Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface

Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: The water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.

61 RADIATION PROTECTION AND DOSIMETRY↗

Research on integration of visual and motion cues for flight simulation and ride quality investigation

Vestibular perception and integration of several sensory inputs in simulation were studied. The relationship between tilt sensation induced by moving fields and those produced by actual body tilt is discussed. Linearvection studies were included and the application of the vestibular model for perception of orientation based on motion cues is presented. Other areas of examination includes visual cues in approach to landing, and a comparison of linear and nonlinear wash out filters using a model of the human vestibular system is given.

Young, L. R.↗

Visual cueing aids for rotorcraft landings

The present study used a rotorcraft simulator to examine descents-to-hover at landing pads with one of three approach lighting configurations. The impact of simulator platform motion upon descents to hover was also examined. The results showed that the configuration with the most useful optical information led to the slowest final approach speeds, and that pilots found this configuration, together with the presence of simulator platform motion, most desirable. The results also showed that platform motion led to higher rates of approach to the landing pad in some cases. Implications of the results for the design of vertiport approach paths are discussed.

Johnson, Walter W.↗

A Simulation Model for Local Harmonic Motion Monitoring of Focused Ultrasound Surgery

A computational model for local harmonic motion (LHM) imaging-based monitoring of high-intensity focused ultrasound surgery (FUS) is presented. LMH technique is based on a focused ultrasound radiation force excitation, which induces local mechanical vibrations at the focal region. These pulse-echo imaged vibrations are then used to estimate the mechanical properties of the sonication region. LHM has been proven to be feasible for FUS monitoring because changes in the material properties during the coagulation affect the measured displacements. The presented model includes separate models to simulate acoustic fields, sonication induced temperature elevation and mechanical vibrations, and pulse-echo imaging of the induced motions. These simulation models are based on Rayleigh integral, finite element, and spatial impulse response methods. Simulated temperature rise and vibration amplitudes have been compared with in vivo rabbit experiments with noninvasive MRI thermometry.

60 APPLIED LIFE SCIENCES↗

Simulation-based characterization of the variability of earthquake risk to buildings in the near-field

Recent advancements in high performance computing platforms and computational workflow for regional-scale simulations are enabling unprecedented modeling of fault-to-structure earthquake processes. Regional simulations resolving ground motions at frequencies relevant to engineered systems are becoming computationally viable and provide a new capability to improve understanding of the geographical distribution and intensity of risk to buildings and critical infrastructure. As computational capabilities advance, it is essential to move beyond illustrative single rupture realizations for scenario earthquake events towards the development of a full suite of rupture realizations that appropriately characterize the range of risk to building systems. The work described in this article investigates the application of a suite of fault rupture realizations with the objective of assessing near-fault, site-specific seismic demand variability for building structures. A representative high-performance regional-scale computational model is utilized to execute ground motion and building response simulations based on 18 kinematic rupture realizations of an M7 strike-slip scenario earthquake. The fault rupture models for the scenario earthquake are created by systematically perturbing the hypocenter location and stochastically generating rupture parameters (slip, rise time, rake angle) to represent a breadth of ground motion intensities resulting from the spatial and temporal variabilities of an earthquake rupture process. The resulting seismic demand variability for three-story (short period) and forty-story (long period) steel moment-resisting frame buildings is characterized in terms of the median and distribution of peak inter-story drift ratio for a range of near-fault sites. The full suite of 18 fault rupture realizations and approximately 280,000 nonlinear dynamic building simulations indicate that the three-story building undergoes higher median seismic demand and significantly greater variability of demand at a given site than the forty-story building, which has important implications for the level of certainty in predicting building performance during an earthquake. The simulations performed provide deeper insight into the relationship between fault rupture parameterization and building response, which is essential information for developing a representative suite of rupture realizations for specific earthquake scenarios.

58 GEOSCIENCES↗

SU-G-BRB-17: Dosimetric Evaluation of the Respiratory Interplay Effect During VMAT Delivery Using IPAGAT Polymer Gel Dosimeter

