Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Tangential 2-D Edge Imaging for GPI and Edge/Impurity Modeling

Nova Photonics, Inc. has a collaborative effort at the National Spherical Torus Experiment (NSTX). This collaboration, based on fast imaging of visible phenomena, has provided key insights on edge turbulence, intermittency, and edge phenomena such as edge localized modes (ELMs) and multi-faceted axisymmetric radiation from the edge (MARFE). Studies have been performed in all these areas. The edge turbulence/intermittency studies make use of the Gas Puff Imaging diagnostic developed by the Principal Investigator (Ricardo Maqueda) together with colleagues from PPPL. This effort is part of the International Tokamak Physics Activity (ITPA) edge, scrape-off layer and divertor group joint activity (DSOL-15: Inter-machine comparison of blob characteristics). The edge turbulence/blob study has been extended from the current location near the midplane of the device to the lower divertor region of NSTX. The goal of this effort was to study turbulence born blobs in the vicinity of the X-point region and their circuit closure on divertor sheaths or high density regions in the divertor. In the area of ELMs and MARFEs we have studied and characterized the mode structure and evolution of the ELM types observed in NSTX, as well as the study of the observed interaction between MARFEs and ELMs. This interaction could have substantial implications for future devices where radiative divertor regions are required to maintain detachment from the divertor plasma facing components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution functional photoacoustic tomography of breast cancer

Purpose: To evaluate the feasibility of functional photoacoustic tomography (fPAT) for high resolution detection and characterization of breast cancer and to demonstrate for the first time quantitative hemoglobin concentration and oxygen saturation images of breasts that were formed with model-based reconstruction of tomographic photoacoustic data. Methods: The study was HIPAA compliant and was approved by the university institutional review board. Written informed consents were obtained from all the participants. Ten cases, including six cancer and four healthy (mean age = 50 yr; age range = 41–66 yr), were examined. Functional images of breast tissue including absolute total hemoglobin concentration (Hb{sub T}) and oxygen saturation (StO{sub 2}%) were obtained by fPAT and cross validated with magnetic resonance imaging (MRI) readings and/or histopathology. Results: Hb{sub T} and StO{sub 2}% maps from all six pathology-confirmed cancer cases (60%) show clear detection of tumor, while MR images indicate clear detection of tumor for five of six cancer cases; one small tumor was read as near-complete-resolution by MRI. The average Hb{sub T} and StO{sub 2}% value of suspicious lesion area for the cancer cases was 61.6 ± 18.9 μM/l and 67.5% ± 5.2% compared to 25.6 ± 7.4 μM/l and 65.2% ± 3.8% for background normal tissue. Conclusions: fPAT has the potential to be a significant add-on in breast cancer detection and characterization as it provides submillimeter resolution functional images of breast lesions.

60 APPLIED LIFE SCIENCES↗

A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment

Purpose: To design and develop a real-time electronic portal imaging device (EPID)-based delivery verification system for dynamic intensity modulated radiation therapy (IMRT) which enables detection of gross treatment delivery errors before delivery of substantial radiation to the patient.Methods: The system utilizes a comprehensive physics-based model to generate a series of predicted transit EPID image frames as a reference dataset and compares these to measured EPID frames acquired during treatment. The two datasets are using MLC aperture comparison and cumulative signal checking techniques. The system operation in real-time was simulated offline using previously acquired images for 19 IMRT patient deliveries with both frame-by-frame comparison and cumulative frame comparison. Simulated error case studies were used to demonstrate the system sensitivity and performance.Results: The accuracy of the synchronization method was shown to agree within two control points which corresponds to approximately ∼1% of the total MU to be delivered for dynamic IMRT. The system achieved mean real-time gamma results for frame-by-frame analysis of 86.6% and 89.0% for 3%, 3 mm and 4%, 4 mm criteria, respectively, and 97.9% and 98.6% for cumulative gamma analysis. The system can detect a 10% MU error using 3%, 3 mm criteria within approximately 10 s. The EPID-based real-time delivery verification system successfully detected simulated gross errors introduced into patient plan deliveries in near real-time (within 0.1 s).Conclusions: A real-time radiation delivery verification system for dynamic IMRT has been demonstrated that is designed to prevent major mistreatments in modern radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep image reconstruction for background subtraction in heavy-ion collisions

Jet reconstruction in an ultrarelativistic heavy-ion collision suffers from a notoriously large, fluctuating thermal background. Traditional background‐subtraction methods struggle to remove this soft background while preserving the jet's hard substructure. In this Letter, we present DeepSub, a machine-learning-based approach for full-event background‐subtraction. DeepSub utilizes a model based on Swin Transformer layers to denoise jet images and disentangle hard jets from the heavy-ion background. DeepSub significantly outperforms existing subtraction techniques by reproducing key jet observables such as jet 𝑝 T and mass, and substructure observables such as girth and the energy correlation function, at the subpercent to percent level. As such, DeepSub paves the way for precision heavy-ion measurements in hitherto inaccessible kinematic regimes.

