Search NASASearch

SEARCH · Search NASA

Results for “low-earth orbit (LEO)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

912 records · Page 32

The Active Asteroids Citizen Science Program: Overview and First Results

Abstract We present the Citizen Science program Active Asteroids and describe discoveries stemming from our ongoing project. Our NASA Partner program is hosted on the Zooniverse online platform and launched on 2021 August 31, with the goal of engaging the community in the search for active asteroids—asteroids with comet-like tails or comae. We also set out to identify other unusual active solar system objects, such as active Centaurs, active quasi-Hilda asteroids (QHAs), and Jupiter-family comets (JFCs). Active objects are rare in large part because they are difficult to identify, so we ask volunteers to assist us in searching for active bodies in our collection of millions of images of known minor planets. We produced these cutout images with our project pipeline that makes use of publicly available Dark Energy Camera data. Since the project launch, roughly 8300 volunteers have scrutinized some 430,000 images to great effect, which we describe in this work. In total, we have identified previously unknown activity on 15 asteroids, plus one Centaur, that were thought to be asteroidal (i.e., inactive). Of the asteroids, we classify four as active QHAs, seven as JFCs, and four as active asteroids, consisting of one main-belt comet (MBC) and three MBC candidates. We also include our findings concerning known active objects that our program facilitated, an unanticipated avenue of scientific discovery. These include discovering activity occurring during an orbital epoch for which objects were not known to be active, and the reclassification of objects based on our dynamical analyses.

Astronomy & Astrophysics

Electromagnetic Melt Processing: A Pathway to New Additive Manufacturing Technologies for Functional High-Performance Thermoplastics

In this study, we apply the electromagnetic (EM) melt processing of thermoplastics on an innovative EM field-driven powder bed fusion additive manufacturing (AM) concept for high-performance functional parts: Selective Microwave Melting/Sintering (SMM/SMS). This technique leverages the EM susceptibility of carbon nanotube-coated polymer micro-pellets to achieve rapid, localized heating and powder fusion. Thus, selective microwave melting (SMM) was used to fabricate multilayer specimens made of recycled polyphenylene sulfide (rPPS) and carbon nanotubes (CNTs). The resulting SMM specimens exhibited very good interlayer integrity, localized fusion at pellet boundaries, and tolerable residual porosity, indicating effective fusion and acceptable consolidation. CNT-rich interphases were retained after irradiation, generating anisotropic electrically active network pathways and enabling conductivity enhancement at low filler content. At only 1.0 wt% CNT, the specimens exhibited electrical conductivity approximately three orders of magnitude higher than neat rPPS. Dynamic mechanical analysis showed improved viscoelastic response relative to neat rPPS, while tensile testing confirmed that the SMM-processed specimens retained practical mechanical integrity despite localized voids. These results demonstrate that SMM can effectively consolidate EM susceptible thermoplastic powder beds while preserving their segregated conductive networks. This may become a scalable route for producing multifunctional thermoplastic parts with low filler loadings, tunable anisotropy, and structured materials and parts. Overall, the findings suggest that EM field-based AM can help overcome key limitations of conventional thermoplastic processing by enabling scalable, energy-efficient fabrication of nanostructured composites and expanding AM to a broader range of resins, including high-performance thermoplastics with customized functional properties.

Powder bed fusion

Science questions for the Magellan continuing mission

Magellan has completed two mapping cycles around the planet Venus, returning high resolution synthetic aperture images and altimetry data of over 95 percent of the planet's surface. Venus is dominated by low lying volcanic plains with an impact crater population indicating an average surface age of about 500 million years. Highland regions either tend to be characterized by volcanic shield complexes and rifting or by complex ridged terrain. Successful as the primary mission of Magellan has been, significant scientific questions remain to be addressed with imaging and gravity data that will be collected over the next several years.

Saunders, R. S.

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

Thrust Chamber Thermal Barrier Coating Techniques

Methods for applying thermal barrier coatings to the hot-gas side wall of rocket thrust chambers in order to significantly reduce the heat transfer in high heat flux regions has been the focus of technology efforts for many years. A successful technique developed by NASA-Lewis that starts with the coating on a mandrel and then builds the thrust chamber around it by electroforming appropriate materials is described. This results in a smooth coating with exceptional adherence, as was demonstrated in hot fire rig tests. The low cycle fatigue life of chambers with coatings applied in this manner was increased dramatically compared to uncoated chambers.

