Search NASA⌕ Search

SEARCH · Search NASA

Results for “load test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Concept of Operations and Checkout Testing for Green Propellant Loading System

Low toxicity propulsion, or Green Propulsion, is increasingly being considered for use on spacecraft following the successful demonstration during the Green Propellant Infusion Mission in 2020. One of these missions is JPL’s Lunar Flashlight (LF), a polar orbiting 12U CubeSat that uses lasers to investigate water ice deposits on the moon’s surface. For the past 3 years, Marshall Space Flight Center has developed the ASCENT propulsion system for LF, along with a green propellant loading system to service the spacecraft. The Propellant Loading System (PLS) is composed of 3 mobile carts designed to operate at a variety of launch facilities and handle the 2 primary green propellants, LMP-103S and ASCENT. In anticipation of LF propellant loading, the PLS was recently installed into an MSFC facility for checkout operations. In the winter of 2020, a simulant spacecraft was successfully loaded with water, pressurized to flight pressure, and drained back into the system. These checkouts drove the concept of operations for final spacecraft loading and informed minor modifications to the PLS for better operability. Additionally, a parallel effort was started to design the next generation of the PLS based on water flow lessons learned. With water flow testing complete, propellant checkouts and wet dress rehearsals with spacecraft pathfinder hardware are anticipated to begin in late Spring 2021.

Green Propulsion↗

Integral Battery Power Limiting Circuit for Intrinsically Safe Applications

A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the switch and the inductor configuration. In the fault condition, both the resistor and the inductor react immediately. The resistor reacts by allowing more current to flow and dropping the voltage. Initially, the inductor reacts by dropping the voltage, and then by not allowing the current to change. When the comparator detects the drop in voltage, it opens the switch, thus preventing any further current flow. The inductor alone is not sufficient protection, because after the voltage drop has settled, the inductor would then allow the current to change, in this example, the current would be 3.7 A. In the fault condition, the resistor is flowing 200 mA until the fuse blows (anywhere from 1 ms to 100 s), while the switch and inductor combination is flowing about 2 A test current while monitoring for the fault to be corrected. Finally, as an additional safety feature, the circuit can be configured to hold the switch opened until both the load and source are disconnected.

Burns, Bradley M.↗

Helicopter blade dynamic loads measured during performance testing of two scaled rotors

A test to determine the performance differences between the 27-percent-scale models of two rotors for the U.S. Army AH-64 helicopter was conducted in the Langley 14- by 22-Foot Subsonic Tunnel. One rotor, referred to as the baseline rotor, simulated the geometry and dynamic characteristics of the production baseline rotor, and the other rotor, referred to as the advanced rotor, was designed to have improved hover performance. During the performance test, the dynamic pitch-link forces and blade bending and torsion moments were also measured. Dynamic data from the forward flight investigation are reduced and presented. The advanced blade set was designed to have dynamic characteristics similar to those of the baseline rotor so that test conditions would not be limited by potential rotor instability and blade resonances, and so that the measured performance increments could be considered to be due purely to aerodynamic causes. Data show consistent trends with advance ratio for both blade sets with generally higher oscillatory loads occurring for the advanced blade set when compared with the baseline blade set.

Berry, John D.↗

Static calibration for measurement of loads in wind tunnel tests on Shuttle surface tiles

A description is given of the procedures used for the static calibrations of the Coe (1981) sensor array to determine normal force, pitching moment, and rolling moment from the ensemble of sensor outputs. The use of independent data to confirm the validity of the calibration is also described. Two methods are used in calibrating the Coe sensors. In the first, calibration loads and readings are arranged in matrix form and are assumed to be related in a linear fashion. In the second, each Coe sensor reading is regarded as a sum of contributions from each of the calibration loads. It is shown that the Coe load sensors, in conjunction with either of two data analysis methods, can be used to determine the forces and moments experienced by a Shuttle TPS tile.

Rummler, D. R.↗

Design, fabrication, testing and delivery of a prototype self-locking actuator

The design, fabrication, and testing of a prototype self-locking actuator capable of producing an axial force of 44.5 kN are reported. The actuator passed the initial proof test successfully, however, when the no-load rate test was attempted, the actuator would not extend from the fully contracted position.

