugarcane

Sugarcane (Saccharum spp.) is an important biofuel feedstock and a leading source of global table sugar. Saccharum hybrid cultivars are highly polyploid (2n = 100–130), containing large numbers of functionally redundant hom(e)ologs in their genomes. Genome editing with sequence-specific nucleases holds tremendous promise for sugarcane breeding. However, identification of plants with the desired level of co-editing within a pool of primary transformants can be difficult. While DNA sequencing provides direct evidence of targeted mutagenesis, it is cost-prohibitive as a primary screening method in sugarcane and most other methods of identifying mutant lines have not been optimized for use in highly polyploid species. In this study, non-sequencing methods of mutant screening, including capillary electrophoresis (CE), Cas9 RNP assay, and high-resolution melt analysis (HRMA), were compared to assess their potential for CRISPR/Cas9-mediated mutant screening in sugarcane. These assays were used to analyze sugarcane lines containing mutations at one or more of six sgRNA target sites. All three methods distinguished edited lines from wild type, with co-mutation frequencies ranging from 2% to 100%. Cas9 RNP assays were able to identify mutant sugarcane lines with as low as 3.2% co-mutation frequency, and samples could be scored based on undigested band intensity. CE was highlighted as the most comprehensive assay, delivering precise information on both mutagenesis frequency and indel size to a 1 bp resolution across all six targets. This represents an economical and comprehensive alternative to sequencing-based genotyping methods which could be applied in other polyploid species.

60 APPLIED LIFE SCIENCES↗

What the Flicker is going on here? Temporal Light Modulation in Automotive Lighting

Temporal light modulation (TLM), colloquially known as “flicker,” is once again an issue in almost all lighting applications, due to widespread adoption of LED and OLED sources and their driving electronics. A subset of LED/OLED lighting systems delivers problematic TLM, often in specific types of residential, commercial, outdoor, and vehicular lighting. Dashboard displays, touchscreens, marker lights, taillights, daytime running lights, interior lighting, etc. frequently use PWM circuits to achieve different luminances for different times of day and user visual adaptation levels. The resulting TLM waveforms and viewing conditions can result in distraction and disorientation, nausea, cognitive effects, and serious health consequences in some populations, occurring with or without the driver, passenger, or pedestrian consciously “seeing” the flicker. There are three visual responses to TLM: direct flicker, the stroboscopic effect, and phantom array effect (also called the “beads effect”). Metrics for the first two have limitations in both calculation and application. The phantom array effect has no established visibility measure at all, and this is the effect most associated with vehicular flicker because of the widespread use of PWM. Conventional wisdom from the recent past, especially concerning acceptable driver frequency ranges, needs to be reconsidered and replaced with improved guidelines to protect health and comfort. Four principal TLM waveform characteristics affect TLM visibility: frequency, modulation depth, duty cycle, and waveshape. This paper proposes much higher frequency operation if PWM control cannot be avoided; but it may be possible to modify the four principal waveform characteristics together in order to achieve reduced TLM visibility and improved health and comfort.

flicker, TLM, temporal light modulation, automotiv↗

Solar radio spectrum extended to 10 km wavelength

Solar radio spectra for quiet times and radio bursts in the wavelength range from 1 mm to 10 km are presented. Solar nonthermal emission in the range of 100 m to 10 km was monitored by means of long wire antennas connected to multi-channel radiometers in the frequency range 25 kHz to 10 MHz on board the IMP-6 and RAE-1 satellites. Flux densities for very intense type III bursts with intensities ranging from 10 to the -18th to 10 to the -14th W/sq m per Hz with maxima at 330 to 1500 m are shown, and a power-law wavelength distribution function of maximum burst intensities is derived. Intensities of a large type III noise storm are shown to increase with increasing wavelength to a peak near 500 m. The flux densities of both types of burst emission are observed to greatly exceed quiet sun intensities at long wavelengths.

Weber, R. R.↗

Ultrasonic attenuation and velocity in AS/3501-6 graphite/epoxy fiber composite

The ultrasonic group velocity and attenuation were measured as a function of frequency for longitudinal and shear waves in the epoxy matrix (3501-6) and in the principal directions of the unidirectional graphite/epoxy composite (AS/3501-6). Tests were conducted in the frequency ranges 0.25 Mz to 14 MHz and 0.5 Mz to 3 MHz for longitudinal and shear wave modes, respectively. The attenuation increased with frequency for all wave modes, but the group velocity was independent of frequency for all wave modes. The effects of pressure and couplant at the transducer-specimen interface were studied and it was found that for each transducer type there exists a frequency dependent 'saturation pressure' corresponding to the maximum output signal amplitude.