Richard J Quentmeyer

A strong and ductile Super Kovar alloy via fully coherent nanoprecipitates

Emerging high-precision technologies demand materials with exceptional dimensional stability and mechanical robustness, as even microscopic thermomechanical deformation can cause functional failure. However, a fundamental trilemma exists: High strength, ductility, and low thermal expansion are mutually exclusive, as strengthening-induced lattice distortions compromise the spin-lattice coupling, which is essential for low thermal expansion. Here, we overcome this trilemma by designing “Super Kovar,” an Fe-Ni-Co-Al-Ta alloy, featuring fully coherent nanoprecipitates. It unifies a 1.0-gigapascal ultimate tensile strength and ∼39% elongation with a Kovar-grade thermal expansion of 3.81 × 10−6 K−1 (100 to 410 K). The key is a dense dispersion of L12 nanoprecipitates that form an almost strain-free coherent interface with the ferromagnetic matrix. Beyond providing precipitation strengthening, these coherent interfaces suppress intrinsic phonons of nanoprecipitates via elastic coupling while avoiding magnetic domain pinning to preserve the Invar effect of the matrix. This reduces the thermal expansion of the precipitates by 56% and achieves a fourfold enhancement in the strength-ductility product, establishing a paradigm for dimensionally stable, ultrastrong alloys.

Yu, Chengyi [University of Science and Technology

Review of European Microgravity Measurements

AA In a French/Russion cooperation, CNES developed a microgravity detection system for analyzing the Mir space station micro-g-environment for the first time. European efforts to characterize the microgravity (1/9) environment within a space laboratory began in the late seventies with the design of the First Spacelab Mission SL-1. Its Material Science Double Rack was the first payload element to carry its own tri-axial acceleration package. Even though incapable for any frequency analysis, the data provided a wealth of novel information for optimal experiment and hardware design and operations for missions to come. Theoretical investigations under ESA contract demonstrated the significance of the detailed knowledge of micro-g data for a thorough experiment analysis. They especially revealed the high sensitivity of numerous phenomena to low frequency acceleration. Accordingly, the payloads of the Spacelab missions D-1 and D-2 were furnished with state-of-the-art detection systems to ensure frequency analysis between 0.1 and 100 Hz. The Microgravity Measurement Assembly (MMA) of D-2 was a centralized system comprising fixed installed as well as mobile tri-axial packages showing real-time data processing and transmission to ground. ESA's free flyer EURECA carried a system for continuous measurement over the entire mission. All EURECA subsystems and experimental facilities had to meet tough requirements defining the upper acceleration limits. In a French/Russion cooperation, CNES developed a mi crogravity detection system for analyzing the Mir space station micro-g-environment for the first time. An approach to get access to low frequency acceleration between 0 and 0.02 Hz will be realized by QSAM (Quasi-steady Acceleration Measurement) on IML-2, complementary to the NASA system Spacelab Acceleration Measurement System SAMS. A second flight of QSAM is planned for the Russian free flyer FOTON.

H Hamacher

Development of a High Force Thermal Latch

This paper describes the preliminary development of a high force thermal latch (HFTL). The HFTL has one moving part which is restrained in the latched position by a low melting temperature or fusible metal alloy. When heated the fusible alloy flows to a receiving chamber and in so doing at first releases the tension load in the latch bolt and later releases the bolt itself. The HFTL can be used in place of pyrotechnically activated spacecraft release devices in those instances where the elimination of both pyrotechnic shock-loading and rapid strain-energy release take precedence over the near instantaneous release offered by ordnance initiated devices.

William D Nygren

Bifurcation of Rotating Liquid Drops: Results From USML-1 Experiments in Space

Experiments on rotational bifurcation of liquid drops, in which the drops were levitated and spun using acoustic fields in a low-gravity environment, were conducted during the first United States Microgravity Laboratory (USML-1) Space Shuttle flight. The experiments have successfully resolved the discrepancies existing between the previous experimental results and the theoretical predictions. In the case of a spherical drop, for which theory exists, the results agree well with the predictions. In the case of flattened drops, the experiments have established a family of curves, with the spherical drop as the limiting case.

T G Wang

Trace benzene capture by decoration of structural defects in metal–organic framework materials

Abstract Capture of trace benzene is an important and challenging task. Metal–organic framework materials are promising sorbents for a variety of gases, but their limited capacity towards benzene at low concentration remains unresolved. Here we report the adsorption of trace benzene by decorating a structural defect in MIL-125-defect with single-atom metal centres to afford MIL-125-X (X = Mn, Fe, Co, Ni, Cu, Zn; MIL-125, Ti 8 O 8 (OH) 4 (BDC) 6 where H 2 BDC is 1,4-benzenedicarboxylic acid). At 298 K, MIL-125-Zn exhibits a benzene uptake of 7.63 mmol g −1 at 1.2 mbar and 5.33 mmol g −1 at 0.12 mbar, and breakthrough experiments confirm the removal of trace benzene (from 5 to <0.5 ppm) from air (up to 111,000 min g −1 of metal–organic framework), even after exposure to moisture. The binding of benzene to the defect and open Zn(II) sites at low pressure has been visualized by diffraction, scattering and spectroscopy. This work highlights the importance of fine-tuning pore chemistry for designing adsorbents for the removal of air pollutants.