Dever, J. E.↗

Modified Mode-I Cracked Sandwich Beam (CSB) Fracture Test

Five composite sandwich panels were fabricated using vacuum assisted resin transfer molding (VARTM). Four of these panels had E-glass/vinylester facesheets and one had carbon/epoxy facesheets. The sandwich panels had different density PVC foam cores. The four E-glass panels had core densities of 80, 100, 130, 200 kg/cu m. The sandwich with carbon/epoxy 3 facesheets had a core with density of 100 kg/cu m. Fracture tests were conducted using a modified Cracked Sandwich Beam (CSB) test configuration. Load displacement curves were obtained for loading and unloading of the specimens during crack growth. Various increments of crack growth were monitored. Critical Strain Energy Release Rates (SERR) were determined from the tests using the area method. The critical values of SERR can be considered the fracture toughness of the sandwich material. The fracture toughness ranged 367 J/sq m to 1350 J/sq m over the range of core densities. These results are compared to the Mode-I fracture toughness of the PVC foam core materials and values obtained for foam-cored sandwiches using the TSD specimen. Finite-element analyses (FEA) were performed for the test configuration and Strain Energy Release Rates were calculated using the Virtual Crack Closure Technique (VCCT). The SERR values determined from the FEA were scaled to the fracture loads, or critical loads, obtained from the modified CSB tests. These critical loads were in close agreement with the test values.

Smith, S. A.↗

Experimental investigation of strains in fabric under biaxial and shear forces.

The paper defines the experimental phase of an objective to obtain the mechanical characteristics and coefficients required by the generalized form of Hooke's law for nylon-polyurethane-coated fabric. Test specimens were cylindrical fabric sleeves and were loaded in axial tension by an Instron, in hoop tension by pressurizing, and in shear by a torquing fixture. An extensive amount of strain data is included for a wide combination of the three membrane loads. The tests indicate highly nonlinear stress-strain characteristics of the fabric and a strong dependency on all three membrane loads.

Alley, V. L., Jr.↗

An instrumented fastener for shear force measurements in joints

A preliminary investigation has been conducted on instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double-splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Results from calibration tests show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double-splice joints. Tests were also conducted with three instumented fasteners installed in a typical double-splice joint. The test results showed that the load distribution between individual fasteners is dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, J. W.↗

Crack Growth Behavior in the Threshold Region for High Cycle Fatigue Loading

This presentation describes results obtained from a research project conducted at the NASA Johnson Space Center (JSC) that was jointly supported by the FAA Technical Center and JSC. The JSC effort was part of a multi-task FAA program involving several U.S. laboratories and initiated for the purpose of developing enhanced analysis tools to assess damage tolerance of rotorcraft and aircraft propeller systems. The research results to be covered in this presentation include a new understanding of the behavior of fatigue crack growth in the threshold region. This behavior is important for structural life analysis of aircraft propeller systems and certain rotorcraft structural components (e.g., the mast). These components are often designed to not allow fatigue crack propagation to exceed an experimentally determined fatigue crack growth threshold value. During the FAA review meetings for the program, disagreements occurred between the researchers regarding the observed fanning (spread between the da/dN curves of constant R) in the threshold region at low stress ratios, R. Some participants believed that the fanning was a result of the ASTM load shedding test method for threshold testing, and thus did not represent the true characteristics of the material. If the fanning portion of the threshold value is deleted or not included in a life analysis, a significant penalty in the calculated life and design of the component would occur. The crack growth threshold behavior was previously studied and reported by several research investigators in the time period: 1970-1980. Those investigators used electron microscopes to view the crack morphology of the fatigue fracture surfaces. Their results showed that just before reaching threshold, the crack morphology often changed from a striated to a faceted or cleavage-like morphology. This change was reported to have been caused by particular dislocation properties of the material. Based on the results of these early investigations, a program was initiated at JSC to repeat these examinations on a number of aircraft structural alloys that were currently being tested for obtaining fatigue crack growth properties. These new scanning electron microscope (SEM) examinations of the fatigue fracture faces confirmed the change in crack morphology in the threshold crack tip region. In addition, SEM examinations were further performed in the threshold crack-tip region before breaking the specimens open (not done in the earlier published studies). In these examinations, extensive crack forking and even 90-degree crack bifurcations were found to have occurred in the final threshold crack-tip region. The forking and bifurcations caused numerous closure points to occur that prevented full crack closure in the threshold region, and thus were the cause of the fanning at low-R values. Therefore, we have shown that the fanning behavior was caused by intrinsic dislocation properties of the different alloy materials and were not the result of a plastic wake that remains from the load-shedding test phase. Also, to accommodate the use of da/dN data which includes fanning at low R-values, an updated fanning factor term has been developed and will be implemented into the NASGRO fatigue crack growth software. The term can be set to zero if it is desired that the fanning behavior is not be modeled for particular cases, such as when fanning is not a result of the intrinsic properties of a material.