Qureshi, Umar Sohail [Stanford University, CA (Uni↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗

Quantitative PET Imaging Using A Comprehensive Monte Carlo System Model

We present the complete image generation methodology developed for the RatCAP PET scanner, which can be extended to other PET systems for which a Monte Carlo-based system model is feasible. The miniature RatCAP presents a unique set of advantages as well as challenges for image processing, and a combination of conventional methods and novel ideas developed specifically for this tomograph have been implemented. The crux of our approach is a low-noise Monte Carlo-generated probability matrix with integrated corrections for all physical effects that impact PET image quality. The generation and optimization of this matrix are discussed in detail, along with the estimation of correction factors and their incorporation into the reconstruction framework. Phantom studies and Monte Carlo simulations are used to evaluate the reconstruction as well as individual corrections for random coincidences, photon scatter, attenuation, and detector efficiency variations in terms of bias and noise. Finally, a realistic rat brain phantom study reconstructed using this methodology is shown to recover >; 90% of the contrast for hot as well as cold regions. The goal has been to realize the potential of quantitative neuroreceptor imaging with the RatCAP.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ultrafast Bragg coherent diffraction imaging of epitaxial thin films using deep complex-valued neural networks

Abstract Domain wall structures form spontaneously due to epitaxial misfit during thin film growth. Imaging the dynamics of domains and domain walls at ultrafast timescales can provide fundamental clues to features that impact electrical transport in electronic devices. Recently, deep learning based methods showed promising phase retrieval (PR) performance, allowing intensity-only measurements to be transformed into snapshot real space images. While the Fourier imaging model involves complex-valued quantities, most existing deep learning based methods solve the PR problem with real-valued based models, where the connection between amplitude and phase is ignored. To this end, we involve complex numbers operation in the neural network to preserve the amplitude and phase connection. Therefore, we employ the complex-valued neural network for solving the PR problem and evaluate it on Bragg coherent diffraction data streams collected from an epitaxial La 2-x Sr x CuO 4 (LSCO) thin film using an X-ray Free Electron Laser (XFEL). Our proposed complex-valued neural network based approach outperforms the traditional real-valued neural network methods in both supervised and unsupervised learning manner. Phase domains are also observed from the LSCO thin film at an ultrafast timescale using the complex-valued neural network.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural Characterization and Simulation of High Temperature Inelastic Deformation and Fracture of Al-Li 2070

A combined experimental and simulation investigation is carried out to characterize the high temperature deformation behavior of a recently developed Al-Li alloy, AA2070, over a temperature range including typical forging temperatures. Focus is placed on providing explanations for the temperature-dependent plastic and fracture behavior observed for this material using macroscale tensile tests, microscale imaging and analysis, and physics-based micromechanical modeling. It is shown that AA2070 experiences non-monotonic elongation to failure with a rise in temperature. Detailed fractography and microstructural analysis, including dynamic recrystallization analysis, provide insight into this interesting and practically useful behavior. In addition, a validated crystal plasticity model is called upon to explain the unique texture observed in the necked region of the ductile tensile specimen. The insights provided by this investigation will allow improved design of high temperature forming operations for AA2070 and similar alloys which can extend the application of third generation Al-Li alloys.

36 MATERIALS SCIENCE↗

Street context of various demographic groups in their daily mobility

Abstract We present an urban science framework to characterize phone users’ exposure to different street context types based on network science, geographical information systems (GIS), daily individual trajectories, and street imagery. We consider street context as the inferred usage of the street, based on its buildings and construction, categorized in nine possible labels. The labels define whether the street is residential, commercial or downtown, throughway or not, and other special categories. We apply the analysis to the City of Boston, considering daily trajectories synthetically generated with a model based on call detail records (CDR) and images from Google Street View. Images are categorized both manually and using artificial intelligence (AI). We focus on the city’s four main racial/ethnic demographic groups (White, Black, Hispanic and Asian), aiming to characterize the differences in what these groups of people see during their daily activities. Based on daily trajectories, we reconstruct most common paths over the street network. We use street demand (number of times a street is included in a trajectory) to detect each group’s most relevant streets and regions. Based on their street demand, we measure the street context distribution for each group. The inclusion of images allows us to quantitatively measure the prevalence of each context and points to qualitative differences on where that context takes place. Other AI methodologies can further exploit these differences. This approach presents the building blocks to further studies that relate mobile devices’ dynamic records with the differences in urban exposure by demographic groups. The addition of AI-based image analysis to street demand can power up the capabilities of urban planning methodologies, compare multiple cities under a unified framework, and reduce the crudeness of GIS-only mobility analysis. Shortening the gap between big data-driven analysis and traditional human classification analysis can help build smarter and more equal cities while reducing the efforts necessary to study a city’s characteristics.

