Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Biomass yield in a genetically diverse Miscanthus sacchariflorus germplasm panel phenotyped at five locations in Asia, North America, and Europe

Abstract Miscanthus is a high‐yielding bioenergy crop that is broadly adapted to temperate and tropical environments. Commercial cultivation of Miscanthus is predominantly limited to a single sterile triploid clone of Miscanthus × giganteus , a hybrid between Miscanthus sacchariflorus and M. sinensis. To expand the genetic base of M. × giganteus , the substantial diversity within its progenitor species should be used for cultivar improvement and diversification. Here, we phenotyped a diversity panel of 605 M. sacchariflorus from six previously described genetic groups and 27 M. × giganteus genotypes for dry biomass yield and 16 yield‐component traits, in field trials grown over 3 years at one subtropical location (Zhuji, China) and four temperate locations (Foulum, Denmark; Sapporo, Japan; Urbana, Illinois; and Chuncheon, South Korea). There was considerable diversity in yield and yield‐component traits among and within genetic groups of M. sacchariflorus , and across the five locations. Biomass yield of M. sacchariflorus ranged from 0.003 to 34.0 Mg ha −1 in year 3. Variation among the genetic groups was typically greater than within, so selection of genetic group should be an important first step for breeding with M. sacchariflorus . The Yangtze 2x genetic group (=ssp. lutarioriparius ) of M. sacchariflorus had the tallest and thickest culms at all locations tested. Notably, the Yangtze 2x genetic group's exceptional culm length and yield potential were driven primarily by a large number of nodes (>29 nodes culm −1 average over all locations), which was consistent with the especially late flowering of this group. The S Japan 4x, the N China/Korea/Russia 4x, and the N China 2x genetic groups were also promising genetic resources for biomass yield, culm length, and culm thickness, especially for temperate environments. Culm length was the best indicator of yield potential in M. sacchariflorus . These results will inform breeders' selection of M. sacchariflorus genotypes for population improvement and adaptation to target production environments.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of CFD and Wind-Tunnel Testing at NASA

The debate over when wind-tunnel testing will be replaced by Computational Fluid Dynamics (CFD) comes and goes. More recently, however, the debate has subsided with a more collaborative spirit between practitioners of these two disciplines. Combining these complementary disciplines has led to significant improvements in both as well as better understanding of aero- and fluid dynamics. Also, as CFD codes become more accurate, the need for comparisons with experimental data has increased. New measurement techniques, pressure-sensitive paint and off-body velocity measurements for example, have provided detailed, high-quality data for the comparisons. In-tunnel CFD simulations are also providing more direct comparisons between predicted and measured flows. Given this newenvironment, a concerted effort is now underway to facilitate in-tunnel CFD for the 12 major wind tunnels operated by NASA.The Aerosciences Evaluation and Test Capabilities Portfolio (AETC) manages the major aerodynamic ground-testing facilities within NASA. This group is responsible for the operation, maintenance, and improvement of the wind-tunnel facilities and their capabilities. AETC has recently added a project to integrate CFD and wind-tunnel testing to better support customers of the NASA wind tunnels and to better understand the flow in the wind tunnels themselves. Being able to perform CFD simulations of wind-tunnel models in the wind tunnel environment providesthe cleanest way to assess the accuracy of the simulations relative to test data. AETC plans to provide accurate geometry and guidance to wind-tunnel customers who request it, to facilitate in-tunnel simulations. How this effort got started will be presented along with the status and plans for the project.

CFD↗

Comparison of the PLTEMP code flow instability predictions with measurements made with electrically heated channels for the advanced test reactor.