Williams, J. H., Jr.↗

Microwave response of a HEMT photoconductive detector

Interdigitated photoconductive detectors with 5-micron geometry have been fabricated on HEMT material and their optical response characteristics at 820 nm have been examined at dc and in the frequency range of 2-8 GHz. These have been compared with characteristics of similar 1-micron devices on MESFET material. The shapes of the frequency responses were found to differ, but the useful bandwidth of both types of devices was found to be similar.

Claspy, P. C.↗

Feedback instability of the ionospheric resonant cavity

A model is developed that provides a theoretical basis for previous numerical results showing a feedback instability with frequencies characteristic of Alfven travel times within the region of the large increase of Alfven speed above the ionosphere. These results have been extended to arbitrary ionospheric conductivity by developing a numerical solution of the cavity dispersion relation that involves Bessel functions of complex order and argument. It is concluded that the large contrast between the magnetospheric and ionospheric Alfven speed leads to the formation of resonant cavity modes with frequencies ranging from 0.1 to 1 Hz. The presence of the cavity leads to a modification of the reflection characteristics of Alfven waves with frequencies that compare to the cavity's normal modes.

Lysak, Robert L.↗

Frequency-Domain Identification With Composite Curve Fitting

Improved method of parameter identification based on decomposing single wide-band model into two or more component systems in parallel. Each component model predominates in specific frequency range. Wide-band mathematical model of system identified as two narrow-band models: one containing most of information on high-frequency components of dynamics, and one containing most of information on low-frequency components. Applicable to diverse systems, including vibrating structures, electronic circuits, and control systems.

Bayard, David S.↗

High Temperature Acoustic Liner Technology

This paper describes work currently in progress at Langley on liner concepts that employ structures that may be suitable for broadband exhaust noise attenuation in high speed flow environments and at elevated temperatures characteristic of HSCT applications. Because such liners will need to provide about 10 dB suppression over a 2 to 3 octave frequency range, conventional single-degree-of-freedom resonant structures will not suffice. Bulk absorbers have the needed broadband absorption characteristic; however, at lower frequencies they tend to be inefficient.

Parrott, Tony L.↗

Summary Abstract: Vibrations of Ammonia on the Cu (100) Surface

Recently, the TR frequencies for NH3 molecularly adsorbed on Cu(100) have been measured by infrared laser-induced photodesorption using a tunable laser operating in the group frequency range. Additionally, photodesorption, photo-fragmentation, and photoionization has been observed using a CO2 laser in the 10 microns range. In this contribution we report on work in progress where we use quantum chemical methods to analyze the shifts in the NH, frequencies relative to the gas phase upon chemisorption. We also compute the Cu- N stretch vibration, which has been observed experimentally,and the change in the IR intensities associated with chemisorption; this change is insufficient by itself to explain the increased photoionization efficiency observed.

Pettersson, Lars G. M.↗

Changes in gastric myoelectric activity during space flight

The purpose of the present study was to examine postprandial myoelectric activity of the stomach and gastric activity associated with space motion sickness using electrogastrography. Three crewmembers participated in this investigation. Preflight, subjects exhibited normal postprandial responses to the ingestion of a meal. Inflight, crewmembers exhibited an abnormal decrease in the power of the normal gastric slow wave after eating on flight day 1, but had a normal postprandial response by flight day 3. Prior to and during episodes of nausea and vomiting, the electrical activity of the stomach became dysrhythmic with 60-80% of the spectral power in the bradygastric and tachygastric frequency ranges. These findings indicate that gastric motility may be decreased during the first few days of space flight. In addition, changes in the frequency of the gastric slow wave associated with space motion sickness symptoms are consistent with those reported for laboratory-induced motion sickness.

STS Shuttle Project↗

Motion Sickness Treatment Apparatus and Method

Methods and apparatus are disclosed for treating motion sickness. In a preferred embodiment a method of the invention comprises operating eyewear having shutter lenses to open said shutter lenses at a selected operating frequency ranging from within about 3 Hz to about 50 Hz. The shutter lenses are opened for a short duration at the selected operating frequency wherein the duration is selected to prevent retinal slip. The shutter lenses may be operated at a relatively slow frequency of about 4 Hz when the user is in passive activity such as riding in a boat or car or in limited motion situations in a spacecraft. The shutter lenses may be operated at faster frequencies related to motion of the user's head when the user is active.