Salgado, Ariel (ORCID:0000000177015372)↗

Overview of the KSTAR experiments and future plan

The Korea Superconducting Tokamak Advanced Research (KSTAR) device has recently entered a new phase of operation following the installation of a tungsten mono-block divertor, providing a unique platform to investigate high-performance, long-pulse plasma scenarios for future reactors. The 2023–2024 experimental campaigns demonstrated significant progress in commissioning the tungsten divertor, developing plasma operation scenarios, and achieving real-time control. Comparative studies revealed increased core radiation losses and associated performance degradation relative to the carbon divertor environment. Alleviation strategies, such as optimized neutral beam injection timing, boron powder seeding, and impurity control through gas puffing, were shown to reduce tungsten accumulation and extend high-performance phases, including record H-mode operation exceeding 100 s. International collaboration enabled the first demonstration of high poloidal beta scenarios with an internal transport barrier on KSTAR. Advances in control included upgraded real-time resonant magnetic perturbation schemes and disruption forecasting. Furthermore, divertor detachment control using a new surrogate-model-based approach with real-time radiation imaging demonstrated active impurity and heat flux management. Supported by enhanced heating, current drive, and diagnostic systems, these achievements offer valuable insights into tungsten impurity behavior, transport physics, and control strategies for future reactors including ITER. Planned upgrades toward a full-tungsten wall and ITER-aligned real-time plasma control will further establish KSTAR as a leading experimental platform for developing operational scenarios required to achieve steady-state, burning plasma conditions.

KSTAR↗

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics↗

Electrode Mesoscale as a Collection of Particles: Coupled Electrochemical and Mechanical Analysis of NMC Cathodes

Battery electrodes are composed of polydisperse particles and a porous, composite binder domain. These materials are arranged into a complex mesostructure whose morphology impacts both electrochemical performance and mechanical response. We present image-based, particle-resolved, mesoscale finite element model simulations of coupled electrochemical-mechanical performance on a representative NMC electrode domain. Beyond predicting macroscale quantities such as half-cell voltage and evolving electrical conductivity, studying behaviors on a per-particle and per-surface basis enables performance and material design insights previously unachievable. Voltage losses are primarily attributable to a complex interplay between interfacial charge transfer kinetics, lithium diffusion, and, locally, electrical conductivity. Mesoscale heterogeneities arise from particle polydispersity and lead to material underutilization at high current densities. Particle-particle contacts, however, reduce heterogeneities by enabling lithium diffusion between connected particle groups. While the porous composite binder domain (CBD) may have slower ionic transport and less available area for electrochemical reactions, its high electrical conductivity makes it the preferred reaction site late in electrode discharge. Mesoscale results are favorably compared to both experimental data and macrohomogeneous models. This work enables improvements in materials design by providing a tool for optimization of particle sizes, CBD morphology, and manufacturing conditions.

42 ENGINEERING↗

System support documentation: IDIMS FUNCTION AMOEBA

A listing is provided for AMOEBA, a clustering program based on a spatial-spectral model for image data. The program is fast and automatic (in the sense that no parameters are required), and classifies each picture element into classes which are determined internally. As an IDIMS function, no limit on the size of the image is imposed.

Bryant, J.↗

Least squares restoration of multi-channel images

In this paper, a least squares filter for the restoration of multichannel imagery is presented. The restoration filter is based on a linear, space-invariant imaging model and makes use of an iterative matrix inversion algorithm. The restoration utilizes both within-channel (spatial) and cross-channel information as constraints. Experiments using color images (three-channel imagery with red, green, and blue components) were performed to evaluate the filter's performance and to compare it with other monochrome and multichannel filters.

Chin, Roland T.↗

The Formation of Life-sustaining Planets in Extrasolar Systems

The spatial exploration is providing us a large quantity of information about the composition of the planets and satellites crusts. However, most of the experiences that are proposed in the guides of activities in Planetary Geology are based exclusively on the images utilization: photographs, maps, models or artistic reconstructions [1,2]. That things help us to recognize shapes and to deduce geological processes, but they says us little about the materials that they are implicated. In order to avoid this dicotomy between shapes and materials, we have designed an experience in the one which, employing of rocks and landscapes of our geological environment more next, the pupils be able to do an exercise of compared planetology analyzing shapes, processes and material of several planetary bodies of the Solar System.

Chambers, J. E.↗

Early Results from the Solar-Minimum 2019 Total Solar Eclipse

We observed the 2 July 2019 total solar eclipse with a variety of imaging and spectroscopic instruments recording from three sites in mainland Chile: on the centerline at La Higuera, from the Cerro Tololo Inter-American Observatory, and from La Serena, as well as from a chartered flight at peak totality in mid-Pacific. Our spectroscopy monitored Fe X, Fe XIV, and Ar X lines, and we imaged Ar X with a Lyot filter adjusted from its original H-alpha bandpass. Our composite imaging has been compared with predictions based on modeling using magnetic-field measurements from the pre-eclipse month. Our time-differenced sites will be used to measure motions in coronal streamers.

Jay M Pasachoff↗