Purpose: To evaluate the dosimetric impact of the interplay effect between multileaf collimator (MLC) movement and tumor respiratory motion during delivery of volumetric modulate arc therapy (VMAT) by using customized polymer gel dosimeter. Methods: Polyacrylamide-based gel dosimeter contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. An excellent gas barrier PAN (BAREX) techno bottle (φ8 cm, 650 mL) filled with iPAGAT was set to the QUASAR™ respiratory motion phantom, and was moved with motion amplitudes of 1 and 2 cm with a 4 second period during VMAT delivery by the Novalis Tx linear accelerator (Varian/BrainLAB). Two spherical tumors with a 2 cm diameter (GTV1 and GTV2) were defined, and ITV1 (GTV1+1 cm) and ITV2 (GTV2+2 cm) with expansion in the superior-inferior (S-I) direction were also defined with simulated respiratory motion. PTV margin was 2 mm around the ITV considering the setup uncertainty. Two single arc VMAT plans with 30 Gy at 3 Gy per fraction (GTV: D98>100%, PTV: D95=100%) were generated by the Varian Eclipse treatment planning system. Three-dimensional dose distribution in iPAGAT was read out by the Signa 1.5T MRI system (GE), and was evaluated by dose-volume histogram (DVH) using in-house developed software. Results: According to DVH analysis by iPAGAT, D98 of GTV1 and GTV2 were more than 100% of the prescribed dose. In contrast, D95 of PTV1 and PTV2 were about 85% and 65%, respectively. Furthermore, low-to-intermediate dose was widespread with motion amplitude of 2 cm. Conclusion: DVH analysis using iPAGAT polymer gel dosimeter was performed in this study. As a result, interplay effect was negligible, since dose coverage of GTV was sufficient during VMAT delivery with simulated respiratory motion. However, the dose reduction of PTV and the spread of low-to-intermediate dose compared to the planned dose require scrupulous attention for large tumor respiratory motion.

60 APPLIED LIFE SCIENCES↗

Pilot/vehicle model analysis of visual and motion cue requirements in flight simulation

The optimal control model for pilot/vehicle analysis is used to explore the effects of a CGI visual system and motion system dynamics on helicopter hover simulation fidelity. This is accomplished by expanding the perceptual aspects of the model to include motion sensing and by relating CGI parameters to information processing parameters of the model. Simulator fidelity is examined by comparing predicted performance and workload for flight with that predicted for various simulator configuration. The results of the analysis suggest that simulator deficiencies or a reasonable nature (by current standards) can result in substantial performance and/or workload infidelity. Both CGI and motion system effects are significant for this task. There is also a distinct interaction between the two sources of pilot cues. In particular, the presence of motion reduces the sensitivity to CGI limitations.

Lancraft, R.↗

Improved frame-based estimation of head motion in PET brain imaging

Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.

60 APPLIED LIFE SCIENCES↗

Cryogenic Equivalence Principle Experiment

The purpose of this project is to test the equivalence of inertial and passive gravitational mass in an Earth-orbiting satellite. A ground-based experiment is now well developed. It consists of comparing the motions of two cylindrical test masses suspended in precision superconducting magnetic bearings and free to move along the horizontal (axis) direction. The masses are made of niobium and lead-plated aluminum. A position detector based on a SQUID magnetometer measures the differential motion between the masses. The periods of the masses are matched by adjustment of the position detector until the system is insensitive to common mode signals, and so that the experiment is less sensitive to seismic vibration. The apparatus is contained in a twelve inch helium dewar suspended in a vibration isolation stand. The stand achieves 30 db isolation from horizontal motions between 0.1 and 60 Hz, by simulating the motion of a 200 meter long pendulum with an air bearing. With this attenuation of seismic noise and a common mode rejection ratio of 10 to the 5th power in the differential mode, the ground based apparatus should have a sensitivity to equivalence principle violations of one part in 10 to the 13th power; the satellite version might have a sensitivity of one part in 10 to the 17th power.

Everitt, C. W. F.↗

Immunity-Based Aircraft Fault Detection System

In the study reported in this paper, we have developed and applied an Artificial Immune System (AIS) algorithm for aircraft fault detection, as an extension to a previous work on intelligent flight control (IFC). Though the prior studies had established the benefits of IFC, one area of weakness that needed to be strengthened was the control dead band induced by commanding a failed surface. Since the IFC approach uses fault accommodation with no detection, the dead band, although it reduces over time due to learning, is present and causes degradation in handling qualities. If the failure can be identified, this dead band can be further A ed to ensure rapid fault accommodation and better handling qualities. The paper describes the application of an immunity-based approach that can detect a broad spectrum of known and unforeseen failures. The approach incorporates the knowledge of the normal operational behavior of the aircraft from sensory data, and probabilistically generates a set of pattern detectors that can detect any abnormalities (including faults) in the behavior pattern indicating unsafe in-flight operation. We developed a tool called MILD (Multi-level Immune Learning Detection) based on a real-valued negative selection algorithm that can generate a small number of specialized detectors (as signatures of known failure conditions) and a larger set of generalized detectors for unknown (or possible) fault conditions. Once the fault is detected and identified, an adaptive control system would use this detection information to stabilize the aircraft by utilizing available resources (control surfaces). We experimented with data sets collected under normal and various simulated failure conditions using a piloted motion-base simulation facility. The reported results are from a collection of test cases that reflect the performance of the proposed immunity-based fault detection algorithm.