When the University of Missouri Research Reactor (MURR) was designed in the 1960s the potential for fuel element burnout by a phenomenon referred to at that time as 'autocatalytic vapor binding' was of serious concern. This type of burnout was observed to occur at power levels considerably lower than those that were known to cause critical heat flux. The conversion of the MURR from HEU fuel to LEU fuel will probably require significant design changes, such as changes in coolant channel thicknesses, that could affect the thermal-hydraulic behavior of the reactor core. Therefore, the redesign of the MURR to accommodate an LEU core must address the same issues of fuel element burnout that were of concern in the 1960s. The Advanced Test Reactor (ATR) was designed at about the same time as the MURR and had similar concerns with regard to fuel element burnout. These concerns were addressed in the ATR by two groups of thermal-hydraulic tests that employed electrically heated simulated fuel channels. The Croft (1964), Reference 1, tests were performed at ANL. The Waters (1966), Reference 2, tests were performed at Hanford Laboratories in Richland Washington. Since fuel element surface temperatures rise rapidly as burnout conditions are approached, channel surface temperatures were carefully monitored in these experiments. For self-protection, the experimental facilities were designed to cut off the electric power when rapidly increasing surface temperatures were detected. In both the ATR reactor and in the tests with electrically heated channels, the heated length of the fuel plate was 48 inches, which is about twice that of the MURR. Whittle and Forgan (1967) independently conducted tests with electrically heated rectangular channels that were similar to the tests by Croft and by Walters. In the Whittle and Forgan tests the heated length of the channel varied among the tests and was between 16 and 24 inches. Both Waters and Whittle and Forgan show that the cause of the fuel element burnout is due to a form of flow instability. Whittle and Forgan provide a formula that predicts when this flow instability will occur. This formula is included in the PLTEMP/ANL code.Error! Reference source not found. Olson has shown that the PLTEMP/ANL code accurately predicts the powers at which flow instability occurs in the Whittle and Forgan experiments. He also considered the electrically heated tests performed in the ANS Thermal-Hydraulic Test Loop at ORNL and report by M. Siman-Tov et al. The purpose of this memorandum is to demonstrate that the PLTEMP/ANL code accurately predicts the Croft and the Waters tests. This demonstration should provide sufficient confidence that the PLTEMP/ANL code can adequately predict the onset of flow instability for the converted MURR. The MURR core uses light water as a coolant, has a 24-inch active fuel length, downward flow in the core, and an average core velocity of about 7 m/s. The inlet temperature is about 50 C and the peak outlet is about 20 C higher than the inlet for reactor operation at 10 MW. The core pressures range from about 4 to about 5 bar. The peak heat flux is about 110 W/cm{sup 2}. Section 2 describes the mechanism that causes flow instability. Section 3 describes the Whittle and Forgan formula for flow instability. Section 4 briefly describes both the Croft and the Waters experiments. Section 5 describes the PLTEMP/ANL models. Section 6 compares the PLTEMP/ANL predictions based on the Whittle and Forgan formula with the Croft measurements. Section 7 does the same for the Waters measurements. Section 8 provides the range of parameters for the Whittle and Forgan tests. Section 9 discusses the results and provides conclusions. In conclusion, although there is no single test that by itself closely matches the limiting conditions in the MURR, the preponderance of measured data and the ability of the Whittle and Forgan correlation, as implemented in PLTEMP/ANL, to predict the onset of flow instability for these tests leads one to the conclusion that the same method should be able to predict the onset of flow instability in the MURR reasonably well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LANDSAT Range Resource Information System

A series of test products were developed from LANDSAT data sets for North Central Texas that paralleled the needs of ranchers, technical personnel, and the media. The products and evaluation questionnaires were mailed to approximately 150 ranchers who had reported an interest in evaluating the information systems. In addition to the rancher group, fourteen media people and a thirty-three member group in the agri business/technical community was also chosen to receive test products. The group responses are analyzed. Examples of the test products and associated questionnaires are included.

Boyd, W. E.↗

Future Liver Remnant Indocyanine Green Plasma Clearance Rate as a Predictor of Post-hepatectomy Liver Failure After Portal Vein Embolization