Forman, Royce G.↗

Full-scale crash-test evaluation of two load-limiting subfloors for general aviation airframes

Three six place, low wing, twin engine general aviation airplane test specimens were crash tested at the Langley Impact Dynamics Research Facility under controlled free flight conditions. One structurally unmodified airplane was the base line specimen for the test series. The other two airplanes were structurally modified to incorporate load limiting (energy absorbing) subfloor concepts into the structure for full scale crash test evaluation and for comparison with the unmodified airplane test results. Typically, the lowest floor accelerations, the lowest anthropomorphic dummy responses, and the least seat crushing of standard and load limiting seats occurred in the airplanes modified with load limiting subfloors, wherein the greatest structural crushing of the subfloor took place. The better performing of the two load limiting subfloor concepts reduced the peak airplane floor accelerations to -25g to -30g as compared with approximately -40g to -55g for the unmodified airplane structure.

Carden, H. D.↗

Crack growth under spectrum loading: A crack closure model

A concept based on the crack-closure phenomenon was developed to replace random load spectra with constant amplitude loading in both analysis and tests. The maximum load and the crack opening load in the constant amplitude loading are chosen to be equal to those for the spectrum, so that both crack growth mode and the crack length at failure are equivalent to those under random load spectra. The number of cycles of constant- amplitude loading is chosen so that the amount of crack growth is equal to that due to a given sequence or block of the random spectrum loading. The concept was tested experimentally after predicting the equivalent number of constant-amplitude cycles for six different random load sequences. The agreement between predictions and test results was good.

Elber, W.↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simplified approach for creep damage and remaining life calculation for materials surveillance in advanced reactors

High temperature reactor materials will experience a combination of mechanical degradation caused by creep and fatigue and environmental degradation caused by neutron irradiation and, in some cases, exposure to corrosive coolants. A materials surveillance program is one option for ensuring the safe, reliable operation of key reactor components under these conditions. Such a program would monitor the degradation in key material properties over time, using this data to predict how changes in the material properties affect components performance. This could then be used to make plant operational decisions and support eventual plant license extensions. Past work de-scribes such a material surveillance program based on passively actuated mechanical test articles that impose creep-fatigue type loading on test materials driven only by changes in temperature, for example those experienced by components under standard operating cycles. This report focuses on two aspects of the proposed material surveillance program: how to design the test articles to mimic the mechanical response of the corresponding component and how to use ex-situ test data to deter-mine the amount of damaged experienced by the test article (and hence the corresponding compo-nent) in service. Specifically, this report derives and validated simplified methods for both tasks, replacing earlier, more complicated approaches based on simulating the test article response and finding the best specimen design or current damage via complex numerical optimization. The sim-plified methods for each task developed here can be implemented in spreadsheet software and are simple enough for practical use in future operating plants. This report derives the methods (one for sizing and two options for damage inference), verifies the simplified approaches versus more so-phisticated methods, and compares the results of applying the simplified methods to previous re-sults using the complex numerical optimization approach. The report also provides a worked sam-pled problem applying the simplified techniques to a realistic high temperature reactor component.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