Dasgupta, D.↗

Unsteady aerodynamic simulation of multiple bodies in relative motion

A prototype method for time-accurate simulation of multiple aerodynamic bodies in relative motion is presented. The method is general and features unsteady chimera domain decomposition techniques and an implicit approximately factored finite-difference procedure to solve the time-dependent thin-layer Navier-Stokes equations. The method is applied to a set of two- and three-dimensional test problems to establish spatial and temporal accuracy, quantify computational efficiency, and begin to test overall code robustness.

Meakin, Robert L.↗

SU-F-P-32: A Phantom Study of Accuracy of Four-Dimensional Cone-Beam CT (4D-CBCT) Vs. Three-Dimensional Cone Beam CT (3D-CBCT) in Image Guided Radiotherapy

Purpose: SymmetryTM 4D IGRT system of Elekta has been installed at our institution, which offers the 4D CBCT registration option. This study is to evaluate the accuracy of 4D CBCT system by using the CIRS 4D motion phantom and to perform a feasibility study on the implementation of 4D-CBCT as image guidance for SBRT treatment. Methods: The 3D and 4D CT image data sets are acquired using the CIRS motion phantom on a Philips large bore CT simulator. The motion was set as 0.5 cm superior and inferior directions with 6 seconds recycle time. The 4D CT data were sorted as 10 phases. One identifiable part of the 4D CT QA insert from CIRS phantom was used as the target. The ITV MIP was drawn based on maximum intensity projection (MIP) and transferred as a planning structure into 4D CBCT system. Then the 3D CBCT and 4D CBCT images were taken and registered with the free breath (3D), MIP (4D) and average intensity projection (AIP)(4D) reference data sets. The couch shifts (X, Y, Z) are recorded and compared. Results: Table 1 listed the twelve couch shifts based on the registration of MIP, AIP and free breath CT data sets with 3D CBCT and 4D CBCT for both whole body and local registration. X, Y and Z represent couch shifts in the direction of the right-left, superior-inferior and anterior-posterior. The biggest differences of 0.73 cm and 0.57 cm are noted in the free breath CT data with 4D CBCT and 3D CBCT data registration. Fig. 1 and Fig. 2 are the shift analysis in diagram. Fig. 3 shows the registration. Conclusion: Significant differences exist in the shifts corresponding with the direction of target motion. Further investigations are ongoing.

60 APPLIED LIFE SCIENCES↗

ULTRA-DEEP HUBBLE SPACE TELESCOPE IMAGING OF THE SMALL MAGELLANIC CLOUD: THE INITIAL MASS FUNCTION OF STARS WITH M {approx}< 1 M {sub Sun}

We present a new measurement of the stellar initial mass function (IMF) based on ultra-deep, high-resolution photometry of >5000 stars in the outskirts of the Small Magellanic Cloud (SMC) galaxy. The Hubble Space Telescope (HST) Advanced Camera for Surveys observations reveal this rich, cospatial population behind the foreground globular cluster 47 Tuc, which we targeted for 121 HST orbits. The stellar main sequence of the SMC is measured in the F606W, F814W color-magnitude diagram down to {approx}30th magnitude, and is cleanly separated from the foreground star cluster population using proper motions. We simulate the SMC population by extracting stellar masses (single and unresolved binaries) from specific IMFs and converting those masses to luminosities in our bandpasses. The corresponding photometry for these simulated stars is drawn directly from a rich cloud of 4 million artificial stars, thereby accounting for the real photometric scatter and completeness of the data. Over a continuous and well-populated mass range of M = 0.37-0.93 M {sub Sun} (e.g., down to a {approx}75% completeness limit at F606W = 28.7), we demonstrate that the IMF is well represented by a single power-law form with slope {alpha} = -1.90 ({sup +0.15} {sub -0.10}) (3{sigma} error) (e.g., dN/dM{proportional_to} M {sup {alpha}}). This is shallower than the Salpeter slope of {alpha} = -2.35, which agrees with the observed stellar luminosity function at higher masses. Our results indicate that the IMF does not turn over to a more shallow power-law form within this mass range. We discuss implications of this result for the theory of star formation, the inferred masses of galaxies, and the (lack of a) variation of the IMF with metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