PurposeTo evaluate the utility of future liver remnant plasma clearance rate of indocyanine green (ICGK-F) for predicting post-hepatectomy liver failure (PHLF) compared with percentage future liver remnant volume-to-total liver volume ratio (%FLR) after portal vein embolization (PVE).Materials and MethodsPVE procedures in 20 patients (15 patients underwent PVE with absolute ethanol; 5 patients with gelatin particles) from 2010 to 2017 were analyzed. %FLR = future liver remnant volume (ml)/[total liver volume (ml) − tumor volume (ml)] × 100; ICGK-F = plasma clearance rate of indocyanine green (ICGK) × %FLR/100 were calculated before and after PVE. PHLF was categorized according to the criteria of the International Study Group of Liver Surgery. For predicting PHLF, we compared the ICGK-F and %FLR after PVE between the grade A PHLF group and the non-grade A PHLF (grades B and C) group.ResultsAll PVE procedures were successful. While the ICGK-F of the grade A PHLF group (median 0.073, n = 16) was about twice that of the non-grade A PHLF group (median 0.043, n = 4), showing a significant difference (Mann–Whitney U test: P = 0.002), there was no significant difference in %FLR between the grade A PHLF group and the non-grade A PHLF group (Mann–Whitney U test: P = 0.335).ConclusionICGK-F was significantly higher in the grade A PHLF group than in the non-grade A PHLF group (grades B and C), and ICGK-F was more useful for predicting PHLF than %FLR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reexamination of the Edge Crack Torsion Test for Determining the Mode III Delamination Toughness of Laminated Composites

The edge crack torsion (ECT) test is reexamined to address two primary concerns with this method. The first of these relates to inconsistencies in the data reduction procedure that was originally proposed and is most commonly used to compute the mode III interlaminar fracture toughness, G(sub IIIc), from the experimental data. The second relates to the observation that plies neighboring the preimplanted insert in the standard ECT layup are unable to contain initiation and growth of intralaminar cracks, and that growth of these cracks contributes to errors in the apparent values of G(sub IIIc). To address these issues, an alternative data reduction technique, which uses a polynomial expression to represent the ECT specimen’s compliance versus crack length relation, is proposed. The accuracy and potential drawbacks of this expression are investigated using FE simulations. Next, seven groups of ECT specimens are fabricated and tested. Each of these groups contains specimens with preimplanted inserts that are bounded by plies at different +q and -q orientations. The seven groups consist of values of q that vary from 0° to 90° in 15° increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except those for which q equals 15° or 30°. However, values of G(sub IIIc) measured using specimens with these two ply orientations were not equal and, for q = 30°, the values of G(sub IIIc) that were obtained were not completely independent of initial starter crack length. Potential issues accounting for these observations and other challenges associated with measuring G(sub IIIc) using the ECT test are discussed.

Polymer matrix composites↗

QM-8 final performance evaluation report: SEALS, volume 4

The Space Shuttle Redesigned Solid Rocket Motor (RSRM) static test of Qualification Motor-8 (QM-8) was conducted. The QM-8 test article was the fifth full-scale, full-duration test, and the third qualification motor to incorporate the redesigned case field joint and nozzle-to-case joint. This was the second static test conducted in the T-97 test facility, which is equipped with actuators for inducing external side loads to a 360 degree external tank (ET) attach ring during test motor operation, and permits heating/cooling of an entire motor. The QM-8 motor was cooled to a temperature which ensured that the maximum propellant mean bulk temperature (PMBT) of 40 F was achieved at firing. All test results are not included, but rather, the performance of the metal case, field joints, and nozzle-to-case joint is addressed. The involvement is studied of the Structural Applications and Structural Design Groups with the QM-8 test which includes: assembly procedures of the field and nozzle-to-case joints, joint leak check results, structural test results, and post-test inspection evaluations.

Nelsen, L. V.↗

PrismTech Data Distribution Service Java API Evaluation

My internship duties with Launch Control Systems required me to start performance testing of an Object Management Group's (OMG) Data Distribution Service (DDS) specification implementation by PrismTech Limited through the Java programming language application programming interface (API). DDS is a networking middleware for Real-Time Data Distribution. The performance testing involves latency, redundant publishers, extended duration, redundant failover, and read performance. Time constraints allowed only for a data throughput test. I have designed the testing applications to perform all performance tests when time is allowed. Performance evaluation data such as megabits per second and central processing unit (CPU) time consumption were not easily attainable through the Java programming language; they required new methods and classes created in the test applications. Evaluation of this product showed the rate that data can be sent across the network. Performance rates are better on Linux platforms than AIX and Sun platforms. Compared to previous C++ programming language API, the performance evaluation also shows the language differences for the implementation. The Java API of the DDS has a lower throughput performance than the C++ API.

