Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Machine Learning-Based Anomaly Detection for Load Forecasting Under Cyberattacks

Accurate load forecasting can create both economic and reliability benefits for power system operators. However, the cyberattack on load forecasting may mislead operators to make unsuitable operational decisions for the electricity delivery. To effectively and accurately detect these cyberattacks, this paper develops a machine learning-based anomaly detection (MLAD) methodology. First, load forecasts provided by neural networks are used to reconstruct the benchmark and scaling data by using the k-means clustering. Second, the cyberattack template is estimated by the naive Bayes classification based on the cumulative distribution function and statistical features of the scaling data. Finally, the dynamic programming is utilized to calculate both the occurrence and parameter of one cyberattack on load forecasting data. Here, a widely used symbolic aggregation approximation method is compared with the developed MLAD method. Numerical simulations on the publicly load data show that the MLAD method can effectively detect cyberattacks for load forecasting data with relatively high accuracy. Also, the robustness of MLAD is verified by thousands of attack scenarios based on Monte Carlo simulation.

97 MATHEMATICS AND COMPUTING↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cathode Loading Effect on Sulfur Utilization in Lithium–Sulfur Battery

The Lithium-Sulfur (Li-S) battery is under intensive research in recent years due to its potential to provide higher energy density and lower cost than the current state-of-the-art lithium-ion battery technology. To meet cost target for transportation application, high sulfur loading up to 8 mAh cm -2 is predicted by modeling. In this work, we have investigated the sulfur loading effect on the galvanostatic charge/discharge cycling performance of Li-S cells with theoretical sulfur loading ranging from 0.5 mAh cm -2 to 7.5 mAh cm -2 . We found that the low sulfur utilization of electrodes with sulfur loading of > 3.0 mAh cm-2 is due to their inability to deliver capacities at the 2.1V voltage plateau, which corresponds to the conversion of soluble Li 2 S 4 to insoluble Li 2 S 2 /Li 2 S. This electrochemical conversion process recovers to deliver the expected sulfur utilization after several activation cycles for electrodes with sulfur loading up to 4.5 mAh cm -2 . For electrodes with 7.0 mAh cm -2 loading, no sulfur utilization recovery was observed for 100 cycles. The root cause of this phenomenon is elucidated by SEM/EDS and EIS investigation. Carbon interlayer cell design and low rate discharge activation are demonstrated to be effective mitigation methods.

25 ENERGY STORAGE↗

Optimal Discrete Net-Load Balancing in Smart Grids with High PV Penetration

Mitigating supply-demand mismatch is essential for smooth power grid operation. Traditionally, load curtailment techniques such as demand response have been used for this purpose. However, these cannot be the only component of a net-load balancing framework for smart grids with high PV penetration. These grids sometimes exhibit supply surplus, causing overvoltages. Currently, these are mitigated using voltage manipulation techniques such as Volt-Var Optimizations, which are computationally expensive, thereby increasing the complexity of grid operations. Taking advantage of recent technological developments that enable rapid selective connection of PV modules of an installation to the grid, we develop a unified net-load balancing framework that performs both load and solar curtailment. We demonstrate that when the available curtailment values are discrete, this problem is NP-hard and we develop bounded approximation algorithms. Our algorithms produce fast solutions, given the tight timing constraints required for grid operation, while ensuring that practical constraints such as fairness, network capacity limits, and so forth are satisfied. We also develop an online algorithm that performs net-load balancing using only data available for the current interval. Using both theoretical analysis and practical evaluations, we show that our net-load balancing algorithms provide solutions that are close to optimal in a small amount of time.

14 SOLAR ENERGY↗

Applying Graph Partitioning Methods in Measurement-Based Dynamic Load Balancing

Load imbalance can lead to wasted CPU hours especially when running on a large number of processors. Achieving the best parallel efficiency for a program requires optimal load balancing which is a NP-hard problem. Charm++, a migratable objects based programming model, provides a measurement-based dynamic load balancing frame work. This paper explores the use of graph partitioning algorithms, traditionally used for partitioning physical domains/meshes, for measurement based dynamic load balancing of parallel applications. In particular, we present repartitioning methods developed in a graph partitioning toolbox called Scotch that consider the previous mapping to minimize migration costs. We also discuss a new imbalance reduction algorithm for graphs with irregular load distributions. We compare several load balancing algorithms using a micro-benchmark and the NAS BT multi-zone bench mark. New algorithms developed in Scotch lead to better performance compared to other existing partitioners, both in terms of the application execution time and fewer number of objects migrated.

97 MATHEMATICS AND COMPUTING↗

Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

Unlike sub-metering, which requires that individual loads are equipped with their own meters, nonintrusive load monitors (NILM) use algorithms to discern the individual loads from a single metering point. Although a number of these technologies are now commercially available to utilities and homeowners, with several more to become available in the coming years, it is not yet understood how accurately these technologies can disaggregate a home’s electrical load. Pacific Northwest National Laboratory (PNNL) and its partners at the Northwest Energy Efficiency Alliance (NEEA) have identified and acquired six of these technologies and will be testing them in the PNNL Lab Homes as well as the owner-occupied Residential Test Bed operated by NEEA. As a result of this testing, PNNL and NEEA will evaluate the selected NILMs against a repeatable test protocol so that their accuracy can be compared across NILM technologies. In the field deployment in the NEEA Test Bed Homes, PNNL and NEEA will evaluate the real-world accuracy of the NILMs responding to dynamic loads. To evaluate the accuracy of NILM technologies regardless of their intended application, a standardized test protocol is required that applies representative loads and establishes consistent metrics against which the NILM can be evaluated and compared. To establish this standardized test protocol, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