Manual Crew Override of Vehicle Landings Following G-Transitions

BACKGROUND Manual control during exploration spaceflight consists of both planned automated supervisory control and unplanned crew override. This crew override capability is critical to enable overall mission success during landing contingencies. However, the introduction of manual override capabilities must be implemented to enable crews to mitigate risks introduced by human error. Adaptive changes in the sensorimotor system can manifest during g-transitions as spatial disorientation. While training and landing aids enable successful landing through disorientation, these adaptive changes may increase cognitive demand that needs to be accounted for in the manual control strategy. It is important to characterize these effects as soon as possible following the G-transition to develop appropriate countermeasures. METHODS In this study, we will examine operational piloting tasks following International Space Station (ISS) missions in a simulated lunar landing using a six-degree-of-freedom (6DOF) motion base. The motion-based simulation will be implemented in our laboratory at the Johnson Space Center (JSC) and will be available within hours following the return from commercial crew landings. The primary goals of this study are (1) to understand the impact of spaceflight on crew ability to perform manual crew override tasks, (2) to examine how adaptive changes in vestibular and cognitive function relate to changes in manual crew override proficiency, and (3) compare performance during late “just-in-time” on-board training with early post-flight crew performance. The impact of spaceflight on piloting capability will be assessed from pre- versus post-flight changes in crewmembers assigned to either short duration (< 30 day) or long duration (~6- month) missions to the International Space Station (ISS). Individual differences in post-flight vestibular and cognitive changes include motion sickness reports, measures of tilt motion perception accuracy and precision, and dual-task tracking. During the 6DOF lunar simulation, the crew will manually takeover attitude and rate-of-descent to the nominal or re-designated landing aim point during the approach phase. The outcome measures for the lunar crew override tasks will be the percent time maintaining actual vehicle states, e.g., attitude and rate-of-descent, within recommended guidance during the landing approach, number and maximum deviation outside limits, and root mean square error (RMSE). Given that “just-in-time” (JIT) training is an operational expectation for the Human Landing System (HLS) program, all participants will perform late inflight JIT training for each manual crew override task in which they will participate. Crew proficiency will be captured inflight during JIT training that will be implemented on a laptop with hand controllers to allow the crewmember to practice the landing task procedures like the approach implemented for JIT training with Shuttle landing and ISS telerobotic tasks. COUNTERMEASURE UPDATES The lunar lander simulation has been implemented onto a two-laptop display system where subjects select from alternative landing points, based upon avoiding hazards that the on-board system identifies during the landing. The subject makes inputs using a rotational hand controller (i.e., joystick) and a translational hand controller, which are processed by simulated vehicle dynamics to update the vehicle attitude and rate of descent. Subjects will utilize a combination of flight, situation, and status displays to monitor the state of the simulated vehicle. The simulation exports tilt and translation movements to a 6DOF motion base synced to visual movements and provides representative vestibular cues to the subject while performing the task inside an enclosed cabin featuring a simulated lunar out-the-window view and a heads-down lander cockpit view. RELEVANCE This project will deliver an operational demonstration of crew override capability following spaceflight and identify potential deficits that may require remediation. Comparison of individual vestibular and cognitive changes with crew override performance will help better characterize the manual control risks associated with sensorimotor alterations. The inclusion of “just-in-time” on-board training will ensure we are characterizing changes in override proficiency with this expected countermeasure in place. ACKNOWLEDGEMENTS: The authors acknowledge contributions from Draper, HLS Joint Test Panel, Crew HLS Interfaces for Piloting Working Group, and Dynamic Skills Trainer (DST) Lab toward the development of the lunar landing simulation. This project is funded by the Human Health Countermeasures Element.

Austin M Bollinger↗

Rocket-Booster Towing Simulation

Report describes computer simulation of motion of solid-rocket ship. Listing of simulation program in FORTRAN. Mathematical techniques useful in such other maritime applications as buoy or ship design.

Trovillion, T. A.↗

Numerical Simulation of Thermocapillary Drop Motion with Internal Circulation

The thermocapillary motion of drops in zero gravity is analyzed numerically. When convective transport is important, the internal circulation in the drop has a profound effect on the temperature distribution in its vicinity and hence on its migration speed. For sufficiently large values of the Marangoni number number Ma, for steady motion of the drop, the temperature difference on the drop surface and its scaled speed increase with Ma. This is in contrast to (1) existing computational results for liquid drops whose scaled speed decreases with Ma and (2) asymptotic results for gas bubbles whose scaled speed is independent of Ma when it is large.

Ma, Xiangjiang↗