Riggs, Cortney↗

Research and development for Onboard Navigation (ONAV) ground based expert/trainer system: Preliminary test plan

The test plan for the onboard navigation (ONAV) expert system is described. Levels of testing are identified and the contributing role of each level for ensuring reliability is described. Also, the objectives of each type of test are identified and a summary of the test methods and the type of testing environment to be used is included. The ONAV expert system testing effort utilizes a multi-level verification approach. Five levels of testing are performed in essentially a serial manner: (1) individual rules, (2) ordered and unordered functional groups, (3) interface rules, (4) system tests, and (5) user tests. The intent is to catch the full range of both programming errors common to traditional programming and those errors characteristic of expert systems including factbase organization and inference engine interactions.

Bochsler, Daniel C.↗

Habituation of motion sickness in the cat

Thirty femal cats were subjected to a motion sickness stimulus in three series of tests. A series consisted of five tests given biweekly, weekly, or daily. Each test consisted of 30 min of stimulation followed by 1 min of rest, and series were separated by a period of not less than 14 d. Retching was the dependent variable. No habituation (reduction in the incidence of retching) was found with biweekly testing but pronounced habituation was observed with weekly and daily testing. The 30 cats were divided evenly into high and low susceptibility groups based on the results of the biweekly tests. The rate of habituation was the same for the two susceptibility groups in both the weekly and daily series.

Crampton, George H.↗

High Reynolds Number Testing of the NATO AVT-298 SWiFT Configuration at the National Transonic Facility

A high Reynolds number wind tunnel test of the NATO AVT-298 Swept Wing Flow Test (SWiFT) configuration was conducted in the National Transonic Facility at the NASA Langley Research Center during the summer of 2023. The SWiFT research model geometry has relevance to both blended/hybrid wing body (BWB/HWB) and unmanned combat aerial vehicle (UCAV) configurations, and the test campaign was the culmination of an international collaboration under the NATO AVT-298 research task group. The main objectives of the test were to investigate Reynolds number scaling effects on low-speed stability & control characteristics and to examine the onset and progression of flow separation on the wings particularly near the wing crank. Force & moment and surface pressure data were acquired at Mach numbers from 0.2 to 0.8, Reynolds numbers from 2.5 to 34 million, angles of attack from -3 to 20 degrees, and sideslip angles from -10 to 10 degrees. Boundary layer transition detection techniques utilizing static pressure taps, unsteady pressure transducers, and sublimating chemicals were used on the model in a free/natural transition state or a forced transition state using trip dots. Pressure sensitive paint was used to obtain a global surface pressure profile on the model and an advanced laser velocimetry technique was used to obtain velocity measurements in the wake downstream of the wing crank. The results from the test showed clear Reynolds number scaling effects on the maximum lift coefficient and pitching moment coefficient at Mach 0.2, while also capturing significant hysteresis effects. The data acquired from the test will ultimately help improve computational aerodynamic analysis and design tools for application to future BWB-type vehicle configurations.

NATO AVT-298↗

Surface Pressure Results for the NATO AVT-298 SWiFT Configuration in the National Transonic Facility

A high Reynolds number wind tunnel test of the Swept Wing Flow Test (SWiFT) configuration was conducted in the National Transonic Facility at the NASA Langley Research Center during the summer of 2023. The test campaign was the culmination of an international collaboration under the NATO AVT-298 research task group. The main objective of the test was to investigate Reynolds number scaling effects on the low-speed stability & control characteristics of the SWiFT model. Surface pressure results corroborate the force & moment results and help to provide more insight into the observed flow behavior. The effect of angle of attack and Reynolds number on the low-speed surface pressure results are analyzed particularly around the leading edge of the model. The onset and progression of flow separation on the wings particularly near the wing crank is also investigated, as well as the cause of an observed double-stall behavior. Finally, the transonic results showed a slight forward movement of the shock location with decreased shock strength as Reynolds number was increased. The data acquired from the test will ultimately help improve computational aerodynamic analysis and design tools for application to future BWB-type vehicle configurations.