Reschke, Millard F.↗

Patterned Ferroelectric Films for Tunable Microwave Devices

Tunable microwave devices based on metal terminals connected by thin ferroelectric films can be made to perform better by patterning the films to include suitably dimensioned, positioned, and oriented constrictions. The patterns can be formed during fabrication by means of selective etching processes. If the width of the ferroelectric film in such a device is reduced at one or more locations, then both the microwave field and any applied DC bias (tuning) electric field become concentrated at those locations. The magnitudes of both the permittivity and the dielectric loss of a ferroelectric material are reduced by application of a DC field. Because the concentration of the DC field in the constriction(s) magnifies the permittivity- and loss-reducing effects of the applied DC voltage, the permittivity and dielectric loss in the constriction(s) are smaller in the constriction(s) than they are in the wider parts of the ferroelectric film. Furthermore, inasmuch as displacement current must flow through either the constriction(s) or the low-loss dielectric substrate, the net effect of the constriction(s) is equivalent to that of incorporating one or more low-loss, low-permittivity region(s) in series with the high-loss, high-permittivity regions. In a series circuit, the properties of the low-capacitance series element (in this case, the constriction) dominate the overall performance. Concomitantly, the capacitance between the metal terminals is reduced. By making the capacitance between the metal terminals small but tunable, a constriction increases the upper limit of the frequency range amenable to ferroelectric tuning. The present patterning concept is expected to be most advantageous for devices and circuits that must operate at frequencies from about 4 to about 60 GHz. A constriction can be designed such that the magnitude of the microwave electric field and the effective width of the region occupied by the microwave electric field become functions of the applied DC electric field, so that tunability is enhanced. It should even be possible to design the constriction to obtain a specific tuning-versus-voltage profile.

Miranda, Felix A.↗

Electromagnetic modeling and science reach of DMRadio-m 3

DMRadio-m 3 is an experimental search for dark matter axions. It uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. DMRadio-m 3 is designed to be sensitive to Kim-Shifman-Vainshtein-Zakharov (KSVZ) and Dine-Fischler-Srednicki-Zhitnisky (DFSZ) QCD axion models in the 10–200 MHz (41 neV/𝑐 2 –0.83 μ⁢eV/𝑐 2 ) range, and to axions with 𝑔 𝑎⁢𝛾⁢𝛾 =𝑔 𝑎⁢𝛾⁢𝛾,DFSZ ⁡(30 MHz) =1.87 ×10 −17 GeV −1 over 5–30 MHz as an extended goal. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m 3 , which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of 2 larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a 3⁢𝜎 live scan time of 2.9 years.

Dark matter direct detection↗

Investigation of the dynamic range problem and providing software support for the AOL system

The present scheme for providing system timing for the airborne oceanographic lidar (AOL) system is not completely satisfactory. The possibility of using a digital approach to generate the forty pulses needed to energize the gates leading to the charge digitizers was investigated. The solution in terms of general analog and digital circuitry is straightforward. The crystal oscillator provides a stable frequency source which is used as a clock to the ring counter. The ring counter propagates a pulse from stage one to stage forty. Each of the outputs has an amplifier for isolation. This design is easy to implement in the frequency range up to 50 MHZ. Because a gate pulse width of from about 2 to 6 ns is needed for the AOL system, this dictates an input clock frequency to the shift register of from 100 MHA to 500 MHA. Problems associated with generating pulses in this range of operation are examined and an alternate solution is discussed.

Source record↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Dekametric and hectometric observations of Jupiter from the RAE-1 satellite

Analysis of RAE-1 satellite data has revealed the presence of radio bursts from Jupiter in the frequency range from 4700 kHz to 450 kHz. Variations in the activity with respect to the planet's system III longitude are presented at seven frequencies. A merge of ground-based and satellite-acquired data indicates that the long-sought-for peak in Jupiter's low-frequency flux spectrum occurs at about 8 MHz.

Desch, M. D.↗

On the production mechanism of radio-pulses from large extensive air showers

None of the theories put forward so far to explain the radio emission from cosmic ray showers, has been successful in giving a satisfactory explanation for all the experimental data obtained from various laboratories over the globe. It is apprehended that emission mechanism at low and high frequencies may be quite different. This calls for new theoretical look into the phenomenon. Theoretical as well as the experimental results indicate that the frequency spectrum is rather flat in the frequency range (40 to 60 MHz. Above 80 MHz, the radio emission can be explained with the help of geomagnetic mechanism. But at very low frequency ( 10 MHz), mechanisms other than geomagnetic are involved.

Datta, P.↗