Chemistry

The impact of metastability on the high-pressure behavior of cerium

The structures adopted by solids under pressure are often assumed to reflect thermodynamic equilibrium, yet in many materials phase selection is strongly influenced by kinetic pathways and microstructural inheritance. Elemental cerium (Ce) exemplifies this challenge, with decades of conflicting reports describing different high-pressure crystal structures emerging under nominally identical conditions. Here we use neutron diffraction from large ( ~ 60 mm 3 ) sample volumes to follow the structural evolution in ultra-high-purity Ce during controlled pressure-temperature cycling between 85 and 295 K and up to 8 GPa. We find that the crystal structure formed at high pressure depends on the compression pathway: slow compression ( ~ 0.25 GPa hr −1 ) at room temperature favors an orthorhombic phase (α'), whereas slow ( ~ 0.25 GPa hr −1 ) and also moderately faster ( ~ 0.5 GPa hr −1 ) compression at low temperature stabilizes a pure monoclinic phase (α"). The low-temperature phase persists metastably over a wide temperature range but transforms irreversibly upon heating above ~ 280 K, or modest pressure cycling. Remarkably, the lower-pressure γ phase remains trapped far beyond the expected stability field, persisting to the highest pressures studied. These observations show that phase selection in Ce is governed by kinetics and microstructural memory rather than equilibrium thermodynamics or sample morphology alone, establishing path dependence as a defining feature of its high-pressure behavior.

Ridley, Christopher J. [Oak Ridge National Laborat

Probing and Tuning Spatiotemporal pH Evolution in Aqueous Zinc Ion Batteries

Aqueous zinc-ion batteries (AZIBs) offer a combination of safety and low cost, but they suffer from dynamic pH fluctuations that drive parasitic reactions and capacity fading. In this review, we report the current mechanistic understanding of the dynamic pH evolution across the electrolyte-electrode interface and its role in triggering interphase instability. We summarize advanced strategies to regulate pH, including electrolyte engineering, electrode surface modification, and interphase construction. We further discuss current methods for probing pH dynamics and outline potential future approaches for gaining deeper mechanistic and design insights.

Zheng, Xueli [SLAC]

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber

Core-Centering of Compound Drops in Capillary Oscillations: Observations on USML-1 Experiments in Space

Using the existing inviscid theories, an attempt is made to explain the centering of the oscillating liquid shell. Experiments on liquid shells and liquid-core compound drops were conducted using acoustic levitation, in a low-gravity environment during a Space Shuttle flight. It was observed that their inner and outer interfaces became concentric when excited into capillary oscillations. Using the existing inviscid theories, and attempt is made to explain the centering of the oscillating liquid shell. It is concluded that viscosity needs to be considered in order to provide a realistic description of the centering process.

T G Wang

P-band Antenna Array for NASA's Space Exploration Synthetic Aperture Radar (SESAR) Instrument

A dual-polarized, wideband, lightweight P-band (435 MHz) antenna element and array for spaceborne radar applications has been developed for NASA’s SESAR (Space Exploration Synthetic Aperture Radar) instrument for planetary synthetic aperture radar (SAR) applications. The antenna array is based on lightweight, low-profile antenna elements that form the building blocks of configurable “array panels” that can in turn be used to build larger arrays consisting of multiple panels. The element design combines a novel, mostly planar conductor antenna element geometry with a robust lightweight composite material construction.

Synthetic Aperture Radar

JWST Reveals Spectral Tracers of Recent Surface Modification on Europa

Europa has been modified by a variety of geologic processes, exposing internally-derived materials that are heavily irradiated by charged particles trapped in Jupiter’s magnetosphere. Prior spectral analysis of H2O ice on Europa relied on low signal-to-noise data at wavelengths >2.5 µm, limiting assessment of a 3.1 µm Fresnel peak that is diagnostic of exposed crystalline ice. We report new measurements of H2O ice spectral features using high signal-to-noise data collected by the NIRSpec spectrograph (1.48 – 5.35 µm) on the James Webb Space Telescope. These data reveal a narrow 3.1 µm crystalline H2O ice Fresnel peak, which is primarily located at southern latitudes in Tara and Powys Regiones. Our analysis indicates that crystalline ice exposed in these low-latitude regiones is likely sustained by ongoing thermal (re)crystallization outpacing charged particle amorphization of the top ∼10 µm of Europa’s regolith over short timescales (<15 days). We also measured H2O ice features centered near 1.5 µm, 1.65 µm, and 2.0 µm, and a broad 3.6 µm H2O continuum peak, which are all stronger at northern latitudes, in contrast to the 3.1 µm Fresnel peak identified at southern latitudes. These results support the hypothesis that H2O ice in Europa’s regolith is vertically stratified, with amorphous ice grains dominating its exposed surface, except in Tara and Powys Regiones. We also find that a previously detected 4.38 µm 13CO2 feature is present almost exclusively at southern latitudes in Tara and Powys Regiones, likely derived from an internal source of carbon-bearing material.

Surface processes (2116)

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen