High-order finite-volume methods for hyperbolic conservation laws on mapped multiblock grids
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We introduce the design and capabilities of a resistive heated diamond anvil cell that can be used for side diffraction at simultaneous high pressure and high temperature. The device can be used to study lattice-preferred orientations in polycrystalline samples up to temperatures of 1100 K and pressures of 36 GPa. Capabilities of the instrument are demonstrated with preliminary results on the development of textures in the bcc, fcc, and hcp polymorphs of iron during a nonhydrostatic compression experiment at simultaneous high pressure and high temperature.
Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizing continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).
This protocol defines a chiller measure as a project that directly impacts equipment within the boundary of a chiller plant. A chiller plant encompasses a chiller - or multiple chillers - and associated auxiliary equipment. This protocol primarily covers electric-driven chillers and chiller plants. It does not include thermal energy storage and absorption chillers fired by natural gas or steam, although a similar methodology may be applicable to these chilled water system components.
Given new regulations, increased complexity in the market, and the general shift from CFLs to LEDs, this evaluation protocol was updated in 2017 to shift the focus of the protocols toward LEDs and away from CFLs and to resolve evaluation uncertainties affecting residential lighting incentive programs.
Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.
No abstract prepared.
Not provided.
Abstract Pillared Sn‐MWW (Sn‐MWW(SP)‐SSE) was prepared through a solid‐state‐exchange (SSE) route. The pillared structure was inherited from pillared B‐MWW, and Sn was inserted in the framework by boron leaching and solid‐state‐exchange with tin tetrachloride pentahydrate. The Sn‐MWW(SP)‐SSE with framework Sn sites exhibits Lewis acidity and good catalytic performance for the Baeyer–Villiger oxidation, and mono‐ and disaccharide isomerizations.
The role of physically restrained, noncrystalline sulfur species in rechargeable lithium–sulfur batteries is examined by electrochemical and high‐resolution material characterizations. Carbon–sulfur composites are created by melting and sublimation of sulfur in an isochoric reactor via the autogenic process. These noncrystalline sulfur cathodes demonstrate a high specific capacity of ≈1000 Ah kg −1 after 100 cycles with a gravimetric current of 557 A kg −1 . Interestingly, this high‐performance sulfur allotrope lacks a long‐range structural order: high‐resolution X‐ray diffraction, performed at the Advanced Photon Source, indicates the lack of crystalline (i.e., orthorhombic or monoclinic) sulfur in the nanoscale domain. Electrochemical and material characterizations suggest that noncrystalline sulfur is a consequence of synthesis and not necessarily evidence of electrochemical efficacy. Rather, a high rate capacity depends on sulfur distribution, in turn, controlled by synthesis pathway. At higher sulfur content, the performance of carbon–sulfur composites is limited by the available surface area in which crystalline sulfur coincides with reduced gravimetric capacity and greater charge transport impedance, suggesting suboptimal sulfur containment.
Covering a light-emitting diode (LED) with quantum dots (QDs) can produce a broad spectrum of white light. However, current techniques for applying QDs to LEDs suffer from a high density of defects and a non-uniform distribution of QDs, which respectively diminish the efficiency and quality of emitted light. Oak Ridge National Laboratory (ORNL) has the unique capability to thermally anneal QD structures at extremely high power densities for very short durations. This process, called pulse thermal processing (PTP), reduces the number of point defects while maintaining the size and shape of the original QD nanostructure. The efficiency of the QD wavelength conversion layer is improved without altering the emission spectrum defined by the size distribution of the quantum dot nanoparticles. As a result, the current research uses a thermal model to predict annealing temperatures during PTP and demonstrates up to a 300% increase in photoluminescence for QDs on passive substrates
The wind resource assessment community has long had the goal of reducing the bias between wind plant pre-construction energy yield assessment (EYA) and the observed annual energy production (AEP). This comparison is typically made between the 50% probability of exceedance (P50) value of the EYA and the long-term corrected operational AEP (hereafter OA P50), and is known as the P50 bias. The industry has critically lacked an independent analysis of bias reduction investigated across multiple consultants to identify the greatest sources of uncertainty and variance in the EYA process and the best opportunities for uncertainty reduction. The present study addresses this gap by benchmarking consultant methodologies against each other and against operational data at a scale not seen before in industry collaborations. We consider data from 10 wind plants and evaluate discrepancies between eight consultancies in the steps taken from estimates of gross to net energy. Consultants tend to overestimate the gross energy produced at the turbines and then compensate by further overestimating downstream losses, leading to a mean P50 bias near zero, still with significant variability among the individual wind plants. Within our data sample, we find that consultant estimates of all loss categories, except environmental losses, tend to reduce the project-to-project variability of the P50 bias. The disagreement between consultants, however, remains flat throughout the addition of losses. Finally, we find that differences in consultants’ estimates of project performance can lead to differences up to $10/MWh in the levelized cost of energy for a wind plant.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.