NILM↗

A gas-loading system for LANL two-stage gas guns

A novel gas loading system was designed for the specific application of remotely loading high purity gases into targets for gas-gun driven plate impact experiments. The high purity gases are loaded into well-defined target configurations to obtain Hugoniot states in the gas phase at greater than ambient pressures.The small volume of the gas samples is challenging, as slight changing in the ambient temperature result in measurable pressure changes. Therefore, the ability to load a gas gun target and continually monitor the sample pressure prior to firing provides the most stable and reliable target fielding approach. We present the design and evaluation of a gas loading system built for the LANL 50 mm bore two-stage light gas gun. Targets for the gun are made of 6061 Al or OFHC Cu, and assembled to form a gas containment cell with a volume of approximately 1.38 cc. The compatibility of materials was a major consideration in the design of the system, particularly for its use with corrosive gases. Piping and valves are stainless steel with wetted seals made from Kalrez® and Teflon®. Preliminary testing was completed to ensure proper flow rate and that the proper safety controls were in place. The system has been used to successfully load Ar, Kr, Xe, and anhydrous ammonia with purities of up to 99.999 percent. The design of the system and example data from the plate impact experiments will be shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Planetary Load Sharing in Three-Point Mounted Wind Turbine Gearboxes: A Design and Test Comparison

This work compares the planetary load-sharing characteristics of wind turbine gearboxes supported by cylindrical roller bearings (CRBs) and preloaded tapered roller bearings (TRBs) when subjected to rotor moments. Planetary bearing loads were measured in field-representative dynamometer tests and compared to loads predicted by finite-element models. Preloaded TRBs significantly improved load sharing. In pure torque conditions, the upwind planet bearing load in the gearbox with preloaded TRBs was only 14% more than the assumed load compared to 47% more for the gearbox with CRBs. Consequently, the predicted fatigue life of the complete set of planetary bearings for the gearbox with preloaded TRBs is 3.5 times greater than that of the gearbox with CRBs.

17 WIND ENERGY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

Quantifying the Opportunity Limits of Automatic Residential Electric Load Shaping

Electric utility residential demand response programs typically reduce load a few times a year during periods of peak energy use. In the future, utilities and consumers may monetarily and environmentally benefit from continuously shaping load by alternatively encouraging or discouraging the use of electricity. One way to shape load and introduce elasticity is to broadcast forecasts of dynamic electricity prices that orchestrate electricity supply and demand in order to maximize the efficiency of conventional generation and the use of renewable resources including wind and solar energy. A binary control algorithm that influences the on and off states of end uses was developed and applied to empirical time series data to estimate price-based instantaneous opportunities for shedding and adding electric load. To overcome the limitations of traditional stochastic methods in quantifying diverse, non-Gaussian, non-stationary distributions of observed appliance behaviour, recent developments in wavelet-based analysis were applied to capture and simulate time-frequency domain behaviour. The performance of autoregressive and spectral reconstruction methods was compared, with phase reconstruction providing the best simulation ensembles. Results show spatiotemporal differences in the amount of load that can be shed and added, which suggest further investigation is warranted in estimating the benefits anticipated from the wide-scale deployment of continuous automatic residential load shaping. Empirical data and documented software code are included to assist in reproducing and extending this work.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

33 ADVANCED PROPULSION SYSTEMS↗

The influence of wind veer and drivetrain flexibility on fatigue loading for large floating wind turbines

To reduce costs, offshore wind turbines are expected to be designed with significantly increased rotor diameters. Larger turbines become more flexible and span a larger portion of the atmospheric boundary layer. With these changes, the validity of traditional modeling assumptions should be investigated. This work challenges two common assumptions: (1) that the drivetrain can be considered rigid (except in torsion) and does not couple with the rotor and tower and 2) that wind directional change with height (veer) does not greatly influence the fatigue damage in the tower, blades and drivetrain. Two large semi-submersible floating wind turbines are considered: a 15 and a 22 MW reference turbine. Both use direct-drive generators. Aero-hydro-servo-elastic simulations are performed using OpenFAST, with drivetrain bending flexibility and main bearing response implemented in the coupled analysis. The turbines are subjected to a set of load cases at below-, near- and above-rated mean wind speeds, assembled based on the 3 km Norwegian reanalysis (NORA3) hourly wind and wave hindcast data for Utsira Nord, off the coast of Norway. In each load case, conditions with and without veer are simulated to evaluate the influence of veer on damage equivalent loads (DELs) of the turbine tower, blades and main bearings. Further, these load cases are applied to evaluate the influence of drivetrain flexibility on aero-elastic turbine response. The results indicate that, depending on the veer gradient, mean wind speed, operating regime and turbine size, veer can be very important for tower-top DELs and the fluctuations of main bearing radial loads, while main bearing and blade-root flapwise DELs are less affected. Considering these specific load cases and turbine models, drivetrain flexibility is found to significantly influence tower-top DELs of the largest turbine: the tower-top fore-aft and torsional damage equivalent moments of the 22 MW turbine are reduced by more than 20 % at near-rated wind speeds when the drivetrain is modeled as flexible.

17 WIND ENERGY↗

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determinethe number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging towardutility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetrationscenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-Term Load Forecasting Error Distributions and Implications for Renewable Integration Studies: Preprint

Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of the day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.

17 WIND ENERGY↗