NATO AVT-298↗

High Reynolds Number Testing of the NATO AVT-298 SWiFT Configuration at the National Transonic Facility

A high Reynolds number wind tunnel test of the NATO AVT-298 Swept Wing Flow Test (SWiFT) configuration was conducted in the National Transonic Facility at the NASA Langley Research Center during the summer of 2023. The SWiFT research model geometry has relevance to both blended/hybrid wing body (BWB/HWB) and unmanned combat aerial vehicle (UCAV) configurations, and the test campaign was the culmination of an international collaboration under the NATO AVT-298 research task group. The main objectives of the test were to investigate Reynolds number scaling effects on low-speed stability & control characteristics and to examine the onset and progression of flow separation on the wings particularly near the wing crank. Force & moment and surface pressure data were acquired at Mach numbers from 0.2 to 0.8, Reynolds numbers from 2.5 to 34 million, angles of attack from -3 to 20 degrees, and sideslip angles from -10 to 10 degrees. Boundary layer transition detection techniques utilizing static pressure taps, unsteady pressure transducers, and sublimating chemicals were used on the model in a free/natural transition state or a forced transition state using trip dots. Pressure sensitive paint was used to obtain a global surface pressure profile on the model and an advanced laser velocimetry technique was used to obtain velocity measurements in the wake downstream of the wing crank. The results from the test showed clear Reynolds number scaling effects on the maximum lift coefficient and pitching moment coefficient at Mach 0.2, while also capturing significant hysteresis effects. The data acquired from the test will ultimately help improve computational aerodynamic analysis and design tools for application to future BWB-type vehicle configurations.

BWB/HWB↗

Surface Pressure Results for the NATO AVT-298 SWiFT Configuration in the National Transonic Facility

A high Reynolds number wind tunnel test of the Swept Wing Flow Test (SWiFT) configuration was conducted in the National Transonic Facility at the NASA Langley Research Center during the summer of 2023. The test campaign was the culmination of an international collaboration under the NATO AVT-298 research task group. The main objective of the test was to investigate Reynolds number scaling effects on the low-speed stability & control characteristics of the SWiFT model. Surface pressure results corroborate the force & moment results and help to provide more insight into the observed flow behavior. The effect of angle of attack and Reynolds number on the low-speed surface pressure results are analyzed particularly around the leading edge of the model. The onset and progression of flow separation on the wings particularly near the wing crank is also investigated, as well as the cause of an observed double-stall behavior. Finally, the transonic results showed a slight forward movement of the shock location with decreased shock strength as Reynolds number was increased. The data acquired from the test will ultimately help improve computational aerodynamic analysis and design tools for application to future BWB-type vehicle configurations.

NATO AVT-298↗

An Application of CFD to Guide Forced Boundary-Layer Transition at Subsonic and Transonic Speeds for a Lambda-Wing Configuration

A hybrid transition trip-dot sizing and placement test technique was extended to support recent experimental research on a moderately-swept hybrid wing-body Uninhabited Combat Air Vehicle configuration under study in a North Atlantic Treaty Organization Applied Vehicle Technology task group. The approach combines traditional test techniques with Computational Fluid Dynamics. The application had three-dimensional boundary layers that were simulated with either fully turbulent or mixed laminar-turbulent flow models using established Reynolds-averaged Navier-Stokes methods. Forced transition effectiveness was verified experimentally using sublimating chemicals during low-speed and transonic wind tunnel tests. Assessments were performed between tripped low Reynolds number data and un-tripped high Reynolds number data. The hybrid test technique is based on fundamental flow physics and as such could be applicable to other configurations.

UCAV↗

An Application of CFD to Guide Forced Boundary-Layer Transition at Subsonic and Transonic Speeds for a Lambda-Wing Configuration

A hybrid transition trip-dot sizing and placement test technique was extended to support recent experimental research on a moderately-swept hybrid wing-body Uninhabited Combat Air Vehicle configuration under study in a North Atlantic Treaty Organization Applied Vehicle Technology task group. The approach combines traditional test techniques with Computational Fluid Dynamics. The application had three-dimensional boundary layers that were simulated with either fully turbulent or mixed laminar-turbulent flow models using established Reynolds-averaged Navier-Stokes methods. Forced transition effectiveness was verified experimentally using sublimating chemicals during low-speed and transonic wind tunnel tests. Assessments were performed between tripped low Reynolds number data and un-tripped high Reynolds number data. The hybrid test technique is based on fundamental flow physics and as such could be applicable to other configurations.

Wind tunnel test technique↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